| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC NO 16 7 739 3RD FLOOR OSMANPURA CHADERGHAT HYDERABAD TELANGANA 500 024 | HYDERABAD | HYDERABAD | TELANGANA | 500024 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.6 L+₹65,775 (5.99%)Rejected-Finance 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹17.1 L+₹6.2 L (56.3%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category c (i) |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
28 Oct 2024, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
REPAIR MAINT OF SPLIT WINDOW TYPE ACs WATER COOLERS REFRIGERATORS DEEP FREEZERS VOLTAGE STABILIZERS WITH ALLIED WORKS AT AFS TAMBARAM
2024_MES_676356_1
GE(AF)/TBM/8775/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Airforce Station Tambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹42,000
Yes
21 Nov 2024
24 Sept 2024
30 Oct 2024
24 Sept 2024
28 Oct 2024
8 Oct 2024
Amount
A) WINDOW TYPE AC
Dismantling the unserviceable uncut hermetically sealed compressor from the AC unit and replacement with factory re-conditioned hermitically sealed compressor for window Air conditioner of any make including transportion for 1.5 Ton capacity complete all as specified and as directed.
All as per item No.1.01 above but 2.0 Ton capacity
Dismantling the unserviceable uncut rotary compressor from the AC unit and replacement with new rotary compressor 1.5/ 2.0 Ton capacity complete all as specified and as directed. Note for item 1.01,1.02 &1.03: The cost of gas shall be measured and paid separately as supply only.
M&L for flushing out of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging , testing and commissioning of system upto 2 TR capacity of window type Air conditioners complete all as specified and as directed. NOTE :- (i) The cost deemed included the replacement of spares like coper tubes any description, strainer assly, capillary tubes etc. (ii) The required gas shall be measured and paid under relvant items of this schedule.
S&F in repairs new condensing unit housing for any given make for window type AC including dismantling the old unserviceable condensing unit complete all as specified and as directed.
S&F in repairs new cooling coil unit housing for any given make for window type AC including dismantling the old unserviceable cooling coil complete all as specified and as directed.
S&F in repairs condenser/ cooling coil housing jointing plate for window AC of any make for 1.5 / 2.0 Ton capacity including dismantling the old unserviceable jointing plate complete all as specified and as directed.
S&F in repairs following spares/ items for window type AC unit of any capacity including dismantling the old unserviceable items :-
Cooling coil.
Condenser coil.
Standard outer cover
Front panel with grill
Fan blade set
Brand new fan motor 1/5 HP
Overload Protector
Starting relay
Starting capacitor 80-100 MFD
Running capacitor 25/ 36 MFD
Thermostat Switch
S&F in replacement single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with single pole MCB 20/ 25 Amps for incoming and out going control.
Taking out outer cover of 1.5/ 2.0 TR capacity on wall of window, cleaning of all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carrying out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition complete all as specified and as directed.
B)SPLIT TYPE AC
Dismantling the unserviceable uncut hermetically sealed compressor from the AC unit and replacement with factory re-conditioned hermetically sealed compressor for split type Air conditioner of any Make including transporting for 1.5 Ton capacity complete all as specified and as directed.
All as per item No.5.01 above but for 2.0 Ton capacity
Dismantling the unserviceable uncut rotary compressor from the AC unit and replacement with new rotary compressor 1.5 Ton capacity complete all as specified and as directed. Note for item 5.01,5.02 & 5.03: The cost cost of gas shall be measured and paid separately as supply only.
All as per item No.5.03 above but for 2.0 Ton capacity
M&L for flushing out of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging and testing and commissioning of system upto 2 TR capacity of Split type Air conditioners complete all as specified and as directed. NOTE :- (i) The cost deemed included the replacement of spares like coper tubes any description, strainer assly, capillary tubes etc. (ii) The required gas shall be measured and paid under relvant items of this schedule.
S&F the following spares/ items for split type AC 1.5 Ton capacity including dismantling the old unserviceable spares/ items complete all as specified and as directed.
Remote control.
Electronic PCB Board
Electronic PCB Board for Inverter AC
Fan motor 1/6HP capacity.
Condenser coil
Suction valve
Discharge valve
PVC conduit pipe 20mm dia including all accessories to drain out pipe
Indoor unit blower motor of 1.5/ 2.0 ton split type AC
Starting relay
Starting capacitor 80-100 MFD
Running capacitor 25/36 MFD
Fan blade set
Air filter suitable for air conditioner 1.5 /2.0Ton capacity
Taking out outer cover of 1.5/ 2.0 TR capacity Condensing unit on wall/ floor of split type AC for repairing, cleaning of all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carry out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition complete all as specified and as directed.
Installation of split type Air conditioner any capacity including Supply & fixing factory fabricated support suitable to mount out door unit (one pair per AC) and duly making holes into wall for insertion of copper pipe, drain pipe and 3 core cable and making good the disturbed surfaces complete all as specified and as directed. Note: This item to be operated for change of location only, as split type AC unit to be shifted from one location to other location.
Taking out Indoor & outdoor cover of 3 TR capacity Condensing unit on wall/ floor/ceiling of Cassettet type AC for repairing, cleaning of all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carry out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition complete all as specified and as directed.
Taking out Indoor unit & Supply and fix indoor unit only 1.5TR including filter and copper pipe with suitable outdoor unit complete all as specified and as directed.
Taking out wrested outdoor unit body and supply and fix new outdoor body without compressor and condensor.unit complete all as specified and as directed.
Taking out U/S stablizer and supply & fix stabilizer 4KVA double booster complete all as specified and as directed.
Taking out Indoor & outdoor cover of 6000 to 15000 BTUH capacity Condensing unit on wall / floor of Walkin cooler cum Cold storage unit for repairing, cleaning of all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carry out servicing & lubricating of all parts,including servicing of PCB / Condensor unit, checking and tightening electrical connections and ensuring complete unit in perfect working condition complete all as specified and as directed.
Taking out US AC Manager & Supply and fix AC Manager for connecting two AC complete all as specified and as directed.
C) WATER COOLER
Dismantling the unserviceable uncut hermetically sealed compressor from the water cooler unit and replaced with factory re-conditioned hermetically sealed compressor for water cooler of any make upto 120 ltrs capacity complete all as specified and as directed.
All as per item No.15.01 above but 150 ltrs capacity. Note for Sl item No 15.01 & 15.02 :Gas charging will be measured and paid separately.
M&L for flushing out water cooler of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging and testing and commissioning of system upto 120/150 ltr.cooling capacity complete all as specified and as directed. NOTE :- (i) The cost deemed included the replacement of spares like coper tubes any description, strainer assly, capillary tubes etc. (ii) The required gas shall be measured and paid under relvant items of this schedule.
S&F the following spares/ items for 40 to 150 ltrs water cooler including dismantling the old unserviceable spares/ items complete all as specified and as directed.
Starting relay
Starting capacitor 80-100MFD
Running capacitor 36MFD
Over load protector
Thermostat
Fan blade assembly suitable for water cooler
Push cock brass chromium plated of size 15mm.
Brand New fan motor with base 1/10HP
Top lid gasket for 120/ 150 ltr capacity water cooler
Drain stainless steel tray with drain elbow and connector
Gate valve brass screwed both ends of size 15mm bore
Float valves PVC with PVC ball complete suitable for 15mm bore ISI marked
PVC hose connection pipe both ends having brass coupling threaded for 15mm GI tubing of standard length.
Cutting & removing the existing bottom frame of water cooler of capacity 120/ 150 ltr and re-fabrication of bottom frame of suitable size with mild steel angle iron 25x25x4mm and welded with 2mm thick MS sheet upto 30cm from bottom height including legs complete all as specified and as directed.
Cutting and removing the front bottom of water coolers and refixing of new front bottom with 1.6mm thick MS sheet complete all as specified and as directed.
Taking out outer cover of water coolers 40 to 150 ltrs capacity, cleaning of all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carrying out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition complete all as specified and as directed.
Painting of water cooler with two coats of pastel blue paint to the external surface of water cooler and Two coats of anticorrosive black paint over a coat of red oxide primer upto 15cm height from the base allround including legs for inside of water cooler of any capacity complete all as specified and as directed.
D) REFRIGERATOR
Dismantling the unserviceable uncut hermetically sealed compressor from the Refrigerator unit and replace with factory re-conditioned hermetically sealed compressor for refrigerator of any make 200 ltrs to 310 ltrs capacity complete all as specified and as directed.
All as per item No.21.01 above but capacity 165 ltrs to 200 ltrs. Note for Sl item No 21.01 & 21.02: Gas charging will be measured and paid separately.
Supply only Gas R - 134 A
Supply only Gas R - 32
Supply only Gas R - 410/R-22
M&L for flushing out of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging and testing and commissioning of system upto 165 to 310 ltr.cooling capacity NOTE :- (i) The cost deemed included the replacement of spares like coper tubes any description, strainer assly, capillary tubes etc. (ii) The required gas shall be measured and paid under relvant items of this schedule.
S&F the following spares/ items for 165 to 310 ltrs Refrigerator including dismantling the old unserviceable spares/ items complete all as specified and as directed.
Relay box type
Over load protector 1/6HP
Thermostat defrosting type
Door magnetic gasket
Cooling coil
Condenser coil
Freezer door
Vegetable tray with glass
New frost free motor
Renewal of entire portion of base plate and legs, welding with proper gauge new MS sheet complete all as directed and specified of refrigerators capacity 165 ltrs to 310 ltrs complete all as specified and as directed.
Two coats of Aspa paint on exterior face of the refrigerator of any capacity by spray painting including removing the dirt etc.,complete all as specified and as directed.
Taking out refrigerators for servicing by cleaning all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carrying out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition complete all as specified and as directed.
E) DEEP FREEZER
Dismantling the unserviceable uncut hermetically sealed compressor from the deep freezer unit and replaced with factory re-conditioned hermetically sealed compressor for deep freezer any make 500 ltr capacity complete all as specified and as directed. Note: Gas charging will be measured and paid separately
M&L for flushing out of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging and testing and commissioning of system upto 165 to 320ltr.cooling capacity complete all as specified and as directed. NOTE :- (i) The cost deemed included the replacement of spares like coper tubes any description, strainer assly, capillary tubes etc. (ii) The required gas shall be measured and paid under relvant items of this schedule.
S&F the following spares/ items for 320 ltrs deep freezer including dismantling the old unserviceable spares/ items complete all as specified and as directed.
Relay box type
Over load protector 1/6HP
Door magnetic gasket
Condenser coil
Brand New fan motor with base 1/10HP
Taking out Deep freezer for servicing by cleaning all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carrying out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition complete all as specified and as directed.
M&L in replacement Sub main wiring with two single run of single core PVC insulated cable with copper conductor multistranded 1100 volts grade 4 sqmm through and including with suitable size of PVC rigid conduit and its accessories, surface/ ceiling along with fixing arrangements etc., including 4.0 sqmm PVC insulated multistranded copper earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
All as per item No.26 above but with 2 runs of 6 sqmm Note for Sl Item No.25 & 26:- (i) Two runs of cable, one/ two runs of earth conductor cable and one run of PVC conduit shall be measured as one unit. (ii) The cost deemed to be included for cutting and chasing and making good the disturbed surfaces complete all as specified and as directed.
S & F three core flexible cord copper wire of size 3 Core 4 Sqmm suitable for all summer applainceas directed & specified.
S&F the following copper pipes for all summer appliances of any capacity including dismantling the unserviceable pipe.
Copper pipe 1/2" dia
Copper pipe 3/8" dia
Copper pipe 5/8" dia
Copper pipe 1/4" dia
rc enterprises (BID ID -3147334)
SJM CONSTRUCTIONS (BID ID -3151921)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .