| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | L1 | Accepted-AOC QUOTED REASONABLE RATE | |
| 2 | L2₹12.2 L+₹1.9 L (18.1%)Rejected-Finance | L2 | Rejected-Finance QUOTED HIGH RATE |
Tender Value
₹9.3 L
EMD Value
₹19,000
Closing Date
28 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JAISALMER
HQ CWE AF JAISALMER
ANNUAL REPAIR AND MAINTENANCE OF ARC COMPLEX JAISALMER
2023_MES_633262_2
80279
Open Tender
Civil Works
Item Rate
365 days
GE (AF) JAISALMER
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) JAISALMER
₹19,000
Yes
20 Mar 2024
9 Feb 2024
29 Feb 2024
9 Feb 2024
28 Feb 2024
16 Feb 2024
Amount
Taking down chowkhats or frame/steel windows not exc 1.50 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exc 1.50 but not exc. 4 sqm in each complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of Concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections and fittings, including cleaning for refixing or removal from site complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections and fittings, including cleaning for refixing or removal from site complete all as specified and directed.
Taking down cement plaster of any description, on brick or stone or PCC block masonry walls/ceiling etc. including raking out joints, hacking for key, scrubbing down with water etc and including removing debris/rubbish from the premises upto 500m from site complete all as specified and directed.
Hacking out old broken glass (any thickness, any size, quality or description) from metal frame / wooden frames or stone, concrete or brick surrounds, including punching or drilling out old glazing pins/spring clips and providing and fixing new ones glazed with putty or fixed with beads complete all as specified and directed.
Demolition and breaking up drain pipe (SGSW, AC, RCC or PVC) of size upto 150mm bore including demolition of PCC bed concrete as in benching and hauching, etc., and including removing debris/rubbish from the premises upto 500m outside the MoD land complete all as specified and directed.
Cutting chases in brick wall, stone, concrete block walls and slabs, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Excavating in trenches in soft/loose soil n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
Returning filling in including spreading levelling watering &well ramming in layers n.exc 25cm in hard/dence soil complete all as specified and directed.
Removing of excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, roof padding on roof for correction of slope, levelling coarse, roof kerbs of mud stops or similar works, etc complete all as specified and directed.
M&L for precast cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and directed.
M&L for Plain cement concrete (1:4:8), type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) 100mm thick and 450mm wide as in bed of drain pipe inch packing under and haunching against the sides of pipe after they are laid and tested for 150mm dia of pipe complete all as specified and directed.
M&L for 15mm thick rendering cement plaster in cement mortar (1:6) on stone masonry surfaces or other than of fair faces of brick or concrete surfaces, finished even and fair complete all as specified and directed.
M&L for 10mm thick rendering cement plaster on any faces of brick work or concrete surfaces in cement mortar (1:4) surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick rendering cement plaster on uneven faces of concrete surfaces in ceilings in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plaster surfaces of walls and applying 2mm thick readymixed wall putty on entire surface of wall etc cutting and finishing with appropriate sand paper and applying two coat of oil bound distemper (White or tinted) over one coat of primer after smoothening of surfaces of wall complete all as specified and directed.
M&L for preparing old painted surfaces of walls by washing , rubbing down and stopping painted surfaces and applying 2mm thick ready mixed wall putty on entire surface of wall etc cutting and finishing with appropriate sand paper and applying one coat of oil bound distemper (White or tinted) over one coat of primer after smoothening of surfaces of wall complete all as specified and directed.
M&L for preparing new plaster surfaces of walls and applying two coats of oil Exterior Emulsion Paint APEX (White or tinted) over one coat of primer after smoothening of surfaces of wall complete all as specified and directed.
M&L for preparing old painted decorated/undecorated surfaces of walls by brooming down and steel wire brushing, scrapping down smoke soot, and greasy spots etc, and applying one coat of oil Exterior Emulsion Paint APEX (White or tinted) complete all as specified and directed.
M&L for preparing new plaster surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of old painted wooden surface or wood based materials of any description, not otherwise described, over 10cms width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted steel surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors, etc. over and including 15mm thick screed bedding in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
M&L for (300mm x450mm) x 6 to 7mm thick coloured glazed ceramic tiles as in verticle surfaces,skirtings, dado, risers, steps, treads etc. over and including 10mm thick bedding layer in cement mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the surface complete all as specified and directed.
M&L for 9-10 mm thick Virified Ceramic tiles light shade (square/ rectangular) polished, area of each tiles exceeding 0.18sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match cement to match the surface over and including 15mm thick screed bedding in cement mortar (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.complete all as specified and directed.
M&L for 9-10 mm thick Virified Ceramic tiles light shade (square/ rectangular) polished, area of each tiles exceeding 0.18sqm but not exceeding 0.36 sqm, as in verticle surfaces,skirtings, dado, risers, steps, treads etc.. set and jointed in neat cement slurry and pointed in white or coloured cement to match cement to match the surface over and including 10mm thick bedding layer in cement mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the surface complete all as specified and directed.
M&L 18-20mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills, cooking platforms, WHB plateform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rubbing and polishing complete necessary cutting, notching etc complete all as specified and directed.
S&F 10mm dia and over Mild steel TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as binding with and including mild steel wire (Annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batte, fair finished flat complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame/shutter work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including roller for sliding window, handle, locking device, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and complete all as specified and as directed.
S&F 5.0mm thick Figured glass pin headed type and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and as directed.
S&F Stainless steel (Grade SS-304) wire cloth 0.36mm nominal dia of wire and average width of aperture1.4mm and fixed with stainless steel wire staple fixed with aluminium beading etc complete all as specified and as directed.
S&F 6.0mm thick Veneered decorative plywood, 5 nos ply, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber/aluminium frame work complete all as specified and as directed.
S&F 0.50mm thick pre-painted galvalume aluminum zinc coating GI based Plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
S&F factory made solid PVC door frame of size 50x47mm made out of 5mm thick rigid PVC foam sheet reinforced with MS square tube complete all as specified and as directed.
S&F 30mm thick (style) factory made solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails MS frame shall be convered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raials with suitabale PVC sheet beading, and jointed together with solvant cement and fixing in the frame at side complete all as specified and as directed.
S&F in repairs Mortice lock brass, vertical type, size 100 mm 4 lever complete all as specified and as directed.
S&F 100mm long Butt hinges, extruded stainless steel hinge pin anodisedand fixed type B-12 complete all as specified and as directed.
S&F 150mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed.
S&F 150mm size aluminum anodized handle fabricated type complete all as specified and as directed.
S&F in repairs Floor door stopper of aluminium alloy body and tongue, anodised, 150mm overall length of cover plat, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
S&F in repairs double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
S&F 15mm bore galvanised steel tubing (ISI) marked medium grade with necessary fittings lie tees, elbows, sockets, reducers, bends etc including necessary cutting, threading laid in trenches/floors, fixed to walls(concealed) etc complete all as specified and directed.
S&F 20mm bore galvanised steel tubing (ISI) marked medium grade with necessary fittings lie tees, elbows, sockets, reducers, bends etc including necessary cutting, threading laid in trenches/floors, fixed to walls(concealed) etc complete all as specified and directed.
S&F in repair water closet vitreous china squatting pan Orissa pattern of size 580x440mm white with integral foot rest front/back inlet (excluding flushing cistern and flush pipe) including provision of cement concrete bedding in PCC (1:5:10) type E2 and making good to disturb surface complete all as specified and as directed.
S&F in repairs Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper including waste fitting, brass chromium plated 32 mm size with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and as directed.
S&F in repair 10 litres capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with flush pipe etc. ISI approved complete all specified and directed.
S&F in repair 15mm bore fancy type chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repair 15mm bore fancy type chromium plated pillar taps, Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed ule complete all as specified and as directed.
S&F in repair fancy type chromium plated 15 mm bore stop valve/angle cock, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repair PVC connections suitable for 15mm dia pipe with PTMT nut of length 600mm complete all as specified and as directed.
S&F in repair 32mm bore Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm45gms/40mm-60 gms) complete all as specified and as directed.
S&F in repair 32mm bore PVC waste pipe of suitable length complete all as specified and as directed.
S&F in repair 20mm dia brass chromium plated tubular towel rail D-Type, 60cm long between flanges complete all as specified and as directed.
S&F in repair 75x125mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repair 75mm dia Cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
S&F in repair 110mm dia Cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
S&F 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed.
S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches/floor or fixed to walls including digging and making good as existing complete all as specified and as directed.
S&F in repair 110mm dia PVC (SWR) bend any radius with access door complete all as specified and as directed.
S&F in repair 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to walls including digging and making good as existing complete all as specified and as directed.
S&F in repair 75mm dia PVC (SWR) bend any radius complete all as specified and as directed.
Cleaning of Septic tanks with manholes including bailing out the foul water and taking/removing out sludge from septic tanks and manholes and disposal of the same to the dumping yard or STP of municipal corporation of city as directed by Engineers-In-Charge. (Nothing extra shall be paid for work in foul conditions and transportation of sludge to dumping yard or STP of municipal corporation of city). Note:- The contractor shall arrange for all safety arrangements for labours to work in foul conditions.
Cleaning solid/liquid mud deposited in under ground sewage lines, upto and including 150mm dia bore, of any type, between consecutive manholes, by hydraulic jet pressure machine, through connecting manholes with complete men, machine and water as required, including removal and refixing of manhole covers, complete all as specified and directed. Notes:- The contractor will arrange safaiwala immediately on reciept of complaint and ensure that complaint is resolved within 24 hours and no lapse will be allowed. The contractor shall arrange for all safety arrangements for labours to work in foul conditions. Centre to centre of manholes shall be reckoned for purpose of cleaning sewage line.
M&L for cleaning of underground water storage tank/Sump/Closed static Water tank of any size and any depth, cleaning of walls of the tank using a mixture of 1 part bleach to 4 parts hot water, wash the sides of the tank with the mop(or pressure washer) in order to remove the slime and dirt build up on the sides and corners of the tank. Scrub the build-up on the bottom of the tank and use wet/dry vaccum to remove the rinse water form the tank. Notes:- 1. Contractor shall make necessary safety arrangements so that the cleaners enter the tank for cleaning. 2.The rate is inclusive of the pumping out of the water available in the tank before cleaning. 3. The cleaning and pumping out of the rinse/waste water shall be done upto satisfaction level of the users.
Attending day to day complaints as and when required with necessary T&P by deploying skilled labour i.e Carpenter, Plumber and mason etc as directed by Engineer-in-Charge.
Attending day to day complaints as and when required with necessary T&P by deploying Sewerman for opening of blocked rain water pipes, sewer line, gully traps, manhole chambers etc. as directed by Engineer-in-Charge.
Attending day to day complaints as and when required with necessary T&P by deploying skilled labour/mechanic i.e AC mechanic, Electrician, DG mechanic etc. complete all as specified and directed by Engineer-in-charge.
Servicing of split Air conditioner of capacity 2Ton/1.5 Ton including servicing and repair to voltage stabilizers complete all as specified and directed.
Servicing and repair of monoblock pump set and submersible pump set of capcity upto 3 HP complete all as specified and directed.
Servicing and repair of DG set of capacity 30 KVA including change of engine oil, oil filter, fuel filter and painting of outer body of DG set complete all as specified and directed.
S&F LED aviation obstruction light complete all as specified and directed.
Repair and maintenance of Desert cooler inluding change of wood pad, submersible water lifting pump and repair to motor complete all as specified and directed.
Taking down carefully aluminium point wiring on wooden battens/through conduit (light fan, socket or power) complete with fittings such as switches, wooden batten, ceiling roses, pendants, regulators, box type tube light fittings, removing the materials from site except fittings etc which shall be reused in the work and making good the disturbed surfaces of walls/ceiling/ floors etc complete all as specified and as directed.
Taking down carefully unserviceable distribution board any type any capacity including MCCB's/MCB's of any type any capacitycomplete all as specified and as directed.
Taking down carefully unserviceable submain wiring any type any rating complete all as specified and as directed.
Taking down carefully ceiling fan 230 volts single phase 50 Hz from the position after dismantling fan blades of any sweeps and carrying out complete servicing with and including cleaning, greasing, replacing flexible 3 core cable of size 1.5 Sqmm with copper conductor from ceiling rose to fan, replacing rubber reel, split pins, check nuts, PVC connector complete with and including painting with 2 coats of synthetic enamelled paint over a coat of red oxide anticorrosive primer after rubbing entire fan body and blades and fixing back the fan in position complete all as specified and directed.
M&L for concealed point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLS copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly including sunken box of size 1.6mm thick and 60 mm depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frame covers, complete all as specified and directed for the folowing:-
(a) One light fan/ bell point controlled by one, one way switch
(b) One socket outlet 3 Pin, 5 Amp on the independent board
(c) One socket outlet 3 Pin, 5 Amp on the same board.
M&L for concealed point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 2.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLS copper conductor cable of 2.5 Sqmm with green insulation as earth wire and connected to earth dolly including sunken box of size 1.6mm thick and 60 mm depth pressed steel box factory made of size 175mmx100mm for mounting of switch, socket and fan regulator with modular frame covers, complete all as specified and directed for One 5 Pin, 15 Amp socket multipurpose independent .
S&F modular switch one way 6 Amp, single pole complete all as specified and directed.
S&F modular socket outlet 5 pin, 5 Amps multipurpose flush type complete all as specified and directed.
S&F ceiling rose 3 terminals complete all as specified and directed.
S&F modular switch one way 16 Amp, single pole complete all as specified and directed.
S&F modular socket 2 in 1, 6 and 16 Amps multipurpose flush type 2 module complete all as specified and directed.
S&F modular lectronic fan regulator flush mounting 300-400 Watts switch size having 4 step to regulate/ control speed of ceiling fan complete.
S&F modular white cover plate with frame, 3 module complete all as specified and directed.
S&F modular metal flush box 3 module complete all as specified and directed.
M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLSH wire 4.00 Sq mm 1100 volts grade including and 4.00 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in rigid PVC conduit 25mm bore complete all as specified and directed. Note : Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm cable as earth continuity conductor and 25mm rigid PVC conduit shall be measured and paid as one unit.
S&F in replacement of sheet metal enclosure for MCB distribution board TPN, double door 4 way, vertical type with 200 Amp rated bus bar 415 V complete all as specified and directed.
S&F in replacement sheet metal enclosure factory fabricated for MCB distribution board SPN 240 volt, 12 way with suitable Amp rated bus bar having IP-42 protection and double metal door concealed in wall including connection with thimbles as required complete all as specified and directed.
S&F in replacement sheet metal enclosure factory fabricated for MCB distribution board SPN 240 volt, 8 way with suitable Amp rated bus bar having IP-42 protection and double metal door concealed in wall including connection with thimbles as required complete all as specified and directed.
S&F MCCB FP, 125 Amp, 415 volt, breaking capacity 16 KA complete all as specified and directed.
S&F MCB SPN 40-63 Amp, 240 volt, 'C' curve, breaking capacity 10 KA complete all as specified and directed.
S&F MCB SP 6-32 Amp, 240 volt, 'C' curve breaking capacity 10 KA complete all as specified and directed.
S&F in replacement LED integrated batten fitting, 18W, 230V surface mounted etc, complete with 18W LED tube rod with all accessories pre-wired including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED security light fitting 36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F exhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep with louvers complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Quoted rate of Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Quoted rate of Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
M/s Fateh Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .