Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹35.3 LAccepted-AOC 221 BISARIYA COMPLEX ZONE II M P NAGAR BHOPAL MADHYA PRADESH 462011 UDYAM MP 10 0005688 | BHOPAL | MADHYA PRADESH | 462011 | ₹35.3 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹36.6 LRejected-Finance | ₹36.6 L | L-2 | Rejected-Finance Lowest-2 |
| 3 | L-3₹44 LRejected-Finance 183 AMBEDKAR NAGAR BLOCK NO 330 JUHI LAL COLONY KANPUR 208014 | KANPUR NAGAR | UTTAR PRADESH | 208014 | ₹44 L | L-3 | Rejected-Finance Lowest-3 |
| 4 | L-4₹48.1 LRejected-Finance D S 185 186 SECTOR D LDA COLONY KANPUR ROAD LUCKNOW LUCKNOW UTTAR PRADESH 226012 UDYAM UP 50 0021159 | LUCKNOW | UTTAR PRADESH | 226012 | ₹48.1 L | L-4 | Rejected-Finance Lowest-4 |
| 5 | L-5₹50.3 LRejected-Finance 405 406 FF NILKANTH PALACE OPP KARMA SHRSTHAN TOWER 100 FT ROAD JODHPUR SATELLITE AHMEDABAD GUJARAT 380015 UDYAM GJ 01 0017203 | AHMADABAD | GUJARAT | 380015 | ₹50.3 L | L-5 | Rejected-Finance Lowest-5 |
| Sl No | Description | Qty | Unit | Ingenious Industries L6 | Weartech Engineers Pvt Ltd L1 | M/s. PRANAM HVAC ENGINEERING PVT. LTD. L5 | NAQVI BROTHERS L3 | Anoop Refrigeration L4 | VOLGA AIR TECHNOLOGIES L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with Ecofriendly Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.
100 HP ODU | 1 | Each | 21,57,026 ₹21.6 L | 15,75,000 ₹15.8 L | 24,50,000 ₹24.5 L | 19,32,190 ₹19.3 L | 15,95,328 ₹16.0 L | 15,29,658 ₹15.3 L |
| 2.00 | Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
(INDOOR UNIT-CASSETTE TYPE) 2 TR | 16 | Each | 52,984 ₹8.5 L | 33,000 ₹5.3 L | 44,500 ₹7.1 L | 39,025 ₹6.2 L | 34,375 ₹5.5 L | 37,460 ₹6.0 L |
| 3.00 | Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
(INDOOR UNIT-CASSETTE TYPE) 2.8 TR | 4 | Each | 59,496 ₹2.4 L | 35,000 ₹1.4 L | 47,500 ₹1.9 L | 43,648 ₹1.7 L | 38,700 ₹1.5 L | 36,601 ₹1.5 L |
| 4.00 | Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
(INDOOR UNIT-CASSETTE TYPE) 3.6 TR | 6 | Each | 60,680 ₹3.6 L | 36,500 ₹2.2 L | 49,500 ₹3.0 L | 45,080 ₹2.7 L | 42,300 ₹2.5 L | 39,949 ₹2.4 L |
| 5.00 | Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
(INDOOR UNIT-CASSETTE TYPE) 4 TR | 4 | Meter | 60,680 ₹2.4 L | 37,500 ₹1.5 L | 51,000 ₹2.0 L | 45,557 ₹1.8 L | 44,540 ₹1.8 L | 37,657 ₹1.5 L |
| 6.00Supply, Installation ,testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with XPLE Class-O tubular insulation / with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||||||
| 6.01 | 6.4 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation. | 25 | RMT | 513 ₹12,825 | 280 ₹7,000 | 300 ₹7,500 | 560 ₹14,000 | 1,400 ₹35,000 | 251 ₹6,275 |
| 6.02 | 9.5 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation. | 125 | RMT | 606 ₹75,750 | 440 ₹55,000 | 470 ₹58,750 | 700 ₹87,500 | 1,600 ₹2 L | 368 ₹46,000 |
| 6.03 | 12.7 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation. | 30 | RMT | 703 ₹21,090 | 600 ₹18,000 | 620 ₹18,600 | 840 ₹25,200 | 1,890 ₹56,700 | 478 ₹14,340 |
| 6.04 | 15.86 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation. | 125 | RMT | 936 ₹1.2 L | 900 ₹1.1 L | 790 ₹98,750 | 980 ₹1.2 L | 2,200 ₹2.8 L | 578 ₹72,250 |
Tender Value
₹58.0 L
EMD Value
₹1.2 L
Closing Date
18 Nov 2024, 5:00 pmClosed
SM(E-E)
AAI, R.B. Airport, Bhopal
Construction of New Fire station at R.B. Airport, Bhopal. SH- SITC of VRF/VRV Air-conditioning system
2024_AAI_212121_1
AAI/BPL/ENGG(E)/NIT-10/2024-25
Open Tender
Electrical Works
180 days
R.B. Airport
Please refer Tender documents.
24 documents required · 24 mandatory
₹1,120
₹1.2 L
6 Mar 2026
23 Oct 2024
19 Nov 2024
23 Oct 2024
18 Nov 2024
23 Oct 2024
23 Oct 2024 - 31 Oct 2024
Amount
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with Ecofriendly Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 100 HP ODU
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (INDOOR UNIT-CASSETTE TYPE) 2 TR
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (INDOOR UNIT-CASSETTE TYPE) 2.8 TR
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (INDOOR UNIT-CASSETTE TYPE) 3.6 TR
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (INDOOR UNIT-CASSETTE TYPE) 4 TR
Supply, Installation ,testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with XPLE Class-O tubular insulation / with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
6.4 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
9.5 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
12.7 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
15.86 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
19 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
22.2 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
25.4 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
28.58 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
34.9 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
38.1 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
41.27 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
44 mm dia(OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation.
Supply, installation, testing & commissioning of ref nut / Y-joints of brass for indoor and outdoor units of suitable size as per requirement. For Outdoor Unit
Supply, installation, testing & commissioning of Ref nut / Y-joints of brass for indoor and outdoor units of suitable size as per requirement. For Indoor Unit
Supply and fixing of drain piping in hard PVC with all fittings, supports and clamps, including drilling hole in wall to route the drain pipe with 6mm thick nitrile rubber insulation. 25mm
Supply and fixing of drain piping in hard PVC with all fittings, supports and clamps, including drilling hole in wall to route the drain pipe with 6mm thick nitrile rubber insulation. 32mm
Supply and fixing of drain piping in hard PVC with all fittings, supports and clamps, including drilling hole in wall to route the drain pipe with 6mm thick nitrile rubber insulation. 40mm
Supply and drawing Control Cable in suitable size PVC conduit between the indoor units & outdoor units. 2C x 0.75 Sq.mm Shielded Braided PVC inner sheathed, copper conductor, communication cable from indoor to outdoor units & between central controller.
Supply, fabrication and installation at proposed location of MS base frame ( for VRF machine Out Door Unit).The same shall be fabricated form 100mm wide "C" channels & shall be painted with one coat of primer and 02 coat of black enamel paint.
VOLGA AIR TECHNOLOGIES (BID ID -766490)
NAQVI BROTHERS (BID ID -764663)
Anoop Refrigeration (BID ID -766507)
M/s. PRANAM HVAC ENGINEERING PVT. LTD. (BID ID -765963)
Ingenious Industries (BID ID -764815)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid