Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | L1 | Accepted-AOC Acceptance | |
| 2 | L2₹19.2 L+₹3.7 L (24.0%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than L1 | |
| 3 | Rejected-Technical 0 | - | Rejected-Technical Ineligible as not meeting requisite NIT provisions | |
| 4 | Rejected-Technical | - | Rejected-Technical Ineligible as not meeting requisite NIT provisions | |
| 5 | Rejected-Technical 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | - | Rejected-Technical Ineligible as not meeting requisite NIT provisions |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
6 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (I) (CG) Ratnagiri
Military Engineer Services Garrison Engineer (I) (CG)Ratnagiri SLUY Shed Plot, W19-23, MIDC Mirjole, Ratnagiri - 415 639
PROVISION OF COOLING APPLIANCES AT ICGS REPLACEMENT OF SECURITY STRRET LIGHT POLES AND DECORATIVE LIGHT WITH FITTINGS AT ICGAS RATNAGIRI
2021_MES_472535_2
8140/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RATNAGIRI
As per the tender document
8 documents required · 8 mandatory
₹500
GE (I) (CG) RATNAGIRI
₹30,000
Yes
23 Dec 2021
16 Oct 2021
8 Nov 2021
16 Oct 2021
6 Nov 2021
23 Oct 2021
60 days
Amount
Excavation in trenches in soft/disintegrated rocks not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth but not exceeding 3.0 mtr depth and getting out in soft/disintegrated rock including trimming odf sides and bottom of trenches for pole foundations complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming excavated soft/disintegrated rocks in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site.
Removing excavated surplus soft/disintegrated rock obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L, clean, dry, unwashed sand filled in trenches / ducts for cushioning to cable including punning complete all as specified. Note : The depth of sand cushion after punning shall be measured.
Supplying and laying un-reinforced pre cast concrete cable cover of class LV type 1 flat size 250 mm x 150 mm x 40 mm fixed in replacement of any type bricks or PCC covers all as specified and directed.
Supply, laying, jointing and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6sqmm 2core all as specified and directed.
Material and labour steel tubular swaged poles complete with cast iron based plate , finial taper specified type 410 (SP-31) 9 metres long. Taking down existing street light fitting of any kind from existing UNSV electrical pole and installing the same on new poles including 40 mm diameter light grade pipe bends at 120 degree (if required) for fitting street light poles with clamps including new wire 2.5 sqmm copper conductor wire upto fitting and SMC box of 185mm x 165mm x 100mm internal size with hinged door (L) with 1 No PVC connector 4 Way 16 Amps bus bar and 1 No MCB SP 6 Amps including Fixing bracket, nut and bolts etc. complete all as specified and directed.
Supply and fix of LED post top lantern light, 25 watt,240 V, 50 Hz led efficiency lumens/watt > 100, power factor- 0.95, IP 55/65 ,Surge protection > 2KV ,weatherproof with aluminum housing, clear acrylic diffuser, cast aluminum pole-cap Model catalogue no.SZPGPMX025 or equivalent in other makes given in PS complete with accessories suitable for OD of ø50 mm pipe as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, mass concrete and filling etc complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation, mass concrete and filling pole etc complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles complete all as specified and directed.
Supply and fix galavanised steel tubes, light grade as cable protection laid on trench/floor fixed on pole/wall etc of 40 mm as specified and directed.
Supply, installation commissioning of water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity storage capacity of 120 ltr and normal cooling 60 ltrs per hour, all connection in and out complete with pcc platfirm for water cooler complete all as specified.
Supply and fix refrigerator, electric driven (single phase), capacity more 270 Litres.BEE 4/5 star rated double door and moisture balance crisper with stand pvc complete all as specified and directed.
Supply and fix refrigerator electric driven single phase capacity up to 360 Ltrs BEE 4/5 star reated with pvc stand complete all as specified
Supply, installation , commissioning of Glass top deep freezer single phase 240 volt, 50 Hz 320 ltr cap having single door all as specified
Supply and fix desert cooler electric driven (single phase )having normal air flow capacity of 4000 Cu M per hour (or nearest size ) plastic/ PVC body all as specified.
Supply and fix desert cooler electric driven (single phase )having normal air flow capacity of 5000 Cu M per hour (or nearest size ) plastic/ PVC body all as specified.
S&F Exhaust fan AC single phase 230 volts of size 380 mm sweep steel body with louver shutter providing holes including grouting nut bolts complete all as specified and directed at site
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air coold indoor type & designed for input variation between 150V to 280 V with output voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 2.0 KVA all as specified.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air coold indoor type & designed for input variation between 170V to 250 V with output voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 1.0 KVA all as specified.
ANSARI REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .