CWE Patiala
HQ CWE PATIALA Bldg No 26 New Lal Bagh Patiala
UPGRADATION OF TRANSFORMERS AT CERTAIN LOCATION UNDER GE NORTH PATIALA
2020_MES_360791_1
8320/PAT/T-28/E8
Open Tender
Civil Works
Lump-sum
180 days
Patiala
As per cover 1
6 documents required · 6 mandatory
₹1,000
Yes
GE NORTH PATIALA
₹1.6 L
Yes
20 Aug 2020
14 Jul 2020
13 Aug 2020
14 Jul 2020
11 Aug 2020
28 Jul 2020
14 Jul 2020 - 21 Jul 2020
Amount
Schedule 'A'Section-I (EXINTERNAL ELECTRIFICATION WORKS)
Total amount of Sch 'A' Sec I (ExInternal Electrification Works)
Schedule 'A'Section-II (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Material and labour for disconnecting of 300 kVA transformer from foundation carefully after taking out necessary electrical connection and depositing to MES store yard all as specified and directed at site.
Material and labour for disconnecting of 200 kVA transformer from foundation carefully after taking out necessary electrical connection and depositing to MES store yard including demolition including dismantling 02 Nos stay assembly all as specified and directed at site.
Material and labour for disconnecting of 63 kVA transformer from foundation carefully after taking out necessary electrical connection and depositing to MES store yard including demolition including dismantling 02 Nos stay assembly all as specified and directed at site.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 Sqmm 3 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 Sqmm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 500 Sqmm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.0 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 Sqmm 3.5 core all as specified and directed.
Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 mm bore GI tubing and cable etc complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 80 mm bore GI tubing and cable etc complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 100 mm bore GI tubing and cable etc complete all as specified and directed.
S& F Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc all as specified and directed.
S & F factory made sheet distribution board, protection class IP-42 for multiphase out going suitable for mounting MCCBs as incomer of rating 63 Amp, confirming to relevant IS with minimum 200 Amp copper bus bar ,single metal door including connections with copper thimbles as required,415 Volts AC supply all as specified and as directed.
Cutting of wall/hard standing for laying of cables and making good the existing surface with using PCC type B1 (1:2:4) using 20mm graded aggregate excavation and earth work complete all as specified and directed
LT Air Circuit Breaker 4 Pole, 415V, with Manual Draw out type microprocessor release of capacity 630 Amps,50KA all as specified and directed.
Supply installation, Testing and commissioning LT feeder piller board as per designed and approved by GE outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volts 50 Hz factory fabricated, made of 3.0 mm thick CRCA sheet , CPRI approved and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gasket for manual flow of air with canopy, inner compartment made out of 2mm thick CRCA sheet duly compartmentalised suitable for ACB capacity 630 Amprs incoming and outgoing with lockable arrangement fixed on PCC foundation complete all as specified and directed. Note : PCC shall be measured and paid separately
M&L for expanded metal cut to length bend to shape required with and annealed miled steel not less than 0.9 mm dia including fixed with galvanised steel stapples or welded with supporting steel members. Weight XPM is not less than 3.15 Kg/Sqm complete all as specified. Note:MS work required to fixed XPM mesh shall be measured and paid seperately.
Material and labour for removing old plaster from transformer foundation carefully after taking out necessary electrical shut down and despersal of removed material as indicated by competent authority all as specified and directed at site.
R D Bansal
Jawandha Enterprises
SKYLARK INDUSTRIES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .