Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC | ₹25.3 L Quoted ₹26.3 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹24.5 L−₹1.8 L (6.79%)Rejected-Finance | ₹24.5 L−₹1.8 L (6.79%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹28.8 L+₹2.5 L (9.54%)Rejected-Finance | ₹28.8 L+₹2.5 L (9.54%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹30.1 L+₹3.8 L (14.6%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | ₹30.1 L+₹3.8 L (14.6%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹31.6 L+₹5.3 L (20.4%)Rejected-Finance | ₹31.6 L+₹5.3 L (20.4%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Nov 2024, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR
REPAIR / MAINTENANCE OF LT OVERHEAD LINE, UG CABLE AND CONTROL PANELS AND OTHER MISC E/M CONNECTED WORKS IN DOMESTIC AREA AT 7 AFH KANPUR.
2024_MES_681537_1
8725/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE(AF) EM Chakeri Kanpur
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(AF) EM Chakeri
₹60,000
Yes
20 Mar 2025
26 Oct 2024
28 Nov 2024
28 Oct 2024
23 Nov 2024
11 Nov 2024
Amount
Excavation in trenches (soft & loose soil) n.exc. 1.5 m wide and n.exc.1.5m in depth for laying of UG Cable and getting out insoft /loose soil all as specified & directed by Engr-in-Charge
Returning filling in and including spreading leveling watering and well ramming in layers not exceeding 25 cm insoft/loose soil all as specified and directed.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc 1.5 m above starting point in soft/loose soil complete all as directed by Engineer in Charge.
M&L for spreading & leveling dry clean Ganga sand in trenches for cushioning UG cable complete all as specified and directed. Note: Punned thickness of sand shall be measured for payment purpose.
M&L for sub class 'B' bricks, old size ,laid in trench with width equal to length of whole birck for cable protection complete all as specified and directed.
M& L for boring through existing road with trench less method for passing of UG cable all as specified and directed.
Supply , laying and replacement of unserviceable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 400 sq mm 3.5 core ,laid in trenches/ducts /encased in GI pipe /fixed to pole including taking out of existing unserviceable cable all as specified and directed.
All as per item no. 7 here in above but for electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 240 sq mm 3.5 core.
All as per item no. 7 here in above but for electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 185 sq mm 3.5 core
All as per item no. 7 here in above but for electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 150 sq mm 3.5 core
All as per item no. 7 here in above but for electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 120 sq mm 3.5 core
All as per item no. 7 here in above but for electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 95 sq mm 3.5 core
All as per item no. 7 here in above but for electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 70 sq mm 3.5 core
All as per item no. 7 here in above but for electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 50 sq mm 3.5 core
All as per item no. 7 here in above but for electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 35 sq mm 3.5 core
All as per item no. 7 here in above but for electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 25 sq mm 4 core
Taking down HT/LT cable of any size and any discription and Re laying of serviceable cable after necessary repair of cable fault etc. all as directed by Engineer in Charge. (Note: Excavation , earth work, sand cushionning, bricks etc shall be measured seperatly under respective item of Sch.)
Supply, laying in replacement from trenches /fixed on pole / wall GI pipe of 80 mm dia light grade,IS-1239 marked with required size of flat iron clamp complete with bolts, nuts and washers of sizes 80 mm bore complete all as specified and directed.
Supply, laying in replacement from trenches /fixed on pole / wall GI pipe of 50 mm dia light grade,IS-1239 marked with required size of flat iron clamp complete with bolts, nuts and washers of sizes 50 mm bore complete all as specified and directed.
Supply,Joining , commissioning and testing in replacement of Heat Shrinkable End Termination Joint Out door type and suitable for cable of size 120 to 185 sqmm 3 core complete with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable all as specified and directed.
Supply, Joining , commissioning and testing in replacement of Heat Shrinkable Straight Though Joint suitable for cable of size 120 to 185 sqmm 3 core complete with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable all as specified and directed.
Supply, Joinging , commissioning and testing in replacement of Heat Shrinkable End Termination Joint Out door type and suitable for cable of size 240 to 300 sq mm 3 core complete with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat Shrinkable Straight Through Joint suitable for cable of size 240 to 300 sq mm 3 core complete with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat Shrinkable Type Straight Through Joint suitable for cable of size 25 to 50 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat Shrinkable Straight Through Joint suitable for cable of size 70 to 120 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat Shrinkable type Straight through joint suitable for cable of size 150 to 185 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat Shrinkable type straight through joint suitable for cable of size 240 to 300 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat shrinkable type straight through joint suitable for cable of size 400 to 500 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat shrinkable type End joint suitable for cable of size 25 to 50 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply,Joinging , commissioning and testing in replacement of Heat shrinkable type End joint suitable for cable of size 70 to 120 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat shrinkable type End joint suitable for cable of size 150 to 185 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat shrinkable type End joint suitable for cable of size 240 to 300 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat shrinkable type End joint suitable for cable of size 400 to 500 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
M& L for earthing complete with galvanized steel earth plate electrode 600mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip 25x4mm dia by means of GI bolts, nuts, check nuts and washers complete all as shown in electrical plate No.3 of SSR Part-I (2009) connected to earth test point all as specified or indicated including testing on completion including construction of earth pit chamber with PCC in (1:3:6) type C-2 cement concrete, RCC (1:2:4) type B0 using 12.5mm graded stone aggregate, reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip 25x4mm protection etc complete all as specified and directed by Engr-in-Charge. (Note: Earth lead up to 7.5mtr and neceesary earth work shall be deemed to be included with quoted unit rate)
M&L for in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed by Engineer in Charge.
Supply, laying in replacement Synthetic Rubber Insulated Mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m all as directed by Engineer in Charge.
S& F in replacement insulator pin type porcelain vitreous white brown or green including galvanized MS spindle two GI Washers and one GI Nut 150 mm height 150 mm dia for 11000 volts grade complete all as specified and directed .
Supply, installation, commissioning and testing in replacement powder coated factory made panel board outdoor type CPRI approved confirming to IP 64 protaction, of suitable size made of Robust steel sheet construction made from 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate all as directed by Engineer in charge with following accessories (Note :- Old unserviceable Panel Board (including its accessory) is deposted in MES Store Yard of AGE EM-I, AF Chakeri, shall be taken on charge through proper RVrs being property of department)
M&L for replacement of LT panel board outdoor type factory made and tested (CPRI approved) 415 volts 3 phase 4 wire 50 HZ AC supply having busbar chamber 800 Amps Aluminium strip TPN, installed on porcelain insulators, and copper conductor wiring , the panel shall be dust and vermin proof and made up of 3.15 mm CRCA mild steel sheet and 40x40x6 mm thick angle iron frame work , powder coated finish over one coat of red oxide primer out side and in side, front and rear opening type, with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cables, IS -694 marked of adequate size but not less than 4 sq mm and suitable to accomodate and including the following acessories:- (Note :- Old unserviceable Panel Board (including its accessory) is deposted in MES Store Yard of AGE EM-I, AF Chakeri, shall be taken on charge through proper RVrs being property of department).
Disconnecting cable connection of LT panel /Feeder Pillar Box of any size and capacity ,cleaning thoroughly with vaccum cleaner and CRC and shifting care fully to new location , making cable connection for incoming and out going cables along with required cable glands and lugs and foundation work at new location all as specified and directed. (Note: Necceassry transport for shifting of Panel/Feeder Pillar Box shall be arranged by the contractor, this shall be deemed to be inclusive in their quoted unit rate)
S & F in replacement of PVC insulated heavy duty electric weather proof flat twin core cable with aluminium conductor 1100 Volts grade, cross sectional area 6 Sqmm all as specified and directed by Engineer in Charge.
S & F in replacement of PVC insulated heavy duty electric weather proof flat twin core cable with aluminium conductor 1100 Volts grade, cross sectional area 10 Sqmm all as specified and directed by Engineer in Charge.
S & F in replacement of PVC insulated heavy duty electric weather proof flat twin core cable with aluminium conductor 1100 Volts grade, cross sectional area 16 Sqmm all as specified and directed by Engineer in Charge.
S & F in replacement of initially charged battery 12 volts, 150 AH having min 48 Month warrantee including filling with necessary electrolyte solution complete all as specified & directed by Engineer-in-charge. (Note:- Serial number of Battery as mentioned in Warrentee Card as provided by manufecturer's along with original purchage voucher shall be entered in MB)
S & F in replacement On load change over switch, 800 Amps, 4 pole with sheet metal enclosure, panel mounted type with fixing arragement in existing wall angle iron frame 50x50x4mm with welding work and PCC works etc including making electrical connections complete all as specified and directed.
S & F in replacement On load change over switch, 630 Amps, 4 pole with sheet metal enclosure, panel mounted type with fixing arragement in existing wall angle iron frame 50x50x4mm with welding work and PCC works etc including making electrical connections complete all as specified and directed.
S & F in replacement On load change over switch, 400 Amps, 4 pole with sheet metal enclosure, panel mounted type with fixing arragement in existing wall angle iron frame 50x50x4mm with welding work and PCC works etc including making electrical connections complete all as specified and directed.
S & F in replacement On load change over switch, 315 Amps, 4 pole with sheet metal enclosure, panel mounted type with fixing arragement in existing wall angle iron frame 50x50x4mm with welding work and PCC works etc including making electrical connections complete all as specified and directed.
S & F in replacement On load change over switch, 200 Amps, 4 pole with sheet metal enclosure, panel mounted type with fixing arragement in existing wall angle iron frame 50x50x4mm with welding work and PCC works etc including making electrical connections complete all as specified and directed.
M&L for detection of HT/LT fault by using fault locator machine highering from civil authority complete all s specified and directed by Engr-in -Charge. (Note :- In one length of cable from Panel / DB / Transformer to Panel / Transformer all faults considered as single job complete all as specified and directed. Report generated by Machine shall be kept on record)
M&L for repairs to phase sequence controler of any capacity & of any make by removing out the burnt wiring from the panel after taking proper electric shut down & disconnecting the cable, checking it thoroughly for working at auto & manual mode and rectifing them, including overhauling of the contractor, replacement of wornout connector,wiring, nuts & bolts,minor part of contactor etc reassembling , re-installation ,testing & commissioning complete all as directed by Engineer-in- charge.
Supply and fixing in replacement of single phase preventer for phase controler all as specified & directed by Engr-in-charge.
Supply and fixing in replacement of Contactor MNX 110 all as specified & directed by Engr-in-charge.
Supply and fixing in replacement of Contactor MNX 250 all as specified & directed by Engr-in-charge.
Supply and fixing in replacement of phase sequence relay suitable up to 200 Amp phase sequence corrector all as specified & directed by Engr-in-charge.
M&L for replacement of Air Circuit Breaker (ACB) of capacity 800 Amps 4 pole with breaking capacity 50 kA with micro processor release (Mannual drawout type) complete all as specified and directed by Engr-in-Charge. (Note : Necessary addition /altration required to adjust ACB in the existing slot of panel shall be done by the contractor and no extra payment will be made to the contractor. Serial Number of ACB shall be entered in MB as per Original Purchase Voucher).
S&F in replacement of MCCB, 4 pole adjustable type 50 KA, 630 Amps complete all as specified and directed by Engineer in Charge. )Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor).
M & L for replacement of MCCB, 4 pole adjustable type 36 KA, 500 Amps complete all as specified and directed by Engineer in Charge.Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 4 pole adjustable type 36 KA, 400 Amps complete all as specified and directed by Engineer in Charge. Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 4 pole adjustable type 36 KA, 350 Amps complete all as specified and directed by Engineer in Charge. Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 4 pole adjustable type 25 KA, 250 Amps complete all as specified and directed by Engineer in Charge. Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 4 pole adjustable type 25 KA, 200 Amps complete all as specified and directed by Engineer in Charge. Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 4 pole adjustable type 25 KA, 160 Amps complete all as specified and directed by Engineer in Charge.Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 4 pole adjustable type 25 KA, 100 Amps complete all as specified and directed by Engineer in Charge. Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 4 pole adjustable type 16 KA, 63 Amps complete all as specified and directed by Engineer in Charge. Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 3 pole adjustable type 36 KA, 250 Amps complete all as specified and directed by Engineer in Charge.Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 3 pole adjustable type 36 KA, 200 Amps complete all as specified and directed by Engineer in Charge. Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor..
M & L for replacement of MCCB, 3 pole adjustable type 36 KA, 160 Amps complete all as specified and directed by Engineer in Charge.Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
M & L for replacement of MCCB, 3 pole adjustable type 16 KA, 125 Amps complete all as specified and directed by Engineer in Charge.Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
Clearing away all grass vegetation ,saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance soft/loose soil and getting out including sprinkling anti vegitation chemical for complete area with spray machine complete all as specified & directed. Note: Minimum two number cutting away per sqm area shall be done in entire contract period and for payment purpose two cutting per sqm shall be measured
S & F in replacement sheet metal enclosure suitable for fixing 4 pole MCCB of any capacity mounted type with fixing arragement in existing wall / angle iron frame incl welding work etc including making electrical connections complete all as specified and directed.
M&L for in replacement of bus bar chamber, fixed on wall, 8 ways, 250 Amps ,415 V powder coated, water & vermin proof , IP-66 protection duly provided with front openable door incl provision of TPN copper bus bar heat shrinkable colored PVC sleeve coated for phase and neutral complete all as specified and directed. (Note:- Old unserviceable enclosure is property of department and submitted to store yard. shall be taken on charge with proper RVrs)
NEW TECH ELCTRICALS (BID ID -3166847)
VEE KAY ENTERPRISES (BID ID -3167377)
Bharat Sales Corporation (BID ID -3166817)
AARADHIRAJ ASSOCIATES (BID ID -3171273)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .