Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹10.5 L+₹9,265.70 (0.89%)Rejected-Finance MIRZAPUR MUMTAZ NAGAR AYODHYA AYODHYA UTTAR PRADESH 224001 | AYODHYA | UTTAR PRADESH | 224001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹12.3 L+₹1.9 L (18.7%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹10.9 L
EMD Value
₹10,860
Closing Date
30 Mar 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer EWC Ayodhya
Office Of Superintending Engineer EWC Ayodhya
28/SE/EWC/AYO/2020-21
2021_MVVNL_572858_1
28/SE/EWC/AYO/2020-21
Open Tender
Electrical Works
Item Wise
90 days
amethi
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER ELECTRICITY WORKS CIRCLE
₹10,860
1 Apr 2021
25 Mar 2021
30 Mar 2021
25 Mar 2021
30 Mar 2021
25 Mar 2021
180 days
Amount
Safe Loading, Carriage and then safe unloading of the following material from Store Centres Under the jurisdiction of EEESD Ayodhaya to dump site proper stacking.
33/11 KV 5 MVA T/F
33 KV Bus Isolator
33 KV Post Insulator
33 KV Lightening Arrestor
90 lbs rail Pcs for T/F ( 44.64 Kg/m)
33 KV VCB 800A, 750 MVA
Singe/Double T/F control pannel
C.T. O/D 33 KV CTR 200/100/1-1A
11 KV Incoming switch gear 600/300/5A, 350 MVA
11 KV Bus coupler
Out going 11 KV switch gear 200/100/5A 250 MVA
11 KV 3 Core Cable 3x300 mm XLPE
11 KV 3x185 mm XLPE
11 KV cable jointing kit indoor 3x300 sq.mm. XLPE
11 KV cable jointing kit outdoor 3x 300 sq.mm. XLPE
11 KV cable jointing kit indoor 3x185 sq.mm.
11 KV cable jointing kit outdoor 3x185 sq.mm.
ACSR Dog Conductor
M.S. Channel 125x65 (for Structures)
M.S. Angle 75x75x8 (for Structures)
ST Pole 11Mtr
M.S.Angle iron 65x65x6 bracing
11 KV Top channel 100X50X2240 mm
Stay Wire
11 kv disc insulator T&C type
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectioal Double pole for 11 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 1 No. Top channel of 100x50x6 mm size 2240 mm, Disc Fitting 6 No., Bracing angle 1set. ,11 kv Disc insulator T & C 06 No. and 3 No.11 kv Pin insulator with pin etc. as per norms. (Contractor shall provide 3 No. G.I. Pin, E- Bracket 3 No., necessary clamps, Disc Fitting 6 No., Nut - Bolts Washers etc.)
Earthing of Pole STP/PCC by 6 SWG Wire by providing and fixing of 20 mm dia' earthing rod 2.550 Mtr. long as per norms complete in all respect. (Contractor shall provide all the material Like Earthing rod, 6 swg wire, Earthing clamps and nut & bolt etc.)
Bus Isolator Structure Fabrication of isolator structures 3.5 mtr in height as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.9 x 0.3 Mtr providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with runner of isolator in proper allingment level and plumb. Both plinths of the Isolator structure shall be properly finished with smoothening of edges and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs (All the civil & other materials will be supplied by the contractor Except steel).
Installation of Heat Shrinkable Type cable jointing kits of following types/sizes for 11 XLPE Cable.
(b) Fixing of 11 KV 3x185 sq. mm Indoor End Terminations (jointing kit supplied by dept.)
(b) Fixing of 11 KV 3x185 sq. mm Outdoor End Terminations (jointing kit supplied by dept.)
(b) Fixing of 11 KV 3x300 sq. mm Indoor End Terminations (jointing kit supplied by dept.)
(b) Fixing of 11 KV 3x300 sq. mm Outdoor End Terminations (jointing kit supplied by dept.)
Lightening Arrestor Structure Fabrication & Erection of Lightening Arrestor as per drawing No. RES 39 Digging of 2 No. Pits of size 1.075 x 0.3 x0.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC (cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr x 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure's in proper allingment level and plumb. Both plinths of the structure shall be properly finished with champering of edges and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs through connect L.A as per norms (All civil & other materials will be supplied by the contractor Except steel as channel & angle).
Post Insulator Structure Fabrication & Erection of Post insulator as per norms Digging of 2 No. Pits of size 1.075 x 0.3 x0.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC (cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr x 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure's in proper allingment level and plumb. Both plinths of the structure shall be properly finished with champering of edges and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs as per norms (All civil & other materials will be supplied by the contractor Except steel as channel & angle).
Laying & Dressing of 3x185 / 3x300 sq. mm XLPE Cable underground Single Circuit. Laying &Dressing of 11 KV 3x185 / 3x300 sq .mm XLPE Cable in underground from outgoing switchgear to Double Pole and Power T/F in trench 900 mm deep, 450 mm wide, providing 150 mm fine sand cushion bench and 150 mm fine sand cusion above the cable.The cable shall be duly protected by the 1st class bricks two either side third on the top of the cable, laid in series one after the other, the work includes supplying of fine sand and bricks, refilling and ramming of the left out soil, closing the trench and levelling. Spare cable shall be left and burried in the trench in the safe of rings at both ends. Cablelaying work includes unrolling, cutting, meggering and sealing both end of the cable. (All the materials will be supplied by the contractor)
Installation of Bus Isolators Assembling and installation of line isolator/ Bus isolator on the Isolator structure, adjusting of opening mechanism in proper alignment so as to ensured smooth operation of the same. In case of line Isolator/ Bus Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.
Installation of Lightening Arrestors Assembling and installation/ mounting of 03 Nos.Lightening Arrestors on the L.A. structure complete and making earth connection ( Separate ) and line connections for L.A. The work includes fabrication for proper fixing if required.
Installation of Post insulator Assembling and installation/ mounting of 12 Nos.Post insulator on the Post insulator. structure complete and making earth connection ( Separate ) and line connections for Post insulator. The work includes fabrication for proper fixing if required.
Hoisting of 11 KV Cable on existing/erected support with provision of MS Pipe 150 mm dia 3 mtr long suitable for 3x185 sq mm cable fixing of proper support and its clamping, providing long barral lugs 3 nos and P.G. Clamps for weasal conductor as per RESSPO Norms. (All material will be supplied by the contractor like M.S Pipe , P.G. Clamps, Al. Lug And Supporting Angle 65x65x6, 2240 mm).
Supply of following materials.
(A) Hnad Gloves (Supplied by the contractor)
(B) Rubber mat one side chequered and other side plain (Supplied by the contractor)
Hoisting of 11 KV Cable on cable stand and connecting in Switchgear room . (All material will be supplied by the contractor).
Cable stand Structure Fabrication & erection of 11 KV Cable Stand made of 02 No. M.S chanel 125x65x6 mm 3 Mtr. Jointed to each other by M.S Channel horizontally and also jointed to each other by means of 05 No. M.S Strip 50x6 mm of size 150 mm long each by welding at actual distance interval as per norms. And grouting in block of 300x300x700 completely providing 02 no. cable clamps also and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs. (All the materials will be arranged by the contractor such that clamps nut bolts and civil materials except M.S channel.)
Plinth For VCB Construction of plinth of size (2.0x1.5x0.9 (Mtr.) suitable for errection of super structure for 33 kv VCB including grouting of Anchor bolts in proper allignment and level. Scope of works includes excavation of foundation base concreting in CC 1:6:12 (cement,fine sand and bricks ballast) 1st class bricks work in cement mortor of ratio 1:4 CC in ratio 1:4:8 and RCC works in ratio 1:2:4 (cement, coarse sand and stone grit of 20 mm gauge) as per drawing
Installation of 33 KV VCB Installation of 33 KV 750 MVA 800 Amp VCB on 33 KV VCB structure along with earthing by G.I. strip 50x6 mm size with main earth mat of Switchyards complete in all respect including commissioning & testing.
Fabrication & Errection of CT Structure & Its Installation Fabrication of CT Structure as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.3 x0.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr X 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure's in proper allignment level and plumb. Plinths of all the structure shall be properly finished with champering of edges etc. Installation of 3 Nos CTs of ratio 200/100/1A on the CTs structure. The work includes fabrication for proper fixing if required and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs. (All the material will be supplied by the contractor except Steel Section and 03 No. CT)
Construction of control cable trench of 300 mm wide and 300 mm deep with MS strip at an interval of 0.5 mtr. With brick work 1:4:8 in foundation 12 mm thick plaster of 1:4 cement coarse sand for finishing along with MS Angle running on both edges of the trench. (All the material will be supplied by the contractor)
Supply & Laying of 6x2.5 sq.mm. Sq. control cable from power T/F to controle board in the cable trench/ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material. (All the material will be supplied by the contractor)
Supply & Laying of 4x2.5 sq.mm. Sq. control cable from power T/F to controle board in the cable trench/ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material. (All the material will be supplied by the contractor)
Supply & Laying of 2x2.5 sq.mm. Sq. control cable from power T/F to controle board in the Cable trench/ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material. (All the material will be supplied by the contractor)
Construction of trench cover of 600 mm long and 75 mm thick for cable trench Including cost of material, labour and T&P. (All the material will be supplied by the contractor)
Painting of All Old & New Structures with one coat of ready mixed primer and 2 coats of AL.Paint of good quality including cost of material, Labour and T&P complete in all respect. (Contractor shall provide all materials)
Grouting of following structure by digging of pit 1.5 Mtr/1.83 Mtr deep for 9.0 Mtr PCC / 11 Mtr STP respectively, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.
11 Mtr ST Poles
Supply and fixing of a stone pad of size 300x300x75 mm at PCC/STP Bottom of the pit ( Contractor shall provide all materials)
Installation of 33 KV Single T/F control pannel Shifting carefully and safely installaltion 33 KV Single T/F control pannel in control room including grouting ,commissioning and testing control circuit. Its earthing by 35x6 mm G.I strip as per procedure with earth mat also.
Breaking the concrete fencing/Boundary Wall in the Switchyard of sub station for moving 05 MVA Transformer in switchyard and after complete the work covered and restore the wall.
Boring Type Earthing Earthing by way of boring lowering of 'B' Class G.I Pipe 50 mm dia' from ground upto the water level (min 40 mtr. Deep) as per standard practice.It will be connected to G.S strip 50x6 mm (Providing & laying of G. Strip including cutting, welding, bending etc.) For equipment (L.A, T/F, C.T, VCB, etc.) .The earth strip will be welded to the G.I Pipe. The work also includes Cap & Clamps for pouring water, the cost of all materails with all labour & T&P etc. Complete in all respect.(All the materials will be supplied by the contractor).
Digging and locking of earth mat and outdoor all structures earthing by M.S ,G.I Flat 50x6 mm .The includes cutting bending.(All the materials will be supplied by the contractor)
Erection & Installation 33/11 KV 5 MVA Transformer Erection and installation of 33/11 KV 5 MVA T/F in a leveled position on the plinth. The work incudes shifing of T/F to the site of installation within the S/S premises, assembling fixing and fitting of all accessories and filling of T/F oil to the desired level and insuring that there is no leakage.All the jump ring & connection are including in the scope of work and complete testing.
Plinth of 5 MVA 33/11 KV T/F Construction of Plinth of size 3.4x3.46 Mtr. For 5 MVA T/F having 0.4 Mtr. Above ground level. The work including excavation in CC 1:6:2 ratio (Cement, fine sand & Bricks ballast) first class bricks work in cement mortor of ratio 1:4 foundation CC in 1:4:8 ratio (cement fine sand and bricks ballast and RCC working ratio 1:2:4 ( cement coarse sand stone grit of 20 mm guage using M.S Bar of 10 mm dia (Tor) reinforcement incluing its cutting bending and binding in required shape. The work also includes laying of 2 no. 3.46 Myt. long each rail places complete with cutting , Welding & proper fitting etc.The plinth will be made as per drawing and shall be plastered/ finished on top and sides of the plinth.
33 KV Bus Bar & Stringing. Stringing of 33 kv Bus Bar by using and laying of ACSR Dog conductor including making vertical/horizontal (Y-Shape) jumper connection through PG Clamps and connecting all the equipments (Bus isolator, P.I, C.T, VCB, L.A &T/F) with each other through connecting clamps.( All the materials will be supplied by the contractor.)
Neutral stand Fabrication and grouting of M.S Channel 100x50x6 mm L shape & in proper size and allignment to provide support for the two separate earthing strips for pwer T/F neutral including supply & fixing of two No.Flexible copper bonds foe neutral earthing.
Supply fixing & erection of 24 Volt Battery & Battery charger with cabinet
Installation of Switchgears in control room (A) Shifting carefully and safely 11 KV I/C ,O/G switchgear & 11 KV Bus Coupler from outside of the switchgear room, including grouting the two No. 100x50x6 mm channels pieces (each 800 mm long including cutting to size) and foundation bolts in 1:2:4 CC (incuding cutting of CC of the floor and finishing of floor) as per direction of Engineer in charge, placing and fixing of switchgears on foundation providing G.I Nuts & Bolts of proper size in proper position and allingnment and checking, complete work with mounting of P.T on Incoming S/G.
(B) Fixing and making bus bar connections in between all switchgears after cleaning and tapping with .H.T Tap , empire tape and PVC tape properly,providing and fixing of 6 mm thick bakelite seperators and plugging of all opening & holes with palstic compound complete work including cost of all materials strictly to the satisfaction of site in charge and complete testing.
Fixing of barbed wire on pole Supply and fixing of barbed wire on the pole above 2750 mm ground level. Barbed wire wrapped for a distance of 0.9 mtr. with a pitch of 13.mm at a height. (All materials supplied by the contractor)
Fixing of Danger board . Supply and fitting of Danger board of size 250x200x2 mm 3650 mm above ground level as per Respo norms.RESPO Drawing No-55
Painting of poles Painting of 11 Mtr S.T. pole with one coat of red oxide, two coats of enamel paint ISI mark. (All required material will be supplied by the contractor)
Hindustan Electric Work
M/s Shukla Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .