| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹36.6 L+₹4.9 L (15.5%)Rejected-Finance 00 C O PARMOD SINGH BAKTA BARHI CHINTAMAN SITAMARHI BIHAR 843315 | SITAMARHI | BIHAR | 843315 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹37.3 L+₹5.6 L (17.7%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹38.9 L+₹7.2 L (22.9%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹47.8 L+₹16.1 L (50.9%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
13 Jan 2023, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
SPECIAL REPAIR AND REPLACEMENT OF DG SETS, OLD VINTAGE LT UG CABLE , LT PANELS/FEEDER PILLAR BOXES INSTALLED AT VARIOUS LOCATIONS AND MINOR WORK AT AFS MUMBAI UNDER GE AF THANE
2022_MES_565527_1
8235/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
THANE
SPECIAL REPAIR AND REPLACEMENT OF DG SETS, OLD VINTAGE LT UG CABLE , LT PANELS/FEEDER PILLAR BOXES INSTALLED AT VARIOUS LOCATIONS AND MINOR WORK AT AFS MUMBAI UNDER GE AF THANE
8 documents required · 8 mandatory
₹500
GE AF THANE
₹91,000
Yes
18 Feb 2023
26 Nov 2022
14 Jan 2023
26 Nov 2022
13 Jan 2023
2 Jan 2023
26 Nov 2022 - 2 Jan 2023
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in in soft / lose soil all as specified and directed
Excavation in trenches not exc 1.5 mtr wide and not exc 3.0 mtr in depth and getting out in Hard/dense soil all as specified and directed.
Returning filling in , excluding spreading, levelling, watering and well ramming in layers not exc 25cms each layer , complete all as specified and as directed by Engr-in-charge.
Removing surplus soil to a distance not exc 50mtr away and depositing at a point where directed not exceeding 1.5 mtr above the staring point , complete all as specified and as directed by Engr-in-charge.
Supply, spreading in trenches fine cushioning sand for cable protection , 10 cm sand below cable before laying and 15 cm sand after laying the cable and well rammed all as specified and directed. Note : Punned thickness only be measured & paid.
Supply and laying un reinforced precast concrete cable cover class LV, ISI marked type-I, flat size 250mm x 150mm x 40mm laid in trenches , complete all as specified and as directed by Engr-in-charge.
M&L for cement concrete Type B1 1:2:4) (20 mm graded aggregate),coping weathering,slightly rounded or chamfered angles and throating , complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement steel tubular swaged poles type 410 SP-31 (9 meter long) complete with CI base plate and finial taper plug, bolts, nuts & screws , complete all as specified and as directed by Engr-in-charge.
Supply and fixing , in replacement LED street light fitting 100 watt 230V AC , in built SPD 10 KA, Minimum 50000 burning hours outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal managment in multiple optics complete with IP65/66 proctection , complete all as specified and as directed by Engr-in-charge. Note : (i) Light of fitting should be 110 lum per watt (ii) The CRI of the light fitting > 80.
S& F in replacement of GI steel tubing brackets made up of light grade 40mm dia 1.5 meter length and bent to shape at factory of offset angle upto 45 degree for fixing of LED street light fittings including preparing the surface of steel tubing and applying two coats of Aluminium Paint , complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of fibre looping box with connector and MCB SP 2 to 6 Amps of size 250 X 200 X 100 mm including making connections , complete all as specified and as directed by Engr-in-charge.
Supply, laying and testing, in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5core , complete all as specified and as directed by Engr-in-charge.
Supply, laying and testing, in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5core , complete all as specified and as directed by Engr-in-charge.
Supply, laying and testing, in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete all as specified and as directed by Engr-in-charge.
Supply, laying and testing, in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core , complete all as specified and as directed by Engr-in-charge.
M&L Boring hole with trench less technology for under road passing cable and GI protection pipe 80 mm , complete all as specified and as directed by Engr-in-charge.
Supply and fix Galvanized iron steel tubing Light grade of 80mm bore with all fittings as required at site and laid in floors/trenches as in cable protection , complete all as specified and as directed by Engr-in-charge.
Supply and fix Galvanized iron steel tubing Light grade of 50 mm bore with all fittings as required at site and laid in floors/trenches as in cable protection , complete all as specified and as directed by Engr-in-charge.
M&L for cement concrete Type C2 1:3:6 (40 mm graded stone aggregate )in foundation filling and mass concrete , complete all as specified and as directed by Engr-in-charge.
M&L Earthing complete with galvanished steel earth plate electrode 60X60X6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to earthing lead using galvanished iron strip32X6 mm by means of bolts, nuts check nuts andwashers of galvanished iron or steel including PCCpit and CI cover funnel with watering pipe 15mm, wire mesh and copper lugs etc GI protection pipe 40mm of suitable size ordered specified for protection of earthing lead from mechanical injury or temporing.Test point and length of main earthing lead 7.5 meters .On testing after completeion if the desired earth resistance is not obtained the earthing will be redone at no extra cost all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including earth work testing on completion.
Supply and fix post top lantern LED light fitting for 70 Watt complete With all accessories , complete all as specified and as directed by Engr-in-charge.
M&L Cross arms, Bracings support,clams and back plates fabricated from structural steel section including nuts, bolts, washers,welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat , one under coat and finishing coat one under coat and one finishing coat of paint , complete all as specified and as directed by Engr-in-charge.
M&L for copper wire alongwith three single core 1.5 Sqmm FR PVC insulated and sheathed 1100 Volts grade, standed copper conductor ISI marked drawn into fixed in an including PVC insulated (green colour) as earth wire , complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement LED Hanger high bay Light fittings of 120 watts with junction/connection box, in built SPD 10 KA, Minimum 50000 burning hours and including taking out unserviceable light fittings , complete all as specified and as directed by Engr-in-charge.Note : (i) Warranty of fitting should be upto 5 years maint free. (ii) Light of fitting should be 110 lum per watt (iii) The CRI of the light fitting > 80.
M&L in repair for Three single core (submain) FRLS insulated cable with 2 X 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS insulated cable 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit of suitable size including all conduit and fixing accessories, concealed in wall including cutting chases or as required surface conduit/existing conduit and making good disturbed surface to match complete all as specified by Engr in charge.
S&F in repair pressed sheet metal enclosure (MCB DB), single phase and neutral with 100 Amps rated bus bar, Single door type, 2 way , 240 volts, flush on wall all as directed .
S&F MCB in repair single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & connection complete as directed (Make: Legrand Cat Part No. 603233 to 37 or equivalent Make of Seimens/ABB) all as specified by Engr in charge.
Supply, install, testing in replacement and commissioning of factory made and CPRI approved outdoor type floor mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 100 Amps for phases and 100 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.0 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and including comprising of followings acessorties all as specified and directed.INCOMING (a) MCCB 415 Volts, 63 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 35 KA - 01 No (b) Digital volt meter 0-500 Volts-01 (c)Digital Ampere meter 0-100 Amps with and including CTs-01 No OUTGOING (a) MCCB 415 Volts, 32 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 25 KA - 03 Nos (for street light & spare 01) (b) Internal wiring of panel with stranded copper cable of suitable size (c) Neon phase indicating lamp(Set of three)-01 Set (d) Stenceling of pannel board including marking of distribuitions (e) Street light timer, digital type, contactor 63 A, suitable complete.
Supply, install, testing and commissioning of factory made and CPRI approved outdoor type floor mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 400 Amps for phases and 400 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and including comprising of followings acessorties all as specified and directed. INCOMING (a) MCCB 415 Volts, 200 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 35 KA - 01 No (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-100 Amps with and including CTs-01 No OUTGOING (a)MCCB 415 Volts, 100 Amp, rating 4 Pole (triple pole and neutral), (Service Breaking Capacity 25 KA - 03 Nos (b) Internal wiring of panel with stranded copper cable of suitable size (c)Neon phase indicating lamp(Set of three)-01 Set (d) Stenceling of pannel board including marking of distribuitions (e) Street light timer, digital type, contactor 63 A, suitable complete.
M&L for Draining out the old slugs oil from the DG set and replace with new oil as recommended by OEM Mfg , complete all as specified and as directed by Engr-in-charge. NOTE : Draining out of Oil shall be done twice in year each time reffiling/Top up will be measured & paid seperataly.
M&L for Disconnecting old unserviceable battery 12 Volts DC upto 180 AH from Engine & transporting to work shop for refilling electrolite, distilled water, checking of sp gravity complete & initial charging of the battery for 48 hours min, transporting back to site , reconnecting up complete all as directed by EIC at site
M&L Battery 12 Volts DC upto 180 AH suitable to startng of DG set with warrenty of five year complete all as specified & directed
M&L for Battery 12 Volts DC upto 92 AH suitable to startng of DG set with warranty of five year , complete all as specified and as directed by Engr-in-charge.
M&L for Servicing of AMF Panel suitable for 15 KVA DG Set to 75 KVA DG Set including cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, calibration of control relay, replacement of control fuses / MCBs/ LED indicators , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement LED type Indicator , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Control relay 9/11 pin 12 /24 volt DC , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Micro processor unit for automatic and manual function , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Contactor four pole 165 amp coil voltage 230 volt AC, complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Contactor Type ML-4 , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Contactor Type ML-2 , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Change over switch four pole 63 Amp including reconnecting of existing incming & outgoing cables with proper brass glands & lugs , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Change over switch 100 Amp four pole as per existing , complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs onload change over switch complete in sheet steel enclosure and connecting up, mounting on wall / floor of rating 100 Amps TPN 415 Volts , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement MCB type change over switch four pole 63 Amp . , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement CT of ratio upto 150 / 5 10 VA burdan , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Fault Indicator Control Relay Model No SU 01 of RB Electronics of Kirloskar , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Fault Indicator Control Relay Model No KRB 101 of RB Electronics of Kirloskar , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Temperature gauge , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Oil Pressure Guage 0-10 Bar , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Digital Frequency meter , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement DC Volt meter 0 to 30 volt , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement DC ammeter 0 to 2 amp , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Excitation coil for 75 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement AVR card for 75 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement AVR card for 15 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L for Servicing of Self Starter 12/24 Volt DC for 75KVA DG Set, dismantling complete,& replacement of solenoid field coils. cleaning the cummutator strips including replacing the bearing, bends pinion re-assembling, connecting and testing , complete all as specified and as directed by Engr-in-charge.
Ditto as Srl Item No 58.00 above but for capacity for 15 KVA DG SET
Ditto as Srl Item No 58.00 above but for capacity for 40 KVA DG SET
M&L for in replacement self starter 12 volt DC for 75 KVA DG SET including all accessories , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement self starter 12 volt DC for 15 to 40 KVA DG SET including all accessories , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement oil Feed Pump for Aquastic DG SET for capacity 15 to 75 KVA , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement alternetor for battary charging 12/24 volt DC complete with all accessories , complete all as specified and as directed by Engr-in-charge.
M&L Draining out the Water from the radiator, dis-mantling the leaking radiator assembly complete from the engine body, transporting to workshop, cutting the bottom chambers, repairing the damaged pipes, brazing the leaking portions ,descaling / clearing all the blocked pipes including repairing the fins, brazing the bottom chambers, testing the radiator for leaks, transporting the same to the site and re-fixing and testing complete in the presence of Engineer-in-charge for Capacity 75 KVA/82.5 KVA
Ditto as Srl Item No 65.00 above but for 15 to 40 KVA DG Set.
M&L for Taking down carefully Old rusted silencer & exhaust pipe from engine scraping & cleaning in side & out side applying one coat of zink primer for out side silencer pipe & providing self adjestive Asbasto Rope 12 mm dia from engine to exhaust pipe and painting with 2 coat of syenthetic enameled paint for expose portation of exhaust; all as directed.
M & L for scraping the peeled paint of DG set, preparing the surfaces, cleaning the dust and dirt etc of (alternator and engine) applying 2 coats of synthetic enamel paint over a coat of red oxide of approved shade and sign writing of SM / MES No on the set all as directed of capacity 75 KVA &82.5 KVA
Ditto as Srl Item No 68.00 above but for 15 KVA to 40 KVA DG Set.
M&L for in replacement solenoid Switch 12 Volt DC , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Stopping relay 24 volt DC , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Anti - Vibrating Pad suitable for 15 to 40 kVA DG Set , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Ignition Switch for capacity up to 75 KVA and 82.5 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L for Coolant as required for top up ,complete all as specified and as directed by Engr-in-charge.
M&L for Refilling of distilled water for top up battery 12 volt DC , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Fuel pipes with benjo bolt and washers For capacity 75 KV DG & 82.5 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Heavy duty Battery terminal for 12 volt DC battary Set of 2 , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Radiator Hose pipe as per existing , complete all as specified and as directed by Engr-in-charge.
M&L for inreplacmennt Door Lock Assembly with key for Acauastic DG SET , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Heavy duty Automatic electronic battery charger suitable for 12/24 Volt DC , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Solenoid coil for capacityy up to 75 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L for in replacement Rubber Coupling with nut bolt & washer in between Alternator & Engine up to 75 KVA & 82.5 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Air Filter inside & out side for capacity 15 kVA to 75 KVAR DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Primary Fuel Filter for capacity 75 KV DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Secondray Fuel Filter for capacity 15 KVA to 75 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Lubricating Oil Filter for capacity 75 KVA & 82.5 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement V- Belt as per existing size for capacity 15 KVA to 82.5 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Diesel pipe PVC Flexible up to 12 mm for capacity 15 KVA to 82.5 KVA DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Air Filter inside & out side for capacity up to 40 KV DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Primary Fuel Filter for capacity up to 40 KV DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Lubricating Oil Filter for capacity up to 40 KV DG SET , complete all as specified and as directed by Engr-in-charge.
M&L in replacement Fuel pipes with benjo bolt and washers. For capacity up to 40 KV DG Set , complete all as specified and as directed by Engr-in-charge.
M&L in replacment V- Belt as per existing size for capacity 15 to 40 KV DG SET , complete all as specified and as directed by Engr-in-charge.
M&L PVC / FRP chequered plates 10 mm and over cut to shape, square / notched ( ordinary and counter sunk , forming holes without any attachment in Quality 'A' , complete all as specified and as directed by Engr-in-charge.
M & L for testing of APFC panel for proper functioning in manual & auto mode,re-wiring the burnt out wires, and replacing the unserviceable spares and testing , complete all as specified and as directed by Engr-in-charge. NOTE :- Spares like power capacitors, load managers, push button, contactors, ammeter, voltmeter, MCBs will be measured and paid seperatly under respective item of sch'A'
M&L for replace to acoustic canopy of size appx 3 mtr X 1.2 Mtr X 1.5 mtr of 75 kVA & 82.5 KVA DG set incl painting matching with the existing color code and coushion pads , complete all as specified and as directed by Engr-in-charge.
Ditto as per Srl Item No 96 above but of size appx 2 mtr X 1.2 Mtr X 1.5 mtr of 15 kVA DG set incl painting matching with the existing color code and coushion pads , complete all as specified and as directed by Engr-in-charge.
M & L in replacement of Genset controller for 82.5 KVA , complete all as specified and as directed by Engr-in-charge.
M & L in replacement Voltage Monitoring Relay(VMR) as per site requirment , complete all as specified and as directed by Engr-in-charge.
M & L in replacement OEN Relay , complete all as specified and as directed by Engr-in-charge.
M & L in replacement Timer for controlling voltage shifting from no load to full load , complete all as specified and as directed by Engr-in-charge.
M & L in replacement water pump of capacity 75 KVA & 82.5 KVA for DG , complete all as specified and as directed by Engr-in-charge.
M & L in replacement water pump of capacity 40 KVA for DG set , complete all as specified and as directed by Engr-in-charge.
M & L in replacement Coolant Hose set for 75 KVA& 82.5 KVA , complete all as specified and as directed by Engr-in-charge.
M & L in replacement Coolant Hose set for 15 KVA- 40 KVA , complete all as specified and as directed by Engr-in-charge.
M&L Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm stranded for earth continuity wire, to be drawn in and including, instave enamelled Conduit conceased not less then 20 mm width, with metal sunken switch with face plate for switch complete with brass screws with cup washers including all necessary wall cutting and making good disturbed surface , complete all as specified and as directed by Engr-in-charge. Note : (1) Making good to match with the adjoining surface shall be included in the unit rate. (2) Rate is inclusive of Cutting/chases of wall/floor/ceiling. (a) One ceiling /exhaust fan point controlled by one switch and regulator
S&F FLP/WP switch /Isolator 10 Amp single pole ON/OFF , complete all as specified and as directed by Engr-in-charge.
S&F Flame proof weather proof exhaust fan 350mm single phase , complete all as specified and as directed by Engr-in-charge.
M/S KHUSHI ENTERPRISES
M/s Bhagirathi Electricals
DARSHAN CONSTRUCTION Co.
Atharva Enterprises
Vinod Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .