| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹5.7 L
EMD Value
₹5,664
Closing Date
25 Aug 2021, 3:00 pmClosed
Dy. Project Manager
Dy. Project Manager
Augmentation of LT power Cable between MSS and STP
2021_GGSIP_207103_1
11/SE/UWD/2021-22
Open Tender
Electrical Works
Works
30 days
Dy. Project Manager
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹5,664
2 Sept 2021
16 Aug 2021
25 Aug 2021
16 Aug 2021
25 Aug 2021
16 Aug 2021
Amount
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, & including interconnection with suitable size of copper conductor strip/cable in the existing panel making connections, etc. as required. 200 Amp, 36 KA, FPMCCB
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and suitable size copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3X150 sq. mm (50mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Making trench less under ground hole across the roads/cement concrete pathway at a depth of about 1 mtr. by means of manual augor and connecting pipes to suit the pipe/cable of size up to 100 mm dia. i/c making excavation on both side of road/pathway for making trenchless hole and refilling the same with excavated soil after laying pipe & cable through trenchless hole. watering. dressing complete as required as per instruction of Engineer-incharge. (Cost of laying of cable & pipe is not included in this item)
Supply of heavy duty 1100 V grade, XLPE insulated, PVC sheathed armoured cable with Aluminium conductor for the following size with ISI mark confirming to IS : 7098 part-1 amended up to date as required. 3x 150 sqmm Aluminium conductor cable
Supplying, installation, testing and commissioning of the following out door electrical panel/joint box of size not less than 600mm (H)x600mm (B)x400mm (D), duly floor mounted, weather proof IP-54 fabricated out of 2 mm thick CRCA sheet as detailed below in the suitable size to accommodate all the required mountings, with front & rear door openable & lockable arrangement with sloping roof, as per the approved drawing, the entire electrical panel/joint box should be mounted on 40 mm x 40mm x 6mm angle iron with minimum 600 mm long legs to be grouted in ground in suitable size CC foundation the electrical panel should be duly powder coated in required colour shade, earth studs etc., as required. Bus Bar :- Equally sized three phase and neutral copper conductor Bus Bar to carry 300 Amp, current and suitably insulated with colour coded Heat Shrink Sleeve
Supplying & installation of 4 pole 415 volt 200 amp On Load type change over switch in a suitable MS housing with suitable size cable end box at top and bottom duly powder coated. earthing and connection, testing etc.. as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .