GE(U) E/M Meerut Cantt
GE(U) E/M Meerut Cantt
REPAIR AND MAINTENANCE OF AC PLANTS OF 2 AHQ SIG UNIT AND 2 COY UB AREA SIGNAL CENTRE AND MISC WORK OF AGE E/M (WS) UNDER GE(U) E/M MEERUT CANTT.
2020_MES_381418_1
8292/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(U) E/M Meerut Cantt
₹30,000
Yes
2 Feb 2021
3 Oct 2020
10 Nov 2020
3 Oct 2020
3 Nov 2020
19 Oct 2020
3 Oct 2020 - 12 Oct 2020
60 days
Amount
S & F ( in repairs) Miniature circuit breakers FP, 32 Amps , 415 Volts ,50 hz, 10 KA, 'C' curve rating complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
Renewal of thermometers of suitable to measure water temperature complete all as specified.
Renewal of water pressure gauge with adapter, 100mm dia suitable to measure water pressure upto 10kg/sqcm complete all as specified.
Renewal of Oil pressure gauge with adapter, 100mm dia suitable to measure oil pressure upto 300 PSI complete all as specified.
Renewal / Topping of non freezing compressor oil N-46 in factory sealed containers in standard packings as directed.
Dismantling/ taking down burnt squirrel Cage Induction Motor of any capacity , 3 Phase, 415V, 1450 RPM of any make from its base and transporting the motor to the Contractor's workshop and back, refixing the motor at site after carrying out the following repairs/ renewals complete all as specified.- (i) opening the side covers and removing the rotor and cutting/ removing the burnt coils / winding from stator. (ii) Cleaning the slots carefully (iii) Rewinding the stator using super enamelled copper winding wire with same size, number of coils,number of turms/ coils as per data acquired from the old burnt motor, including varnishing two coats, drying and reassembling the electric motor at site (iv) Testing the coils for there continuity and no current passing through the stator core. (v) Dynamic testing of the rotor and alignment of the main shaft and ensure that no imbalance vibtrations. (vi) Re-assembling the rotor and connecting the end terminals to the terminal plate of the motor, closing the ends with side covers (vii) Testing and commissioing the electric motor connecting to the electric supply to its full load by connecting the compressor. (viii) Renewal of Bolts, nuts and washers Note :- Parts renewed i.e Ball bearing shall be measured and paid separately. However filling of grease and oiling extra shall be deemed to be included in Unit rates. Note:- The weight of copper coil provided before varnishing shall be taken for the purpose of payment.
Dismantling of side cover of Shell and tube type Condensor of Central AC plant, making arrangements to connect the suction and Discharge line to chemical pump, descaling the condensor by circulation of discalation solution and by rodding fitted with nylon brushes of suitable size and circulation of fresh water through condensor till clear water comes from other end including carrying out necessary repairs for 3x80 TR Capacity plant:- Note:- (i) Parts renewed only shall be measured and paid separately. (ii) The rate quoted againt this item shall include all the T&P and solutions required .
Dismantling of suction line from compressor of Central AC plant, making arrangements for connect the cooling coil , cleaning of cooling coil with carbon tetra chloride chemical solution for flushing out coil and dust for 3x80TR Capacity plant.
Renewal of low pressure gauge 300 PSI complete all as specified.
Renewal of High pressure gauge 500 PSI complete all as specified.
S&F (in repairs) thermostatic expansion valve suitable for 1x80 TR chilled water type AC plant including collecting the refrigerent in the empty cylinders arranged by Contractor at his own resources by any means , cutting, welding, brazing, renewal of gasket, nuts, bolts and washers etc. complete all as specified and directed.
Supply and charging of Refrigerent gas R-407 (c) Non CFC ( ecofriendly) in company sealed cylinders of any capacity complete all as specified. Note: If the recharged refrigerent gas is leaked within one month of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to department.
M&L for servicing of cooling tower (CT-68x68) of any make of 3x80 TR capacity Central AC by draining out complete water from bottom tank, cleaning of inner surfaces with nylone brushes opening of wtaer strainer from water inlet to condensor after removal of flange and renewal of gaskets and jali after cleaning and removal of all foreign materials and descaling of complete water pipe line with descaling solution complete all as specified.
Renewal of AHU V banks filter made of polyester with frame materials of ABS plastic of any colour and size, to remove most of the 0.5um particles with efficiency from 75-99% and micro and fine with frame , media support ,gasket face guard, separators etc. complete including cleaning of all types of AHU 'Y' strainers, isolation valves complete all as specified.
Renewal of Out door unit fan motor complete all as specified
Renewal of transformer with CT base unit suitable for Air cooled package type AC indoor unit of any capapcity complete all as specified.ed
Renewal of Fire dampers to match with the existing duly epoxy powder coated complete all as specified.
Taking down of existing unserviceable butterfly valve including rubber gasket, mild steel bolts, nuts, washers and S&F Cast Iron butterfly valve ISI-13095 marked, 150mm dia, class PN1 complete with neoprene rubber gaskets, mild steel bolts, nuts and washers etc. complete all as specified and directed of following bore and presssure rating. ( Mild steel nuts, bolts, washers, gaskets shall be deemed included in unit rate.)
Renewal of electronic mother board Model No. DPA2642R1 including 13 VAC, 220 Volt,AC coil, electronic cable arrangement of base unit suitable for Air Cooled packaged AC indoor unit 1x16.5 TR ( R-407 C non CFC refrigerent gas ( Model No. DPA-2642R2 ) complete all as specified.
S&F ( In repairs) including testing harmetically sealed scroll Compressor of 5.5 TR Air Cooled package type AC indoor unit of 2x16.5 TR capacities ( Model No. DPA-2642R2 of Blue Star) , suitable for 407(c) non CFC refrigerent gas including necessary brazing work to make the system leak proof complete all as specified and directed.
M&L for overhauling and servicing of existing control panel board consisting one incoming and 12 outgoing connections ( 3x100HP capacity of condensor motor , 800 Amps ACB, 3 nos 10 HP condensor pump set, 3 Nos 7.5 HP Chiller pump, 2 Nos 3 HP cooling tower motor) by disconnecting all control switches, capacitors, timers, phase preventors, relay coils, MCBs, MCCBs, wiring, ampere meter, voltmeter and other sensor, transporting to workshop , rewiring the panel Board with suitable size of copper wires/ cables , copper lugs, thimbles etc as per OE coding and reassembling the panel Board by replacement/ renewal of all articles/ accessories / equipments and testing for its fucntional requirement directed by ENgineer-in-Charge complete all as specified and directed. Note:- Items/ articles/ acceesories/ equipments etc. renewed shall be measured and paid at supply only rates as listed herebelow and rest of the items renewed shall be deemed included in the unit rates quoted by Contractor against this item.
Supply only manual fixed type , ACB, 3 pole, 800 Amps current rating,50 KA breaking capacity (Icu=Icw=Ics for one second) , 415V, 50 Hz,with thermal magnetic release , auciliary switch 1No,Main CTs, Shunt Trip complete all as specified.
Supply only MCCB for motor back up protection, 200 Amps, 415V, AC, 50 Hz, 3 pole and 50 KA complete all as specified.
Supply only MCCB for motor back up protection, 63 to 100 Amps, 415V, AC, 50 Hz, 3 pole and 50 KA complete all as specified.
Supply only power contactor suitable for induction motor , AC3 raing 550 Amps , 3 pole, 415 Volts, 50 Hz, 2NO+2NC auxiliary Contacts complete all as specified.
Supply only power contactor suitable for induction motor , AC3 raing 180 Amps , 3 pole, 415 Volts, 50 Hz, 2NO+2NC auxiliary Contacts complete all as specified.
Supply only power contactor suitable for induction motor , AC3 raing 160 Amps , 3 pole, 415 Volts, 50 Hz, 2NO+2NC auxiliary Contacts complete all as specified.
Supply only power contactor suitable for induction motor , AC3 raing 16 Amps , 3 pole, 415 Volts, 50 Hz, 1NO+1NC auxiliary Contacts complete all as specified.
Supply only Single phase preventor & dry run protection relay with VI meter ( Current based), 415 V complete all as specified.
Supply only electronic timers type ST 100, 3-30 sec, 415V, complete with mounting kit all as specified.
Supply only ammeter analog type, current rating 0 Amps to 50 Amps, suare type , flush mounted complete all as specified
S & F ( in repairs) 12.5mm dia ,24 gauge thick , copper tubing suiatnel for refrigerent gas circulating with necessary adaptor, bends, washers, connectors from compressor to LP/HP switches, condensor complete all as specified.
S & F ( in repairs) manual on load changover switch disconnectors, 800 Amps, AC 23A, 4 Pole ,415V, 50hs with handle assembly having door interlocking and pad locking aggarngement, in sheet steel enclosures complete all as specified.
Taking out defective compressor of 80 TR capacity make Kirloskar , Overhauling, testing, and commissioning of chiller type Central AC plant, (Make:-Kirloskar - model :- ......................) (Serial Machine No..........) including dismantling and disconnecting suction and discharge refrigerant lines, other controls and accessories, loading, transporting to contractors workshop and back to plant room after necessary repairing and then reinstallation in its original position ,nitrogen flushing and testing complete all as specified. (Note :-1. Renewal of items not covered in the succeeding items of BoQ but essentially required for completing the Job like cut washers, valve springs, castle nuts, etc shall be provided by the contractor and no extra payment shall be admissible on this account. (2).Parts renewed shall be measured and paid separately as supply only as given below.-
Supply only 'O' ring
Supply only Piston pin
Supply only Piston with rings
Supply only Piston liner
Supply only loader and unloader
Supply only oil pump for compressor
Supply only crank shaft
Supply only connecting rods
Supply only shaft seal
Supply only valve plate
Supply only Discharge reed
Supply only Main bearing
Supply only thurst Bearing
Supply only crank case heater
Supply only satety valve 400 PSI
Renewal of compressor sensor suitable for 80 TR complete all as specified and directed.
Jain Traders
M/S JPS Electrical Engineer & Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .