Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.0 L+₹34,400 (1.84%)Rejected-AOC | L2 | Rejected-AOC Second Lowest bidder | |
| 3 | Not Admitted-Fee | - | Not Admitted-Fee Fee not received |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
27 May 2021, 11:00 amClosed
Executive Engineer
Ex. En. ECDD Kavinagar Block-A Ghaziabad
6 Nos Duct A.C. with Installation and Air Ventilation Unit (3 Ton) and 6 Nos Split A.C. with Installation and Commission (2 Ton) at D.R. Center, Sec.58, Noida.
2021_PVVNL_585415_1
01/ECDD/GZB/2021-2022
Open Tender
Civil Works - Others
Item Wise
30 days
SECTOR-58 NOIDA
As per sheet attached
3 documents required · 3 mandatory
₹3,540
Ex. En. ECDD GZB
₹19,000
16 Jul 2021
6 May 2021
27 May 2021
6 May 2021
27 May 2021
6 May 2021
Supply, Installation and Testing with nitrogen pressure testing Vacuumization and Gas opening & Commissioning of Hitachi or equivalent Ductable Air Conditioning units 3.0 TR as per E/I. NSI
Supply, Installation and Testing with nitrogen pressure testing Vacuumization and Gas opening & Commissioning of Hitachi or equivalent make 2.0 Ton Split A.C. including labour and T&P required for proper completion of work. NSI
supply and Installation of Split Units outdoor Stand including labour and T&P required for proper completion of work. NSI
Supply and Installation of ductable Units outdoor Stand including labour and T&P required for proper completion of work. NSI
supply/Installation and Testing of soft drawn seamless copper refrigerant piping for ductable A.C. units including copper fitting, elbows, joints & Clamping & Supports at place of piping. The pipe shall be insulated with 9 mm thick nitrile rubber insulation sleeves. The size of refrigerant piping shall be Hitachi or equivalent including labour and T&P required for proper completion of work. NSI
supply/Installation and Testing of soft drawn seamless copper refrigerant piping for Split A.C. units including copper fitting, elbows, joints & Clamping & Supports at place of piping. The pipe shall be insulated with 9 mm thick rubber insulation sleeves. The size of refrigerant piping shall be Hitachi or equivalent including labour and T&P required for proper completion of work. NSI
Supply & Fixing of 32mm Rigid uPVC Piping for ductable/split A.C. Units complete with u Trap. Fittings, Supports as per specifications and dully insulated with 6 mm thick closed cell rubber insulation / Closed cell cross linked polyethylene insulation. NSI
Supply and wiring of submain with two number 6 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia PVC heavy conduit on surface, with one number 4Sqmm copper earth continuity wire etc., complete in all respect. UPPWD 212(C)
Providing A.C. Box with MCB, Anchor / Havells or equivalent make as per direction of E/I. CSI No. 26.173
Supply Fabrication & erection of Rectangular Ducting with insulation - Fabricate Sheet Metal GSS ducts / Sq.mt. with MS Flanges / 22/24 guage sheet mantling hanging with Nut Bolt Tie Road MS-Angle GI Nut Bolt Canwas Connection, six machine 3 Ton necessery fitting as per site requirement or as per direction of E/I. NSI
Supply Installation/Testing and commissioning flexible conection (Durodyne type) to connect fan outlet with Duct. necessery fitting as per site requirement or as per direction of E/I. NSI
Supply Installation and commissioning air alumenuam grills for air distribution with all necessery fitting as per site requirement or as per direction of E/I or Standard supply air Grills with colour diffusers. NSI
Supply Installation and commissioning air return work alumenuam grills for air distribution with all necessery fitting as per site requirement or as per direction of E/I or Standard supply air Grills with colour diffusers. NSI
Supply Installation and commissioning air Rectangular Diffusers for air Supply (Alumenuam as per direction of E/I) NSI
Removing/ Dismantling of old A.C. with outdoor unit and stacking them within 60 meter distance as per direction of E/I. including labour and T&P required for proper completion of work. NSI
Providing Voltage Stabliser for 110 - 280 V rating of approved brand (6KVA) as per Approved by E/I. NSI
Dismantling/ Removing old false ceiling and old unserviceable duct and repairing/ renovate the same after installation of new complete ducting work including labour and T&P required for proper completion of work but excluding cost of duct. old scrap shall be property of contractor. wastage/scrap shall be diffuse by the contactor area of room shall be measure. NSI
AVIATION ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .