Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹7.1 L+₹42,122.40 (6.34%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹7.6 L+₹98,310.40 (14.8%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE |
Tender Value
₹6.2 L
EMD Value
₹12,400
Closing Date
12 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Tapan Das, AE (Civ)
AGE (I) AF Singarsi
Works services for shifting of equipment Room- II to Building No 211 S/BY OPS Room AF Stn Singarsi
2023_MES_628204_1
C/8626/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) AF Singarsi
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
AGE I AF Singarsi
₹12,400
Yes
1 Feb 2024
14 Nov 2023
14 Dec 2023
14 Nov 2023
12 Dec 2023
28 Nov 2023
Amount
Dismantling of floor, hearth or wall tiling/pavin blocks including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc, complete all as specified and as directed.
Demolition of cement concrete (un reinforced ) in ground floors and pavings n. exc 15cm thickness (below or above ground level),complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5m in depth and getting out, complete all as specified and as directed.
Supply and laying new dry river sand laid in trenches 8 cm below the cable and 15cm above the cable and punned to 18 cm as cable cushioning and covering,complete all as specified and as directed.
Supply and laying in replacement of brick well burnt locally available sub class 'B' laid over sand cushioning for cable protection in trenches width of brick perpendicullar to the length of cable including taking up of old UNSV bricks complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25 cm depth,complete all as specified and as directed.
Removing of excavated material (soil) to a distance n.exc 50 meter and depositing where directed at a level n.exc 1.5 meter above the starting point,complete all as specified and as directed.
M&L for brick work with fly ash straight or curved on plan exc 6mm mean redius built in cement mortar (1:6),complete all as specified and as directed.
M&L for rendering 15mm thick other than fair faces of brick work or concrete surfaces in cement mortal (1:6) for internal brick, complete all as specified and as directed.
M&L for P.C.C type B-1, 1:2:4 (40mm graded aggregate) 75mm thick in cable duct flooring and finishing cement concrete surface even and smooth withour using extra cement,complete all as specified and as directed.
M&L for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, and made sliding, bolts, clamps, hold fasts, wall tiles, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde E-165,complete all as specified and as directed.
M&L for framed work for flat plate in electric cble duct, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors; framework of similar work conforming to Fe.290.Gde-E-165 including all necessary welding work etc, complete all as specified and directed by Engineer-In-Charge.
S&F chequered plates (plain or chequered) channels, rectangular cut or notched (ordianary and counter sunk) forming holes, with riveted, bolted or welded attachment, complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.5 cum getting out returing filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm in soft/loose soil,complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded aggregates) in foundation filling and mass concrete as in lean concrete,complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded aggregates) in foundation filling for steel post and mass concrete as in lean concrete,complete all as specified and as directed.
M&L for roof trusses (framed), trussed, purlins, water staging, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including pieces, cleats etc. Including necessary welding, fabrication Fe-410W (Gde E-250) quality B,complete all as specified and as directed.
M&L for Joint, channel, angle, or tee section, fixed independently, without connecting plates, etc for post (cut to ordinary length i.e within 20mm of the length indicted) conforming Fe-410W (GdeE-250) quality B,complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
M&L for cutting chasesin platered brick masonry wall, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good cutting not exc 10 cm girth etc,complete all as specified and as directed.
M&L for preparation of new steel surfaces of any desctiption over 10cm in width or girth not otherwise described and apply two coats of synthetic enamel paints over a coat of red oxide zinc chrome primer,complete all as specified and as directed.
S&F VTPN DB 4way 415V,50Hz double/single door door,IP 43 protection with 200 amps rated bus bar for provision MCCB 4P as incommer and MCBs for outgoing circuits complete,fill empty with blanks, making good the surface area, complete all as specified and as directed.
S&F MCCB 100 Amps, 3 pole 415V, 50Hz, 16KA of capacity for fixing in VTPN DB's 4 way, complete all as specified and as directed.(DB for ACs)
S&F MCCB 63 Amps, 3 pole 415V, 50Hz, 16KA of capacity for fixing in VTPN DB's 4 way, complete all as specified and as directed .
S&F MCB TPN 63 Amps, 240V, 50Hz, 10KA of capacity, complete all as specified and as directed.(02 NosFor Acs, 01 Spare)
S&F MCB TPN 32 Amps, 240V, 50Hz, 10KA of capacity, complete all as specified and as directed
S&F MCB DB double door,IP 43 protection single pole and neutral 12 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 V natural link, complete all as specifiedand as directed.
S&F MCB DB double door,IP 43 protection single pole and neutral 8 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 V natural link, complete all as specifiedand as directed
S&F MCB SPN upto 40 Amps, 240V, 50Hz, 10KA of capacity, complete all as specified and as directed
S&F MCB SP 6 to 40 Amps, 240V, 50Hz, 10KA of capacity, complete all as specifiedand as directed
S&F triple pole and neutral enclosure with a five pin earth plug and socket complete with one single pole MCB of 32A TPN, C-Curve, 50Hz, 415 volts, compete all as specified and as directed.
S&F for switch socket combination 5/16 Amps 5/1 pin 240 volts, complete with box as specifed and as directed
M&L for Submain wiring with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid casing and caping of suitable size with accessories fixed to wall complete and making good the disturbed area for 5 runs 10.0 Sqmm (03 No phase conductor, 01 no netral conductor, 01 earth continuity wite), complete all as specified and as directed. ( Note:- 5 runs of 10.0 Sqmm and one run of casing caping shall be measured and paid as one length.
M&L for Submain wiring with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit of suitable size with accessories fixed to wall complete and making good the disturbed area for 5 runs 6.0 Sqmm (03 No phase conductor, 01 no netral conductor, 01 earth continuity wite). complete all as specified and as directed.( Note:- 5 runs of 6.0 Sqmm and one run of casing caping shall be measured and paid as one length.
M&L for Submain wiring with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit of suitable size with accessories fixed to wall complete and making good the disturbed area for 3 runs 2.5 Sqmm (01 No phase conductor, 01 no netral conductor, 01 earth continuity wite, complete all as specified and as directed.( Note:- 3 runs of 2.5 Sqmm and one run of casing caping shall be measured and paid as one length.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip of size 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and as directed.
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 400 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Neart OPS Complex). Incoming: (a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 200 A capactiy 35kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01No. Outgoing: (a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 63 A capactiy 35kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 6 No.( 04 VTPN DBs & 02 Spare). b) Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers. c) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases for each breakers. complete all as specified and as directed by eng-in-charge. Make as per CPRI approved.
Supply,lay,connect and commission LT underground cable XLPE of size 25 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc,complete all as specified and as directed.
Supply,lay,connect and commission LT underground cable XLPE of size 70 sqmm 3.5 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc,complete all as specified and as directed.
Taking down DB (including MCB/MCCB), Metal plug and box, switch socket care fully and refixing at new location, complete all as specified and asd directed. Note: Rate for material used for refixing of DBs, metal plug and switch socket should be included in the quioted rate.
M/S SINGH ENTERPRISE
LALAN SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .