Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | ₹46.8 L Quoted ₹47.5 L | L1 | Accepted-AOC AOC |
| 2 | L2₹50.2 L+₹2.7 L (5.74%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹50.2 L+₹2.7 L (5.74%) | L2 | Rejected-Finance Other Than Being Lowest |
| 3 | L3₹54.6 L+₹7.1 L (15.0%)Rejected-Finance | ₹54.6 L+₹7.1 L (15.0%) | L3 | Rejected-Finance Other Than Being Lowest |
| 4 | L4₹63.2 L+₹15.7 L (33.0%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | ₹63.2 L+₹15.7 L (33.0%) | L4 | Rejected-Finance Other Than Being Lowest |
| 5 | L5₹70.3 L+₹22.8 L (48.0%)Rejected-Finance | ₹70.3 L+₹22.8 L (48.0%) | L5 | Rejected-Finance Other Than Being Lowest |
| Sl No | Description | Qty | Unit | Chakshu Enterprise L4 | AGRAWAL ASSOCIATES L2 | Hardik Engineers L3 | Shetty Construction Co L5 | ASHOK ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | SCH 'A' PART- I
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/ parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at GANGOTRI BHAGIRATHI Building (G+15) comprising following:-
(a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.
(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.
(c) All wiring & cable connections
(d) Lead acid battery 12V/9AH Capacity.
(e) 60 HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.).
(f) Testing of Electrical control panel of Fire Fighting System Water Pumps.
(g) Testing of Pressure switch & Pressure Guage.
(h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M. | 11 | Per Month | 4,000 ₹44,000 | 3,500 ₹38,500 Lowest | 6,000 ₹66,000 | 4,990 ₹54,890 | 4,000 ₹44,000 |
| 2.00 | Ditto all as per item Ser No 1.00 but for building ADITI AHILYA Building (G+12) | 11 | Per Month | 4,000 ₹44,000 | 3,500 ₹38,500 Lowest | 6,000 ₹66,000 | 5,800 ₹63,800 | 4,000 ₹44,000 |
| 3.00 | Ditto all as per item Ser No 1.00 but for building SASSON COMPLEX – Four Building(Akash, Chandra, Badal & Diwakar) (G+12) | 11 | Per Month | 5,000 ₹55,000 | 3,500 ₹38,500 Lowest | 15,000 ₹1,65,000 | 7,700 ₹84,700 | 4,000 ₹44,000 |
| 4.00 | Ditto all as per item Ser No 1.00 but for building BOAT POOL WORKSHOP Building (G+1) AND NT POOL | 11 | Per Month | 4,000 ₹44,000 | 3,500 ₹38,500 | 5,000 ₹55,000 | 4,900 ₹53,900 | 3,000 ₹33,000 Lowest |
| 5.00 | Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/ parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at VATSALA Building (G+12) comprising following:-
(a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.
(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.
(c) All wiring & cable connections.
(d) Lead acid battery 12V/9AH Capacity.
(e) 60HP Main Fire Hydrant Pump Servicing & Testing (02Nos.).
(f) 10HP Jockey Pump Servicing & Testing (02 No.).
(g) Testing of Electrical control panel of Fire Fighting System Water Pumps.
(h) Testing of Pressure switch & Pressure Guage.
(i) Testing of all Sluice Valve, NRV & Air Release Valve.
(j) testing of 60 HP DG fire hydrent pump - 01 No | 11 | Per Month | 4,000 ₹44,000 | 3,500 ₹38,500 | 7,000 ₹77,000 | 4,900 ₹53,900 | 3,000 ₹33,000 Lowest |
| 6.00 | Ditto all as per item Ser No 1.00 but for building INS SHIKRA (ATC TOWER) Building (G+7), All Hangers and INS SHIKRA (Adm ) Building (G+7) / (New sailors Accn ) Building (G+7) and DSC bldg . | 11 | Per Month | 5,000 ₹55,000 | 3,500 ₹38,500 Lowest | 15,000 ₹1,65,000 | 7,700 ₹84,700 | 7,000 ₹77,000 |
| 7.00 | Supply and fixing in repair transformer AC/DC for fire alarm system panel of electronic type | 15 | Each | 800 ₹12,000 | 200 ₹3,000 Lowest | 250 ₹3,750 | 1,100 ₹16,500 | 500 ₹7,500 |
| 8.00 | Supply and fixing in repair battery duly charged 12 V, 7.2 AH for fire fighting alarm panel complete all as specified and directed. | 40 | Each | 1,500 ₹60,000 | 800 ₹32,000 Lowest | 1,050 ₹42,000 | 1,600 ₹64,000 | 1,400 ₹56,000 |
| 9.00 | Supply and fixing in repair Zone cards complete all as specifed and directed. | 3 | Each | 25,000 ₹75,000 | 150 ₹450 Lowest | 250 ₹750 | 2,200 ₹6,600 | 500 ₹1,500 |
| 10.00 | Supply and fixing in repair power cards asper existing addressable fire panel complete all as specifed and directed. | 3 | Each | 16,500 ₹49,500 | 150 ₹450 Lowest | 250 ₹750 | 13,000 ₹39,000 | 500 ₹1,500 |
Tender Value
₹78.7 L
EMD Value
₹1.4 L
Closing Date
27 Dec 2025, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
REPAIR ROUTINE MAINTENANCE OF FIRE FIGHTING SYSTEM AND FIRE ALARM SYSTEM AT MARRIED AND OTM ACCN AT OUTLYING AREA UNDER GE(NW) NOFRA,COLABA MUMBAI
2025_MES_741558_1
8668/CWE(NW)Mumbai/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) NOFRA
Class C
Category c(vi)
7 documents required · 7 mandatory
₹1,000
GE (NW) NOFRA
₹1.4 L
Yes
29 Jan 2026
1 Dec 2025
29 Dec 2025
1 Dec 2025
27 Dec 2025
22 Dec 2025
1 Dec 2025 - 19 Dec 2025
Amount
SCH 'A' PART- I Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/ parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at GANGOTRI BHAGIRATHI Building (G+15) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) 60 HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (g) Testing of Pressure switch & Pressure Guage. (h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M.
Ditto all as per item Ser No 1.00 but for building ADITI AHILYA Building (G+12)
Ditto all as per item Ser No 1.00 but for building SASSON COMPLEX – Four Building(Akash, Chandra, Badal & Diwakar) (G+12)
Ditto all as per item Ser No 1.00 but for building BOAT POOL WORKSHOP Building (G+1) AND NT POOL
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/ parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at VATSALA Building (G+12) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections. (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02Nos.). (f) 10HP Jockey Pump Servicing & Testing (02 No.). (g) Testing of Electrical control panel of Fire Fighting System Water Pumps. (h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve. (j) testing of 60 HP DG fire hydrent pump - 01 No
Ditto all as per item Ser No 1.00 but for building INS SHIKRA (ATC TOWER) Building (G+7), All Hangers and INS SHIKRA (Adm ) Building (G+7) / (New sailors Accn ) Building (G+7) and DSC bldg .
Supply and fixing in repair transformer AC/DC for fire alarm system panel of electronic type
Supply and fixing in repair battery duly charged 12 V, 7.2 AH for fire fighting alarm panel complete all as specified and directed.
Supply and fixing in repair Zone cards complete all as specifed and directed.
Supply and fixing in repair power cards asper existing addressable fire panel complete all as specifed and directed.
Supply and fixing in repair power cards asper existing conventional fire panel complete all as specifed and directed.
Supply and fixing in repair manual call point suitable for addressable system duly painted in red colour paint with front glass (to be broken in case of fire ) complete with test key to check the response with out breaking the glass and die cast aluminum housing with IFD indicator all as specified.
Supply and fixing in repair manual call point suitable for conventional system duly painted in red colour paint with front glass (to be broken in case of fire ) complete with test key to check the response with out breaking the glass and die cast aluminum housing with IFD indicator all as specified.
Supply and fixing in repair electronic hooters complete all as specifed and directed.
Supply and fixing in repair Addressable type Smoke / Heat detector complete all specifed and directed.
Supply and fixing in repair Addressable type Smoke / Heat detector suitable for conventional type fire panel asper existing complete all as specifed and directed.
Supply and fixing in repair hydrant valve wheel complete incl all necessary fixtures and fittings as reqd.
Supply and fixing in repair hydrant gun metal female coupling brass complete all as specifed and directed.
Supply and fixing in repair hydrant gun metal female coupling SS complete all as specifed and directed.
Supply and fixing in repair rubber hose drum adopter connection (shank reducer) at site complete all as specified and directed
Supply and fixing in repair brass lock pin (lugs) for 63 mm dia at site complete all as specifed and directed.
Supply and fixing in repair hydrant valve spindle at site complete all as specifed and directed.
Supply and fixing rubber hose pipe 20mm dia, plain 2 ply rayon braided high pressure complete all as specifed and directed.
Supply only Aluminium/ brass nozzle suitable for 20 mm dia rubber hose pipe complete all as specifed and directed.
Supply and fixing in repair 100 mm sluice valve wheel complete all as specifed and directed.
Supply and fixing in repair brass hydrant valve nut as per existing size complete all as specifed and directed.
Supply and fixing in repair blank flange of size 80/100mm made out of MS 12 mm thick including flange joint complete all as specifed and directed.
Supply and fixing in repair PVC blank cap of hydrants with GI chain complete all as specifed
Supply & fixing hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard & fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle including taking down old cabinet complete all as specifed and directed.
Supply and fixing in repair canvas fire hose 63mm dia bore 30 metre long confirming to IS Having male/female brass coupling both end complete all as specified.
Supply only SS Nozzle 25 mm bore suitable for 63mm dia canvas pipe complete all as specified.
Excavation in trenches n.ex.c 1.5 meter wide and n.exc 1.5 meter in depth for foundation etc for shafts, wells, cesspits,manholes,pier holes, etc n.exc 1.5min depth and getting out in hard/dense soil.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Returning, filling is including spreading, leveling, watering and well ramming in layers n.exc. 25cms(Soil).
Cutting out concrete blocks, slabs, brickwork or stone masonry(in alternate course) forming toothings for and bonding new work in mortar into old work, including new materials entering old wall complete all as specifed and directed.
Taking down existing double acting valve of size 100 x 65mm for servicing including replacement of unserviceable spares ie gland, nut, bolt, lock pin, CI hand wheel with chain, etc complete and re-fixing in position in high rise bldg not exceeding 15 stories complete all as specifed and directed.
Supply & fixing in repair Gun metal double acting fire hydrant valve of size 100 x 65mm conforming to IS – 5290/71 with all fitments such as cap cover instantaneous coupler for making flanged joint 100mm dia bore including taking dwon oldcomplete all as specifed and directed.
Repairing to MS front door of size not exceeding 1.5 mtr x 1.5mtr including welding locking arrangement and painting complete with red colour including providing pad lock 50mm complete all as specifed and directed.
Preparing old painted surface of CI/MS pipe 100mm/150mm dia and applying two coats of synthetic enamel complete all as specifed and directed.
Servicing of hose reel drums by applying greasing, oiling etc and making free rotation to hose drum complete all as specifed and directed.
Removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces of any description over applying two coats of synthetic enameled paint over a coat of red oxide primer on fire pump fire valve pit / fire fighting cubical box fitted inside bldg on each floor.
Supply and replacement, installation, testing & commissioning of Micro processor based 2 wire fault tolerant loop, required loop networkable type 5 Loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/ detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output. The Panel shall support 24 zones Addressable 2 way Talk Back fire fighter communication, in case of emergency. The panel shall have ability to get integrated with PA System for zone wise annoucements. The panel shall support both Loop Powered & conventional Notification devices for emergency responses. the Panel shall support Auto learn feature. The panel should support networking upto 99 panels with maximum distance of 12 Km between 1 & last & 1.5 KM between adjacent panels on RS485. Tha Panel shall support IP connectivity if requred to connect on LAN or WAN network. the panel shall support BMS connectivity through Bacnet/Modbus moduels. The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have 24 Zones with Individual LED Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/ LPCB/ VDS/ UL/BSA including taking down old panel complete all as specified and directed by Engineer-in-Charge, Voice Alarm controller with USB, MP3, AM/FM player )with 1000 watts Power Amplifier.
Supply and laying MS pipes 100mm dia conforming to IS 1239 (Part-I) medium grade with both ends flanged and drilled with standard MS fitting including 02 coats of synthetic enamel painting over one coat of red oxide primer in any length and fixed on walls including taking down old pipe complete all as specified and directed in high rise buildings. Note : MS flanges including welding to MS pipes and all flanged joints shall be measured and paid separately under respective item of Sch ‘A’
Supply and laying MS tubing 150 mm dia medium grade with all fitting such as tee, socket, bend, union etc in trenches including taking down pipe complete all as specified and directed
Supply & Fixing MS flanges duly drilled including welding to 100/150 mm dia MS pipes complete all as specified and directed.
Material & Labour for flanged joints for 100mm/150 mm bore pipe at any location and position complete all as specified and directed .
Supply and fixing in repair Gun metal fire hydrant single acting of size 80 x 63mm for stand post.
Supply & Fixing in repairs sluice valve, 100 mm size, both ends flayed with high tensile brass spindle,cast iron body, as per IS-14826 & ISI Marked,PN-1.6 pressure rating including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified,
Supply & Fixing in repairs Non return valve ball type, confirming to IS, Model B-05, of size 100 mm complete all as specifed and directed..
Material & labour for Rewinding of electrical induction motor upto to 15HP capacity 3 phase 415 V of terrace booster pump of high rise bldg, including rewinding of the motor by proper gauge of copper wire with class E insulation with varnishing, heating and re-assembling and testing at the site.
Material & labour for Rewinding of electrical induction motor up to 40/ 75HP capacity 3 phase 415 V of terrace booster pump of high rise bldg, including rewinding of the motor by proper gauge of copper wire with class E insulation with varnishing, heating and re-assembling and testing at the site.
Material & labour in Repair of 40/ 75HP pump and disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out the pump set of any make from pump houses after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gasket, assembling the pump with replacement of pulley, gland packing, greasing, transporting back to pump house and refixing on the existing foundation, connecting the electrilc connection to the motror and testing complete to entire satisfaction of Engineer-in-Charge .
Material & labour Repair/maintenance of booster pump capacity upto 15 HP including necessary replacement of shaft impeller, bearings gun metal bush and coupling etc complete all as specified and directed.
Supply and fixing in repair of electrical motors star delta starter fully automatic of capacity upto 05 HP complete all as specified and directed.
Supply and fixing in repair of electrical motors star delta starter suitable for 60 HP motor fixed in panel including timer , relay and electric cable 35 Sqmm single core for connection complete all as specified and directed. .
Supply and fixing in repair of star delta starter contactor of capacity MNX 80 suitable for 40/60 HP motor complete all as specifed and directed.
Taking down old unserviceable motor starter . Supply and fixing in Replacement of electrical motors star delta starter fully automatic with inclosure and on off button of capacity 60/ 100 HP motor complete all as specifed and directed.
Supply and fixing in repairs FOOT valve (ISI marked), 150 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. complete all as specified and directed by Engr in Charge.
Supply and fixing in repairs FOOT valve (ISI marked), 100 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. complete all as specified.
Supply and fixing cable of 1.5 Sqmm x 4 Core Copper armoured Cable including taking down old cable complete all as specified and directed..
Supply and fixing of cable of 1.5 Sqmm x 2 Core Copper armoured Cable including taking down old cable complete all as specified and directed.
Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump of cap 01 lakh to 02 lakh ltrs after draining out scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface complete all as specified and directed.
Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump of cap 35000 ltrs after draining out scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface complete all as specified and directed.
Material & labour for PCC 1:3:6 type C2 (using 20 mm graded crushed stone aggregate) for plinth protection of semi under tank and PCC on fire water tank , road cutting area complete all as specified and directed.
Repair of broken valve pit chamber using sub class "B" brick masonry in cement mortar 1:4 including plastering internally and painted flush externally as the work proceeds and PCC 1:2:4 type B-1 as in copping and welding work with angle iron frame 40 mm x 40 mm x 6 mm with 4 mm thick MS sheet cover two side open with 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil all as specified and directed.
Repair to unserviceable sluice valve of size 150/100 mm dia. Opening the nut,bolts both side flanged ,after taking down unscrew the top cover and taking out the spendle , gate with chucknut. Repair the unserviceable spindle and re-threading, spndle ,and refix the new checkunt as per spindle size. After repairing the sluice valve which shall be refixed to its position and testing all as directed by EIC
Disconnect electric connection and taking out existing service cable from the cable duct and cleaning sand /mud /other items after cleaning reconnect the service cable in fire pump house and checking electric supply in fire pump house as per directed by Engr - in -charge
Supply & fixing in repair new non return valve (ISI marked) of CI body 150 mm bore flanged with rubber packing including nuts bolts and wahsers etc complete as directed by EIC
Taking down the broken iron coupling from the 40 HP to 60HP motor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts.
Supply and fix in replacement single core copper conductor cable PVC insulated of size 35 sqmm , 1100 volt conforming to IS 694/1990 and privide PVC pipe for protection of cable
Supply and fix in replacement tyco fire sprinkler fixing in ceiling mounted as per sample and directed by Engr-in-charge
Taking down old unserviceable pressure gauge with the help of gas cutter and S& F in replacement new Pressure gauge 100/150 mm mm dia with ball valve of pressure 25 Kg/Sqcm directed by Engr-in-Charge.
Taking down old unserviceable air release valve (ISI marked) from the pump and supply and fixing brass air release valve as per sample as directed by Engr-in-Charge.
Supply installation, testing & commissioning of 2 to 5 zone conventional type fire alarm panel system with LCD/LED chracter display each zone compatable with 20 devices (MCP/Hooter/detector) 240 V AC power supply automatic battery charger 24 volts sealed lead acid batteries sufficent for 24 hrs during emergency conditions as required.
M&L for attending underground pipe line leakage complaints of pipe of dia 80 mm to 200 mm upto 2 mtr depth line in any type of soil/ hard standing/ under road including earth work by/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate.
Material and labour to carry out the servicing of the diesel Engine pump set 60/100 HP with repair and replacement of worn out/ defective spare parts including preventive maintenance and servicing of radiator and connected assemblies:- (a) Replacement of fuel filter (b) Replacement of oil filer (c) Replacement of air filter (e) Replacement of Engine oil (f) complete overhauling of Engine (g) Replacement of "O" type ring and nut bolts as required.
M&L for attending underground pipe line leakage complaints of pipe of dia 80 mm to 200 mm in open shaft/ open space of high rising bldg height up to G+15 by welding or joint work, labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate complete all as specified and directed.
M&L MS plate thickness as sper site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed
Material and labour for Angle Iron of size as per site requirement and square bar applying two coats of synthetic enamel paint over a coat of red oxide primer and complete all as specified and directed
AGRAWAL ASSOCIATES (BID ID -3509500)
Hardik Engineers (BID ID -3509557)
Chakshu Enterprise (BID ID -3509236)
Shetty Construction Co (BID ID -3509714)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8668.rar
Tender Documents • 2.58 MB
BOQ_830374.xls
BOQ • 3.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .