| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹19.1 L+₹34,387 (1.84%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹19.8 L+₹1.1 L (5.94%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹22.4 L+₹3.7 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹22.6 L+₹3.8 L (20.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
9 Jun 2020, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda, Bathinda Military Station
SPECIAL REPAIRS TO OR MD ACCN BLDG NO P- 68/1 to 12 (TOTAL 12 QTRS) IN GOVIND ENCLAVE UNDER GE (SOUTH) BATHINDA AT BATHINDA MIL STN
2020_MES_337293_1
CA NO CWE BTD 11 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
Bathinda Mil Station
As per NIT
7 documents required · 7 mandatory
₹500
GE South Bathinda
₹55,000
Yes
7 Jul 2020
3 Apr 2020
11 Jun 2020
3 Apr 2020
9 Jun 2020
5 May 2020
3 Apr 2020 - 10 Apr 2020
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each and removing from site including cutting holes for removal of hold fast complete.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified in Preamble 8B.3.1 of SSR Part -II (2010) and all as shown on drawing of SSR Part-II (2010).
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement all as per instruction and drawing shown for item No 8080 of SSR Part II.
S & F PTMT butt hinges 100mm long.
S & F 150 mm long PTMT barrel tower bolt.
S & F 100 mm long aluminium anodised, barrel tower bolts of extruded section.
S & F 100mm extruded aluminium alloy handles, cast type, anodised.
S & F 125mm extruded aluminium alloy handles, cast type, anodised.
S & F 125mm long best quality PTMT handles.
S&F 75mm long size Hasp and staple, safety type, aluminium anodised with hinge pin including bolt to hinge plate and fixed with screws.
S&F 100mm size Hasp and staple, safety type, aluminium anodised with hinge pin including bolt to hinge plate and fixed with screws.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each and removing from site including cutting holes for removal of hold fast complete.
S&F factory made pressed steel frames for door with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc, compete, all as specified of frame size 105 mm x 60mm & thickness of MS sheet shall not be less than 1.25 mm including making holes for fixing hold fast etc and making good the wall with plaster in cement mortar (1:6) complete.
S&F factory made pressed steel frames for door with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc, complete, all as specified of frame size 125 mm x 60mm & thickness of MS sheet shall not be less than 1.25 mm including making holes for fixing hold fast etc and making good the wall with plaster in cement mortar (1:6) complete.
S&F factory made pressed steel frames for cupboard frames with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc, complete, all as specified of frame size 75 mm x 60mm & thickness of MS sheet shall not be less than 1.25 mm including making holes for fixing hold fast etc and making good the wall with plaster in cement mortar (1:6) complete.
M & L for PCC (1:3:6) type C-0 using 12.5 mm graded stone aggregate in filling in chowkats/ door frame or bed block of hold fast and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete.
Taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm each and removal from site.
Taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm each and refixing in the same opening including easing and adjusting and including renewal of unserviceable screws etc complete.
S&F 35mm thick factory made panelled shutter (two panel) plain framed with lock rail and panel of 12mm thick veneered particle board with commercial veneering on both faces conforming to IS-3097 exterior grade kiln seasoned and chemically pressure treated of second class hard wood rails and styles and the size of rail and style as per IS-1003 (Part I).
S&F factory made glazed and skeleton shutters 35mm thick using second class hard wood open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc; sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24(a); all as specified complete.
M & L for factory made flush shutter 25mm thick solid core construction with block board core and plywood face panels commercial type on both sides complete.
S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt, length of bolt 200mm.
S & F 125 mm mild steel pressed handles, oval type, stove enamelled black.
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt 250mm.
S & F 300 mm long MS ordinary rat tail rod pattern springs for doors including roller and roller plate complete.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples complete.
S&F in repairs, stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples complete.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat painting including dismantling of old existing window as directed.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat painting including dismantling of old existing window as directed.
S&F factory made fixed type steel ventilator with glazing bar complete including dismantling of old existing window/ ventilator as directed.
M & L for prelaminated particle board, 18/19 mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, ISI marked, fixed with screws to timber frame work complete including dismantling boarding of any type and description fixed in any position with rails including fillets complete.
M & L for second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn of cross sectional area exceeding 3 Sqcm and not exceeding 6 Sqcm secured with nails or beads complete.
S&F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised of 30 mm width of flap (when open).
S & F MS framed work such as grills, gratings, guard bars etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290 Gde E-165.
Welding in repairs, not exc. 6mm thick metal and not exc 2.50cm in length complete.
Cutting holes in exceeding half brick but not exceeding one brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B1 as required at site all as directed.
M & L for MS framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc, not exceeding 10 Kg each brackets, conforming to Fe 290 Gde E-165.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins / spring clips size not exceeding 0.5 Sqm each pane complete.
S & F sheet glass, 4 mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane fixed with oil putty or wooden beads including Provn of glazing pins/spring clips wherever necessary complete.
S & F 4 mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete.
M & L for painting to new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces.
M & L for painting to new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces.
S&F in repairs 25mm dia drapery rod, mild steel, chromium plated with fixing brackets, stops, rollers etc as in curtain rails. (Note : The cost of brackets and knobs is deemed to be including in the quoted unit rate. Nothing extra shall be paid on this account.)
M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing material as in benching, kerbs, mud stops, along side walls adjoining to roofs and similar items complete. (Water proofing material shall be measured and paid for separately).
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar (1:3).
Supply only liquid water proofing material, ISI marked.
M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregate in coping, window cills, steps, bed blocks, roof kerbs or mud stops, rounded or chamfered on edges complete.
M&L for PCC (1:5:10) type E2 using 40 mm graded stone aggregate as in filling of sunken floor including demolition of existing PCC.
M&L for sunken treatment to sunken floor, cleaning the surface by using wire brush, rendering to floor and sides with 10 mm thick cement mortar (1:3) including mixing of liquid water proofing material @ 200ml per bag of cement, finished even and smooth without using extra cement after that material & labour for providing two coats of two components (one part liquid two parts powder) ready to use cementations water proofing coating on properly prepared surfaces by brushing having elongation of >50% for the applying water proofing treatment as per following on horizontal and vertical surfaces of sunken floor complete all as per manufacturers instruction. (i) Applying 1st coat of two components modified polymer coating. (ii) Provn of glass fiber mess of 2 x 2mm immediately on alone coating. (iii) Apply 2nd coat of two components modified polymer coating after 72 hrs on horizontal and vertical surfaces.
Notes for Srl Item No. 49 : (i) Complete treatment shall be carried out by authorised applicator of waterproofing manufacturer as given in Appx 'B'. (ii) Water proofing material for mixing in cement mortar shall be measured and paid separately.
Demolition of PCC (unreinforced) of any description and in any position not otherwise specifically provided and removing the debris upto a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
Demolition of brick tiles or terracing tiles, single layer on roofs including removing the demolished material exceeding 1 km and not exceeding 2 km away from site and disposal off in low lying area as directed.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness recovered or only a part there of) including removing the demolished material not exceeding 200 m away from site and disposal off in low lying area complete.
M&L for water proofing treatment over RCC slab by applying oil bound bituminous primer @ 0.30 kg/Sqm and providing and laying 3 mm thick APP modified water proofing memberane weighing not less than 3.50 kg/sqm, reinforced with non woven polyester reinforcement matt weighing not less than 160 gm/Sqm polyester core, having soften point not less than 150°C, longitudinal tensile strength not less than 650 N/ 5 cm, tearing strength of 180 N, torch application, side overlap 75 mm and end overlap 100 mm and tucked into the chases including ponding test all as specified and directed.
Material and labour for wire brushing and cleaning top surfaces of roof slabs etc, including washing the roof surface with water and making the surface free from mud etc complete all as specified.
M&L for 15 mm thick screed bed or bedding layer in cement mortar (1:3) on roof surfaces parapet or vertical beam surface (horizental or vertical) finishing the surfaces even and fair complete all as specified. (Note :- Course sand (Toka sand) shall only be used in screed bed/plastering.)
M&L for Lime concrete in lime mortar ratio (1:3) using 40 mm graded brick aggregate, laid to slope as directed by Engineer in charge over RCC roofs as padding complete alll as specified. Note: Minimum thickness of lime concrete at lower end shall not be less than 50mm.
M&L for 20- 22 mm thick factory made PCC tiles of size 250mm x 250mm with grey cement and no pigment , bedded in cement mortar (1:4) 15 mm thick and joints grouted flush in CM (1:3) mixed with @ 5% of crude oil by weight of cement complete all as specified.
S&F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor and excluding flushing cistern, flush pipe and waste pipe.
S & F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe 32mm dia complete.
S&F in repairs vitreous china wash basin, white, flat back, size 580mm x 450mm excluding waste, chain and plug and porcelain stopper but including waste coupling and PVC waste pipe of 32 mm dia and fixed on existing brackets complete .
Supply only brass CP mixer for mixing hot and cold water screwed for iron pipe of 15 mm bore all as per Cera Cat part No. F2004405 or equivalent model of approved make from list of make attached in tender documents.
S & F in repairs, PVC connections 15 mm bore, 450 mm length, heavy duty, with PTMT nuts.
S&F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints fix to steel pipe or union complete all as specified and as directed.
S&F in repairs stop valves, chromium plated, fancy type, quarter turn, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe.
S&F stop valves, cast copper alloy, fancy type, quarter turn, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe.
S&F in repairs, 15 mm bore chromium plated, fancy type, quarter turn, bib taps cast copper alloy with crutch or butterfly handle, screwed for iron pipe, or for brass ferrule complete all as specified and as directed.
S&F in repairs, brass chromium plated tubular towel rail, 20 mm dia, D type, 600 mm long between flanges fixed with CP screws and wooden cleats.
S&F in repairs kitchen or laboratory sinks with drainage board made of stainless steel 1 mm thick fixed with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete.
S&F in repairs stainless steel plate rack made out of 1.00 mm thick sheet with chromium plated screws, rawl plugs of size 900 mm x 600 mmx 250mm complete all as specified.
Taking up or down old 15mm bore GI tubing including, cleaning for refixing and refixing same in new or old position in floor, wall or ceiling all as directed including provision of new fitting as per site requirement complete. Note:- The quoted rate is deemed to be including the cost of new fitting.
All as per item No. 71 above but 20mm bore.
M & L for 15 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 15 mm bore existing steel tubing and connections complete.
M & L for 20 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 20 mm bore existing steel tubing and connections complete.
Demolition of PCC (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) and removing the debris upto a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
M & L for 25 mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in floor finished even and fair.
M & L for non skid coloured ceramic tiles of size minimum 400mm x 400mm, 7 to 8 mm thick (square/rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with including 15 mm thick Screed bed or bedding layer in CM (1:6) including dismantling existing floor/ floor tiling including cement mortar bedding and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified. Note: Only course sand shall be used in screed bed.
M&L for non skid coloured ceramic tiles of size 600mm x 600mm, 8 to 9 mm thick (square/rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with including dismantling existing floor/ floor tiling including cement mortar bedding and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified. Note: Only course sand shall be used in screed bed.
S&F glazed ceramic coloured tiles 450 x 350mm, 7 to 8mm thick in verticle surfaces such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement pigmented to the match the shade of tiles laid over and including 10 mm thick rendering in cement mortar (1:4) as backing coat and finish the surface rough to receive the tile including dismantling existing hearth or wall plastering/ wall tiling including cement mortar bedding (but not backing) etc on brick or stone walls etc including racking out joints hacking for key and scrubbing removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar.
M&L for machine cut kota stone slab flooring 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing laid over and including 15 mm thick Screed bed or bedding layer in CM (1:6) complete.
All as per item No 81 above but in vertical surfaces such as skirting as directed at site including 10 mm thick rendering as backing coat in cement mortar (1:4) all as directed.
M&L for marble work (udaipur green) 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble and roundening to the edge of stone slabs on edges including M&L for 15 mm thick Screed bed or bedding layer in CM (1:6).
S&F PVC (SWR) 110mm bore pipes, single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps including taking down existing eaves gutters and rain water pipes (any size or pattern ), including all fittings, heads, shoes, bends, swan necks, etc. (measured overall as fixed along the centre line over fittings and accessories)
S&F 110 mm bore PVC (SWR) bends of any radius / shoe, fixed to PVC pipes as directed.
S&F in repairs 125 mm size CP grating of best quality.
S & F 75 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps including dismantling of existing drain pipes, jointed in cement mortar all as directed.
S & F 75 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, laid in trenches including dismantling of existing drain pipes, jointed in cement mortar all as directed.
S & F 100 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, laid in trenches including dismantling of existing drain pipes, jointed in cement mortar all as directed.
S & F 100 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps including dismantling of existing drain pipes, jointed in cement mortar all as directed.
All as per item No 90 above but except pipe.
S&F in repairs 75 mm dia stainless steel floor trap with grating incluing jointing to waste pipe fixed in cement concrete (1:2:4) type B-1, complete all as specified.
S & F in repairs 100 mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete.
S & F in repairs 75 mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete.
S & F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door.
S & F in repairs 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door.
S&F in repairs 100mm cast iron sanitary connection socket to fit WC out-let.
S&F in repairs 100mm cast iron Cowls.
M&L for rendering 15 mm thick in cement mortar (1:6) on internal wall surfaces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement including taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
M&L for rendering 15 mm thick in cement mortar (1:4) on external wall surfaces of brick work or concrete surfaces even and fair without using extra cement mixed with liquid water proofing material as per manufacturer's instruction including taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified. (Liquid water proofing material shall be measured and paid for separately.)
M&L for rendering 5 mm thick in cement mortar in (1:3) finishing the surfaces even and smooth on ceiling including taking down old cement plaster and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exceeding 15cm but not exceeding 30cm in width or girth; including cutting to edges, all mitres and stopped ends, etc.
M & L for Brick work using old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), including demolition of old brickwork or stone masonry of any type.
M&L for 75 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M & L for RCC (1:2:4) type B1 using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs and in kitchen shelves and the like, finished exposed surface fair and even including demolition of RCC of any description. (Reinforcement and form work shall be measured and paid separately)
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) for flat rough surfaces of concrete.
M&L for providing and injecting chemical emulsion for post constructional anti-termite treatment of soil under existing floors using emulsion @ 1.00 litre per hole, 300mm apart including drilling and plugging 12mm dia holes with CM (1:2) (1 cement : 2 coarse sand) to match the existing floors.
S&F 500 litres capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old water tank of any size and any type and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc all as directed.
S&F ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 210 gram).
M&L for machine pressed rubber moulded precast interlocking paver block with grey cement and pigment, factory made, any shape and size, conforming to IS 15658-2006 of 60 mm thickness, made out of M-35 grade & including minimum 25mm thick sand cushioning below interlocking paving block complete laid dry of any description in floors, aprons etc complete all as directed.
M & L for 75mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in sub base under floors.
Dismantling bricks work laid dry flat or on edge and pointed in any mortar.
M & L for preparation of newly plastered surfaces of internal walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint by using airless spray/ roller over and including a coat of acylic internal primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
Complete removal of existing treatment on wall (any number of layears) by scrapping with steel wire brushes or any other means, including filling depressions of scrapped surfaces and M & L for preparation of old plastered surfaces of internal walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint by using airless spray/ roller over and including a coat of acylic internal primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
M & L for preparation of newly plastered surfaces of externall walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of weather proof (antifungal) exterior emulsion paint by using airless spray/ roller over and including a coat of exterior emulsion primer. Make:- Apex Brand of Asian Paints/Excel Brand of Nerolac Paints/Berger Weather Coat Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
Complete removal of existing treatment on wall (any number of layears) by scrapping with steel wire brushes or any other means, including filling depressions of scrapped surfaces and M & L for preparation of old plastered external surfaces of walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of weather proof (antifungal) exterior emulsion paint by using airless spray/ roller over and including a coat of exterior emulsion primer. Make:- Apex Brand of Asian Paints/Excel Brand of Nerolac Paints/Berger Weather Coat Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
M&L for applying three coats of white wash on newly plastered surfaces of internal wall including preparation of surfaces.
M&L for two coats of white wash including preparation of old surfaces of ceiling.
M&L for preparation of newly plastered or unplastered surface and applying three coats of white wash on ceilings.
M & L for painting to old steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with one coat of synthetic enamel paint including preparation of old painted surfaces.
M & L for painting to old wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with one coat of synthetic enamel paint including preparation of old painted surfaces.
M&L for preparing surfaces of steel and iron work, new or old, of any description and girth, not otherwise described, and treated with one coat of tar or coal tar or black japan paint.
Internal Electrification
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, light fittings etc and removing the retrieved materials from site including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed.
M & L for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia ( medium duty ISI marked) and conduit fittings with and including 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 125 here in before but for socket outlet 5 pin, 6 Amp on same board complete all as specified.
All as per item No 125 here in before but for socket outlet 5 pin, 6 Amp on independent board but not below the switch board complete all as specified .
All as per item No 125 here in before but for one socket outlet 6 pin, 6/16 Amp multipurpose 2 in 1 on independent board with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable including provision of 2.5 Sq mm PVC insulated solid copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc.
All as per item No 125 above but for one light point controlled by two, two way switches .
S & F Switch semi modular with frame, flush type, single pole, one way, 5/6 Amp .
S & F Switch semi modular with frame cover, flush type, single pole, two way, 5/6 Amp .
S & F Semi modular switch socket combination, 5 Pin, 6 Amp, flush type, including decorative frame cover. (Note: Switch and socket shall be of same make.)
S & F Semi modular switch socket combination, multipurpose, 3 Pin, 6 Amp and 6 pin 16 Amp, flush type, including decorative frame cover. (Note: Switch and socket shall be of same make.)
S&F Blanking plate complete all as specified.
S&F, fan regulator electronic step type (1-5), socket type 230-240 Volt, AC supply, complete all as specified and directed.
S&F 6 Amps bell push switch, 230 volts AC, ISI marked complete all as specified and directed.
S&F electric / electronic bell, ding dong type, 230 Volt, AC supply complete all as specified.
S&F ceiling rose, 3 plate, surface bakelite type, Polycorbonate body, 6 Amps, 250 Volts AC, 20x50 mm, three terminal (ISI marked) complete all as specified.
S & F, In repair, Lamp holder of PVC/Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb.
S & F MCB, SP, 6 to 32 Amps, 'C' curve, 230 Volts, breaking capacity not less than 10 KA with over load and short circuit protection including taking down old unserviceable MCB complete all as specified.
S & F MCB, SPN, 40 Amps, 'C' curve , 230 Volts, 50 Hz, breaking capacity not less than 10 KA with over load and short circuit protection and including taking down old unserviceable MCB complete all as specified.
S & F MCB, TPN, 63 Amps, 'C' curve , 415 Volts, 50 Hz, breaking capacity not less than 10 KA with over load and short circuit protection and including taking down old unserviceable MCB complete all as specified.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, 8 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, IP-43 protection, 4 way, DB TPN 415 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB.
M & L for sub main wiring with 2 single core cable PVC insulated unsheathed of copper multi strandard conductor FRLSH cable of size 6 sqmm, 1100 votls grade drawing through in and including PVC concealed conduit 20 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface etc including taking down old unserviceable wiring 6 Sqmm complete all as specified. Note:- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit.
S & F 18/20 watt Retro LED tube light fitting, wall/surface mounted, IP 20 protection, conforming to IS 16106/IS 16107, minimum 6000K batten decorative type 4 feet long polycarbonate body, white, in built LED driver, power factor>0.95 , Make all as per Crompton Cat Part No. DMLN1LT8-16 (for batten) and Cat part No. LT8-20-865-2 (for tube light) including 18/20 watt tube rod or equivalent model of any make given in Appx 'B' connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size including taking down old existing light fitting all as directed.
S & F LED mirror light fitting of 12/14 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete including 12/14 watt tube rod all as model No LCL-14-CDL of Crompton with 14 watt rod or equivalent model of approved make from list of make attached in tender documents including connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size including taking down old existing light fitting.
S & F heavy duty Exhaust fan 300mm sweep single phase 230V, 50 Hz, 1400 RPM complete with louvers and making hole for proper fitting of exhaust fan and louvers complete.
Taking down serviceable/ unserviceable ceiling fans 1200/ 1400 mm sweep 230 V, AC, single phase from qtrs, dismantling the ceiling fan and taking out complete rewinding (if unserviceable) the same with super enameled copper winding wire of existing gauge and size including throughly cleaning all components of fan, oiling, varnishing the fan with and including replacement of rusted/ unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws and painting the fans and writing the MES No etc and refixing the repaired fan to respective qtrs complete all as specified and directed.
S & F energy efficient LED street light fitting of 45 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, PF>0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 40 watt LED lamp with GI brackrt-01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as per SYSKA cat part No. SSK-SLF-CF-45-WL or equivalent model of any make given in Appx 'B', Cat Part No. as approved by GE complete all as specified including taking down old unserviceable existing street light fitting of any type and capacity from pole along with accessories.
M & L in replacement of earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note :- (a) PCC chamber shall be constructed at least 1.5 m away from earth pit. Pipe for watering shall be provided in slanting manner. (b) 4mm dia GI wire and 15mm dia light grade GI protection pipe upto 7.5 metre shall deemed to be included in quoted rate.
KARTIK BUILDERS
M/s Kamal Builders
M/s Balvinder Singh Engineer and Contractors
RINKU BROTHERS
SUBHASH ARORA CONSTRUCTION CO
M/s NIRMAN BUILDERS
M/s RAMESH KUMAR VERMA CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .