Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.7 CrAccepted-AOC NATIONAL HIGHWAY BYE PASS CROSSING ATHWAJAN SRINAGAR 191101 KASHMIR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 191101 | ₹14.7 Cr | 1 | Accepted-AOC lOWEST |
| 2 | 2₹14.8 CrRejected-Finance CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹14.8 Cr | 2 | Rejected-Finance Not lowest |
| 3 | 3₹15.1 CrRejected-Finance | ₹15.1 Cr | 3 | Rejected-Finance Not lowest |
| 4 | 4₹17.8 CrRejected-Finance | ₹17.8 Cr | 4 | Rejected-Finance Not lowest |
| 5 | 5₹19.3 CrRejected-Finance OLD AIRFIELD ROAD RAWALPORA WANBAL SRINAGAR 190005 J K | SRINAGAR | SRINAGAR | J K | 190005 | ₹19.3 Cr | 5 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹10.9 L
Closing Date
27 Jul 2022, 6:00 pmClosed
CE AF UDHAMPUR
CE AF UDHAMPUR
PROVN OF EXTERNAL SERVICES FOR AKASH MISSILE (PH-I) AT AF STN AWANTIPUR
2022_MES_511701_1
CEAFU-17/2021-22
Open Tender
Civil Works
690 days
AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹3,000
ge af awantipur
₹10.9 L
Yes
2 Aug 2022
9 Mar 2022
29 Jul 2022
9 Mar 2022
27 Jul 2022
24 Jun 2022
9 Mar 2022 - 28 Mar 2022
Amount
Total amount of Sch 'A' PART-I ( BUILDING WORK)
Total amount of Sch 'A' PART-II ( INTERNAL WATER SUPPLY works)
SCHEDULE `A' PART-II (Sec-II) ( INTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S&F C P health Faucets with flexible tube 15mm dia for EWC including all connection complete and all as specified by Enr-in-Charge
Total amount of Sch 'A' PART-III (Sec-I) ( plumbing works)
SCHEDULE `A' PART-III (Sec-II) ( plumbing works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S&F 110 mm PVC (SWR) bend. including all connection complete and all as specified by Enr-in-Charge
S&F 75 mm PVC (SWR) bend including all connection complete and all as specified by Enr-in-Charge
Total amount of Sch 'A' PART-IV (Sec-I) ( ROAD/PATH/CULVERT/INTERLOCKING PAVER LOCKING PAVER BLOCK/RCC HUME PIPE CULVERT WORKS)
SCHEDULE `A' PART-IV (Sec-II) (ROAD/PATH/CULVERT/INTERLOCKING PAVER LOCKING PAVER BLOCK/RCC HUME PIPE CULVERT WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M&L for 200 mm thick (Compacted thickness) Granular Sub Base (GSB) of grading I as per MORTH Specification,surface formed, rolled and consolidated to required gradient and camber,using earth compactor of 8 tonne to 15 tonne capacity or compaction at OMC to achieve the min 98% density of MDD determined using modified proctor density determination method as per IS code to achieve min CBR30% ,laid in layers of consolidated thickness all as specified and directed.
M&L for 150 mm consolidated thick Wet Mix Macadam (WMM) with coarse aggregate of specified grade as per MORTH, spread,rolled and consolidated to required gradient and camber using mechanical paver/grader and tandom vibratory roller/earth compactor of capacity 8 tonne to 15 tonne or compaction at OMC to achieve the min 98% density of MDD determined using modified proctor density determination method as per IS code,laid in layers of consolidated thickness all as specified and directed.
Total amount of Sch 'A' PART-V (Sec-I) ( LIGHTENING PROTECTION WORKS)
SCHEDULE `A' PART-V (Sec-II) (LIGHTENING PROTECTION WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S & F epoxy insulator duly coloured with necessary fixing arrangement on wall and roof for fixing of down conductor complete all as specified and directed
Total amount of Sch 'A' PART-VI ( HOT WATER SUPPLY WORKS)
Total amount of Sch 'A' PART-VII( Section-I) (HARD STANDING WORK)
SCHEDULE `A' PART-VII (Sec-II) (HARD STANDING WORK) ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M&L 150mm dry lean concrete sub base over well prepared sub grade with coarse and fine stone aggregate confirming to IS: 383, the size of coarse aggregate not exceeding 25mm, aggregate 25mm, aggregate cement ratio not exceeding 15:1, aggregate gradation after blending to be as per table 600 :I, cement content not less than 260kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not less then 10 MPa at 7 days mixed in batching plant, transported to site laid with a paver with electronic sensor or suitable equipment/ method, compacting with 8-10 tonne vibratory roller, finishing and curing complete all as specified and directed.
Forming Construction joint 25mm deep x 10mm wide filled with PU sealing compound complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with PU sealing compound complete all as specified and directed.
Forming 20mm thick Expansion joints filled with pre-formed bituminous filler and top 25 mm primed and sealed with PU sealing compound complete all as specified and directed.
Total amount of Sch 'A' PART-VIII( Section-I) (EXTERNAL WATER SUPPLY WORK)
SCHEDULE `A' PART-VIII (Sec-II) (EXTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Material and labour for construction of valve chamber of size 900x 900 x 900 mm deep dimensions (LxBxH) (Over all internal dimension) for control valve etc. with PCC foundation, PCC block masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:- Valve chamber shall be provided with the following specifications:- (i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of block masonry. (ii) Walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks , setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth. (iv) 50 mm thick coping in PCC 1:3:6 type C1 over block masonry wall. (v) Entire plastered surfaces shall be treated with 3 coat of white wash. (vi) Chamber cover shall be of 3 mm thick MS sheet with 40 x 40 x 6 mm size angle iron frame with hold fast and locking arrangement including handle. Steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer.
All As per Item No- 14.01 but of size 750mmx750mmx750mm
All As per Item No- 14.01 but of size 500mmx500mmx500mm
Total amount of Sch 'A' -IX (Section-I) (EXTERNAL ELECTRIFICATION AND COMMON NATURE ITEM WORK)
Sch 'A' Part-IX (Section-II)( EXTERNAL ELECTRIFICATION AND COMMON NATURE ITEM WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M&L for transformer platform (3x2.5x1.2) mtr having necessary earth filling, PCC work and brick masonary with XPM fancing around 4 side and steps on one side including door with locking arrangements complete all as specified and shown on drawing Np. CE/TD-1129/96 sheet 1/2 &2/2.
Supply, installing, testing and commissioning AC, 3 Phase, 50 HZ, 800 KVA Capacity transformer copper wound step-down indoor type 11000/433 volts (at no load) double wound oil immersed naturally cooled with external cooling tubes, core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DY-11 (Vector Group) with neutral brought on secondary side (LV Side) and having tapping at +/- 2.5%, +/- 5.0% and +/-7.5% to be changed by means of hand operated off load tap changing gear. The maximum centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer shall be confirming to IS-1180 2014 level-2 BIS mark and comprising with the following standard fittings/accessories:- with the provision of extendable copper busbar to terminate multiple run of Cable. Note:-The provision of extendable copper busbar to terminate multiple run of Cable (b) Three Nos porcelain bushing with arching horn on HV side suitable for 11 KV complete with bushing copper rods, nuts and washers. (c) One cable box on LT side (secondary side) consisting of four No’s porcelain with copper bushing rods complete with nuts and washers with one No cable glands suitable for reception of taking out 01 No 3.5 core, LT 1100 Volts grade, PVC sheathed and PVC insulated heavy duty armoured cable including gland joint and jointing materials complete. (d) Oil conservator with filter type drain valve and oil level gauge. (e) Dehydrating breather with first fill dehydrating agent (Silica Jel). (f) Explosive vent. (g) Thermometer pocket on tank cover.
(h) One No 100mm dia type thermometer vapour pressure type having range (0-120) degree Celsius with metal guard having maximum temperature Indication with resisting device for transformer (i) Two earthing terminal on tank cover to facilitate of 32x6mm GI earth strip. (j) Rating plate and terminal marking plate. (k) Oil level gauge. (l) Oil drain filter valve. (m) Lifting lugs. (n) Oil filling hole with cap/plug with connection plate complete. (o) Air release valve/plug. (p) Four No’s plain solid cast steel detachable rollers. (q) First fill of fresh transformer oil confirming to relevant IS tested up to 40 KV dielectric strength at 2.5mm gap
Supply, fixing, connecting and commissioning with testing of company make ( automatic and manual operation) power factor improvement panel of capacity 200 KVAR including interconnection with LT panel with appropriate size of electric cable for transformer (outdoor/indoor) type panel factory made, weather proof, dust and vermin proof (IP54/IP 42) suitable for 1100V/440 V grade 3 phase 50 Hz AC supply floor mounted, fabricated out of 14 SWG MS sheet and having four Nos angle iron legs made out of 40x40x6mm long below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 Sqmm extension strips and connected with suitable size thimbles, lugs duly painted with grey epoxy powder coating after suitable chemical treatment, legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting, with required sheet metal enclosures, thimbles complete all as specified and directed. Note: LT cable required for connection from transformer to panel will be measured and paid seperately. Incoming Feeder:- A. Incomer MCCB 320 Amp, three pole , thermal based release with adjustable O/L, Adjustable S/C setting Class II front face, 36 KA rupturing cap, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier -01 Nos B. Metering Section - Digital Ammeter (0-300) Amps, digital volt meter (0-500) Volts, RYB indicateing Lamps , 1Set Control fuses, CTs 3. C. Insulated Busbar of Aluminium of 400A capacity for 3 phases, fixed on insulators, Busbars should be PVC sleeved with red. Yellow, Blue Colour, Busbar support should be of SMC/DMC - 1 set.
D. Multi 12 step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display. Outgoing feeder :- E. Accessories for 5 KVAR capacitor Bank - 2 Nos :- Capacitor duty contractor 5 KVAR with damping resistores which limits inrush current 440 volt, 3 Phase, 50Hz, Coil-220 Vac, MCB TP 25A havingbreaking capacity 10 KA with HEAVY duty capacitor, on/off indicators, Start /Stop push button. F. Accessories for 15 KVAR capacitor Bank - 6 Nos :- Capacitor duty contactor 15 KVAr with damping Resistors which limits inrush current 440 volts, 3 Phase, 50 HZ , Coil-220 VAC , MCB TP32A having breaking capacity 10KA with heavvy duty caoacuti ON/OFF indicators, start/stop push button. G. Accessories for 25 KVAR capacitor Bank - 4 Nos :- Capacitor duty contact 25 KVAR with damping resistors which limits inrush current 440 volts, 3 phase, 50 Hz, coil-220 Vac, MCB TP 63A having breaking capacity 10 KA HEAVY duty capacitor on /off indicators, start / stop push button. H. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switchin ON/OFF of fans depending upon the panel; 230 Vac 1500 rpm, 160 CU.M /H flying leads
I. Automatic power factor controller steps relay microprocessor base dfor switching ON and OFF of capacitors to display of voltage, current, active power. Apparent power display of COS O, THD current alarm indication for defective step, low power factor and access temperature. The relay having volt free C/o contact. Automatic detection and uses of optimum capacitor capable of 4 Quadrant operations and any phase offset requirement . Switching programme : LIFO combi filter, manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 550 Volt , 45 to 65 Hz. Current measuring 10 MA -5A suitable for CTx/1A and X/5A commissiong without additional setting and programming. Three decimal power reading. Phasing out of fault capacitor bank Automatically. J. All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of 14 swg thick MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer.
Supply, fixing, connecting and commissioning with testing of company make ( automatic and manual operation) power factor improvement panel of capacity 100 KVAR including interconnection with LT panel with appropriate size of electric cable for transformer (outdoor/indoor) type panel factory made, weather proof, dust and vermin proof (IP54/IP 42) suitable for 1100V/440 V grade 3 phase 50 Hz AC supply floor mounted, fabricated out of 14 SWG MS sheet and having four Nos angle iron legs made out of 40x40x6mm long below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 Sqmm extension strips and connected with suitable size thimbles, lugs duly painted with grey epoxy powder coating after suitable chemical treatment, legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting, with required sheet metal enclosures, thimbles complete all as specified and directed. Note: LT cable required for connection from transformer to panel will be measured and paid seperately. Incoming Feeder:- A. Incomer MCCB 160 Amp, three pole , thermal based release with adjustable O/L, Adjustable S/C setting Class II front face, 36 KA rupturing cap, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier -01 Nos B. Metering Section - Digital Ammeter (0-200) Amps, digital volt meter (0-500) Volts, RYB indicateing Lamps , 1Set Control fuses, CTs 3. C. Insulated Busbar of Aluminium of 200A capacity for 3 phases, fixed on insulators, Busbars should be PVC sleeved with red. Yellow, Blue Colour, Busbar support should be of SMC/DMC - 1 set
D. Multi 8 step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display. Outgoing feeder :- E. Accessories for 3 KVAR capacitor Bank - 1 Nos :- Capacitor duty contractor 3 KVAR with damping resistores which limits inrush current 440 volt, 3 Phase, 50Hz, Coil-220 Vac, MCB TP 10A havingbreaking capacity 10 KA with HEAVY duty capacitor, on/off indicators, Start /Stop push button. F. Accessories for 7 KVAR capacitor Bank - 1 Nos :- Capacitor duty contactor 7 KVAr with damping Resistors which limits inrush current 440 volts, 3 Phase, 50 HZ , Coil-220 VAC , MCB TP20A having breaking capacity 10KA with heavy duty caoacuti ON/OFF indicators, start/stop push button. G. Accessories for 10 KVAR capacitor Bank - 2 Nos :- Capacitor duty contact 10 KVAR with damping resistors which limits inrush current 440 volts, 3 phase, 50 Hz, coil-220 Vac, MCB TP 25A having breaking capacity 10 KA HEAVY duty capacitor on /off indicators, start / stop push button. H. Accessories for 15 KVAR capacitor Bank - 2 Nos :- Capacitor duty contact 15 KVAR with damping resistors which limits inrush current 440 volts, 3 phase, 50 Hz, coil-220 Vac, MCB TP 32A having breaking capacity 10 KA HEAVY duty capacitor on /off indicators, start / stop push button. I. Accessories for 20 KVAR capacitor Bank - 2 Nos :- Capacitor duty contact 20 KVAR with damping resistors which limits inrush current 440 volts, 3 phase, 50 Hz, coil-220 Vac, MCB TP 50A having breaking capacity 10 KA HEAVY duty capacitor on /off indicators, start / stop push button.
J. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switch on /off of fans depending upon the panel; 230 Vac 1500 rpm, 160 CU.M /H flying leads K. Automatic power factor controller steps relay microprocessor based for ON /OFF switching ON and OFF of capacitors to display of voltage, current, active power. Apparent power display of COS O, THD current alarm indication for defective step, low power factor and access temperature. The relay having volt free C/o contact. Automatic detection and uses of optimum capacitor capable of 4 Quadrant operations and any phase offset requirement . Switching programme : LIFO combi filter, manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 550 Volt , 45 to 65 Hz. Current measuring 10 MA -5A suitable for CTx/1A and X/5A commissiong without additional setting and programming. Three decimal power reading. Phasing out of fault capacitor bank Automatically. L. All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of 14 swg thick MS sheet factory made duly powder coated front and REAR door open able with locking arrangement complete with foundation as required or recommended by manufacturer.
Supply and fix servo controlled Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 1 x 800 KVA.
Supply and fix servo controlled Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 150 KVA.
Supply and installation of HT 11 KV ,3 phase, 50 cycles totally enclosed metal clad load break switch vacuum based for transformer having rated voltage 12 kV and rated current 400 Amp .
Supply,installation, testing and commissioning of 11KV, 400Amps, 31.5KA for 3 Sec HT Vaccum circuit breaker panel indoor vacuum bus coupler panel confirming to IEC 62271-200, IAC-AFLR-31.5KA for 1 Sec, LSC2B-PM class front accessed with comprising of following material: (a) 400 A continuous rated electrolytic copper bus bars, droppers and bus bars should be insulated with full system voltage sleeves of Reychem or eq make. (b) Side panel for housing circuit breaker. (c) One no. set of isolating plugs and socket. (d) One set of mechanical interlock and auto shutter gear. (e) One no. VCB 350 MVA manually operated spring closing mechanism complete with DC shunt trip coil and aux switches ON/OFF indication and push button for open and close circuit. (f) One set of green and pilot lamp with filament for indication.
M&L for factory made sheet metal encloser (junction pannel) made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 120X75X45cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar 100 Amp of lengh 75 cm, mounted on insulators including and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs all as per directed and specified by Engr-in-Charge.
M&L for factory made sheet metal encloser (junction pannel) made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 180X150X45cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium extendable bus bar 1300 Amp of lengh 150 cm, mounted on insulators including and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes , neccessary earth work and PCC foundation for grouting of four legs all as per directed and specified by Engr-in-Charge.
M&L for cutting of existing road for laying of XLPE cable of any size including necessary excavation and earth work including repairing the same as per existing with pre mix bituminous carpet complete all as specified and directed by Engr-in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 600X600X6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate not less than 1.5 mtr below normal ground level) connected to galvanised earth strip 32x6 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of GI or steel all as shown in electrical plate No 5 including charcoal dust common salt, 20mm bore GI medium grade watering pipe funnel with wire mesh, including 40mm dia GI pipe light grade for protection of GI strep including PCC pit 1:2:4 type B-1 using 20mm graded stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm steel bars 100 mm center to center both ways i.e. horizontal and vertical complete all as directed by Engr in charge and testing for required value complete. Note: If earth resistance of earthing is not found satisfactory it will be done by the contractor on his risk and cost.
M & L for route indicator made out of PCC 1:2:4 and MS bar 8mm of size 90cmx35cmx50mm HT 11KV under ground cable complete all as specified and directed by Engr-in-Charge.
Supply and erect GI pipe 50mm dia 2.5 Mtr long finial taper plug, including painting externally with two coats of aluminum paint over a coat of red oxide primer including writing number complete all as specified.
Supply & fixing post top lantern light fitting 35 Watt aluminum landscape luminaire with high power LEDs as light source all as specified and directed.
S&F copper round cable three core PVC insulated multi standard 2.5 sqmm 230V complete all as specified and directed
Supply & fixing LED light street light made up of pressure die cast housing with toughened glass and individual high power LEDs IP66 protection and impact resistance of IK07 of rating 70 watt, 5700 K
Supply & fixing LED flood light made up of pressure die cast housing with toughened glass and individual high power LEDs IP66 protection and impact resistance of IK07 of rating 70 watt, 5700 K
Supply and fix water proof junction box conforming to IP 65 of size 300 mmx 250 mm x 100mm made of MS sheet 1.6mm thick, front door openable with fixing screw, painting with two coats of synthetic enamel paint over a coat or red oxide primer including aluminum bus bar 4 Nos of suitable rating mounted on epoxy based post insulators and drilled holes for cable connection ,MCB 10 Amps single pole o1 Nos all as required at site or directed by Engr in charge.
Supply insulating Rubber mat of 1 meter x 2 meter x 19 mm all as specified and directed.
M&L for shifting of existing HT panel by disconnecting the same from existing electric circuit to new place within 10 mtr lead maximum and realign the same with other VCB and making the connections complete all as sepecified and directed ( Note: Termination kit required for alignment will be measured and paid separetely)
S & F 33 KV post insulator with GI fitting to be installed on existing structure with minor modification as required on site.
Supply, installation, testing and commissioning of OLTC transformer of capacity 33/11 KV, 6.3MVA , step down, outdoor type, 3 Phase, 50 HZ copper wound, two winding, core type transformer as per IS-2026 star vector group & IEC :76 , ON load Tap changer on HV side (+) 5% to (-) 15% in step of 1.25 %, Outdoor type, HV/LV bare bushing condenser type terminations with fitting and accessories a under with first fill of oil all as specified and as directed by Engineer-in-charge. Accessories: (i) Buchholz Relay with alarm abd trip contact and shut off valve (ii) Oil Temperature indicatior 150 dia with alarm and trip contact. (iii) Winding Temperature Indicator with alarm and trip contacts. (iv) Marshalling box 200 TB (MK) (v) Magnetic Oil level Gauge (vi) Pressure release valve (PRV) with trip contacts (vii) Conservator with oil filling hole with cap and drain plug and with built in diaphram to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking (ix) Thermometer packets with thermometer (x) Silica gel breather (xi) Air Release plug (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized Aluminium Rating and diagram plate (xvi) On Load Tap Changer (OLTC) (xvii) Top filter valve
(xviii) Bottom drain cum filter valve (xix) Jacking lugs (xx) RTCC Panel (xxi) AVR Panel (xxii) 72.5 KV Neutral CT of ratio (150-75/1) -01 No (xxiii) 12 KV Neutral CT of ratio (900-450/5) -01 No Note : (i) The erection of transformer shal be done under the supervision of manufacturer's auth rep & certificate in this regard shall be submitted by contractor duly signed by auth rep of manufacturer & Engineer-in-Charge. (ii) RTCC and AVR Panel shall be suitable for automatic voltage regulation with master follower scheme with tap position indicator as per tap indication in the OLTC mechanism. RTCC should also be provided with control gear in respect of fan ON/OFF indication, auto & manual control switch AC supply on and tap changer in progress indication lamp, tap struck indication and alarm.
Supply, install, testing & commissioning of out door type SF-6 circuit breaker 33 KV nominal voltage 3 Phase, 50 HZ as per IEC-62271-100 complete with all accessories and of the following technical specifications complete all as specified and as directed by Engineer-in-Charge. (i) Highest system voltage between phase : 72.5 KV (ii) Rated normal current : 1600 Amps (iii) Rated power frequency withstand voltage : 160 KV (iv) Rated lightning impulse with stand voltage 350 Kvp (v) Short circuit breaking current : 31.5 KA (vi) Short circuit making current : 80 Kap (vii) Rated duration of short circuit 3 seconds (ix) Minimum creep age distnace to ground ; 1820mm (x) Type of mechanism enclosed in housing ; Motor operated spring-spring (xi) Rated operating sequence : 0-0.3 Sec-CO-3 MIN-CO (xii) Rated closing/tripping voltage : 110/220 VDC (xiii) Current of closing/tripping coil : 6 A max at 110 VDC (xiv) Rated current for terminal connections : 630 Amps (xv) Motorised spring charging m,echanism with integral spring charging handle for manual spring charge.
Supply and installation of Single Phase, 33 KV PT outdoor transformer incommer CT 150-100/.577-1-1A for metering & protection, including junction box comlete, oil cooled, insulation level -140 KV/325 KVp short time current rating -50KA/1 Seconds, 3 core of above setting, 15VA/0.2 class accuracy with oil as per IEC-60044-1 & IS-2705 complete all as specified and as directed by Engineer-in-Charge with following accessories :- (i) Differential protection current Ratio : 150-100/0.577 (ii) Over current & earth protection current ratio : 200-100/1 (iii) Metering current ratio : 200-150/1
Description all as serial item No 16.35 but CT suitable for Line complete with all acessories as under :- Protection & Metering CT of current Ratio : 150-75/0.577-1-1 for 33 KV line. Accuracy : Class 0.2
Supply, installation , testing and commissioning of battery bank comprising of 40 batteries 2 V each of 90 AH capacity each for an output voltage for 120 AH 99 Volt and DC control panel etc including initial charging complete and wooden platform for batteries incl 10A/20 A battery charger for 220v ,100 AH battery and DC control panels etc including Batteries.
M/L for RCC Cable duct in switchyard for control cables and power cables including GI 8 mm steel checked covers duly painted, including side TEE GI steel strip/ TEE with angle iron sypports fitted in ducts for making cable racks as per site requirement minimum depth 1.5 mtr and width 1.0 mtr all as specified and directed.
Supply, installing, testing & commissioning silent deisel engine driven Generating set 415 Volts, 3 phase 4 wire, engine water cooled as per IS: 10001/10002 and Alternator as per IS:1334 complete with relay panel for automatic starting ON mains failurer, control panel having meters, sound proof canopy and foundation etc. as per manufacturers design of capacity 910KVA at NTP comprising of the following components :- (a) Diesel Engine . (i) Radiator/Radiator fan (ii) Coupling (iii) Fly wheel (iv) Fly wheel housing complete with starter gear ring and coupling (v) Fuel pipes (vi) Air cleaners (vii) Fuel and lub oil filter (viii) By pass filter (ix) Fuel pump (x) Asbetose rop (xi) Water pump (xii) Lub oil pump (Gear type) (xiii) Electric starter DC (xiv) Battery Charging Generating (DC Alternator) (xv) Industrial silencer (xvi) Lub oil cooler (xvii) Flexible pipe for silencer (xviii) DC volt meter (xix) Water temperature gauge, Lub oil pressure gauge
(xx) Speedo meter and Engine hours running meter (xxi) Display for fault (xxii) Suitable size of turbo charger as per manufactures design (b) Synchronous alternatro 910KVA, 1500RPM, 15 Volts, 50Hzs, 3 phase system, self excited, self regulated confirming to IS-4722 of 1992 voltage regulation 1.5% class of regulation H class regulation within 1% from no load to full load and from hot to cold Alternator . (c) Acostic enclosure with natural air circulation without loss of any power for ventilation fan. The enclosure shall be modular in construction with hinge bolted structure to provide easy dismantling and shall be made out of high quality CRCA sheet steel of 1.6mm thick with sufficient accessaries for maintanace work, openable and lockable door with air tight rubber gasket, interior lighting arrangement (01 Nos 20 Watts with ON/OFF switch) to meet latest (d) Fuel tank suitable capacity (e) Base frame not less than 60cm above ground level made out of suitable channel duly reinforced and provided with adequate numbers of anti-vibration pads to ensure minimum vibration as recommended by manufacturers. (f) Starting arrangement with suitable capacity battery bank including battery charger upto 24 volts NOTE (i) Load test will be carried out afer installation in the presence of Testing Officer.
Description all as per srl item No. 15.41 & 15.42 but of 320 KVA .
Description all as per srl item No.15.41 & 15.42 but of 100 KVA .
Description all as per srl item No. 15.41 & 15.42 but of 40 KVA .
Total amount of Sch 'A' PART-X (Section-I) (INTERNAL ELECTRIFICATION WORK)
Total amount of Sch 'A' part-XI (AREA DRAINAGE WORK)
Total amount of Sch 'A' PART-XII (SEWAGE DISPOSAL WORK)
Total amount of Sch 'A' PART-XIII (SEC-I) ( FENCING & GATE WORK)
Sch 'A' PART-XIII (SEC-II) (FENCING & GATE WORK ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and lying of 1m dia concentrina coil complete all as specified and as directed .
Total amount of Sch 'A' part-XIV (SITE CLEARANCE , EXCAVATION AND EARTH WORK)
Total amount of Sch 'A' PART-XV (SEC-I) ( Addn / Altn / improvement to MRS Sub Stn BUILDING WORKS)
Sch 'A' PART-XV (SEC-II) (Addn / Altn / improvement to MRS Sub Stn BUILDING WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S&F 4mm thick E-board of M/s Everest Industries Ltd or equivalent approved make with E- grid suspended ceiling grid system (exposed grid section) as in ceiling all as specified and directed with and including following :- (a) 4mm thick E- board ( High pressure steam curved pre-primed self embosed textured designer board) (b) E- Grid component shall consist of :- (i) Grid size 600X600 mm with GI main runner 39.00X 24.70 X 0.80 mm and cross tee 29.00X 24.70X 0.80 mm and wall angle 22.20X 22.20X 0.65mm. (ii) 4mm thick E-board shall be placed in grid of E-Grid suspended ceiling grid system duly suspended with 4mm dia G.I bar hangers fixed with steel dash fastner or from purlin with butterfly clip providing provision for light fixtures, air conditioning diffuser and duct etc as directed. (iii) The exposed surface of E-Grid component (i.e main runner-3600 cross tee-600 angle3050) are pre painted polyster coated galvanised steel of not less than 20 micron. (iv) Some adjustment of the primary grid may be required to support extra load.
Total amount of Sch 'A' part-XVI ( Schedule of Credit Work) SCHEDULE "A" PART-XVI( SCHEDULE OF CREDIT ) Amount of Credit of RS 22650 .00 for retrieved material mentioned in Sch 'A' Part-XVI of Tender documents in PDF form which will be deducted offline during acceptance of Tender