Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.3 LAccepted-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹55.6 L+₹1.8 L (3.41%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹76.8 L+₹23.0 L (42.8%)Rejected-Finance 1ST JEET APARTMENT GROUND FLOOR NEAR RATANADA CIRCLE JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | Rejected-Technical 12 53 CHOPASNI HOUSING BOARD JODHPUR 342 008 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342008 | - | Rejected-Technical MOU/ EXPERIENCE AS PER APPX A TO NIT PARA 8A(III) AND 8C(I) NOT UPLOADED |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
22 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura
PROVN OF ROOF TOP PANEL (50KW) FOR A BUILDING UNDER GE (EAST) MATHURA
2021_MES_425154_3
CWE/MTR/E/79 of 2020-21
Open Tender
Civil Works
Item Rate
120 days
HQ CWE Mathura
Class C
7 documents required · 7 mandatory
₹1,000
GE (East) Mathura
₹1.1 L
Yes
7 Sept 2021
29 Jun 2021
24 Jul 2021
29 Jun 2021
22 Jul 2021
8 Jul 2021
60 days
Amount
Schedule 'A' Part I SOLAR POWER GENERATION PLANT Design, Supply, install, testing, connecting, charging and commissioning of solar PV modules to meet cumulative rated capacity of 50 KW. Modules will be of poly Crystalline type silicon modules with minimum 72 cells and minimum rating of 335 Wp with positive tolerance, with minimum 1100 mm cable length. Module efficiency of not less that 17.0% fill factor >0.7, module will be PID resistant, module connector suitable for MC4/Bizlink and juntion box with minimum, IP 67 rating. Module NOCT (Nominal operating cell temperature) will be 45±3° with temperature coefficient of power ˂0.4%/°C, and will be suitable for operation from - 20° to + 60°C ambient temperature. Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessories like fuses, array/string junction box etc, Modules will be certified for relevant dust standards (Applicable standard would be IEC 60068-2-68). Modules shall be deployed with RF id tag inside lamination as per MNRE guidelines. After successful commissioning of Solar Power plant the guaranteed electrical generation of power should not be less than the 90% after ten years of period and should not be less than 80% after 25 years of period of the output watt capacity of solar plant i.e. 50 KW. Solar PV modules shall have manufacturer’s warranty against all manufacturing defect, raw material, workmanship, inspection and testing etc. for a period of minimum 10 years from the date of commissioning. Modules shall be certified as per IEC 61215- Edition -ll, IEC 61646 and IEC 61730-1 & 2 ISO 9001: 2008 Quality Management System, ISO 14001 : 2004 :Environmental management system or equivalent and other applicable IEC/IS standards.
NOTES :- Each PV module & solar cells should be manufactured indigenously i.e. Indian made & should be BIS approved & IEC certified. The bidder shall produce all the certificate from manufacturer. The contractor shall procure & install module and cells of the same Indian manufacturer, the department reserve the right to inspect the manufacturing facility of OEM during the process of manufacturing of cells and modules. Make :- The make of SPV shall be Vikram Solar / TATA Solar / Adani / Renew Sys / Novasys / Warree / Havells.
Solar Module should have high conversional efficiency of minimum 17.0% each module and four Sqmm UV resistant cable approx 1.2m length and terminated with connectors MC4 compatible connectors. Glass with anti reflective coating, excellent performance in low light, torsion and corrosion resistant with anodized aluminum frame.
Solar PV modules shall have Warranty for a minimum period of 10 years against all material/manufacturing defects and workmanship, inspection & testing. PV Modules shall be warranted for their output Peak Watt capacity of solar plant i.e. 50 KW which should not be less that 90% at the end of 10 years and 80% at the end of 25 years from the date of successful commissioning. The warranty from manufacturer (OEM) shall be obtained by the contractor in original for a period of not less than 10 years.
Each PV module must use a RF identification tag (RFID), which must contain following information :- (i) Name of the manufacturer of PV modules & Solar cells. (Indigenously made). (ii) Month and year of the manufacture (Separately for solar cell and modules). (iii) Country of origin (Separately for solar cell and module). (Made in INDIA only). (iv) I-V curve for the module. (v) Peak Wattage, Im, Vm and FF for the module, also Unique serial no and Model No of the module. (vi) Date and year of obtaining IEC PV module qualification certificate. (vii) Name of the test lab issuing IEC certificate. (viii) Other relevant information on traceability of solar cells and modules as per BIS approved specification. Note :- The contractor will ensure site visit by an engineer of solar power firm atleast once in two months or as and when required for fault tracing and rectification. The design and drawings, duly vetted by any IIT/NIT/Govt. Engineering College & will be approved from Accepting Officer.
Design, Supply, fixing and fabricate modules mounting structure (for 50 KW Solar power Plant) seasonal tilt type made of hot formed hollow steel section as per IS 4923 : 2017 & designed as per IS 800 : 2007 & structure member should be hot dipped galvanized mild steel with coating not less than 85 microns and suitable to withstand wind speed upto 200km/hr and electrolytically compatible channels, bracing, purlins of any size, electromagnetic washers, nuts, bolts including cutting, drilling etc. The design should be as per IS code and suitable for the wind speed (as per Wind Zone or 200 km/hr whichever is higher, with correction of wind load at solar panel installation height), sun light, seasonal variation and climatic condition of the plant location. The design life should be more than 25 years and grade of steel should be YST310. Properties of RHS will conform to IS 4923 : 2017. HDG Fasteners of 4.6 grade and 8.8 grade for structure. The module mounting structure should be suitable for easy removing and refixing / replacing of PV modules of the Solar Plant. All MMS, foundation & fixing arrangement shall be according to the design and drawings, duly vetted by any IIT/NIT/Govt. Engineering College & approved from Accepting Officer. Each structure should have angle of inclination as per the site conditions to optimize the maximum power generation in a year and provisions for Tilting of solar panels for seasonal variation. However to accommodate more capacity the angle of inclination may be reduced/ increased until the plant meets the specified performance power generation requirement of 50 KW.The bidder shall carryout and submit design of foundation for fixing of modules mounting structure (MMS) along with design calculations, detailed structural & architectural drawings, duly vetted by any IIT/NIT/Govt. Engineering college & shall be got approved from Accepting Officer including material & labour for construction of necessary foundation ( Design mix, reinforcement, necessary formwork, MS plate & including all required MS Bolts, nuts etc. complete) and associated work complete as per the approved design & drawings.
NOTES:- Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, Its fasteners, nuts and bolts. Necessary protection towards rusting needs to be provided either by coating or anodization.
MMS design & foundation design should be as per relevant IS code and shall be supported with design software reports & design calculations duly vetted by any IIT/NIT/Govt Engg college and shall be submitted for the approval of the Accepting Officer along with loading calculation sheet.
The MMS structures and steel shall be as per latest IS 2062:2011 and galvanization of the mounting structure shall be in compliance of latest IS 4759.
The fasteners used should be made of stainless steel of grade SS316. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from the SPV panels.
PV modules shall be secured to support structure using screw fasteners and/or metal clamps. Screw fasteners shall use existing mounting holes provided by module manufacturer. No additional holes shall be drilled on module frames. Module fasteners/clamps shall be adequately treated to resist corrosion.
The PV array structure design shall be appropriate with a factor of safety of min. 1.
Adequate spacing shall be provided between any two modules secured on PV array for improved wind resistance.
Regarding civil structures the bidder needs to take care of the load bearing capacity of the roof and need to arrange suitable structures based on the quality of roof.
The structures should be fixed on roof top as per manufacturer's design with use of M-20 concrete mixture, water proofing shall be provided in the area where MMS is fixed on roof slab.
The total load of the structure (when installed with PV modules) on the terrace should be less than 60 kg/m2. The load shall be well distributed so that point loads are well within the limits.
The minimum clearance of the structure from the roof level should be sufficient to allow ventilation for cooling, also ease of cleaning and maintenance of panels as well as cleaning of the terrace.
The array shall be located sufficiently inside the boundary wall of the terrace (parapet wall) and should not be projecting out. PV array shall be installed in the terrace space free from any obstruction and/or shadow. PV array shall be installed utilizing optimum terrace space to minimize the effects of shadows due to adjacent PV panel rows.
Adequate spacing shall be provided between two-panel frames and rows of panels to facilitate personnel protection, ease of installation, replacement, cleaning of panels, and electrical maintenance.
Warranty of MMS shall be of 10 years and Service life 25 Years. Any defect arising with in 24 Months the defective part of the structure shall be replaced by the contractor at his own cost. MAKE : STOLER / SRPL / ARS SOLAR STRUCTURE. Note for items 1 & 2 :- Within one month of placing of work order No 1. The contractor will submit a detailed project Report of their scheme & planning for the production of 50 KW of power. In detailed project report, the bidder shall outline the various issues pertaining to the project and various type of materials to be used & will submit their action plan & CPM chart for effective & timely execution of the project.The main contractor and manufacturer shall give Warranty of Module mounting structure for 10 years and Service life of 25 Years.
Supply and laying cable in trenches or fixed on structure on wall floor ceiling etc of power control cables single core double insulated solar cable with fine copper wire multistranded, single core 4 Sqmm FLX-SOL-XL type, Tuv certified according to latest regulations -40°C to +120°C (permanent) UV, ozone and hydrolysis-resistant including all accessories and fixing arrangement complete all as specified and as directed. (in Solar Panels) Make: Siechem, Lapp, Polycab.
Supply installing, testing & commissioning DCDB box comprising of 8 incoming, 8 outgoing complete with fuses, connector, SPD, isolator in polycarbonate box IP65.
STRING TYPE INVERTER : Supply, Installation, Testing & commissioning Grid connected solar inverter of 50KW AC capacity microprocessor based having following specifications :- (i) Ambient temp : 4° C to 60° C (ii) Relative humidity : 0-100 % non-condensing (iii) Environmental condition : outdoor, wet location (iv) Protection degree : IP-65 (v) Pollution degree : IV (vi) Safety class : class I metal enclosure (vii) MPP Tracker 2MPP trackers (viii) No. of inputs minimum 4 Nos MC4 (ix) Frequency rated : 50 Hz (x) Total Harmonic distortion shall be less than 3% (xi) Power factor shall be more than 90% at any load (xii) Inverter Efficiency >93% (In case of 10 KW or above with inbuilt galvanic isolation) >97% (In case of 10 KW or above without inbuilt galvanic isolation) >90% (In case of less than10 KW) (xiii) External communication: RS-485 Port (xiv) Grid frequency Tolerance range +3 or more (xv) No load losses less than 1% (xvi) Protection against DG set run & grid isolation Note :- Inverter shall be capable of synchronisation with grid supply and DG Set supply. Make (DELTA, STRUDER, Schnider, ABB, Goodwe)
INPUT (DC) - M50A Max recommended PV module - 63kWp, Max input voltage-1100 Volts, DC voltage range -200-1000 Volts, Start-up voltage >250 Volts, Start-up power -40 Watt, MPPT voltage range -200-1000 Volts, MPP voltage range full power -520-800 Volts, Nominal DC voltage -600 Volts, Max input current (total MPPT 1 /MPPT 2)- 100 Amp (50 Amp/50 Amp), Max short circuit current total (MPPT 1/MPPT 2)-120 Amp (60 Amp/60 Amp), Nos of Independent MPP tracker -2 Nos, Nos of DC input -12, Max asymmetry -60/40% : 40/60% Input connection type - Multi connect MC4, DC connect switch -Yes (inbuilt)
Output (AC) : (i) MPPT of inverter not less than 50 kW ( capacity of inverter) with associated control and protection devices integrated to convert DC Power into 3 Phase AC voltage, along with grid synchronizing facility - voltages 415 Volt AC, 3 Phase 50 Hz, Peak Effficiency > 98%, THD < 3% , Temp range -10°C to +55°C power factor Control range > 0.95 lead or lag including all measuring meters complete - 01 Set (ii) Protection switchgear based with overlead, short circuit, earth fault and instantaneous over current digital metering system. NOTE : The Inverter (PCU) shall be warranted for minimum 5 years against all material / manufacturing defects and workmanship after date of completion of work.
Supplying, fixing and testing of zero export device and DG controller panel suitable for 2 Nos of 250 kVA DG sets and 1 Nos of 50 kW solar invertor complete comprising of following : Type - DG & GRID EXPORT SOLUTION with all nessary eqipment. Make : SRR / S3 Energy / Universal Switch gear. Supply Voltage - 230 Volts AC, 50 Hz (UPS Supply), Operating temperature - 0-55 Degree Celsius, Humidity - 5% to 95 % non-condensing, Encloser protection - IP54, Panel installation system - Base mount, Enclosure Material - mild steel, Enclosure type - Indoor, Shock - 15 G, 11 ms, Data logging - Applicable, MODBUS RTU BAUDRATE/PARITY&TCP/IP- Configurable, Nos of invertor - 01 Nos (50 KW ), Multi-function Metre, Class 1 with RS 485 Port - 03 Nos Make : Schenider / secure / L&T
S&F Cable Connectors (MC4 male & female) 1000V (IEC/CEI), 600V (UL), With safety clip that requires a tool to unlock (NEC2008 compliant) Certified for applications with modules according to IEC 61730, Safety class II, Directive 2002 / 95 / EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment - with Minimal voltage drop, High current-carrying capacity, Minimal power loss, Minimal contact resistance, High durability contacts withstand up to 1 million mating cycles, Operating temperatures up to 350°C, higher temperatures permitted for short periods complete all as specified and as directed.
S&F nominal 3.0 mm + 10% thick insulating mats made of elastomer conforming to IS-15652: 2006 and meeting the requirement of IS- 5216 (Part -1 & 2) IS 8437, IEC-479 Pub -1 along with suitable adhesive / homebound, PV resin water proofing compound and sealing material as per recommendation of Annex 'A’, Clause- 'C’ of IS- 15652 and suitable for class - C upto 33 kV complete all as specified and as directed.
Supply and laying flexible DWC HDPE pipe ISI UV resistant in trenches under floor, wall etc 32 mm inner dia and 40mm outer dia.
M&L lightening arresters ESE type with 4 metres, mounting arrangement. Make: Protec, ASHLOK, ABB, Green Power.
Supply and installation, commissioning and testing of AC panel box 415 Volts grid panels outdoor type IP-65 for power evacuation and grid interconnection system, incoming 1 Nos 160 Amp MCCB outgoing 1 No 160 Amp MCCB with copper busbar & digital multifunction meter with three phase LED indicator, Grade to Electrolytic Grade E91 AL with current density 0.8A/mm^2, manufactured by CPRI approved manufacturer.
S&F of 10 Core x 1.5 Sqmm Copper Flexible cable PVC insulated and PVC sheathed 1100 volt grade cable complete all as specified and directed.
S&F of 2 Core x 1.5 Sqmm Copper Flexible cable PVC insulated and PVC sheathed 1100 volt grade cable complete all as specified and directed.
S&F of single mode fiber optic cable (FOC) 4 core all as specified and directed. Make: FINOLEX / LAPP / LEONI 200
S&F of Communication RS 485 MODBUS Copper cable size 2 x 2 x 0.5 Sqmm all as specified and directed. Make: SCHNIDER / EMERSEN / GEIP
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground including with drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 mm X 3 mm aluminium strip complete all as specified and as directed.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground including drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32mm x 6mm galvanised mild steel strip complete all as specified and as directed.
S&F self priming 1 HP Monoblock Pump Set incl DOL Starter, Single Phase 240V, 1500 RPM,delivery size 25mm and head upto 40mtr, discharge range 3000-800 ltrs/hour complete with connecting & testing including fixing of suitable sheet canopy for protection of motor from raining complete all as specified.
S&F hose reel drum with 20mm dia rubber hose pipe 36 mtr long ISI marked IS 444 hose reel with mounting glove valve 20mm including adjustable gun nozzle complete all as directed.
M&L Plain Cement Concrete 1:2:4 type B1 using 20mm graded stone aggregate as in foundation, filling mass concrete complete all as specified and directed.
Supply, installing, testing and commissioning of CPRI approved factory made LT Outdoor Type Panel box, floor mounted, single phase 200amp and made out of 3.15mm thick CRCA sheet double door, front openable door with locking arrangement, dust, vermin and water proof duly mounted on 40 x 40 x 4mm thick angle iron stand 04 legs 750mm long each 450 mm grouted in PCC foundation 1:2:4 type B-1 and 300mm above foundation and including necessary incoming and out going cable connection with proper size aluminium lugs, nut bolts, glands etc and comprising of the following switch gears:- Note :- PCC will be measured and paid separately under item No 20 of Sch 'A'.
(i) MCB 20 Amp, SPN 10KA rating -01 No (incommer) Make: Havells (ii) MCB 10 Amp, SP 10KA rating -02 No (Outgoing) Make: /Havells (iii) DOL Pump Starter Single Phase for 1 HP Motor - 01 Nos (iv) Digital universal meter with LED display for 1-ph Amp, Volt, Frequency and P.F Cl 0.5 Make- L&T (Cat Part No WL411021OOOO) (v) CT coil of ratio 100/5-01 Set. Make: AE (vi) Aluminium strip bus bars for 1 Phase system (vii) LED type AC 220V Phase Indicators (viii) Internal wiring of panel board with copper cable single core of sutable size
M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified & directed. Note : GI strip beyond 7.5 Mtr length from earth electrode shall be measured and paid separately.
M&L for GI Pipe light grade 40mm bore for earth strip protection in floor / road crossing / along pole complete all as specified and as directed.
M&L for GI Pipe light grade 15mm bore for earth wire protection in ground / floor / hard standing / along pole complete all as specified and as directed.
M&L for GI wire 4mm dia as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle .
Dismantling brick / concrete tiles any size etc incl existing roof treatement of any thickness complete all as specified and directed.
M&L for 40mm thick average thickness PCC 1:2:4 type B-0 using 12.5mm graded stone agg as in padding finished the surface even and smooth without using extra cement including mixing liquid water proofing compound @200 ML per 50 Kg bag of cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
M&L for preparing cement concrete / RCC roof surfaces and providing 10mm thick modified plaster in CM 1:4 cement mixed with polymer in ratio of 1:10 (1 part of polymer and 10 parts of cement) applying priming coat of epoxy primer with resin and hardener with water dilution as per manufacturer instructions, applying two coats of solvent based polyurethane liquid membrane each coat not less than 500 micron thick UV stable having SRI value greater than or equal to 105 with consumption of 0.61 Kg/Sqm (each coat) 2nd coat should be applied once 1st coat is fully dried complete all as specified and directed. Make : Asian paints / Sika / Thermax
M&L for rendering 15mm thick in cement mortar 1:4 mixed with liquid water proofing compound @200 ML per 50 Kg bag of cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for plain cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed, with grey cement and no pigment set jointed and pointed in neat cement slurry, cut and including 15mm thick screed bedding in cement mortar (1:4) complete all as specified and as directed.
M&L for Providing, cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate in coping, coving, etc as directing mixed with liquid water proofing compound @200 ML per 50 Kg bag of cement complete all as specified and directed. Note : Liquid WPC shall be measured and paid separately.
Taking up or down steel water tubing and connection of 20mm bore complete all as specified and directed.
S&F for GI tubing 20mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed.
Taking up or down steel water tubing and connection of 25mm bore complete all as specified and directed.
S&F for GI tubing 25mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed.
Dismantling water tanks of any type & capacity exc 500 Ltr but not exc 1000 Ltr complete all as specified & directed.
M&L 1000 ltr storage capacity Rotational moulded polythelene triple layer white colour water tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F Ball brass valves 20mm bore high pressure with polythene float and fly nut screwed for iron pipe of brass ferrule complete all as specified and directed.
S&F in repair 25mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 15mm bore chromium plated cast copper alloy bib taps with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 Sqmm, standed aluminium conductor, ISI marked as per IS 7098 (Part-I) : 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, fixed along pole, under road / floors / wall with use of suitable fixing clamps and passing through HDPE DWC pipe complete all as specified and directed. Make : Havells / Gloster / Polycab Note : HDPE DWC Pipe shall be measured and paid separately as supply and fixing under item No 47 of Sch 'A'.
Excavation in trenches in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of cable and getting out complete all as specified and directed.
Removing excavated soil / material to a distance not.exc. 50m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and directed.
M&L for HDPE Double wall corrugated pipe of size 63mm outer dia and 50mm inner dia confirming to IS : 14930 Part-II including necessary pipe fitting such as couplers, end caps, bend etc. laid in trenches / fixed to wall with suitable clamps for cable protection complete all as specified and directed. Make : Gemini / Stiple.
Supply and installation of 50W LED flood light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-66 proction with luminaire efficiecy of greater than 80 Lumen / Watt, Colour rendering (CRI) of ≥ 70 and co-related colour temperature (CCT) of 5700K (±500K). The luminaire should have 05 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V including all connections complete all as specified. Make of fitting : Havells or equivalent in Crompton / Bajaj / Philips
S&F of PVC insulated weather proof flat three core aluminium conductor cable of size 4 Sqmm for connections of motor / flood light including heavy duty PVC conduit pipe of size 20mm dia with suitable fixing arrangement complete all as specified and directed.
Schedule 'A' Part II Comprehensive maintenance of complete 50 KW solar power plant and its related civil & E/M works for the period of 24 months by deploying trained personal for carrying out maintenance & task given below :- (a) Weekly Task :- (i) Cleaning of PV modules minimum once in a week or as per manufacturers instructions and as directed by Engineer-in-Charge. (ii) Recording of readings / tightening of nuts / bolts, checking of electrical connections etc. once in a week or as directed by Engineer-in-Charge. (b) Periodical inspection of plant once in a month by Engineer of the solar firm installing the plant to ensure maximum output of plant. (c) The thermal imaging of PV panel should be taken once in a year for checking its health incluidng hot spots. (d) The shutdown duration of plant should be monitered, recorded and analysised. (e) All fire safety and fire fighting measures shall be ensured by the contractor during the comprehensive maintenance period irrerpective of provisions available. Note :- Repair / replacement of defective parts / civil repair works of any part / work executed in Part I will be carried out by the contractor as per defect liability and guarntee / warranty clause and nothing extra will be paid for the same.
SATYAMEGHA ENGINEERS
FRIZO INDIA PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .