Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LQualified 19 RAMESH NAGAR LALIT APARTMENT JAI BHAVANI MATA ROAD VILLAGE TOWN AMBOLI VILLAGE CITY ANDHERI WEST MUMBAI | ₹5.2 L | L1 | Qualified MSE, Category: General |
| 2 | Disqualified 281 DDA SFS FLATS SECTOR 22 DWARKA SOUTH WEST DELHI DELHI 110077 | SOUTH WEST DELHI | DELHI | 110077 | - | - | Disqualified MSE, Category: General |
Tender Value
₹4.3 L
EMD Value
Exempted
Closing Date
5 Aug 2026, 4:00 pmClosed
OCM of EMS Telecom Compound Yerawada Pune Attending
9605683
GEM/2026/B/7785935
Two Packet Bid
Supplying, replacement and fixing Potential Transformer of rating 11KV by 110V,100VA class1 in 11KV
Pune, Maharashtra
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
3 yrs
₹2 L
80%
AO CASH PGMTD BSNL MUMBAI, Maharashtra Telecom Circle, Department of Telecommunications (DOT), Bharat Sanchar Nigam Limited, Portal(BSNL), Ministry of Communications, (Ao Cash Pgmtd Bsnl Mumbai)
Exempted
Yes
5 Aug 2026
14 Jul 2026
5 Aug 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Supplying, replacement and fixing Potential Transformer of rating 11KV by 110V,100VA class1 in 11KV | Supplying, replacement and fixing Potential Transformer of rating 11KV by 110V, 100VA class1 in 11KV HT Panel including installations, connections, testing and commissioning etc complete as reqd | 1 | Each | Rahul Ravikant 411001,BSNL Electrical Division,1 st Floor, Cantonementexchange | 30 |
| 2 | Supplying, replacement and fixing Ammeter with range 0 to 20A,144 mm X 144 mm in existing panel | Supplying, replacement and fixing Ammeter with range 0 to 20A, 144 mm X 144 mm size in existing panel including installations, connections, testing and commissioning etc complete as reqd | 3 | Each | Rahul Ravikant 411001,BSNL Electrical Division,1 st Floor, Cantonementexchange | 30 |
| 3 | Supplying, replacement and fixing Voltmeter with range 0 to15 KV, 144 mm X 144 mm in existing panel | Supplying, replacement and fixing Voltmeter with range 0 to 15KV, 144 mm X 144 mm size in existing panel including installations, connections, testing and commissioning etc complete as reqd | 1 | Each | Rahul Ravikant 411001,BSNL Electrical Division,1 st Floor, Cantonementexchange | 30 |
| 4 | Supplying, replacement and fixing Indicators lamp in existing panel | Supplying, replacement and fixing LED type Indicators lamp Yellow, Red, Blue and Green in colour including testing etc complete as reqd. | 8 | Each | Rahul Ravikant 411001,BSNL Electrical Division,1 st Floor, Cantonementexchange | 30 |
| 5 | Supplying, replacement and fixing Three Vector Meter in existing panel | Supplying, replacement and fixing Trivector Meter including testing etc complete as reqd. | 1 | Set | Rahul Ravikant Cantonementexchange Dhokte 411001,BSNL Electrical Division,1 st Floor, Building, MHS Bhavan, Pune- 411001 | 30 |
| 6 | Heater rectification in 11KV HT Panel of Bieco Lawrie including testing etc complete as reqd. | Heater rectification in 11KV HT Panel of Bieco Lawrie including testing etc complete as reqd. | 6 | Each | Rahul Ravikant 411001,BSNL Electrical Division,1 st Floor, Cantonementexchange | 30 |
| 7 | Supplying, replacement and fixing Selector Switch in existing panel | Supplying, replacement and fixing Selector Switch including testing etc complete as reqd. | 3 | Each | Rahul Ravikant Cantonementexchange Dhokte 411001,BSNL Electrical Division,1 st Floor, Building, MHS Bhavan, Pune- 411001 | 30 |
| 8 | Servicing of Oil Circuit breaker in 11KV HT Panel of Bieco Lawrie make incl. testing etc as reqd. | Servicing of Oil Circuit breaker in 11KV HT Panel of Bieco Lawrie including testing etc complete as reqd. | 3 | Job | Rahul Ravikant 411001,BSNL Electrical Division,1 st Floor, Cantonementexchange | 30 |
| 9 | Servicing and Rectification of cable chattering, contact surface conditioning, Busbar link in HT | Service, maintenance and Rectification of cable chattering, contact surface conditioning and associated works for Transformer no. 2 Busbar Trunking Links in HT panel, testing commissioning as reqd. | 1 | Job | Rahul Ravikant 411001,BSNL Electrical Division,1 st Floor, Cantonementexchange | 30 |
| 10 | Supplying, replacement and fixing of Marshalling box lock for 500 KVA Indoor Transformer as reqd. | Supplying, replacement and fixing of Marshalling box lock for 500 KVA Indoor Transformer of Kirloskar make complete as reqd. | 2 | Each | Rahul Ravikant 411001,BSNL Electrical Division,1 st Floor, Cantonementexchange | 30 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9605683.pdf
GEM_BID • 0.49 MB
sow_yerwd_2026-07-14-15-44-41_b64025b501bd8c1891e8d156f82cce98.pdf
BOQ • 0.77 MB
boq_yerwd_2026-07-14-15-44-41_36bd33c11f97f94e9e2381e23d43efc3.csv
BOQ • 0.02 MB
GEM_OTHER • 1.45 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .