Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹2.4 L 301019 ALWAR RAJASTHAN 301019 | ALWAR | RAJASTHAN | 301019 | - | L2 | - | |
| 2 | L3₹1.7 LQualified Make: Aemric
Model: Aem 500 31 SECTOR 10 AMBALA HARYANA 134003 | AMBALA | HARYANA | 134003 | Make: Aemric
Model: Aem 500 | L3 | Qualified | |
| 3 | L3₹2.5 LQualified Make: piyoindia
Model: 500LPHRO HOUSE NO 13 NR POLE NO 184 KH NO 8 4 2 KOTLA VIHAR PHASE II NANGLOI NORTH WEST DELHI WEST DELHI DELHI 110041 | WEST DELHI | DELHI | 110041 | Make: piyoindia
Model: 500LPHRO | L3 | Qualified | |
| 4 | L5₹2.5 LQualified Make: Aqua prag
Model: 500lphro 0 NEAR HANUMAN MANDIR GHANS MANDI NO 2 MORAR GWALIOR MADHYA PRADESH 474006 | GWALIOR | MADHYA PRADESH | 474006 | Make: Aqua prag
Model: 500lphro | L5 | Qualified | |
| 5 | Qualified Make: EUREKA FORBES LTD(AQUAGUARD)
Model: AQUAGUARD EUREKA FORBES LTD. 115 NEAR C E T I GATE WARD NO 01 PANJREH SIDHI MADHYA PRADESH 486889 | SINGRAULI | MADHYA PRADESH | 486889 | Make: EUREKA FORBES LTD(AQUAGUARD)
Model: AQUAGUARD EUREKA FORBES LTD. | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
22 May 2018, 2:00 pmClosed
Potable water purification system Potable Water Purification System ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier electricallyoperatedrev erseosmosisbasedwate rpurifier Ultraviolet (UV) LAMP Yes yes Ultra Voilet (UV) Lamp power consumption 12 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 2 INPUT PARAMETERS Input Water TDS 3000 1000
2000
3000
4000
5000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 30-40 25-35
30-40
90-100
70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity (Litre/Hour): 500 500 Arsenic and Floride true true 1/3 removal capability Misc
warranty etc Thin-film composite membrane Yes yes High Pressure Pump Yes - Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes yes Pre Filter Vessels: Yes yes Micron Filter Yes yes Membrane Housing Yes Yes
No Auto cut Yes yes No of candles (Nos) 2 Installation Type Floor mounted Table top
Wall mounted
Floor mounted Warranty period ( for free replacement of machine 2 2
3 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2
3 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes yes Chloride & Flouride removal facility Yes with Pump yeswithpump Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 Yes - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anurag Krishna Agrawal 231222
OFFICE OF GENERAL MANAGER
DUDHICHUA AREA
PO - KHADIA DISTT - 2 30 2/3 SONEBHADRA UTTAR PRADESH 231222 EMD Required No ePBG Required No
84197
GEM/2018/B/12012
Potable water purification system
Uttar Pradesh; Sonbhadra
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Potable water purification system Potable Water Purification System ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier electricallyoperatedrev erseosmosisbasedwate rpurifier Ultraviolet (UV) LAMP Yes yes Ultra Voilet (UV) Lamp power consumption 12 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 2 INPUT PARAMETERS Input Water TDS 3000 1000 | - | - | - |
| 2000 | - | - | - |
| 3000 | - | - | - |
| 4000 | - | - | - |
| 5000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 30-40 25-35 | - | - | - |
| 30-40 | - | - | - |
| 90-100 | - | - | - |
| 70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity (Litre/Hour): 500 500 Arsenic and Floride true true 1/3 removal capability Misc | - | - | - |
| warranty etc Thin-film composite membrane Yes yes High Pressure Pump Yes - Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes yes Pre Filter Vessels: Yes yes Micron Filter Yes yes Membrane Housing Yes Yes | - | - | - |
| No Auto cut Yes yes No of candles (Nos) 2 Installation Type Floor mounted Table top | - | - | - |
| Wall mounted | - | - | - |
| Floor mounted Warranty period ( for free replacement of machine 2 2 | - | - | - |
| 3 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2 | - | - | - |
| 3 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes yes Chloride & Flouride removal facility Yes with Pump yeswithpump Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 Yes - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anurag Krishna Agrawal 231222 | - | - | - |
| OFFICE OF GENERAL MANAGER | - | - | - |
| DUDHICHUA AREA | - | - | - |
| PO - KHADIA DISTT - 2 30 2/3 SONEBHADRA UTTAR PRADESH 231222 EMD Required No ePBG Required No | - | - | - |
Exempted
22 May 2018
12 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_84197.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .