Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹7.6 L+₹56,272.55 (7.95%)Rejected-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹8.0 L+₹91,321.95 (12.9%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L3 | Rejected-AOC Rejected | |
| 4 | L4₹8.5 L+₹1.4 L (20.1%)Rejected-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L4 | Rejected-AOC Rejected | |
| 5 | L5₹9.5 L+₹2.5 L (34.9%)Rejected-AOC VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | L5 | Rejected-AOC Rejected |
Tender Value
₹9.8 L
EMD Value
₹19,680
Closing Date
29 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
REPAIR / MAINT OF STREET LIGHT FITTINGS AND CONNECTED ACCESSORIES COMPLETE FITTINGS AT TALBEHAT MIL STN UNDER AGE (I) TALBEHAT
2021_MES_475262_1
CWE/JHA/TBT/TOKEN/53 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
TALBEHAT
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) TALBEHAT
₹19,680
Yes
24 Dec 2021
15 Sept 2021
4 Nov 2021
15 Sept 2021
29 Oct 2021
4 Oct 2021
90 days
Amount
Taking down old unserviceable light fitting of any type and wattage complete all as specified and directed.
Supply, fixing and testing high performance LED Street Light fittings ENDURA PEARL PLUS luminaries of 72Watts, energy saving and environment friendly long life pressure die -cast aluminum hosing high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP-66 Protection and impact resistance of IK07 with 10KV Built-in-Surge Protection Device suitable for pole dia 54 mm complete all as specified and directed.
Supply, fixing and testing high performance LED Street Light fittings ENDURA PEARL PLUS luminaries of 92 Watts, energy saving and environment friendly long life pressure die -cast aluminum hosing high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP-66 Protection and impact resistance of IK07 with 10KV Built-in-Surge Protection Device suitable for pole dia 54 mm complete all as specified and directed.
Supply, fixing and testing in replacement High performance LED Flood light fitting/luminaries of 170 watt power consumption, made out of die cast aluminum housing, hermitically sealed to achieve IP 66 ingress protection, optical compartment shall be provided with heat resistant toughened glass, while control gear shall be provided with die cast aluminum cover for safety. The LED's used in street light should be ANSI standard rated LED with CCT of with useful L70 life of 50000 hours including multistage current constant voltage topology driver suitable to operate in input voltage range of 150V to 270V (nominal rated voltage-240V) with minimum 3KV surge protection. Power factor greater than 0.90 and total harmonic distortion (THD) of less than 10% should be integral to the luminaries complete all as specified and directed.
Supply and fixing 1.5 sqmm solid aluminum single core PVC cable for street lights from ACSR conductor to PVC connector complete all as specified and directed.
Supply and fixing single phase PVC connecter 5-10 amps with brass screw both side complete all as specified and directed.
Supply and fixing LED driver for 70 watt street lights complete all as specified and directed.
Supply and fixing LED driver for 90 watt street lights complete all as specified and directed.
Supply and fixing LED driver for 150 flood lights complete all as specified and directed.
Supply and fixing nature switch contactor three phase 4 pole 65 Amp coil voltage 440 volts make Havells cat No CN 565 complete all as specified and directed.
Supply and fixing nature switch contactor single phase 2 pole coil voltage 230 volts complete all as specified and directed.
Supply and fixing MCB TPN 63 Amp 415 V, 10KA 'B' series complete all as specified and directed. Make : Havells
Supply and fixing in replacement, street light bracket on RCC/Steel tubular pole made out of 40 mm dia bore G I Pipe light grade of length not less than 1.2 mtr bend to required shape for holding the fitting with providing the clamp nut, bolt and washer etc of required size and 02 nos mild steel supporting clamps shall be made out of flat iron of size 40mmx5 mm of requisite length mild steel work shall be painted with two coat of aluminum paint over a coat of red oxide primer complete all as specified and directed.
S&F LED post top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaries with high power LEDs as light source and RUBY (CLEAR)-IP-65 protection of 40 watt, 6000K, 240 volt, 50 Hz. complete all as specified and directed.
Taking down/dismantling, Re-installed and shifting (appx 1 KM) of High mast light 15mtr long suitable for 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia and double drum winch with luminaries mounting arm, pulley assembly, aviation obstruction light, lightening arrester spike, including as per existing GI nuts and bolts qty 08 Nos, complete all as per height and manufacturer instruction. Note: The follwing items paid in seperate items. (i) The excavation of foundation will be 2500mmx2500mmx2500mm deep. (ii) PCC in foudation will be 2500mmx2500mmx100mm. (iii) RCC in foudation will be 900mmx900mmx2400mm deep
Excavation in trenches not exceeding 1.5mtrs wide & not exceeding 1.5mtr in depth as in soft/ loose soil & getting out complete all as specified and directed.
Returning , filling in spreading, leveling, watering & well Ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated material not exc 50mtr & deposited where directed at a level not exc 1.5mtr above the starting point complete all as specified and directed.
M&L for bricks common burnt sub class B designation for protection of cable complete all as specified and directed.
M&L for spreading clean dry sand cushioning to underground cable in layers of 23 cm (8 cm deep before laying of cable and 15cm deep over the cable) after laying the cable in trenches complete all as specified and directed. Note: - Only punned thickness will be considered for payment.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Reinforced Cement concrete 1:1.5:3 type A-2 type using 40 mm graded stone aggregate for foundations of poles, struts & stay assembly etc complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in cooping of poles etc including fair finishing the exposed surface even and smooth with out using extra cement and necessary form work complete all as specified and directed.
M&L in replacement of 10 sqmm 2 core XLPE insulated heavy duty electric cables with Stranded alluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of alluminium lugs. For the following sizes.
Supply and laying or fixing in replacement GI tubes light grade 40 mm dia, on place of rusted GI pipe in support of cables, on pole/wall/laid in floor/in trenches including taking down complete all as specified and directed.
M&L for Earthling complete with galvanized earth plate electrode 600x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanized earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust common salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-0 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe complete all as spfd and as directed. connected to earthing point (Main Distribution Board) complete all as specified and directed.
M/S Kharya Associates
HARNAM SINGH ANIL SINGH
M/S SHIVA TRADERS
M/S A.R BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .