Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.4 L+₹6.1 L (42.8%)Rejected-Finance 2 8 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹20.9 L+₹6.6 L (46.4%)Rejected-Finance | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹21.4 L+₹7.1 L (49.8%)Rejected-Finance | L4 | Rejected-Finance BIDDER NOT LOWEST | |
| 5 | L5₹21.7 L+₹7.4 L (51.8%)Rejected-Finance | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
17 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
COMPREHENSIVE MAINTENANCE OF EM NATURE OF WORKS IN OTMS AGE B R II III UNDER GE WEST DELHI CANTT 10
2022_MES_520777_1
GE/DW-56/2022-23
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹99,000
17 Oct 2022
22 Aug 2022
19 Sept 2022
23 Aug 2022
17 Sept 2022
5 Sept 2022
Amount
Checking and attending complaints by experience tradesman means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES daily except national holidays complete all as specified and directed. Note: 1. This item covers cost of labour for attending complaint comprising taking down of old material and fixing of item issued by the Deptt. 2. Complaints noted'' NO Light,Short circuit,Sparking,Burning etc issues in electric circuits shall be attended imediately up to 2200 hrs on same day without fail, failing which recovery of Rs. 500.00 per complaint shall be effected from the contractor's dues. 3. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimbles, electric tape,screws,nut & bolts,washers,fan holding bushes, etc shall deemed to be included in the quoted rate of this item. 4.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, if it is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding. 5. Contracror shall arrange suitable T&P incl necessary from work and scaffolding and safety measures to make it functional complete all as specified and directed. 6. Contractor or his rep will report daily at complaint cell at AGE B/R-II & AGE B/R-III for collection of complaints from the concerned JE in charge. 7 Job slip as per sample shall be provided by the contractor free of cost. 8. The contractor is advised to inspect site and to note that he has to deploy daily (Three Electrician & One Helper) men power to collect the complaints from complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account. 9.All Items Required to replace such as switches,sockets,call bells,Bell push,Capacitors,Plug Tops,Metal clad sockets,ceiling roses,light fittings,ceiling light fittings,fan regulators,MCBs,MCB DB's,MCCB's,VTPN DBs ,security lights,all materials except fixing accessories etc any capacity shall be issued by the department free for fixing and labour shall be paid unde respect items of this BOQ 10.Item required to replace in repairs based on Day to Day complaints by the users as when as required as site. 11.Old unserviceable material obtained from site shall be deposited to MES store Yard. 12. Contractor provided two electrician and two helper at NCL and AGE B/R-II Complaint cell.
S&F in Replacement of MS down rod 300 mm for fixing of ceiling fan all as specified and directed
S&F in Replacement of Ceiling fan blade 1200mm sweep for fixing of ceiling fan all as specified and directed.
S&F hot press moulded SMC meter box of inside dimensions 250x150x155mm with hinged doors fixed on new plywood to wall size of 500x450x10mm complete all as specified and directed. Make: Sintex or equivalent
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power) complete (fittings such as switches, ceiling roses, holders, sockets, light fittings) and deposit the same to MES Store and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed.
M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed conduit/open PVC rigid comduit, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing moduler switches/sockets etc with cover plate/3mm thick plastic laminated sheet for one light / fan / exhaust fan / circulator fan / bell/ buzzer controlled by one 1-way switch complete all as specified and directed.
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
(d) One two way point controlled by 2 way switch 5 amps.
All as per srl item no. 6.01(a) but with 3x2.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) for 15 Amp power point.
M&L for concealed point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in and including PVC concealed conduit ISI marked of suitable size medium grade with PVC conduit fittings such as tees, bends, elbow, reducers including cutting, chasing and making good to the disturbed surface, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing moduler switches/sockets etc with cover plate/3mm thick plastic laminated sheet for one light / fan / exhaust fan / circulator fan / bell/ buzzer controlled by one 1-way switch complete all as specified and directed .
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
(d) One two way point controlled by 2 way switch 5 amps.
All as per item No. 12 (a) here in before but with 3x2.5 Sqmm and (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) for 15 Amp power point.complete all as specified and directed
S&F of socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S&F of bell push flush type 5 amps complete all as specified and directed.
S&F of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S&F of socket outlet multi 2 in 1, 5 and 15 Amps complete all as specified and directed.
S & F repair ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections.complete all as specified and directed.
S&F of switch piano flush button type 5 amps single pole two way complete all as specified and directed.
S&F of bell complete all as specified and directed.
Supply, laying and drawing 02 x 6.00 sqmm + 1 x 6.0 sqmm in and including 20 mm dia concealed PVC rigid conduits including cutting chases for laying conduit making good as per existing surfaces or as directed on walls of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection and taking out old submain wiring all as specified and directed.
M&L for taking down & refixing and rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) including taking out old wind copper wire with appropriate gauge and quantity, both sides of rewinding covered with high quality varnish complete including replacement of ball bearing as requirment of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep complete all as specified and directed. Note- Each Qty under this item must be repair and fixed within 5 days commencing from date and time of notifying the complaint failing which a penalty @300 per complaint per day shall be levied /imposed and recovery sall be effected from contractor's dues.
M&L for taking down & refixing and rewinding of exhaust fan of 300mm sweep of any type & make complete with super enamelled copper wire (HTP) including taking out old wind copper wire with appropriate gauge & qunatity, both sides of rewinding locked with high quantity varnish complete inclusion of ball bearing of SKF/NBC make and provisions of new nuts pin all as specified & directed. Note- Each Qty under this item must be repair and fixed within 5 days commencing from date and time of notifying the complaint failing which a penalty @300 per complaint per day shall be levied /imposed and recovery sall be effected from contractor's dues.
M&L for taking down & refixing and replacement of motor & blade of exhaust fan of 450 mm sweep of any type & make complete with super enamelled copper wire (HTP) provisions of new nuts pin all as specified & directed.
M&L for taking down & refixing and replacement of motor & blade of exhaust fan of 300 mm sweep of any type & make complete with super enamelled copper wire (HTP) provisions of new nuts pin all as specified & directed.
M&L for taking down & refixing and replacement of motor & blade of Fresh air fan 250/300 mm sweep of any type & make complete with super enamelled copper wire (HTP) provisions of new nuts pin all as specified & directed.
M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
M&L in repair lower shutter of exhaust fan suitable for 300/450 mm size at the height from 3 mtr to 30 mtr height making good surface of distubed area complete all as specified & directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
S& F in repair copper heating element 1500 / 2000 watt embedded copper, sheathed tubular with theremostat casing cap triangular type as per site requriement complete all as specified and directed.
S&F Capillary / Normal thermostat suitable to work water temperature 30° to 75° C electric cut up for any type of water heater as per site requirement given by engineer -in- charge complete all as specified and directed.
S&F in Replacement of copper flange assembly suitable for 25 ltrs capacity water storage heater (geyser) with nut & bolt as per site requirement complete all as specified and directed.
S&F outer shell of geyser with collar made out of gauge of suitable for geyser of capacity 25 ltrs as per site requirement complete all as specified and directed.
S & F in Repair inner shell of Steel body suitable for geyser of capacity 25 ltr complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, burieddirectly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-1 2009, connected to earthing test point, earth lead protected by medium grade 15 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 B-1 ( including excavation and earth work, disposal of surplus soil to a distance not exc. 50 Mtrs) all as specified and shown on plate No 5 of SSR – Part I 1991. Note:-(a). PCC pit shall be provided at list 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipe and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (b). RCC pit cover shall be of pre-cast RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4 Kg/ Sq m in lieu of cast iron cover all as specified or indicated including testing on completion all as specified and directed.
S&F in repair of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.2 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed.Make: NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 125, 4 pole MCCB and ELM as incommer and MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in of MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
S&F of SPN MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed.
Supply laing testing and commissioning of XLPE insulated armoured heavy duty electric cable with aluminumstranded copper conductor 1100 volt grade crossectional area 16 Sqmm 2 core LT cable completee all as specified directed
Deduct Credit: for demolished/dismantled material of (-) Rs 311420.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
jain associates
SETHI ENTERPRISES
GAUTAM ELECTRIC WORKS
NAVDURGA BUILDERS
M/s Krishna Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .