EE PD PWD B and R Rewari
EE PD PWD B and R Rewari
Construction of Distt. Head Qtr. Office Building for Excise and Taxation Deptt. in sector - 19 at Rewari in Rewari Distt.
2020_HRY_154763_1
Const. of Head Qtr. office Building for Excise
Open Tender
Civil Works - Buildings
635 days
Rewari
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
₹31.1 L
SE Rewari Circle PDW B and R Rewari
4 Feb 2021
1 Jan 2021
22 Jan 2021
1 Jan 2021
21 Jan 2021
1 Jan 2021
7 Jan 2021
Amount
Earth Filling under floors with surplus soil excavated from foundation and taken only from outside the building plinth, in 15 cm layers including ramming watering and consolidating lead up to 30 meters. Subject to condition soil Is non plastic. [HSR 6.13(a)].
Clearing jungle including uprooting of rank vegetation, grass brush wood, trees and saplings of girth upto 30 cm measured at a heigh of 1 metre above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. (HSR 6.26).
Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness upto 6" (Six inches) for passing drain pipe 6" (six inches) internal diameter and repairing the hole after insertion of drain pipe etc. including finishing complete so as to make it lead proof. [HSR 8.39 (a)].
Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness upto 4" (four inches) for passing drain pipe 4" (four inches) internal diameter and repairing the hole after insertion of drain pipe etc. including finishing complete so as to make it lead proof. [HSR 8.39 (b)].
Centering & shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. inclination not exeding 25 degree with horizontal. (HSR 9.1)
Centring and Shuttering for sides and soffits of beams hunchings, griders bressumers and lintels. (HSR 9.7).
Centring and Shuttering for columns (square or rectangular or polygonal in plan). (HSR 9.9).
Centring and Shuttering for corbel, parapets, fascias and other similar items, including luding edges. (HSR 9.11).
Shuttering for faces of concrete foundation and foundation beams (Vertical or Battering). (HSR 9.13).
Cement concrete 1:8:16 with stone aggregate 40 mm Nominal sie in foundation and plinth. (HSR 10.28)
Cement concrete 1:4:8 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.38)
Cement Concrete 1:2:4 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.41).
Cement Concrete 1:1½:3 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.42).
Cement Concrete 1:2:4 with stone aggregate 20 mm nominal size if first storey upto 4 metres above plinth level. (HSR 10.59).
Providing and laying in position machine batched and machine mixed design mixed M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as direction of Engineer-in-charge in foundation and plinth. (Note:- Cement content considered in this item is @ 330 Kg/cum). (HSR 10.66)
Providing and laying in position machine batched and machine mixed design mixed M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as direction of Engineer-in-charge in first storey upto 4 metres above plinth level. (Note:- Cement content considered in this item is @ 330 Kg/cum). (HSR 10.73). Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
Precast cement concrete 1:1½:3 with stone aggregate 20 mm nominal size in Kerbs and the like itmes, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete at the ground level or in first storey. [HSR. 10.77 + 10.95 (a)].
Precast Factory Manufactured cement concrete 1:1½:3 with stone aggregate 20 mm nominal size in Tiles and Chanels the like itmes, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete at the ground level or in first storey. [HSR. 10.78 + 10.95 (a)].
Providing and laying 80 mm thick ISI marked internlocing paver paver blocks conforming to IS 15658:2006 /IRC:SP:63-2004 of all Shapes and colours in design mix cement M-40 over a bed of 30 mm thick fine sand complete in all respect. (HSR 10.159). (Note:- Reputed make Paver Block Only ISI marked will be used as approved by Engineer-in-charge).
First class brick work laid in cement sand mortar 1:6 in foundation plinth. (HSR 11.2)
First class brick work laid in cement sand mortar 1:4 in foundation plinth. (HSR 11.4)
First class brick work laid in cement sand mortar 1:6 in 1st storey upto 4 metre above plinth level. (HSR 11.7) Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
First class brick work laid in cement sand mortar 1:4 in 1st storey upto 4 metre above plinth level. (HSR 11.9)
11.43 cm thick brick wall laid in cement sand mortar 1:4 in spuer-structure. [HSR 11.48 (a)]. Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Masonry work sing flyash-lime based brick (IS: 12894-2002) laid in cement sand mortar 1:6 in super structure. (HSR 11.102) Note:- The Agency to whom the work is allotted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
Providing & laying Autoclaved Aerated (cellular) concerete light weight blocks (As per IS :2185 Part -3) having density of 550 to 650 kg/m3 and compressive strength of 4.0 N/mm2; masonery in non load bearing walls using more than 100 mm thick AAC blocks complete in all respects. (ii) with Polymer modified adhesive of reputed make as approved by Engineer-in-charge in superstructure. (HSR 11.105). Note:- The Agency to whom the work is allotted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
Terracing consisting of tiles 22.86 cm x 11.43 Cm x 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13). Second Storey
Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16. (HSR 13.50)
Supplying & fixing in position G.I. pipe class 'B' spouts in chajjas and cantilevers. (e) 50mm i/d G.I. pipe. [HSR 13.55 (e)].
Bottom khurra on ground 1.2 m x 0.6m consisting of brick on edge laid in cment mortar 1:3 over 75mm c:c 1:8:16 including 12mm thick cement plaster 1:3. (HSR 13.57)
Cement Concrete 1:2:4 gola 10cm x 10cm quadrant along junction of roof with parapet wall finished smooth, where specified. (HSR 13.64).
Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (Note:- Reputed make PVC Pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.89]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (a) 100 mm dia PVC pipe 6 kg. pressure.
(b) 150 mm dia PVC pipe 6 kg. pressure.
Providing and fixing PVC Bend ISI Mark. (Note:- Reputed make PVC Bend such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.90]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (a) 100 mm dia PVC Bend.
(b) 150 mm dia PVC Bend.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. (with or without grooves). (13.92).
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (a) GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. [HSR 13.98 (a)].
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : (a) GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (HSR 13.100 (a)].
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling. (HSR 14.1)
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. (HSR 14.4) First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
Conglomerate floor 40 mm thick Cement Concrete topping 1:2:4. (HSR 14.9)
Precast chequered tiles of 20 mm thickness In ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings. (Note:- Reputed make Tile Only ISI marked will be used as approved by Engineer-in-charge). [HSR 14.45+Note]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
Precast Terrazzo tiles of 20 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry, between joints and over the base in floors, treads of steps and landings including rubbing and polishing. (b) in 50% white & 50% grey cement. (Note:- Reputed make Tile Only ISI marked will be used as approved by Engineer-in-charge). (HSR 14.44 (b)]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
Precast terrazzo tile of 12.5 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 10 mm thick cement coarse sand plaster 1:3 and jointed with neat cement slurry in skirting, dado and risers of steps, including rubbing and polishing complete. (b) in 50% white and 50% grey cement. (Note:- Reputed make Tile Only ISI marked will be used as approved by Engineer-in-charge). [HSR 14.47 (b)]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
Fixing & laying of Marble stone flooring 17 mm and above thick slab including matching grains of marble laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. (Excluding the cost of Marble, Marble will be supplied by the Department). (HSR 14.49). First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Kotah stone flooring minimum 25 mm thick in any pattern as specified over 12 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
Extra for nosing in treads of steps of Kotah stone slab. (HSR 14.65)
Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. (HSR 14.66). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
Providing and fixing glass strips 5.5 mm thick 40 mm wide in floors. (HSR 14.80)
Providing & fixing ceramic tiles/anti skid tiles of size 400mm x 400mm or above size of approved make in flooring, laid in any pattern as specified over base of 20 mm thickcement coarse sandmortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. Not : Tile shall be of premium quality (first quality) of reputed manufacturer like:- NITCO, KAJARIA, RAK, SOMANI, JHONSONS, ORIENTBELL, SIMPOLO shall be used as approved by Engineer-in-charge. (HSR 14.91). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing & Fixing Ist quality Ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manu-facturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-In-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including ointing in white cement mixed with pigment of matching shades complete. (b) Size of ceramic Glazed tiles 300 x 450 mm of reputed manufacturer like:- RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO shall be used as approved by Engineer-in-charge. [HSR 14.92(b)]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Laying and fixing Granite stone in all shade,15mm to 18mm thick in skirting/dados, risers of steps, pillars, wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortor 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite including labour for fixing cramps pins and dowels etc. (Excluding the cost of Granite, Granite will be supplied by the Department). (HSR 14.95). Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Laying and fixing Granite stone in all shades 15 mm to 18 mm thick in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite stone. (Excluding the cost of Granite, Granite will be supplied by the Department). (HSR 14.96). First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing edge moulding to 17-20 mm thick Granite stone counters, Vanities etc., including machine polished to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (ii) Double Moulding. (HSR 14.98).
Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting, dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. (HSR 14.98). First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing and laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. (HSR 14.99) First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
12 mm thick cement Plaster & rendering on plaster 1 mm thick. (HSR 15.4+15.75)
12 mm Thick Cement Plaster 1:4 on the rough side of single or half brick wall. (HSR 15.5).
12mm thick cement plaster on walls (1:6). (HSR 15.7). Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
15mm Thick Cement Plaster 1:4 on the rough side of single or half brick wall. (HSR 15.10).
15mm Thick Cement Plaster 1:6 on the rough side of single or half brick wall. (HSR 15.12). Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
10mm thick cement plaster 1:4 under side of ceiling. (HSR 15.52). Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Seventh Storey
20 mm thick cement plaster vertical damp proof coarse 1:3 with two coats of bitumen at 1.65 Kg. per sqm. Laid hot & sanded (HSR 15.77) (a) Vertical
Preparation of ply wood surface for painting inlcuding sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1) Through Rate
Providing and Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.2). Through Rate
Providing and Applying Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3). Through Rate
Providing and Applying priming coat with metal primer on new steel or iron work including preparation of surface. Painting on mettalic Surfaces etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.9). Through Rate
Providing and Applying Painting two coats excluding priming coat with ready mixed paint for matelic sufraces in all shades on new steel or iron work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.17). Through Rate
Providing and Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surface. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.25). (Through Rate)
Providing and Applying Painting two coats with ready-mixed exterior paint in all shades on newly plastered or concrete surface of walls. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.26). (Through Rate)
Providing and Applying White Washing. (Three Coats). (HSR 16.48). Through Rate
Providing and Applying Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.58). Through Rate
Providing and Applying Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). [HSR 16.79 (b)]. Through Rate
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81). Through Rate
Providing & fixing 150 mm hasps and staples with necessary screws, etc. complete Aluminium. (Powder coated fittings will be supplied by the deptt. Instead of Aluminium fittings.) [HSR 17.78 (b)].
Providing and fixing helical door spring 150 mm (superior quality), including necessary screws, complete- (b) iron. [HSR 17.79 (b)].
Supplying and fixing hydraulic door closer I.S.I mark, with necessary screws etc. complete (b) I.S.I designation no. II (size of door 701 mm to 850 mm) [HSR 17.82(b)].
Providing and fixing 50 mm cup board or ward robe knob- (b) aluminium. [HSR 17.84 (b)].
Providing and fixing 0.50 mm thick aluminium sheet, including cost of necessary screws, etc. complete. (HSR 17.87).
Factory manufactured panelled door or glazed windows shutters of commercial hard wood such as Hollock, Champ, Chikrassy & Chaplash only. (non coniferous timber other teak, confirming to I.S. pecificationNo. 1003, Kiln seasoned) with 100mm wide vertical styles, 150mm wide lock rail 200 mm wide bottom rail, and 100mm wide other rails, with panels of 15mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges, screw, chock/cleats, stops nails etc. complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position). (a) 30 mm thick. [HSR 17.90 (a) - Note 1 under 17.18].
Factory manufactured wire gauze door and window shutters of commercial hard wood such as Hollock, Champ, Chikrassy & Chaplash only. (non-coniferous timber other teak conforming to I.S. specification No. 1003, kiln seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail 200 mm wide bottom rail, and wire gauze of 140 G or 120 G designation including cost of iron hinges, screws, chock/cleats, stops nails etc., complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position. (Styles and rails of windows shutter shall be 75 mm wide. (i) 30 mm thick. [HSR 17.92 (i) - Note 1 under 17.18]
Factory manufactured Solid Flush Door Shutter, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hotpressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position. (Note:- reputed make such as Duro, Green, Kitply will be used as approved by Engineer-in-charge). HSR 17.93 (a) - Note 1 under 17.18]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (i) 25 mm thick.
(iii) 35 mm thick.
Providing and fixing Aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z. sections and other sections of approved make conforming to IS;733 and IS;1285 fixed with raw plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. aluminum sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling C.P brass/stainless steel screws. All complete. Fixed portion (Anodized Aluminum transparent or dyed to required shade according shade according to IS;1868, minimum anodic coating of grade AC 15). (HSR 17.95+Note (ii)). Hindalco, Jindal make.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawel plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. Aluminium sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling C.P brass/stainless steel screws, etc. complete shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required including aluminium fitting. (HSR 17.96+Note (ii)].
Providing and fixing 12 mm thick preleminated paticle board flat pressed three layer or graded wood particle board conforming to IS;12823 grade I type II in paneling fixed in aluminium doors. Windows shutters and partition frames with c.p brass / stainlees steel screws etc. complete (b) Pre-laminated particle board with decorative lamination on both sides. [HSR 17.97 (b)].
Providing and fixing glazing aluminium door, windows ventilator shutter and partitions etc. with PVC/neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basis items.) (b) with float glass panes of 5.00 mm thickness. [HSR 17.98 (b)].
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS 6315 marked for door including cost of cutting floors as required embedding in floors and cover plates with brass pivot and single piece M.S sheet outer box. (a) with stainless steel cover plate. [HSR 17.99 (a)].
Providing aluminium Jali of thickness 7mm thick with openings 75mm x 75mm of including anodizing and fixing frame with cost of screws etc complete (HSR 17.100)
Providing fixing Aluminum round shape handic of cuter dia 100 mm with screws etc. complete. (I) Anodized (AC-15) Aluminum. [HSR 17.102 (i)].
Providing & fixing of casement fixed windows made from multy chambered UPVC profile of 56 to 68 mm width in natural from stabilized for heat ,light,impact & UV radiation .The UPVC profilees of designed thickness . All openable sashes shall be having weather seal fitted in continuos lengths made from Bubble EPDM Rubber & side hung/top hung with upto 90 degree opening friction stays of SS 304 with provision of multy point locking system made from Espang rods .all handle shall be made from Die Cast Zinc alloy ( Model : ESPANG) BS -1004 A in white finish with suitable locking arrangement . The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speed uopt 180 Km/hr . the shoot bolts in windows shall be rust proof metalic coated steel. The window frames shall be fixed in masonery wall/RCC with necessary fastners, nuts, bolts washers, caps, silicon sealent etc. complete. (HSR 17.103) (a) Frame Work
(b) Openable Shutter
Providing and fixing double glazing consisting of glass 6mm (toughened) and annealed plain glass i/c 12mm air gap including cost of structural silicon sealant & weather sealant (DC795/DC789) & double sided acrylic foam tape in structural glazing works upto 4th storey. The outer glass shall have U value < 1.8 solar factor < 0.35 Light transmission > 49% of make Blue essence EH 46/35 Ecosense essence AIS or equivalent as per approval. (HSR 17.104)
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12).
Supplying, hoisting and placing in position tubular trusses including runners, purlins, consisting of steel tubes conforming to I.S. specifications of tested quality duly welded with fillet welds 6 mm thick through-out including wind bracing. Open end of pipe sealed with 3 mm thick plate including the cost of nuts and bolts where bolts connections are specified at flange joints including one coat of ready mixed red oxide zink cromate primer of approved quality assembling and fixed in position complete in all respect. (HSR 18.14)
Supplying and fixing rolling shutters, of approved make, M.S. laths, interlocked together through their entire length, and jointed together, t the end, by end locks mounted on specially designed pipe shaft, with brackets, side guides 27.5 cm long wire spring grade no. 2, and arragnement for inside and outside locking, with push and pull opreation complete, including top cover 0.80 mm thick (payment is to be made for the exact size of opening where rolling shutter to be fixed):. (b) with 80 mm X 1.25 mm M.S. Laths. [HSR 18.18 (b)].
Extra for providing mechanical device, chain and crank operation for operating rolling shutters, exceeding 11.20 sqm in areas of the rolling shutter. (HSR 18.19).
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including Straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths /storeys/ basements etc. (Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement). (HSR 18.22).
Supplying and fixing Glass panes including special metal sash putty of approved make. (b) glass panes 4 mm thic, exceeding 40 sq. dm areas. [HSR 18.30 (b)].
Pressed steel sheet frames (chowkhats) consisting of 2mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete. [HSR 18.34]. (a) door and window frame Size of 89 mm x 59 mm with 40 mm wide signel rebate.
(c) door and window frame size 127 mm x 50 mm with 40 mm wide double rebate.
Preparation of sub grade including trenching rough dressing of soil, final dressing of earth, to given levels and camber, watering, rolling with road roller and compacting the bed (HSR 24.1)
DSR ITEMS Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing. (i) 30 mm thick plain PVC door shutters. (DSR 9.120.1)
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). (DSR 9.147A) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm)..(DSR 9.147A.5)
Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm). (DSR 9.147A.6)
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR 10.28).
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. (ii) 2 mm thick. [DSR 12.47.2)
Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building. (DSR 12.34).
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. (DSR 12.55).
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. (DSR 13.52). (i) On Steel Work/Metallic
(ii) On Concrete Work
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). (DSR 21.18)
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600. (iii) Upto 20 mm depth and 20 mm width. (DSR 21.19.3).
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (i) Using rough kota stone. (DSR 22.1.1).
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charg. (i) Using rough Kota stone. [DSR 22.2.1].
Providing and supplying Glass Panels comprising of 6 mm thick heat strengthened/toughened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in-Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. (DSR 25.6).
Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorptions <1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer- in-Charge. (DSR 26.7).
NS ITEMS Providing & Fixing Vitrified Tiles 600 x 600 mm of approved make in flooring laid in any pattern as specified over base of 20 mm thick cement coarse sand morter 1:3 and joint will be 4 mm wide instead of zero joint by using spacers to ensure uniformity of joint duly filled with epoxy grout minimum depth upto the thickness of tile of reputed make such as pidilite (T-13 Roff), Mapaie, Laticrete, Ardex Endura, as approved by Engineer-in-charge. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like: RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO. (Double charged tiles shall be used as approved by Engineer in charge. (NS). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing & Fixing Vitrified Tiles 600 x 600 mm of approved make skirting/dados, pillars, wall facing, laid in any pattern as specified over base of 20 mm thick cement coarse sand morter 1:3 and joint will be 4 mm wide instead of zero joint by using spacers to ensure uniformity of joint duly filled with epoxy grout minimum depth upto the thickness of tile of reputed make such as pidilite (T-13 Roff), Mapaie, Laticrete, Ardex Endura, as approved by Engineer-in-charge. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like: RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO. (Double charged tiles shall be used as approved by Engineer in charge. (NS). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing and Laying Pre-polished Granite stone 17 mm & above (Colors like :- S-White, Steel Grey, Tan Brown, Marigold, crystal Blue, Rajasthan Black, Copper Silk) in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite stone. (NS). First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing and Laying Pre-polished Granite stone 17 mm & above Like :- S-White, Steel Grey, Tan Brown, Marigold, crystal Blue, Rajasthan Black, Copper Silk in skirting/dados, risers of steps, pillars, wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortor 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite including labour for fixing cramps pins and dowels etc. (NS). Basement
First Storey
Second Storey
Third Storey
Fourth Storey
Fifth Storey
Sixth Storey
Providing, Laying & Fixing of GRC tiles of approved shade over 12 mm thick cement mortar 1:4 for exposed outer surface for all heights including the cost of scaffolding complete in all respect for all Heights. (Note:- Reputed make Tile such as Unistone, NTC, DALAL shall be used as approved by Engineer-in-charge. (NS)
Providing and fixing structural glazing with 6 mm thick antelio heat resistant glass (toughened reflactive colored glass) (make: MODI, SAINTGLOBAIN, AIS) over frame of aluminium extruded tubular section and joints duly filled with silicon sealer (Exterior and Interior Grade) and gasket complete.The rate to be inclusive of cost of material such as cleats, sleeves, screws, silicon sealant, gasket of superior quality etc. necessary for fabrication of extruded aluminium frame work, in all respects to the entire the satisfaction of the Engineer in Charge. (Make of all the constituents like sealant, gasket etc. shall be got approved from Enginner-in-Charge before application (Excluding cost of Aluminium) (NS). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (Excluding cost of Aluminium) (NS).
Providing and applying of Texture painting (mettalic) for all heights (Paint consumption 3.28 Ltrs./10 sqm & exterior primer consumption @ 2.2kg/10 sqm) approved by architect of approved brand on new surface of external walls including preparation of surface, priming coat of approved brand as per manufacturer specifications and directions of Engineer-in-charge. (Make:- ICOS, Nerolac, Heritage). (NS)
Providing and laying Trimix flooring consisting 1:1:2 M-25 150 mm thick laid over base of 100 mm thick cement concrete 1:4:8 including dewatering and vibrating with double beam vibrator including cutting of the panells complete in all respects. (NS)
Laying and fixing Tactile of any size of approved make in floors laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles including cost of all material except tiles. (Tactile Shall be supplied by the Department). (NS).
Providing ISI marked aluminium Tower Botls with nuts & screws etc complete. (NS) Size 100 mm x 12 mm
Size 150 mm x 12 mm
Size 200 mm x 12 mm
Providing ISI marked aluminium Sliding Door Botls with nuts & screws etc complete. (NS) Size 250 mm x 16 mm
Size 300 mm x 16 mm
Providing ISI marked aluminium Door Handles with nuts & screws etc complete. (NS) 75 mm x 30 mm x 10 mm.
100 mm x 30 mm x 10 mm.
125 mm x 35 mm x 12 mm.
150 mm x 35 mm x 12 mm.
Providing ISI marked aluminium butt hinges with nuts & screws etc complete. (NS) Size 100 mm x 31.75 mm x 11 mm
Size 125 mm x 31.75 mm x 11 mm
Earth work in Excavation by mechanical/manual means in basement including its foundation for all widths up to a depth of 5.0 Mtrs. and all type of soil/Rock/boulder/kankar etc. as encountered at site including disposal of excavated material for all lead & lift. The Excavated material shall be the Property of department. This Material shall be disposed as per direction of the department. The permission required from mining department shall be obtaining by the contractor at his cost. Part of the excavated material shall be used for refilling as per direction of the Department. (NS)
Earth work with Tibba Sand in Road & Parking taken from outside of campus area with all lead and lift including loading, unloading, laid in 15 cm layer including ramming, watering, consolidating, compaction, and compensation of earth etc., complete in all respect as per the direction of engineer in charge. (For any lead and lift). [NS].
Providing and laying 200 mm thick granular sub base consisting of drainage layer confirming to Table 400.1 Grading –VI of MORT&H 5th edition, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve desired density complete as per clause No.401 of MORT&H specifications for road & bridge (5th Revision) of 2013. (NS).
Providing & laying 75mm thick (Compacted) stone metal (G-II) 53mm to 22.4mm gauge wearing coat to waterbound macadam in layer of 75 mm each using screening type ‘B’ compacting with 3 wheeled steel roller/vibratory roller to achieve the desire density including lighting, guarding barricading and maintenance of diversion etc. as per clause No.404 of MoRT&H specifications for road & bridge (5th Revision) of 2013 as per drawing and design directed by the Engineer complete in all respects. (NS).
Providing and laying 75 mm thick Dry Lean Cement Concrete Sub-Base Construction of dry lean Cement Concrete M-10 sub base over a prepared sub grade with coarse and fine aggregate conforming to IS 383 the size if course aggregate not exceeding 25mm aggregate cement ratio not to be exceed 15:1 aggregate gradation after blending to be as per table 60-1 of MoRT&H specification (5th edition) cement content not to be less than 150 kg/ cum optimum moisture content to be determined during trail length construction, concrete strength not to be less than as 10 MPA at 7 days mixed in the batching plant transported to site laid with a paver compacting with 5-10 tonne vibratory roller, finishing and curing as per clause 601 of MoRT&H specification (5th edition) 2013. Note:- If cement contents are required more than 150 Kg. per cum to achieve strength it will be incidental to work and nothing extra shall be payable on this account.
Excavation of trenches in streets, lanes or in open areas for storm sewer, sewers running by gravity and manholes to full depths as shown in drawings including shoring, timbering of poling boards, frame system type, dressing to correct sections and dimensions, according to templates and levels, dewatering, provision for diversion of traffic, cutting trees and bushes, etc. night signals profiles, pegs, sight rails, boning rods, crossing over trenches for access to the houses, watching fencing etc. fixing and maintenance of caution board refilling of trenches, watering of refill, in 15 cm layers ramming and restoration of unmetalled or unpaved surface to original condition and removal of surplus soil, from site of work, upto a lead of 1 Km in oridnary soil. (a) for depths excavation not exceeding 3 metres below ground level. [HSR 6.10 (a)].
Drilling and Tapping cast iron pipe lines of all diameters and screwing in ferrule and connections-Size of ferrule. (vi) 40 mm internal diameter of pipeline. [HSR 28.22].
Cutting holes upto 23 cm square through brick work in mud walls for pipes and making good including repointing replastering and finishing according to existing finish where required. [HSR 28.23]. (i) 11.43 cm thickness of walls
(ii) 22.86 cm thickness of walls
Labour for fixing G.I. or W.I. pipe sleeve pieces in holes in walls, floors, and roofs rounds pipes including all cutting and wastage. [HSR 28.27]. (a) 15 mm internal diameter
(b) 20 mm internal diameter
(c) 25 mm internal diameter
(d) 32 mm internal diameter
(e) 40 mm internal diameter
Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-In-charge. (a) Upto 200 mm internal diameter. [HSR 28.47 (a)].
Constructing brick masonry inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent limer mortar 2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2;4 slab 100 mm thick./C.C. topping 50 mm thick with 455 mm x 455 mm 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint coplete as per standard design. [HSR 29.84]. (a) Size 450 mm x 450 mm
(b) Size 450 mm x 450 mm
(c) Size 600 mm x 900 mm
Extra for over 0.30 metre depth of inspection chamber. (c) 600 x 900 mm. (HSR 29.85)
Constructing brick masonry road gully chamber as per standard drawings (as per sizes given below) including dressing of beds and sides of chamber to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item no 10.6) in foundation, Ist class brick work laid in cement sand mortar, 1:5, 40mm thick cement concrete 1:2:4, topping inside the chamber with a floating coat of 1.5 mm thick neat cement laid in one operation to the topping the entire inner surface of the chamber rendered with neat cement not less than 12 mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1 mm thickleft absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as specified in item no. 29.48 complete and to the requirement of the Engineer-In-charge). (a) Single Road Gully Chamber (i) Size 610 mm x 457 mm x 800 mm. [HSR 29.87 (a) (i)].
CONSTRUCTION OF RECTANGULAR STANDARD BRICK MASONRY MANHOLE CHAMBERS to standard drawings on S.W pipe sewers or other circular pipe sewers upto the required depth in 1.5 CEMENT SAND MORTAR, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium solicate on interior surface where required, reinforced cement concrete slab 180 mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. The rate cover the cost of M.S steel for R.C.C slab Labour for fixing and carriage of C.I manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also includes the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. Sodium silicate shall be supplied free of cost at the stores of Engineer- in-charge. [HSR 29.90 (ii)]. (ii) On 150 mm I/d Pipe sewer (a) For 1.20 Mtrs. depth below ground level
(b) For 1.50 Mtrs. depth below ground level
(c) For 1.80 Mtrs. depth below ground level
Providing, lowering, laying, cutting (cut surface to be uniformity finished) jointing with rubber rings marked with IS:5382 and testing of SPIGOT AND SOCKETTED RCC NP2 MARKED WITH IS:458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction to the Engineer -in-charge. (c) 300 mm dia. (HSR 29.93). (b) 250 mm dia
(c) 300 mm dia
(d) 350 mm dia
Providing SALT GLAZED STONE WARE PIPES GRADE 'A' IN STANDARD LENTH OF 600 MM EACH PIPE MARKED WITH IS;651 and their lowering, cutting, jointing and testing as described in HSR item no. 29.38, 29.39, 29.40 inlcuding the cost of jointing materials as well as carriage, loading, unloading, stacking handling, re-handling etc. complete in all respect to the satisfaction to the Engineer-in-Charge. (b) grade 'A' 200 mm (HSR 29.95) (c) 200 mm dia
(d) 250 mm dia
Providing & Fixing in position best Indian make (to the approval of the Engineer-in-charge). Indian orissa or orya water water closet suite for sinking into floor, with raised foot treats complete with 100 mm H.C.I.'P' trap with or without vent as required and all other necessary fitting as fully described. (b) Size 630 mm (ii) Single Colour. (Make Hindware) [HSR 30.2 (b) (ii)].
Providing and fixing in position best indian make (as approved by the engineer-in-charge European type water closet suite, syphonic type consisting of- (i) VITREOUS CHINAWARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (as approved by the Engineer-in-charge). (ii) One piece SEAT AND LID IN HOLLOW BLACK OR WHITE PLASTIC fitted with chromium plated hinges and rubber buffers, (to the approval of the Engineer-in-charge) COMPLETE in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS. (b) Double trap syphonic (ii) Single Color. [HSR 30.5 (b) (ii)].
EXTRA OVER item nos. 30.1 to 30.4 and 30.6 FOR PROVIDING AND FIXING 15 LITRES CAPACITY C.I. LOW LEVEL VITREOUS CHINAWARE CISTERN complete with flush bend all other necessary Fittings instead of C.I high level cistern complete with fittings. (i) White. [HSR 30.12 (i)].
EXTRA OVER item nos. 30.3 to 30.6 FOR PROVIDING AND FIXING BEST INDIAN MAKE PLASTIC HYGENIC SEAT with lid complete instead of hollow Black or white plaster seat and lid.(i) White plastic seat (Solid). [HSR 30.13 (i)].
EXTRA FOR providing and fixing 32 MM dia G.I./C.P FLUSH PIPE complete with accessories instead of 32/MM dia galvanized telescopic flush pipe with clips (as required by the Engineer-in-charge). (i) 32 mm dia G.I. flush pipe. [HSR 30.15 (i)].
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE FLAT BLACK OR ANGULAR LIPPED FRONT URINAL 465 MM HIGH consisting of:- (i) flat black lipped or angular urinal basin of VITREOUS CHINA WARE (to the approval Of the Engineer-in-charge). (i) White. [HSR 30.19 (i)].
Providing and fixing 25 mm thick marble partitions for different type of urinals. (b) Vetreous Chinaware Partition Plate. (ii) Large Size 835 mm x 335 mm. (i) White. (HSR 30.40).
Providing & Fixing in position best indian make (ordinary) lavatory suites consisting of:- (v) Size 560 mm x 450 mm with one no. tap. [HSR 30.41(v)].
PROVIDING AND FIXING IN POSITION 32 MM DIA G.I. WASTE PIPE EMBEDDED IN WALL or lead waste pipe (weighing 3.47 kg. per metre and 2.8 mm thick) upto floor Level including cost of wipped solder joint etc., complete (as required by the Engineer-in-charge). [HSR 30.48].
Providing and fixing in position best Indian make chromium Plated brass Bottle trap 32 mm dia metre. complete (as required by the Engineer-in-charge). [HSR 30.50]
Providing and fixing in position best quality Stainless Steel Sinks with Complete fittings as fully described in item No. 30.51. (a) 600 mm x 450 mm x 200 mm. [HSR 30.53 (a)].
Providing and fixing 40 mm I/D Stainless Steel waste pipe embedded in walls or lead waste pipe weighing 4.46 Kg./metre and 3.0 mm thick upto floor level as required by the Engineer-in-charge including cost of union and plumber joint. (HSR 30.62)
Providing and fixing 40 mm i/d chromium plated brass trap with chromium plated bra pipe to wall with wall flange, complete (as per requirement of the Engineer-in-charge) for use with sinks. (a) with Bottle Trap (indian make). [HSR 30.63 (a)].
Providing and fixing in position best indian make shower with 125 or 20 I/D in-let. (d) C.P. brass with telephonic shower. [HSR 30.66 (d)].
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE PAPER HOLDERS FIXED INTO wall with C.P Brass screws complete in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) C.P. Brass. [HSR 30.67 (a)].
Providing and fixing in position best Indian make towel rails fixed in with rawlslugs embedded in walls with C.P. Brass screws, complete in all respect including cutting and making goods the walls etc.: (a) 25 mm dia, C.P. Brass adjustable. (i) 750 mm long. [HSR 30.68 (a)]
Providing and fixing in position glass shelf fixed in with rawl plugs with C.P. Brass screws, complete including cutting and making good the walls etc. (a) with C.P. Brass brackets and guard rail. (i) 600mm x 125 mm . [HSR 30.69 (a) (i)].
Providing and fixing in position best Indian make Soap dish fixed into wall with C.P. brass screws and complete in all respects including cutting and making goods the walls etc. (a) C.P. Brass (i) Soap dish Large. [HSR 30.70 (a) (i)].
Providing & fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on absetos sheet ground fixed in postion by means of 4 Nos. chromium plated brass screws and washers over rubbers washers and rawl plug embeded in the wall or chromium plated brass clamps with C.P. brass screws (as required by the engineer-in-charge) complete including cutting and making good the walls etc. (a) Indian Make (i) 600 mm x 450 mm. [HSR 30.71 (a) (i)].
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE COAT AND HAT HOOKS fixed into wall with C.P Brass screws and rawl plugs etc. COMPLETE INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) C.P. Brass. (ii) Two Way. [HSR 30.73 (a) (ii)].
Providing and fixing in position super quality 65 mm i/d opening C.P brass dome type hinged grating weighing about 750 gms fixed in cement mortar 1:2 complete in all respects (as required by the Engineer-in-charge). [HSR 30.74].
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75]. (a) Bib cock long body.
(c) Bib cock (short body)
Providing & fixing in position C.P. brass stop cock (as approved by the engineer-in-charge). (a) 15 mm Stop cock. (ii) Concealed stop cock with flange. [HSR 30.76 (a) (ii)].
Providing and fixing C.P brass liquid soap container of best quality (as required by the Engineer-in-charge). [HSR 30.77].
Providing and fixing in position best indian make C.P. Brass Tooth Brush cum Tooth Paste Holder fixed in with rawl plugs with C.P. Brass screws complete including cutting making good the walls etc. (ii) Tooth Brush Holder. [HSR 30.79 (ii)].
Providing and fixing of best Indian make C.P. Brass wall mixer 15 mm. (a) With Telephonic Shower. [HSR 30.81 (a)].
Providing and fixing in position best Indian make flexible tube connection. (b) C.P. Brass (iii) 15mm x 450 mm. [HSR 30.82 (b) (iii)].
Providing and fixing in position C.I. Gully trap cover weighing approximately 7.26 Kg. and frame for gully trap chamber clear opening size 300 mm x 300 mm and out side size 330 mm x 330 mm including painting the exposed surfaces with 3 coats of black bitumastic superior paint of approved manufacture etc. (HSR 30.85).
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat not less than 5 mm of the approved design for fixing C.I. soil waste vent or anti pipes to walls complete in all respects. (a) for 100 mm interal diameter pipes. (HSR 30.88). (a) for 100 mm interal diameter pipes.
(b) for 75 mm interal diameter pipes.
Providing and fixing in position automatic brass ball valves in tanks. (b) With Plastic Ball (ii) 20 mm internal diameter. [HSR 30.110 (b) (ii)].
Providing & Fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm x 150 mm cast iron cover weighing approximately 7.26 Kg. and frame clear opening 300 mm x 300 mm and outside size 330 mm x 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:2:4, in coping black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm. (b) 100 internal diameter H.C.I. gull trap. [HSR 30.114 (b)].
Providing and Fixing HDPE WATER STORAGE TANKS of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers flages for connections in tanks complete in all respects to the satisfaction to the Engineer-in-Charge. [HSR 30.119]. 500 Ltrs. Capacity Water Tank
1000 Ltrs. Capacity Water Tank
2000 Ltrs. Capacity Water Tank
DSR ITEMS Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. (DSR 18.7). (iv) 32 mm internal diameter of pipeline
(v) 40 mm internal diameter of pipeline
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (DSR 18.8). (i) 15 mm internal diameter of pipeline
(ii) 20 mm internal diameter of pipeline
(iii) 25 mm internal diameter of pipeline
Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (Screwed end). (DSR 18.17) (b) 20 mm nominal bore
(c) 25 mm nominal bore
(d) 32 mm nominal bore
(e) 40 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New Work). (DSR 18.46) (a) 15 mm nominal bore
(b) 20 mm nominal bore
(c) 25 mm nominal bore
(d) 32 mm nominal bore
(e) 40 mm nominal bore
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. (DSR 19.16).
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : (i) For pipes 100 to 250 mm diameter. [DSR 19.21.1].
Boring/drilling bore well of required dia dor casing/strainer pipe, by suitable method prescribed in IS: 2880 (part I), including collecting samples from different strata preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants and machineries, pit for water, arragement of water including water charges etc as required for the job all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. (i) All type of Soil. (i) 300 mm dia. ([DSR 23.1.1.1)].
Boring/drilling bore well of required dia dor casing/strainer pipe, by suitable method prescribed in IS: 2880 (part I), including collecting samples from different strata preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants and machineries, pit for water, arragement of water including water charges etc as required for the job all complete as per direction of Engineer-in-charge, beyond 90 metre & 150 metre depth below ground level. (i) All type of Soil. (i) 300 mm dia. ([DSR 23.2.1.1)].
Supplying, assembling, loweing and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (i) 150 mm dia. [DSR 23.3.2).
Supplying, assembling, loweing and fixing in vertical position in bore well, unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (i) 150 mm dia. [DSR 23.4.2].
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR 23.5).
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR 23.6).
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. (DSR 23.7).
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (DSR 23.8).
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). (2) 150 mm dia. (DSR 23.15.2)
NS ITEMS Providing and laying uPVC Pipe (working Pressure 6 Kg/Sqcm), including specials like:- Floor traps, Heal rest bend, Double Junction with door, Single Junction with door, Bend with Door, Bend Plain, Cowls, Door piece, Collars, Nani Trap, P-Trap etc. The Rate shall be inclusive of Chemical for jointing, hanging arragement below ceiling concreting around floor trap and other misc. complete in all respect as per satisfaction of Engineer-in-Charge. Make:- Diplast, Kisan, Truflo (Hindware). (NS). (a) 100 mm internal diameter.
(b) 75 mm internal diameter. Note:- 1. In case of any difference in the unit & nomenclature of any of the HSR/DSR Items of Civil & P.H. work depicted in this DNIT and that given in HSR/DSR, the unit and nomenclature given in HSR/DSR shall be applicable. 2. Only reputed make material will be used (make/brand exhibited in HSR/DSR and exhibited in approved standard document) as approved by Engineer-in-charge, while executing various items/works at site.
Providing laying ,testing & commissioning of ( C ) class heavy duty MS pipe conforming to IS 3589/ IS 1239 including Welding ,fittings like elbows ,tees ,flanges,tapers ,nuts bolt ,gaskets etc . And fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complite as required . MAKE HISAR JINDEL , TATA ,PARKSH SURYA . (A) 250 mm dia ( MINIMUM 6.3 MM THIKNESS ) ( DSR Code No. 7.10 )
(B) 200 mm dia ( MINIMUM 6.3 MM THIKNESS )( DSR Code No. 7.9 )
(C) 150 mm dia ( DSR Code No. 7.8 )
(D) 100 mm dia ( DSR Code No. 7.7 )
(E) 80 mm dia ( DSR Code No. 7.6 )
(F) 65 mm dia ( DSR Code No. 7.5 )
(G) 50 mm dia FOR DRAIN ( DSR Code No. 7.4)
(H) 40 mm dia ( DSR Code No. 7.3 )
(I) 32 mm dia ( DSR Code No. 7.2 )
(J) 25 mm dia ( DSR Code No. 7.1 )
Providing laying ,testing & commissioning of ( C ) class heavy duty MS pipe conforming to IS IS 1239 /3589 i/c fitting like elbows ,tees ,flanges ,tapers ,nuts bolt , gaskets etc .in ground including welding ,excavation & providing cement concrete blocks as supports , anticorrosive treatment with coaltar /asphalt tape as per IS 10221 reffilling the trench etc .of following sizes complete as required make PYPECOAT/COALTEK (A) 150 mm dia (MINIMUM 6.3 MM THIKNESS) ( DSR Code No. 6.2 )
Providing ,fixing ,testing & commissioning of 15 mm dia quartzoid bulb type brass sprinklers of rating 68 degree centigrade with required accessories Pendent type ( MAKE: TYCO /SAFEX/ HD/ KARTAR ,FIRE CUT, NEW AGE ) ( DSR Code No. 21.1 )
Providing ,fixing ,testing & commissioning of 15 mm dia quartzoid bulb type brass sprinklers of rating 68 degree centigrade with required accessories UPRIGHT type ( MAKE: TYCO /SAFEX/ HD/ KARTAR ,FIRE CUT, NEW AGE ) ( DSR Code No. 21.2 )
Supply, installation, testing & commissioning of sprinkler flexible pipe 1500mm (UL listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (BURST) with branch line (inlet) 25mm NPT male thread to sprinkler head (outlet) 15mm NPTfemale thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complite as required OMEX, FIRE CUT, ATTACK FIRE (DSR Code No. 25.4)
Supplying and fixing single headed internal and external yard hydrent valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 ( TYPE -A ) with blank stainless steel cap and chain as required ( MAKE: TYCO /SAFEX/ HD/ KARTAR ,FIRE CUT, NEW AGE ) ( DSR Code No. 9.2 )
SITC of INTERNAL OR EXTERNAL weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner. (For external hydrant system) (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SUPEREX / KARTAR ) ( N.S )
Supplying and fixing 63 mm dia ,15 m long RRL hose pipe with 63 mm dia male and femaile coupling duly bond with GI WIRE , RIVETS ETC . CONFORMING TO IS 636 (Type -A ) as required . (MAKE: / FIRE CUT /NEWAGE/ / MINIMAX/,KARTAR/ SAFEX ( DSR Code No. 16.2)
Supplying & fixing 63 mm dia Stainless Steel (grade 304 ) short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 sutitable for instantaneous connection to IS 903 sutitable for instantaneous connection to interconnect hose pipe coupling as required (MAKE: / FIRE CUT /NEW AGE/ KARTAR / MINIMAX / SAFEX ) ( DSR Code No. 18.2 )
Supplying and fixing firsr-aid Hose Reel with MS construction spray painted in post office red , conforming to IS 884 complite with the follwing as required . 20 mm nominal internal dia water hose thermoplastic (Textile reinforced ) type-2 as per IS 12585. 20 mm normal internal dia gun metal globe & nozzle. Drum and brackets for fixing the equipmets on wall.connections from riser with 25 mm dia stop gunmetal valve & MSpipe and socket ((MAKE: FIRE CUT / NEW AGE/ MINIMAX / KARTAR/ SAFEX) (DSR Code No. 17.1 )
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd , for sutitable dia MS pipe connection conforming to IS 904 AS REQUIRED .4 WAY -150 mm dia MS pipe Make Minimax, FIRE CUT,KARTAR , NEW AGE, SAFEX .MINIMAX ( DSR Code No. 19.2 )
Providing , installation , testing and commissioning of stainless steel Y- strainer fabricated out of 1.6 mm thick stainless steel, grade 304 , sheet with 3 mm dia hole with stainless steel flange . 250 mm dia .MAKE-KARTAR/LEADER,NEW AGE ,SANT ( DSR Code No. 15.5 )
Supplying and fixing air vessel made of 250 mm dia ,8 mm thick MS sheet , 1200 mm in height with air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia gun metal wheel valve with required accessories , pressure gauge and paintingwith synthetic enamel paint of approved shade as required . MAKE FIRE CUT / HYDROTECH . ( DSR Code No. 20 )
SITC OF Providing & Fixing of air vessel 450/1600mm dia,height with dish top made in 6mm thick ms pipe complete with 20 mm dia brass air valve , 200mm dia stop valve , pressure gauge ,stop cock, nipple for fire control room MAKE FIRE CUT / HYDROTECH .( NS )
Supplying and fixing orifice plate made out of 6mm thick stainless steel ( Grade 304 ) with orrice of required size to be fitted between flange & landing valve of external and internal hydrent to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required .MAKE-SANT,LEADER,KARTAR / SAFEX OR EQULENT ( DSR Code No. 13 )
Supplying , fixing , testing and commissioning of butterfly vave of PN 1.6 rating with bronze /gunmetal seat duly ISI markedcomplete with nuts , bolt , washers ,gaskets conforming to IS 13095 OF FLOWING SIZES AS REQUIRED MAKE-KARTAR,/ZOLOTO/ CASTLE,KIRLOSKAR, NEW AGE ,SANT ,OR EQULENT (DSR Code No. 11) (A) 250 mm dia ( DSR Code No. 11.8 )
(B) 150 mm dia ( DSR Code No. 11.6 )
(C) 100 mm dia ( DSR Code No. 11.5 )
(D) 80 mm dia ( DSR Code No. 11.4 )
(E) 50 mm dia ( DSR Code No. 11.2 )
Providing , installation , testing and commissioning of non-return valve of following sizes confirming to IS 5312 complete with rubber gasket . GI bolt ,nuts , washers etc .as required MAKE-KARTAR,/ZOLOTO/ CASTLE,KIRLOSKAR, NEW AGE ,SANT ,OR EQULENT (A) 250 mm dia ( DSR Code No. 14.9 )
(B) 150 mm dia ( DSRCode No. 14.7 )
(C) 100 mm dia ( DSR Code No. 14.5 )
Providing & fixing of pressure switch in M.S pipe line including connection MAKE -INDOFUS/DANFOS/SWITZER) ( DSR Code No. 22 )
SITC of fire brigade draw off connection confirming to IS : 4038-1986 with 150 mm Non return valve/ strainer incluiding necessary fittings the word FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and directed.(MAKE: FIRECUT/KARTAR/ NEW AGE / MINIMAX) ( NS )
Providing, fixing, testing & commissioning of 100 mm dia Burden type, Stainless Steel dial type pressure gauge (in Pump Room) including brass isolation valve and pipe having caliberation of 0-15 Kg/cm2. MAKE H.GURU/FIEBIG ( N.S )
MECHANICAL/ELECTRICAL PUMPS-Fire Hydrants Supplying , installation , testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following , complite in all respect , as required ( Diesel Driven Pump ) horizontal type , multistage , centrifugal pump of cast of iron body and brinze impeller with stainless steel shaft , mechanical seal conforming to IS 1520 OF Suitable HP ,1500 RPM water cooled with radiator , diesel engine conforming to relevant IS standard complete with autostarting mechanism , 12 /24 volt electric starting equipment , disel tank , exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick almunium sheet cladding , residebtial silencer , instruments and protection as per standard specification ,stop solenoid for auto stop in the ecent of fault with audio indications , painted with post office red colour etc .as required . M.S fabricated ,common base plate coupling ,coupling guard , foundation bolt etc .as required . . MAKE KILOSKER , LUBI MOTHER AND PLATT , ASHOK LEYLAND 2280 LPM at 88 Mtr Head, ( DSR Code No. 2.4 )
Supplying , installation , testing and commissioning of electric driven Main Fire Pump suitable for automatic operation and consisting of following , complete in all respects , as required . (a ) Horizontal type , multistage , centrifugal , split casing pump of cast iron body & bronze impeller with stainless steel shaft , mechanical seal conforming to IS 1520 ( b ) suitable HP squirrel cage induction motor ,TEFC , synchronous speed 1500 RPM ,suitable for operation on 415 volt , 3 phase 50 Hz ,ac supply with IP 55 protection for enclosure , horizontal foot mounted type with class ' F ' insulations , conforming IS -325 FOR SPRINKLER SYSTEM SYSTEM MAKE KILOSKER , LUBI MOTHER AND PLATT , ASHOK LEYLAND 2280 LPM suitable for 88 Mtr Head (DSR -1.4 )
Supplying , installation , testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following , complete in all respects , as required ; (Jockey Pump ) Horizontal type , multistage , centrifugal pump of cast iron body and bronze impeller with stainless steel shaft , mechanical seal conforming to IS; 1520 . Suitable HP squirell cage induction motor tefc type suitable for operation on 415 volt , 3 phase 50 HZ AC supply with IP 55 class of protection for enclosure , horzontal foot mounted type with class- ' F 'insulation,conforming to IS; 325 M .S fabricated common base plate , coupling ,coupling guard , foundation bolt etc as required . M.S fabricated bolt etc as required . Suitable cement concrete foundation duly plastered and with anti vibration pad MAKE KILOSKER , LUBI MOTHER AND PLATT , ASHOK LEYLAND 180 LPM suitable for 88Mtr ( DSR Code No. 3.1 )
Supplying , installation , testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following , complete in all respects , as required ; ( Terrace Pump ) (a ) Horizontal type , multistage , centrifugal , split casing pump of cast iron body & bronze impeller with stainless steel shsft , mechanical confirming to IS; 1520 ( b ) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volt ,3 phase ,50 Hz , AC supply with IP55 class of protection for enclosure , horiziontal foot mounted type with class - 'F 'insulation , conforming to IS- 325 ( c ) M.S fabricated common base plate ,coupling ,coupling guard , foundation bolt etc as required . ( d ) Suitable cement concrete foundation duly plastered and with anti vibration pads . MAKE KILOSKER , LUBI MOTHER AND PLATT , ASHOK LEYLAND 450 LPM at 35 m head ( DSR Code No. 4.2 )
SITC OF DOL type fire pump panel suitable for 450 lpm fire pump 415 V+/-6 volts,panel shall be free standing floor mounting sheet metal enclosed dust and verming proof.Panel shall be provided with heat shrinkable sleeves and shall be coloour coded. The panel shall be suitable for cable entry from top or bottem. The minimum fault rupturing for all incoming and outgoing switch/ breakers shall be 35 KA. The panel shall be fabricated.Auto mannual Starters with change over system. MAKE ( , FIRE CUT,HYDROTECH attack fire ( N.S )
Supplying and making end termination with brass compression gland and almminium lugs for following size of PVCand PVCsheathed /XLPE almuminium conductor cable of 1.1 KV grade as required (MAKE:RR/FINOLEX/polycab ) 3.CORE x 95 sq. mm (From Fire Fighting Control Panel to main fire AND SPRINKLAR pump) ( DSR E &M Code No. 9.1.13 )
3 CORE x 35 sq. mm (From Fire Fighting panel to jockey pump) (DSR E & M Code No. 9.1.10 )
2 core x 1.5 sq .mm For pressure switch to fire panel and fire annuciator panel and flow switch ) supplying and drawing FRLS PVC insulated copper conductor cable ( DSR E &M Code No. 1.17.2 )
3.CORE x 10 sq. mm (From Fire Fighting Control Panel to main fire pump) ( DSR code E &M No. 9.1 .7 )
Proviing , fixing , testing & commissioning of installation control valve of cast iron body , brass /bronze working parts comprising of water moter alarm , bronze seat clapper , clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser / sprinkler system activates , pressure switch, cock valve complete with drain valve and bypass , test control box , ball valves MS PIPE OF REQUIRED SIZE , FLANGES , ORIFICE PLATE , GASKET ETC OF FOLLWING SIZES AS REQUIRED 150 MM DIA MAKE - HD, OMEX , GETECH , NEWAGE (DSR Code No. 24.3 )
AUTO GLOW EXIT SIGNS AUTO GLOW EXIT SIGNS AND INDICATION SIGNS SIZE 12 "x 6", MAKE FIRE CUT AND ATTACK FIRE ,DP lndication every exit point,fire point,fire extinguisher . (N.S )
FIRE EXTINGUISHERS SUPPLY AND INSTALLATION of ISI marked (ISI MARK 15683) portable Co2 fire extinguisher of capacity 4.5 kg flat base including valve , dischargeone metar long hose of . meter complete in all respect with explosive certificate .(MAKE: Ceasefire/FIRE CUT /Minimax, safex / kanax ( N.S )
SITC of ISI marked (IS: 15683) portable ABC multipurpose filled by 90% (MAP ) mono amonioum phosphate powder , nitrogen pressurised type fire extinguisher, Capacity 6 kg with 90% map complete in all resp. MAKE (FIRE CUT ,CEASE FIRE ,MINI MAX ,SAFEX , KANAX , ) ( N.S )
SITC of Clean Agent type ISI mark IS code 15683 2006 Fire Extinguisher capacity: 2 kg MAKE (MAKE FIRE CUT ,,CEASE FIRE ,MINI MAX ,SAFEX , KANEX,) location - O.T room, nursing station, lab machinry room pantry kitchen ( N.S )
SITC of 5 kg modular type self operated on 68o temperature Clean Agent type CE certified Fire Extinguisher filled with NAFPIV clean agent gas MAKE (FIRE CUT ,CEASE FIRE ,MINI MAX ,SAFEX , KANAX , ) location electrical shaft ,electrical control room servar room other places where water or other camical are prohibited . ( N.S )
SITC of 50 KG DCP (Dry Chemical Powder) Trolley type fire extinguisher as per IS 16018I jet length minimum 8 mtr minimum discharge time 40-50 sec,tested on 30 kgf/cm2 MAKE (FIRE CUT ,CEASE FIRE ,MINI MAX ,SAFEX , KANAX .location dg room , fire control room , ground floor of every block . ( N.S )
SITC of 50 KG Mechanical Foam AFFF Trolley type fire extinguisher as per IS 16018 jet length minimum 10 mtr minimum discharge time 60-180 sec,tested on 35 kgf/cm2 with 2 kg co2 external fire extinguisher MAKE (FIRE CUT ,CEASE FIRE ,MINI MAX ,SAFEX , KANAX , ) location dg room , fire control room , ground floor of every block . ( N.S )
SITC of 9 ltr capacity Fire Bucket made in 16 guage MS filled by 9 kg sand with MS angle stand having arrangement of hanging 6 buckets with shed MAKE (FIRE CUT ,KARTAR) ( N.S )
FIRE CHECK DOOR SITC OF 46 mm steel fire check door of 120 minut fire rating confirming to bs 476 part -22 and is 3614 part-11 fabricated with 2 no , 1mm thick galvnized steel sheet sandwiching with proprietary fire resistant insulation materials in between . The door frames are manufactured from 1.5mm thick galvanized steel sheet pressed from to double rebate profile of size 143mm x 57 mm . the door frame and door shutters to finish with powder coatingSITC OF 2HR FIRE RATED METAL DOOR MAKE LAKSHITA FIRE ,INDIAN FIRE , FIRE CUT . location- basement stair case , electrical cantrol room and all floor stir case where there is no natural vantilation ( NS )