Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹16.4 L+₹10,958.32 (0.67%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹20.9 L+₹4.5 L (27.7%)Rejected-AOC | L3 | Rejected-AOC Other than lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
6 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
ROUTINE DAY TO DAY MAINTENANCE OF MISCELLANEOUS REPAIR OF 07XNOS HOT WATER BOILER AND 04XNOS WATER SUPPLY INSTALLATIONS AT AIR FORCE THOISE
2022_MES_541949_2
GEAF/T-20/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER (AF) THOISE
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE AF Thoise
₹40,000
Yes
7 Dec 2022
21 Sept 2022
8 Oct 2022
21 Sept 2022
6 Oct 2022
23 Sept 2022
60 days
Amount
Servicing of Hot Water Boiler , Disconnecting electric drain out water opening of burner chamber boiler asembly, all accessories and mounting taking out helical coil of make-Alfa Therm hot generator 100000K Cal/Hrs, cleaning of combustion chamber repairing/replacement of any unserviceable parts as specified in each item complete all as specified and directed by Engr-in-Charge. Note :- The Job shall be carried out after every 2 Month of Boiler run .
Repair of hot water boiler of capacity 100000 K. cal/Hr including repair/replacement of following parts from Srl item No. 2.01 to 2.13 to make it functional as specified and directed by Engr-in-Charge.
Replacement of complete helical coil assembly.
Replacement of input ignition transformer 220 Volts of outpot 11 KV to 14 KV.
Replacement of gasket suitable for hot water boiler.
Replacement of sequence controller for hot water boiler.
Replacement of refactory plate as per sample.
Replacement of differenial pressure Gauge - 0 to 10 Kg/Cm square suitable for hot water boiler.
Replacement of Photo cell for hot water boiler.
Supply and Fixing in replacement motorised barrel pump of capacity 1 HP, 2850 RPM , Single phase with rubber hose pipe 15 RM complete with all accessories complete all as specified and directed by enger in charge.Make : Bharat, Kirloskar
Replacement of un-serviceable gate valve of capacity 50 mm dia suitable for hot/cold water Make Leader/Surya Parkash/Zoloto/Kartar ISI marked
Replacement of un-serviceable gate valve of capacity 40 mm dia suitable for hot/cold water Make : Leader/Surya Parkash/Zoloto/Kartar ISI marked.
Replacement of solenoid valve for hot water boiler.
Replacement of fuel TPL pipe to burning assembly for hot water boiler.
Replaement of fuel filter assembly 1/2 Ltr capacity with filter.
S&F in repair/ Replacment of Burner of Boiler for 1 L K cal make Ecoflame or Equivalent or as per sample complete all as specified and as directed by Engr-in-Charge.
S&F in repair/ Replacment of Starting Panel of Boiler for 1 L K cal make as per sample Rapid Cool complete all as specified and as directed by Engr-in-Charge.
S&F in repair/replacment of Electronic Buzzer for Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
S&F in repair/replacment of MNX 9 Contacter type for Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
S&F in repair/replacment of Bimetallic Relay of 3 to 5 Amp for Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
S&F in repair/replacment of Single Phase Preventer for Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
S&F in repair/replacment of Control Module for Hot Water Boiler of 1 L Kcal complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement, testing and commissioning of centrifugal pump set of capacity 3 HP, 3 Phase,2880 RPM, Head 22 to 33m, size 50x40 mm, discharge 4.50 to 2.50 l/s as specified and directed by Engr-in-Charge.
Supply and fixing in replacement, testing and commissioning of centrifugal pump set of capacity 5 HP, 3 Phase, 2880 RPM, Head 22 to 33m, size 50x40 mm, discharge 4.50 to 2.50 L/s as specified and directed by Engr-in-Charge.
Taking down old unserviceable cable and Supply and laying of PVC insulated sheathed 6 sqmm, 4 core flat multistrand copper conductor cable complete all as specfified and directed by Engr-in-Charge
S&F in replacement complete Insulation wrapping for the tank in all boiler with 75 mm thick bounded mineral wool with wire mesh inclding provision of aluminium foil cover complete all as specified and directed by Engr-in-Charge.
Rewinding of Pump motor of capcity 5 HP with super enamelled copper & wire of same gauge etc using best quality of insulation materials turning polishing of motor shaft by machining, replacement of bearing - 02 Nos including all necessary repair work to make the equipment functional complete all as specified and as directed by Engr-in-Charge.
Rewinding of pump 3 HP with replacemnt of different unserviceable parts including all necessary repair work to make the equipment fully functional complete all as specified and as directed by Engr-in-Charge. Note :-Spare parts to be replaced for this item will be measured and paid separately.
S&F in replacement of following Srl item No. 16.01 to 16.06 here-in-after as required for overhauling/repairing the submersible pump set under srl item No 10.00 and 11.00 here-in-before.
Impeller
Pump shaft
Thrust Bearing
Water seal
Bushing
Emptying & cleannig of water tank of capacity 10,000 ltr PVC insulated sintex tank using cleaning solution and de-silting as specified and directed by Engr-in-Charge.
S&F in replacement star delta starter suitable for 5 HP submersible pump as specified and directed by Engr-in-Charge.
S&F in replacement star delta starter suitable for 20 HP submersible pump as specified and directed by Engr-in-Charge.
S&F in replacement star delta starter suitable for 3 HP submersible pump as specified and directed by Engr-in-Charge.
M&L KFlex insulation for galvanised water tubing and 19 mm thick including jointing & fixing material such as solvent adhesive , tape insulation self adhesive and polyshield coating, including polyglass tape and (Resion + Hardner) two coats as per manufacturer's recommendation including taking down following size listed at Srl No. 21.01 and 21.02 here-in-after complete all as specified and directed by Eng-in-Charge. Make : KFlex/ superion or equivalent as approved by GE.
50 mm dia
40 mm dia
Taking up or down GI tubing and connections including cleaning & re-fixing and removal of following size listed at Srl Item No. 22.01 and 22.02 here-in-after complete all as specified and as directed by Engr-in-Charge :-
50 mm dia
40 mm dia
S&F Steel water tube medium grade galvanised with all fittings including short lengths, laid in trenches/floors/wall with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) following size listed at Srl Item No. 23.01 and 23.02 complete as specified and as directed by Engr-in-Charge. MAKE:- JINDAL / SWASTIC/ TATA / PARKASH
50 mm dia
40 mm dia
Supply, laying & Insulation of pipe line 75 mm thick bounded by mineral wool with wire mesh comletes inclding provision of aluminium foil cover complete all as specified and directed by Engr-in-Charge.
Taking down of existing MS Sheet hot water storage 1500 Ltrs tubular tank from the mounting and checking it for any leakages, damages etc and making on site arrangement for repair of tank by welding with suitable size MS plate making it completely leak proof and refixing the same after wraping with insulation at the existing height and dully fixing with fastner, nuts and bolts etc complete all as specified and directed by Engr-in-Charge.
Supply and laying of PVC insulated sheathed multi starnded copper cunductor submercible pump 20 HP cable 10 sqmm, 4 core mulfistrand copper conductor cable complete all as specfified and directed by Engr-in-Charge
Repair/Attending break down of Boilert to make completely functional in all respect to with out repalcing spare parts complete all as specified and as directed. Note:- The Item include any type of breakdown and sundry item cost deemed to be include in the quated rate.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426165 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens/Havells.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426165 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens/Havells.
M&L for in repair / replacment Change over switch, rating 200 Amps, four poles, 415 Volts, AC, 50 Hz, off load, conforms to IS:13947 (Part-3); IEC:60947-2, side handle, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- IHBFFE0200 or equivalent in Indo-Asian/ L&T/ Legrand/ Standard/ ABB/ Controls and switchgears/ Merlin Gerin/ Schneider/ Siemens.
Note: The work under subject BoQ (Srl item No. 1.00 to 30.00 ) is meant for maint and repair of Boiler in AF Stn Thoise under GE(AF) Thoise. The work shall be executed on ground on required basis but being remote station and extreme weather condition contractor must stand by all the material and Engineer to rectify the breakdown of Boiler. Contractor shall deploy sufficient resources to keep smooth working of Boiler in the AF station. In addition, any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notifying the complaint, recovery @ Rs 2000/- per day shall be recovered from contractor's payment for each breakdown so notified.
SANJEEV ENTERPRISES
M/S V K TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .