Tender Value
₹49.0 L
EMD Value
₹97,900
Closing Date
13 Jan 2020, 5:00 pmClosed
Sudhir Ransiwal
PHED Gurugram
Construction of One No. RCC Under Ground Tank of size 7.00x 7.00x 2.44 M , One No. Pump Chambers of size 3.66 M x 3.05 M, Boundary Wall (140 M), C.C.Road an Path, Providing and installation of Horizontal Submersible Pumping Machinery of 1200 LPM 35
2019_HRY_114198_1
Gurugram 12099-12171 dated 30/12/2019
Open Tender
Civil Works
Works
180 days
Babra Bakipur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
Yes
Engineer in Chief
₹97,900
Yes
5 Feb 2020
31 Dec 2019
14 Jan 2020
31 Dec 2019
13 Jan 2020
31 Dec 2019
Amount
Supplying, erection testing and commissioning of horizental submersible pumping set as per BIS Specification No.8034-1989 (as amended upto date for pump) and IS. 9283-1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having Characteristics as specified in Clause-4 of IS. 8034/1989 and Clause 4.1 of IS 9283/1979. Each pump motor set shall be supplied with joint free 50 M. double length PVC. Insulated and PVC. Sheathed flexible 4 mm2 type submersible Cable of finolex make and junction box for jointing of submersible Cable and Submersible pumping set. Clear water pump set 1200 LPM, 35 mtrs head 17.50 HP 3 Phase 50 Hz of suitable rating at Boosting Station.
Supply and fixing following CI D/F pipe and specials/Bell Mouth including cost of Jointing materials, excavation, laying, jointing, refilling including making adequate supports of masonry/ concrete/steel for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the department as per plan shown from the foundation wall of the pump chamber for all the raw water and clear water pumping sets at water works, as per specification given in schedule No. II for Bell Mouth 100mm i/d
Jointing Material. Nut and Bolts
Rubber Sheet
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stoutedwith suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following items complete in all respects for one No.Motor at Boosting Station.
Supply erection, testing of standard make Lighting in the Pump Chamber with material upto 10 points including Switch, Button, Plug, PVC Pipe & Wire etc
Supply, erection, testing of standard make CFL light 85 W with make Bajaj/ crompton including all acceries and pipe fitting etc.
Providing and Fixing Exhaust Fan 18' (450 mm) suitable acceries complete in all respect.
Making connection in fully charged 600 mm i/d pipe line complete in all respects.
Providing and Fixing Service cable 16 sqmm 4 core complete in all respects
Providing and fixing of making connection 100 mm dia complete in all respects
Road crossing by trenchless method complete in all respects
Bidder Name
Amount
RAJESH KUMAR CONTRACTOR
Unique Contractor
Kuldeep Singh Contractor
Unique Contractor
Kuldeep Singh Contractor
Unique Contractor
Kuldeep Singh Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .