| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.6 L+₹88,770 (2.99%)Rejected-Finance ALPHA HOUSE PLOT NO 29 AGP P10 ASHWIN SECTOR NEW CIDCO NASIK 422 009 | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹35.8 L+₹6.1 L (20.5%)Rejected-Finance FLAT NO 02 RUTUPARNA APARTMENT PLOT NO 36 S NO 324 2A NEAR G D SAWANT COLLEGE PATHARDI NASIK 422 010 | NASHIK | MAHARASHTRA | 422010 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹39.4 L+₹9.8 L (32.9%)Rejected-Finance R H NO 14 ADITYA PALACE PATOLE MALE B H SUMAN HOSPITAL JAI BHAWANI ROAD NASIK ROAD 422102 | NASIK | NASHIK | MAHARASHTRA | 422102 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹42.3 L+₹12.7 L (42.7%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
14 Apr 2025, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2025_MES_701627_1
GE/NRC/8712/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Nasik Road
₹1 L
14 Jul 2025
17 Mar 2025
16 Apr 2025
17 Mar 2025
14 Apr 2025
31 Mar 2025
Amount
Excavating in trenches, n exc 1.5 m wide and n exe 1.5 m in depth ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard /dense soil. Note:1.excavation to be carried out manually and very carefully without any damage to the existing underground cables/GI pipe line/OFC cable any other existing assests.Obtaining layout of cable/OFC/GI pipe line etc shall be responsibility of the contractor as per direction of engr-in-charge. 2.Any damage to the existing assets shall be made good by the contractor without any extra cost to the department within 24 hours of occurng of incident.For delay beyond 24 hours Rs 200 per day shall be recovered from the contractors RAR/Final bill as decided by GE. 3.Excavating in bituminous road and making good same in PCC 1:2:4 to the entire satisfaction of ground executive wherever required shall be included in quoted rate.Nothing extra shall be paid.
Excavating in trenches, n exc 1.5 m wide and depth exc 1.5 m but n. exc 3.0 m in ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10sq m on plan and exc 1.5 m but n.exc 3.0 m in depth and getting out in hard /dense soil. Note : 1.excavation to be carried out manually and very carefully without any damage to the existing underground cables/GI pipe line/OFC cable any other existing assests.Obtaining layout of cable/OFC/GI pipe line etc shall be responsibility of the contractor as per direction of engr-in-charge. 2.Any damage to the existing assets shall be made good by the contractor without any extra cost to the department within 24 hours of occurng of incident.For delay beyond 24 hours Rs 200 per day shall be recovered from the contractors RAR/Final bill as decided by GE. 3.Excavating in bituminous road and making good same in PCC 1:2:4 to the entire satisfaction of ground executive wherever required shall be included in quoted rate.Nothing extra shall be paid.
Returning,filling in, includings spreading, levelling, watering and well ramming in layers(hard/dense soil) not exc 25 cm each layer complete all as specified and direted.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point.
Removing excavated material exc. 250m but n.exc 500 m and depositing where directed at a level n exc. 1.5 m above the starting point
Demolition and breaking up drain pipe(salt glazed ware,AC or reinforced concrete) set in cement mortar all as specified and directed internal dia of pipe-150mm over and including demolition of pcc bed and haunching and removing debris out of MoD land.
Demolition and breaking up drain pipe(salt glazed ware,AC or reinforced concrete) set in cement mortar all as specified and directed internal dia of pipe-200mm over and including demolition of pcc bed and haunching and removing debris out of MoD land.
Demolition and breaking up drain pipe(salt glazed ware,AC or reinforced concrete) set in cement mortar all as specified and directed internal dia of pipe-300mm over and including demolition of pcc bed and haunching and removing debris out of MoD land.
M&L for Reinforced Cement Concrete Pipe of 150 mm dia class NP-2 laid and joined and tested complete with collars etc.
M&L for Reinforced Cement Concrete Pipe of 200 mm dia class NP-2 laid and joined and tested complete with collars etc.
M&L for Reinforced Cement Concrete Pipe of 300 mm dia class NP-2 laid and joined and tested complete with collars etc.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing rubbish out of MoD land.
M&L for PCC 1:4:8,Type D2, (using 40 mm graded stone ggregate) as in fondation filling and mass concrete mixing of concrete using mixer only.
Demolition of brickwork or stone/ boulder masonry, built in lime mortar/cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L for brick work with fly ash bricks,straight or curved on plan exc 6.0m mean radius,built in CM 1:6.
All as per Item No. 15.00 above but except brick.
Taking down cement or cement lime plaster,any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc
M&L for rendering 15 mm in cement Mortar 1:4 on brickwork or concrete surfaces making fair and even without using extra cement. ( water proofing measured separately).
Supply only integral water proofing compound.
M&L for Plain Cement Concrete 1:2:4 type B2 using 40 mm graded stone aggregate in , benching, rounded or chamfered on edges including necessary formwork.
M&L for Plain Cement Concrete 1:2:4 type B1 using 20 mm graded stone aggregate in coping, including weathering slightly rounded or chamfered angles and throating as directed.
Demolition of reinforced cement concrete(reinforcement cut to facilitate demolition) of any description and in any position not otherwise specifically provided for and removing rubbish out of MoD land.
M&L for Providing precast Reinforced Concrete (1;2:4 Type B1) using 20 mm graded stone aggregate,set in cement Mortar (1:6) in landing, cover slab (for manholes etc.) and similar articles with plain faces.mixing of concrete using mixer only.
M&L for Reinforcement with TMT bars 6 to 8mm dia, cut to length, bent to shape required includingcranking,bending sprirally and binding with and includingmild steel wire (annealed) not less than 0.90 mm dia.
Cleaning of septic tank/soak well by pumping out of sludge using (honeysucker trucks i.e by mechanical means) water,effluent etc. and removing all loose sedimented sand sludge,grit,ash, rags fibre and stirringly material and its removal to sewage treatment plant or as directed and emptying completely and in a depth exc 1.00 M and n.exc 6.00 M all as directed by Engineer in charge. Note :- Cleaning of septic tank/soakwell to be done on urgency basis within 24 hours of receipt of complaint through site order/telecommunication/any other electronic means failing which Rs 500 for each day delay from the date of receipt of complaint shall be recovered from the RAR or final bill of contractor as decided by the GE.cleaning of bushes to provided access for honey sucker truck wherever septic tanks are located in remote area or jungle shall be deemed to be included in quoted rate nothing extra shall be paid.
S&F in repairs vitreous china squatting patern "Orisa pattern" size 580mm x 440mm with trap white with intergral foot rest complete all as specifed and directed by Engineer -in-charge.
Dismantling floor hearth or wall tiling including cement mortar bedding (But not backing) removing serviceable tiles to store and rubbish off the premises.
M&L Non Skid ceramic tiles coloured 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm , in floors etc.incl 15 mm thk screed bed (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tile.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick backing coat in CM 1:4.
Dismantling of PVC rain/vent/waste pipe any bore any postion all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bends, any radius 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends, any radius 110 mm bore with oval access door complete all as specified and directed.
S&F PVC (SWR) branch piece, double (double Y) equal or unequal 110 mm bore with access door all as specified and directed.
S&F PVC (SWR) junction (single 'T') equal or unequal, bore 110 mm with access door, complete all as specified and directed.
S&F PVC (SWR) pipe single socketed 110 mm bore, any in length with rubber ring joints fixed to walls/floors along with PVC fixing clamp,necessary screws whrerever required complete all as specified and directed to mitigate site requirement.
All as per item No.35.00 but 75mm dia.
Cleaning of Manholes of any size and depth by pumping out or manually of sludge, water,effluent etc. and removing all loose sediment sand sludge, grit, ash, and stringly material and removal to sewage treatment plant or as directed by Engineer in charge . Note:- The cleaning work to be execute within 24 hours of receipt of complaint failing which Rs 200/day shall be recovered from the contractors final bill/RAR as decided by the GE.
Cleaning blocked WC/floor trap/Nahni trap to 1st manholes by rodding/choke remover manually as in foul condition after taking off manhole cover and placing the manhole cover in original position etc complete all as specified and directed. Note:- The cleaning work to be execute within 24 hours of receipt of complaint failing which Rs 500/day shall be recovered from the contractors final bill/RAR as decided by the GE.Contractor has to detail two labour (safai wala) daily to attend complaint at complaint cell at 9 AM who will again report to Eng-in-charge.
Cleaning of existing sewage line dia upto 300mm dia by roding including removal of sludge and pumping out sewage water where required and finally flushing with clean water from manhole to manhole any dia all as directed by Engr-in-Charge Note:- The cleaning work to be execute within 24 hours of receipt of complaint failing which Rs 500/day shall be recovered from the contractors final bill/RAR as decided by the GE.
M&L for special treatment to sunken portion with 10mm thick plaster in CM 1:4 by using Ditachment DM 1% by weight of cement and surface made smooth. After curing period, two coat of Ditachment DS shall be applied @ 2.50 Kg/Sm. The paste like consistancy is made by using 2.5 Kg of Ditachment DS powder in one litre of admixture (The admixture is made by dissolving 1 part by volume of Nafufill SBR & 4 part by volume of water). After 3 days curing, testing shall be done by flooding for 24 hours. Finally protective plaster coat of 10mm thick in CM 1:4 shall done by using Putz Ditachment 1% by weight of cement over layer of Detachment DS. All joints of CI Pipe, Nahani trap, WC connection etc. shall be filled by mixture of cement, fine sand and 10% Nafufill SBR by weight of cement. 32mm dia and 500mm long GI Spout light grade shall be provided in all sunken slabs to drain off water. Note:- work is required to be executed on top priority basis.urgency factor and extra labour cost shall be deemed to be included by contractor while quoting.Nothing extra shall be paid.
Taking up or down steel tubing and connections15 mm bore including cleaning for re fixing or removal to store Note:- work is to be done in multistorey bldgs(int and ext plumbing)
Refixing old steel tubing and connections 15mm bore in new or old position(wall,ceiling,floors,etc.) Note:- GI tubing shall be concealed wherever directed by Engr-in-charge.contractors quoted rates deems to be inclusive of the said provision.
S&F 15mm bore galvanised steel water tubes, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceiling or laid in floors. Note :- GI tubing shall be concealed wherever directed by Engr-in-charge.contractors quoted rates deems to be inclusive of the said provision.
Supplying and laying of CPVC concealed pipes 20mm outside dia pipe SDR 11 & plain CPVC SDR 11 fittings in ceiling/wall/floors complete all as specified (Internal plumbing shall be concealed)
Taking up or down steel tubing and connections 20 mm bore including cleaning for re fixing or removal to store Note:- work is to be done in multistorey bldgs(int and ext plumbing)
Refixing old steel tubing and connections 20mm bore in new or old position(wall,ceiling,floors,etc.) Note:- GI tubing shall be concealed wherever directed by Engr-in-charge.contractors quoted rates deems to be inclusive of the said provision.
S&F 20mm bore galvanised steel water tubes, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceiling or laid in floors. Note:- GI tubing shall be concealed wherever directed by Engr-in-charge.contractors quoted rates deems to be inclusive of the said provision.
Supplying and laying of CPVC concealed pipes 25mm outside dia pipe SDR 11 & plain CPVC SDR 11 fittings in ceiling/wall/floors complete all as specified(Internal plumbing shall be concealed)
S&F in repairs 15mm bore bib taps,fancy type,cast copper alloy,chromium plated with crutch or butterfly handle,screwed down,screwed for iron pipe or for brass ferrule and fixed in repair.
NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS. 23,880.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
Alpha Construction (BID ID -3277323)
Abhiraj Enterprises (BID ID -3281803)
SVT ENGINEERS AND CONTRACTOR. (BID ID -3277810)
M/S R.K.S. CONSTRUCTION (BID ID -3281406)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .