Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹5.6 L
EMD Value
₹11,298
Closing Date
14 Feb 2024, 3:00 pmClosed
Executive Engineer
Executive Engineer, CD, APWD, Diglipur
Repair and renovation of 03 Nos. Industrial Type-I Quarter Qtr No. A-9 to A-11, under Sub Division-V, Naveen Nagar. Sw- Construction of Toilet Block along with repair of compound wall in Section of JE-III, SD-IV, CD, Diglipur under Naveen Nagar
2024_APWD_13246_1
NIT No. 113/EE/CD/APWD/DP/2023-24
Open Tender
Civil Works - Buildings
Works
90 days
Under Naveen Nagar Section, Diglipur
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹11,298
14 Feb 2024
2 Feb 2024
14 Feb 2024
2 Feb 2024
14 Feb 2024
5 Feb 2024
2 Feb 2024 - 5 Feb 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth. sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Extra for addition of synthetic Polyester triangular fibre of length 12mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concreteACC/Flooring/water retaining structures by using 125gms of synthetic Polyester triangular fibre for 50 Kg cement used as per directions of Engineer-in-Charge,
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fllets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended foors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying Autoclaved Aerated concrete blocks (AAC) masonry 150mm/230mm/300 mm thick AAC with Grade-1 blocks of density 551-650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
12 mm cement plaster of mix :
1:4 (1 cement: 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade .
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required said and colour complete to give and even said.
Old work (one or more coats)
Finishing walls with Acrylic Smooth exterior paint of required shade:
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe 32 mm dia
Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
Providing and fixing floor mounted, white vitreous china single piece,double traps syphonic water closet of approved brand/make, shape,size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall
15 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
30 cm length 15 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15 mm nominal bore
Providing and laying hollow cement concrete block walling 200mm thick consisting hollow block of size 400 x 200x200mm of mix 1:3:6(1cement :3 coarse sand:6 graded stone agg. 10mm nominal down size) having a crushing strength of 3.5N/mm2 at 28 days as per I.S. 2185 (Part-I) 1979 laid in cement mortar 1:6(1cement : 6 coarse sand).
Upto floor five level
Construction of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 grade stone aggregate 20mm nominal bore) manhole, R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design:
Inside size 60x60 cm and 45 cm deep with RCC precast slab.
Providing and fixing PVC septic tank of approved design and make of size of model Type-I having inside dimensions 2500mm diameter, 750mm length with 10-15 users/flushing day by day and laying tank in position and filling inside half the tank with water, including transportation etc complete as per the direction of Engineer-in-charge.
Making soak pit filled with honey comb shaft with boulder and SW drain pipe 100mm diameter, 1.8 m long i/c earth work and CC 1:2:4 complete as per standard design.
of size 1.50x1.50x1.50 mtr
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Bend 87'5' 110 mm bend
Providing and fixing 12 mm thick WPC solid board in panelling fixed in aluminium doors, windows shutters and partition frames with C.P / stainless steel screws etc complete as per architectural drawing and direction of engineer -in - Charge.
For shutter of doors window , windows & ventilators including providing and fixing hinges/pivots and making provision for fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprence gasket required.
GOUR DAS
Rajesh Halder
GOPAL BAROI
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .