Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC | L1 | Accepted-AOC Work Awarded to L1 bidder. | |
| 2 | Rejected-Technical AT RAY COLLIERY POST CHURI DIST RANCHI 829209 | HAZARIBAGH | JHARKHAND | 829209 | - | Rejected-Technical L2 Bidder. Documents of L2 bidder not scrutinized, as bid of L1 bidder found acceptable technically and financially. | |
| 3 | Rejected-Technical | - | Rejected-Technical L3 Bidder. Douments of L3 bidder not scrutinized, as bid of L1 bidder found acceptable technically and financially. |
Tender Value
₹1.7 L
EMD Value
₹2,200
Closing Date
14 Mar 2023, 9:00 amClosed
Project Engineer (EnM), Ashok OCP, Piparwar Area
Ashok OCP, Piparwar Area Chatra, Jharkhand-829201
Wiring with Providing and Fixing of all/Lighting accessories of 02 nos of View Tower situated in mine under Ashok OCP.
2023_CCL_273526_1
PO(AK)/PE(EnM)/e-NIT/22-23/179
Open Tender
Electrical and Maintenance Works
Item Rate
6 days
Ashok OCP, Piparwar Area Chatra, Jharkhand-829201
2 documents required · 2 mandatory
₹2,200
26 Apr 2023
3 Mar 2023
15 Mar 2023
4 Mar 2023
14 Mar 2023
4 Mar 2023
4 Mar 2023 - 10 Mar 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wring for circuit/ subman wiring alongwith earth wire with 2x1.5 sqmm + 1x1.5 sqmm. FR PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply & fixing of 2+2 way, SPN, single door, MCB DB
Die-cast aluminium alloy body heat resistant prismatic glass cover bulk head luminairs with gasket Die-cast aluminium alloy body heat resistant prismatic glass cover bulk head luminairs with gasket
6 Sqmm. X2 , PVC insulated copper cable in meter
Supply of Flat panel 36W, 230V, 2'X2'
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Overhead & Profit including fixing charges on Supply items (@15% of S.No. 8 & 10)
Total impact of GST for the purpose of CTC
M/S M. S. CONSTRUCTION
M/s Rajkumar Mahto
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .