Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.6 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹4.7 L+₹4,438.97 (0.96%)Accepted-Finance | 2 | Accepted-Finance L2 | |
| 3 | 3₹4.7 L+₹11,374.79 (2.46%)Accepted-Finance | 3 | Accepted-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹9,300
Closing Date
10 Jan 2024, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO1 (Works)
HQ 6 Sector Assam Rifles
Repair of Toilet block for VC Hall of HQ 6 Sector Assam Rifles at Kashiram Basti.
2024_ARMHA_788518_1
6 Sect AR/Engr/MW/2023-24/73
Open Tender
Civil Works
Item Rate
25 days
KashiramBasti
As Per Tender Documents
2 documents required · 2 mandatory
₹500
DIG AR, 6 SECTOR AR
₹9,300
12 Jan 2024
3 Jan 2024
11 Jan 2024
3 Jan 2024
10 Jan 2024
3 Jan 2024
3 Jan 2024 - 8 Jan 2024
SCHEDULE ‘A’ PART -I
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kind soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth 1:3:6 (1 Cement : 3 coarse sand :6 graded stone aggregate 40 mm nominal size derived from natural sources).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) mix
Providing and laying in position reinforced cement concrete (1:1.5: 3 ) with 20 mm nominal size stone aggregates , excluding the cost of centering, shuttering, finishing and reinforcement , all work upto plinth level.
Providing and laying in position reinforced cement concrete (1:1.5: 3 ) with 20 mm nominal size stone aggregates , excluding the cost of centering, shuttering, finishing and reinforcement etc in Columns above plinth level.
Reinforced cement concrete work in beams, chajjas, lintels, bands, plain window sills above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and laying formwork to sides of concrete including strutting, propping etc and removal of form for foundations, footings, bases of columns etc.
Providing and laying formwork to sides of concrete including strutting, propping etc and removal of form for columns above plinth level .
Providing and laying formwork to sides of concrete including strutting, propping etc and removal of form in lintel and top beams.
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level, in Cement mortar 1:4 (1 cement :4 coarse sand).
15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand).(Internal surfaces of wall).
20 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand).(External surfaces of wall).
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Supplying, stacking and laying at site 63 mm to 45 mm size stone aggregate, spreading and compacting stone aggregate of specified sizes to floor sub base in uniform thickness, hand picking, ramming watering and compacting to the required density.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Providing and laying vitrified floor tiles in 600x600 mm sizes (thickness to be specified by the manufacturer), of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Providing and fixing false ceiling of GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) , including factory painted after bending specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Finishing walls with Acrylic Smooth exterior paint with silicone additive of required shade on new work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification (Two or more coats on new work).
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length with Second class teak wood.
Providing and fixing 35 mm thick shutters Second class teak wood panelled or panelled and glazed shutters for doors, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete of 125mm length.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete of size 250x16mm.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete of size 200x10mm.
Providing and fixing factory made steel glazed windows and ventilators, side/top/centre hung , with beading and all members such FD7,F4B,K11B etc, including providing and fining hinges, pivots, including priming coat of approved steel primer of fixing with 15x3mm lugs 10cm long embeded in cement concrete block 15x10x10cm of cement concrte (1:3:6).
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, W.C. pan with ISI marked white solid plastic seat and lid.(Make - Hindware/Parryware/Jaquor)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require, White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap (Make - Hindware/Parryware/Jaquor).
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge
Providing and fixing Brisk Health Facuet ABS with Rubbit Cleaning System 1.25m long SS Flexible Tube & BAS wall hook (Make - Hindware, Cat No.F160110).
Providing and fixing P.V.C. waste pipe for wash basin including P.V.C. waste fittings complete Flexible Pipe of 32 mm dia.
Providing and fixing mirror of superior glass (of approved quality) and of Rectangular shape 1500x450 mm with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia.
Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia.
Providing and fixing 15mm nominal bore C.P. angle stop Cock for basin mixer, flushing cistern and geyser points of approved quality (Make - Hindware, Cat No. F280004).
Providing and fixing 15 mm nominal bore 45 cm length uplasticised PVC connection pipe with brass unions .
Providing and fixing stainless steel 600 mm long towel rod with brackets fixed with CP brass screws with concealed fittings arrangement of approved quality and colour (Make - Hindware, Cat No. F580012).
Providing and fixing 15 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints in Concealed work etc.complete as per direction of Engineer in Charge.
Providing and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints for External work etc.complete as per direction of Engineer in Charge.
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing 25 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete.
Providing and fixing stainless steel toilet paper holder (Make - Hindware, Cat No. F890003) .
Providing and fixing stainless steel Pillar Cock Tall (Make - Hindware, Cat No. F360002) .
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design, Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Groub 'B')
Supplying and fixing 5/6 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 15/16 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supply and fixing brass batten/ angle holder including connection etc. as required.
Providing and fixing 32 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc.
Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp.
Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp.
Supplying and fixing 3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 6 pin 15/16 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and drawing 2x2.5 Sqm mm of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
Supply and fixing of Hand Dryer wall mounted (Model - Chronovex 1500 Watt ABS automatic.
Supply and fixing of 300 mm sweep exhaust fan plastic body with grill in the existing opening, including making good the damage, connection, testing, commissioning etc. as required (Make - Havells/Bajaj/Khaitan).
Supply and fixing of 18 Watt LED recess panel light size - 200x200 mm fixed to false ceiling, including connection to existing switch board, testing, commissioning etc complete. as required (Make - Havells).
Supply, installation, testing of 0.50 HP water pressure pump, Single Phase 240 volt of 20mm nominal dia delivery & suction pipe (Make - Crompton).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required tank Staging , including use of chequered plate wherever required, all complete
Providing and laying in position cement concrete of 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering,All work up to plinth level .
M/S ZANDI DOMTA
m/s Nagaland Tech Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .