Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹11.1 L+₹1.5 L (15.2%)Rejected-Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | L2 | Rejected-Finance BEING 2ND LOWEST | |
| 3 | L3₹12.0 L+₹2.3 L (23.9%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L3 | Rejected-Finance BEING 3RD LOWEST | |
| 4 | L4₹13.0 L+₹3.3 L (34.4%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L4 | Rejected-Finance BEING 4TH LOWEST | |
| 5 | L5₹16.5 L+₹6.9 L (71.1%)Rejected-Finance HOUSE NO 89 BEHIND DD LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L5 | Rejected-Finance BEING 5TH LOWEST |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
3 May 2021, 6:00 pmClosed
Garrison Engineer
Garrison Engineer C/O 56 APO
CERTAIN REPAIR AND MAINTENANCE OF HOT WATER BOILERS AND CONNECTED WORKS AT 21 WING AF STN LEH
2021_MES_421767_2
GEAF-41/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF LEH
As Per Tender doucments
8 documents required · 8 mandatory
₹500
GE (AF) LEH
₹36,000
Yes
9 Aug 2021
29 Mar 2021
5 May 2021
29 Mar 2021
3 May 2021
5 Apr 2021
Amount
M&L for repair of Alfa Therma /Thermax / rapid cool Make 1,00,000.00 K Cal/hr capacity water boiler which includes following :- Disconnecting electrically drain out of water opening of burner chamber, blower assembly all accessories & mounting on boiler & taking out helical coil Make : Rapid cool water generator 100000 K Cal/Hrs, cleaning of all parts with chemical agents and reassembling of the same after necessary servicing/repairing/replacement of unserviceable parts as specified in each items mentioned / directed at site including minor repair such as welding, brazing, fabrication etc and all minor items such as nuts, bolt and washer etc complete all as specified and directed by Engineer-in-Charge. Note :- Spare parts required for repair/ replacement shall be measured and paid for separately under item No 1.01 to 1.11 given below . The cost on account of fixing of spare parts is deemed to be included in these items only.
Supply only Inspection glass (gauge) suitable of Hot water boiler all as directed as specified by Engineer-in-Charge.
Supply only photocell suitable for Alfa Therm/ Rapid cool / Thermax boilder complete all as per sample all as specified & directed by Engr-in-Charge.
Supply only Input ignition transformer 220 Volts having out/input 11 KV to 14 KV suitable for Alfa Therm / Rapid Cool / Thermax boiler complete as per sample complete all as directed & specified.
Supply only Ignition electrode suitable for Alfa Therm/ Rapid cool / Thermax boilder complete all as per sample all as specified & directed by Engr-in-Charge.
Supply only Solenoed valve suitable for Alfa Therm / Rapid Cool / Thermax boiler complete all as per sample all as specified & directed by Engr-in-Charge.
Supply only Fuel filter body suitable for Alfa Therm / Rapid Cool / Thermax boiler complete all as per sample all as specified and directed by Engineer-in-Charge
Supply only Fuel filter suitable for Alfa Therm / Rapid Cool / Thermax boiler complete all as per sample all as specified and directed by Engineer-in-Charge
Supply only Fuel pump for burner suitable for Alfa Therm / Rapid Cool / Thermax boiler complete all as per sample all as specified and directed by Engineer-in-Charge
Supply only Sequence controller complete all as per sample all as specified and directed by Engineer-in-Charge
Supply only Digital temperature controller suitable for Rapid Cool / Thermax boiler complete all as per sample all as specified & directed by Engr-in-Charge.
Supply only refractory plate paste top & bottem side and including Gasket change as per sample all as specified & directed by Engr-in-Charge.
M&L for repair of burner and burner assembly of hot water generatorof Make : Alfa Therm / Rapid Cool / Thermax model including rewinding of burner, replacement of unserviceable nozzle with new one of suitable size and other connected items all as directed by Engr-in-Charge
M&L for rewinding of electric motor 5 HP 3 phase 415 with suitable size super enameled copper wire and insulation as per existing gauge and rating complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of electric motor 2/3 HP 3 phase 415 with suitable size super enameled copper wire and insulation as per existing gauge and rating complete all as specified and directed by Engr-in-Charge.
Supply and replacement of pressure jet burner assembly suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity Make : Alfa Therm / Rapid Cool / Thermax model hot water generator including all other connected items all as directed by Engr-in-Charge
M&L for repair of electrical panel of boilers including replacement of indicator lamp,switch,contactor,MCB,relay of appropirate rating etc to make electric panel fully functional completein all respects all as specified and directed by Engr-in-charge.
M & L in repair for Insulation of M S Pipe of dia 50 mm with PUF slab 30 mm thick with and including applying bituminuous compound and Aluminium cladding with 26 gauge Aluminium sheet after tightening the slabs with GI wire completeall as specified and as directed
M & L in repair for Insulation of M S Pipe of dia 40 mm with PUF slab 30 mm thick with and including applying bituminuous compound and Aluminium cladding with 26 gauge Aluminium sheet after tightening the slabs with GI wire completeall as specified and as directed
Taking down old insulation of MS water tank and M&L for insulation of Cylindrical shaped horiznatal placed with resin bonded fibre glass wool roll of density 24 kg/Cum including wire mesh with factory laminated aluminium vapour barrier, thickness of insulation 25 mm and including the following:- (a) M&L for cleaning the surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials . (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including GI wire by tightening it laterally with the insulation. (e) M&L for cladding the insulation with 26 gauge aluminium sheet including rivetting work complete. as specified and as directed by Engineer-in-charge.
Demolition of cement concrete in ground floors or mass concrete complete all as specified and directed by Engineer-in-Charge.
Pre cast cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) for motor/pipe foundation, filling and mass concrete including disconnecting the exsiting pipe/electric connection and reconnecting pipe/connection again complete all as specified and directed by Engr-in-Charge
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces 1:3 complete all as specified and directed by Engr-in-Charge
Note : Schedule of credit for Rs. 13,557.00 (Rupees Thirteen thousand five hundred fifty seven only) to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents
Hitech Erectors Pvt. Ltd.
EESSI
national engineering
M/S HIGHLAND ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .