Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 153 PKT 21 SECTOR 24 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Admitted-Finance |
| 2 | Admitted-Finance SHOP NO 55 GROUND FLOOR ROHINI SECTOR 7 NAHARPUR FLOOR HARLAL MARKET NAHARPUR SECTOR 7 DELHI OPP GOYAL GARMENTS VILLAGE TOWN DELHI CITY DELHI | Admitted-Finance |
| 3 | Not Admitted-PreQual/Technical | Not Admitted-PreQual/Technical Others-Rejected due to not fulfilling the NIT conditions |
Tender Value
₹10.5 L
EMD Value
₹21,100
Closing Date
27 Feb 2023, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EX. ENGINEER (E AND M) M-9
D BLOCK OHT OPP DESU COLONY JANAKPURI NEW DELHI-58
Improvement in Operation system of various Pumpsets installed at C-8 VasantKunj BPS.
2023_DJB_236832_19
N.I.T. No.17(2022-23)/ EE(EnM)M-9
Open Tender
Civil Works
Works
30 days
OFFICE OF THE EX. ENGINEER (E AND M) M-9
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJB EMD Ac No. 50448339804
₹21,100
4 Mar 2023
18 Feb 2023
27 Feb 2023
18 Feb 2023
27 Feb 2023
18 Feb 2023
LT Distribution panel sheet steel enclosure made out of 2 mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust & vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection. The each part of the fabricated panel will be strictly subjected to seven tank treatment and will include the following procedure. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic aluminium conductor duly sleeved with heat shrinkable PVC sleeve and shall be liberal sized. The control wiring of the panel will be done with PVC flexible copper wires of 1.5 sq. mm cross section. Each wire will be terminating with a copper ferule crimped to the wire panel size 2000x1800x350 mm. Having following components :-
MCCB 415 V, FP 3 phase high breaking capacity 50 Hz, 50 KA, 400 Amp. With spreader and handle. Make L&T/Havells/DJB approved makes.
MCCB 415 V, TP 3 phase high breaking capacity 50 Hz, 50 KA, 100-125 Amp. With spreader and handle. Make L&T/Havells/DJB approved makes.
MCCB 415 V, TP 3 phase high breaking capacity 50 Hz, 50 KA, 63 Amp. With spreader and handle. Make L&T/Havells/DJB approved makes.
MCB Single pole 6-10 Amp. Make L&T/Havells/DJB approved makes.
MCB Triple pole 63Amp. Make L&T/Havells/DJB approved makes.
MCB Triple pole 32Amp. Make L&T/Havells/DJB approved makes.
Power capacitors 415V unit of 15Kvar Make: Epcos/L&T//DJB approved makes.
Over load relay 66-110Amp.Make: L&T/Siemens/DJB approved makes.
Over load relay 6-10Amp Make: L&T/Siemens/DJB approved makes.
Digital Amp. Meter Make AE/L&T/DJB approved makes.
Digital Volt Meter0-500V -Make AE/L&T/DJB approved makes.
Motor protection Relay Make: L&T/Siemens/DJB approved makes.
Power contactor 220V 3phase110Amp. MakeL&T/Siemens/DJB approved makes.
Power contactor 220V 3phase95Amp. MakeL&T/Siemens/DJB approved makes.
Power contactor 220V 3phase18Amp. MakeL&T/Siemens/DJB approved makes.
Star delta timer on delay make: L&T/Siemens/DJB approved makes.
Indicating lights LED type RYB & On/OFF (dia. 16 mm) Make : L&T /Havells/DJB approved makes.
Current Transformer100/5 Make AE /Advance/DJB approved makes.
Current Transformer60/5Make AE /Advance/DJB approved makes.
Current Transformer30/5Make AE /Advance/DJB approved makes.
On load change over switch 200Amp. Open execution type Make:L&T/Havells//DJB approved makes.
Supply of 3X70 sq. mm PVC insulated & PVC sheathed Copper armored conductor cable. Make :-Grandley/Gloster/ICC?CCI?Universal/Havells/DJB approved makes.
Dismantling of the existing old damaged panel & starter, removing of cable connection & shifting the same from site to a safer place with the help of all tools & tackles required to complete the job with heavy manual labour, etc.
Loading, unloading by crane & heavy labour & cartage up to site
Re-dressing/Laying & making end termination of both incoming &out going side of cable with brass compressed cable gland, thimbling on removable cable gland plate.
Installation fixing of new panel with all electrical and mechanical connection with proper thumbing tapping & connection of cable with motor. Making foundation with M.S. angle & channel, grouting and required civil work for proper foundation
Testing & commissioning of the panel & other accessories with relevant IS as follow: - Check equipment’s specification - Continuity and ear thing -MCCB mechanism and alignment -Meggaring of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests -Checking for all tightness of nuts and bolts -Alignments of doors etc. -interlocking tests
ARIHANT ENGINEERS AND TRADERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .