Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | L1 | Accepted-AOC accepted | |
| 2 | L2₹19.3 L+₹49,343 (2.63%)Rejected-AOC PLOT NO 117 UTTAM NAGAR NEAR AADHAR HOSPITAL TOSHAM ROAD HISAR 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-AOC rejected | |
| 3 | L3₹19.8 L+₹99,514 (5.30%)Rejected-AOC | L3 | Rejected-AOC rejected | |
| 4 | L4₹20.6 L+₹1.8 L (9.69%)Rejected-AOC | L4 | Rejected-AOC rejected | |
| 5 | L5₹22.5 L+₹3.7 L (19.9%)Rejected-AOC | L5 | Rejected-AOC rejected |
Tender Value
₹16.8 L
EMD Value
₹33,580
Closing Date
5 Aug 2022, 5:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Br. Rohtak
Construction of 8 Nos. Transit Flats and 2 Nos. Residence of Revenue Officers at Alewa in distt. Jind (CM Announcement code No. 20720 dated 19.01.2020) (Pdg. E.I. only). Recall
2022_HRY_231405_1
PWD/Electrical/123345
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Rohtak
Please refer to tender documents as per DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹33,580
Yes
27 Jan 2023
22 Jul 2022
8 Aug 2022
22 Jul 2022
5 Aug 2022
22 Jul 2022
Amount
HSR Items
Ceiling Fan / Exhaust Fan
20.71 Supply, Erection, Testing of Ceiling Fan IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-Charge
20.72 Supply, Erection, Testing of Exhaust Fan IS marked (as per IS code 374)having a capacity of 45 cubic meter per minute complete with suitable GI sheet ducting in structure confirming to latest IS specifications complete in all respects complete to satisfaction of Engineer-in-Charge
23.2 Copper Wiring with Modular Switches in MS Conduits
23.2.1 Wiring for Light / Fan / Call Bell point with Modular Type Switch / Socket and GI Box, Modular Type Face Plate ect. in 1.5 Sqmm FRLS PVC insulated Copper Conductor Cable in 1.6 mm thick MS Conduit Pipe
23.2.1.1 Group A
23.2.2 Wiring for Twin Control Light Point with 2 Nos., 2-ways 5 Amp. modular Switch GI Box and Modular Face Plate in 1.5 Sqmm FRLS PVC insulated Copper Conductor Cable in 1.6 mm thick MS Conduit Pipe
23.2.2.1 Group A
23.2.4 Wiring in MS conduit System for 3 pin 5 amp. plug point by using 2 Nos. 1.5 sqmm FRLS copper wire and 1 No. 1.5 Sqmm FRLS Copper wire including providing 1 No. 5/6 Amp 3/5 pin Modular Type Socket and 1 No. 5/6 Amp Modular type Switch required GI Box, Modular Face Plate etc. complete as required.
23.2.4.1 Group A
23.2.5 Wiring in MS conduit system for 3 pin 15 amp. plug point by using 2 Nos. 4 Sqmm FRLS copper wire for earthing, including providing 1 No. 15/16 Amp 3/6 pin Modular Socket and 1 No. 15/16 Amp Modular Switch required GI Box, Modular Face Plate etc. complete as required
23.2.5.1 Group A
23.1.6 Wiring main sub mains and circuit wiring in Two single core for phase and neutral wire and one single core for each wire PVC insulated copper conductor cable 1100 volts grade in MS conduit etc complete as required
23.1.6.1 1 run of size 1.50 Sqmm (1/1.40 mm)
23.1.6.3 1 run of size 4 Sqmm (1/2.24 mm)
23.1.6.4 1 run of size 6 Sqmm (1/2.80 mm)
23.6.6 Supply and Erection of MS conduit pipe 1.6 mm thick, ISI marked surface / recessed in slab / wall / ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work
23.6.6.1 M S Pipe of 20 mm dia
23.6.6.2 M S Pipe of 25 mm dia
23.7.6 Supply and erection of PVC Conduit ISI mmarked (Medium) recessd in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work.
23.7.6.2 PVC pipe of 25 mm dia
23.8 Fittings and Accessories.
23.8.1 Providing and fixing Paino type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connection, complete in all respect
23.8.1.6 Call bell 220/230 volts musical type
23.8.1.12 Bakelite angle / straight button holder large size.
23.8.4 Supply and erection of 10.5 cm dia MS Fan box including 8 mm dia 30 cm long MS road made into suitable suspension hook and erected in RCC slab for the erection of fan complete with all labour and material required to complete the job
23.8.10 Providing and fixing GI Concealed Sheet Metal Boxes with Inner and Outer Face Plate including concealing the box in wall and fixing in position with Inner Plate and Face Plate with all labour and material required for the job complete in all respect
23.8.10.1 1 & 2 Modules including combined plate for Telephone and Data
23.8.10.2 3 Modules
23.8.10.3 4 Modules
23.8.10.4 6 Modules
23.8.10.5 8 Modules
23.8.10.6 12 Modules
23.8.11 Providing and fixing Modular Type Accessories of approved make in existing box including fixing and making necessary connections, complete in all respect
23.8.11.6 Bell Push
23.8.11.7 Step Type Fan Regulator 2 Modules 300 Watt
23.8.11.8 Telephone Socket Outlet Modular Type
23.8.11.9 TV Socket Outlet Modular Type
23.9 Erection of Exhaust fan in existing opening, complete with necessary earthing of Fan including carriage from PWD store to the site of work.
23.11 Making suitable hole in the wall suitable for exhaust fan upto 450 mm sweep including finishing the same and fixing of stainless steel wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required.
23.22 MCCB, Distribution Boards, MCB's, RCCB's, Change Over etc.
23.22.1 Supply and erection of modular case circuit breaker single pole / 4 pole on existing wall / pedestal / panel including bounding to earth and making necessary connections required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work.
23.22.1.3 Triple Pole MCCB 16 to 100 Amp., 25 KA
23.22.2 MCCB enclosure made of sheet steel suitable for mounting MCCB of following ratings
23.22.2.1 MCCB upto 125 A FP
23.22.3 MCCB enclosure made of sheet steel suitable for mounting MCCB of following ratings
23.22.3.2 SPN OR DP enclosure suitable for DP MCB
23.22.4 Supply and erection of double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.
23.22.4.5 TPN DB Horizontal type Double Door 4 way (8 incoming and 3 phase * 4 outgoing)
23.22.4.11 Vertical TPN DB Double Door 8 Way (8 incoming 3 phase*8outgoing)
23.22.5 Supply and erection of miniature circuit breaker 240/ 415 V in the existing distribution board including making necessary connections
23.22.5.1 6 Amp. to 32 Amp. Single Pole
24.1 Earthing and Lightening Arrestor
24.1.1 Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. (but without charcoal or coke and salt) as required
24.1.2 Extra for using salt and charcoal/coke for earth electrode as required.
24.1.11 Providing and laying earth connections from earth electrode with 4.00 mm dia GI wire in 15 mm dia GI pipe from earth electrode as required.
M.R. Items
NS-1 S/E of underground cable loose in existing pipe or trenches complete in all respect upto the entire satisfation of Engineer-in-Charge of the work. Make: RR/Polycab/Havells
i) 25 Sqmm 4 Core Cable (Armd.)
NS-2 Supply and Erection of LED Tube fitting with all accessories as supplied by the manufacturer complete in all respect. Make: Philips/Wipro/Bajaj
i) LED Tube Light Fitting 18 W
ii) LED Tube Light Fitting 40 W
Rajesh Electric Works
Raghbir Sarup Govt.Cont.
NAVEEN LIGHT AND SOUND SERVICE
G.B. Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .