Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹75.2 LAdmitted-Finance VILLAGE DHANI DULAT DISTT FATEHABAD VILLAGE TIBBI DHANI DULAT DISTT FATEHABAD 125106 | FATEHABAD | FATEHABAD | HARYANA | 125106 | L1 | Admitted-Finance | ||
| 2 | L2₹78.7 L+₹3.5 L (4.67%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹79.4 L+₹4.2 L (5.61%)Admitted-Finance HARYANA HR | L3 | Admitted-Finance | ||
| 4 | Not Admitted-Fee/PreQual/Technical SATISH KIR YANA STORE BARWALA DAULATPUR ROAD BARWALA 125121 | BARWALA | HISAR | HARYANA | 125121 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | ||
| 5 | Not Admitted-Fee/PreQual/Technical N A | PALWAL | HARYANA | 121004 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹70.3 L
EMD Value
₹1.4 L
Closing Date
20 Apr 2026, 5:00 pmClosed
RAKESH
Municipal Council Fatehabad
const of CC street from H/o Dr mahander to ravi narula , labha kamboj to jeet biljiwala tobabu house to hanuman mandir , harjit sarpanch to santa , makhan chai wala to balbir canductor and comunity center to mushalman in ward no 1 MC Fatehabad
2026_HRY_512286_1
20261398DF42 D240 49BE 9E51 6D91C2A83C77272ULB
Open Tender
Civil Works
Works
230 days
Fatehabad
Civil Work 1st Time tender
2 documents required · 2 mandatory
₹5,000
₹1.4 L
Yes
28 Sept 2026
1 Apr 2026
21 Apr 2026
1 Apr 2026
20 Apr 2026
1 Apr 2026
1 Apr 2026 - 3 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | [10.17]Providing and laying polythene sheet under CC M-25 in road and parking complete in all respect [Through Rate] | - | Sqm | - | - |
| 2 | [17.5.3]Compacting Original Ground 3. Compaction of Earthwork
Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications [Through Rate] | - | Sqm | - | - |
| 3 | [17.70]Removal of existing IPB by manual means and disposal of dismantled material with all lead and lift as per technical specification clause 202.3. [Through Rate] | - | Sqm | - | - |
| 4 | [21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping [Through Rate] | - | Each | - | - |
| 5 | [21.93.1]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening [Through Rate] | - | Each | - | - |
| 6 | [5.23.2]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 2. Nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) [Through Rate] | - | cum | - | - |
| 7 | [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] | - | cum | - | - |
| 8 | [6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) [Through Rate] | - | cum | - | - |
| 9 | [6.58]Providing and fixing in position 12mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. [Through Rate] | - | Per cm depth per 100m | - | - |
| 10 | [9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter [Through Rate] | - | Metre | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_591094.xls
BOQ • 0.24 MB
AD0157224.pdf
Additional Documents • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .