Supply, Installation, Testing and Commissioning of Signalling material in connection with:-Automatic block signaling in Asloda-Ujjain, Ujjain-Karchha and Ujjain-Tajpur section of Ratlam divison.
SnT_RTM_W_25_18~WR
SnT_RTM_W_25_18
Open
Works - General
24 Months
Ujjain, Madhya Pradesh
₹0
₹31.2 L
13 Feb 2026
22 Jan 2026
30 Jan 2026
Item Breakup - SOR-SOR Schedule
120.00 mm Dia, 4.6 Mtr Length as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). Supply Color Light Signal Accessories.
120.00 Drg no CSTE Drg No CSTE/6186.
40.00 made of tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal post as per Drawing No SW/554/G/R.
120.00 signal housing multi-unit type for railway signalling suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per RDSO Drg.No. SA 23001/A/M Adv. Alt- Sand as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. RATLAM DIVISION-S AND T/WESTERN RLY
703.00 Axle Counter (MSDAC) for Point (DP) mentioned detection Point by the purchased & track Section as per SIP, complete with all accessories, cable required with each track device & card viz. Axle detectors, Track Side Electronics/DAC field units, Central Evaluator (Central Evaluator unit should be housed in a pre-fabricated rack to be supplied along with the system), reset unit, Relay unit, Event Logger & Diagnostic terminals, etc. Required for different Detection Points & Track Sections as per RDSO Specifications No. RDSO/SPN/176/2013, Ver.3 or latest and OEM/ manufacturer's specification and as per Annexures. (Quantity 01 No. = 01 DP) Inspection Authority: RDSO. Note:- As per WR's Policy No 03/2024 Para No. 3.4.2 .e .iv "VDU/Reset box can be used for resetting. At Stations having more than 10 Track sections, the Railway propose to use a separate VDU-based resetting system. Such a VDU-based system if using a PC, it must be industrial grade".
4.00 Axle Counter (Multi section/Single section). (MSDAC comply to the RDSO spec. No. RDSO/SPN/176/2013/Ver.3 or latest and manufacturer's specification and SSDAC comply to the RDSO/SPN/177/2012,Ver.3 or latest respectively). The tool kit shall be minimum equipped with the following equipments: (i) All mechanical tools shall be of reputed make like Taparia/Bosch etc. (ii) Digital multimeter true RMS type of make Fluke 189 or similar reputed make with probe set - 1 No. (iii) Adjustable torque wrenches 25-135 N/mtr with 13 mm and 19 mm inserts- 1 set (iv) Set of spanners screw drivers and soldering iron - 1 set (v) Dummy wheel - 1 No. (vi) Marking Jig - 1 No. (vii) Adapter card - 1 No. (viii) Extended wired socket to interface with diag No. stic plug - 1 No. (viii) Selector switch on panel base - 1 No. (ix) DAC EC card puller etc.
50.00 Neutral Line, Non AC Immunized Relay, Style QN1, 24 V DC, 8F- 8B/12F-4BContact, Code ABCDF/ABCDE Spec: BRS: 930; IRS S 34; IRS S 23. RATLAM DIVISION-S AND T/WESTERN RLY
287.00 Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F- 8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78.
794.00 (QSA3), AC immune, DC neutral line 24V, 12F/4B contacts, complete with plug board, retaining clip and connectors. Conforming to BRS930A, (as applicable) IRS: S34& IRS: S23 or latest
of immunized relay 24V DC, 4F- 4B/6F-2B contacts, along with plug board, retaining clip and connectors. Conforming to BRS: 960, IRS: S60, IRS: S34 & IRS: S23. (No of each configuration will be decided by Engineer In- charge).
2.00 delay device mounted on Q series relay base and cover with fixed timing of 60/120 second confirming to IRS:S:61/2000(ver.1.0) (Amdt. 3) or Latest,IRS:S:34 and IRS:S:23 (as applicable). The Interlocking code for this unit shall be AFGKY.
4.00 DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement.
14.00 with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028 .[Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items as Annexure.)
18.00 Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8- way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated. RATLAM DIVISION-S AND T/WESTERN RLY
30.00 for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments
Terminal Screw less type, 4-wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply.
of 2.5mm/0.091 in thick as per site requirement.
of 10mm/0.0394 in width as per site requirement.
299.00 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement.
1440.00 single potential through screw less terminal block for 6 Sq.mm - 35 Sq.mm , 4 connection points 284-621/624 or superior, suitable for power cable connection.
24.00 Telephone as per spec No IRS/TC-79/2000 or with latest amendments.
CO2 (capacity 5 kg). ( co2 type4.5 kg )
Free Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. RATLAM DIVISION-S AND T/WESTERN RLY
31200.00 made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.
30.00 Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply.
126.00 Grade SS 304 of size as per Drg. No. DRM/SG/948 dt. 26.04.2011 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply.
168.00 Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8
1.80 multi-core Indoor Cable 60core x 0.6mm Dia conforming to IRS:76/89 (Amd3) or latest.
insulated Signaling multi-core Indoor Cable 1mm x 24 mm x 1 mm Dia conforming to IRS:76/89(Amd3) or latest.
1.80 multi-core Indoor Cable 1 mm x 40 mm x 0.6mm Dia conforming toIRS:76/89(Amd3) or latest.
6.00 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest.
3.00 multi-strand copper conductors cross section 1x6 Sq.mm.( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest.
3.00 multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. RATLAM DIVISION-S AND T/WESTERN RLY
3.00 multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89.
32000.00 of size width 240/340 mm, height 155/230 internal/external, length 1meter produced of polyolefin with fire protection class K-1 in accordance with DIN 53438 Part-II for laying signaling/telecom cables, channel attachable to each other with male female swallow tail connectors and having a suitable detachable cover, as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications. ( Technical specification1.96 )
Walled (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color - Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer.
300.00 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.
6.00 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 seconds or Superior. RATLAM DIVISION-S AND T/WESTERN RLY
2.00 1387100.00 cable route tracer with 10W, 500mA, 85V transmitter suitable for detecting & mapping underground cables with accuracy which can up to 3-5 cm or better, with current direction up/down arrows, Remote calibration check feature. Supply shall include inbuilt RTK enabled receiver, transmitter, compatible dual Bluetooth android phone with RTK mobile application pre- installed in android device along with minimum 5 years subscription, compatible with NTRIP andRTCMv3.X messaging standards and holder & standard accessories. Make/Model: Radio detection RD8200GS or similar. Total 329002192.02 Item- 2 B1- Execution items. S No. Item No Description of Item Unit Qty Rate Amount Supply, Installation and Commissioning of EI VDU (Visual Display Unit, 4K with all suitable accessories Compatible to El Interlocking in Safe Mode 24x7 at controlling station. The item must comply minimum following specification:- a) Screen Size ( D i a g o n a l ) : - As below b) Resolution :- 4K c) Viewing angle degree: - 178x178 degree d) Brightness :- 500 Nits e) contrast ratio 4000:1 f) Backlit :- Direct LED g) Jack Interface: - HDMI -3 no. 1.2 DP, DVI USB 2.0 -2 no. CI Slot RF In AV In Component In (RCA5 Type) Digital Audio Out RGB In (D-sub 15pin)-PC PC Audio Input RS232C (D-Sub 9pin) RJ45 Stereo mini jack. h) Optical Out :- Available Note: - Screen size will be decided as per instruction of engineer incharge.
Screen inch RATLAM DIVISION-S AND T/WESTERN RLY
and Modular power supply arrangement for VDU and industrial PC (Embedded PC) with input and output redundancy arrangement and Hot pluggable Modules as per RDSO specification. Make Gallant or similar. One set consists of 1. Input O- ring diode module with potential free -1 No contacts (PFC) for two 110 V DC sources from IPS and single 110 VDC bus Qty 1 No. 2. Isolated Inverters (Master / slave) - Input-110 V DC Output: 120 V AC/220V A500VA - 02 Nos. 3. Isolated DC-DC convertors- Input : 110 v DC Output : 24 V DC/ 10A,Qty -10No.s 4. 3 U SS rack with back panel mother board /front panel power connectors inverter auto change over switch and all required over switch and all required protection circuits (3U height for main rack 132.5mm +/-10% & 1U height for mounting 44.5mm +/- 10%) Qty - 1 No. Make Gallant or similar.
& Industrial Grade Embedded PC as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 or latest. Installation, wiring, programming, testing and commissioning of EI equipment supplied as per supply item in schedule 'A' including transportation from Consignee's depot to site. The works and materials for installation, wiring, testing and commissioning, grouting, cutting of floors, walls, refilling of the same, re- plastering, required CC/ masonry works, fixing/ placing/ laying of insulated ladders/ casing-capping/ cable trays/ RCC/GI pipes / Cables, termination of cables with lugs/ connectors, painting, / lettering are to be provided/ done by the contractor for the equipments supplied vide Item of Schedule "A" of this contract. This also covers the networking of built in EI Data loggers of all the stations to monitor the system to any other places where desired by Engineer-in-charge. Note: Installation shall be comply with RDSO Technical Advisory Note No STE/E/TAN/3012 dtd. 28.08.2014 or latest. Installation, wiring, programming, testing and commissioning of Operator VDU in Hot stand-by with Redundancy. Any Equipments/cards/Modules RATLAM DIVISION-S AND T/WESTERN RLY required for Hot stand-by with Redundancy shall be supplied & Installed by the Contractor. This also include supply of one no Godrej make operator chair model PCH7001 or better , one no. of composite computer & printer table (Godrej work station table or better) for keeping MT , one no Godrej make operator chair model PCH7001 or better. Termination of indoor/ PIJF cables in relay room on relays, tag blocks, CT racks as per approved wiring diagram including alterations/ modifications as required at site. Soldering to be done at all required termination. Dressing/ lacing of wiring shall be done neatly with help of dressing thread / plastic self-lock strip of suitable size. The tools/ equipments/ materials/ simulation boards required for testing shall be supplied / fabricated by contactor. This included replacement of modules/ cards/ LEDs/ equipments going defective during testing. Necessary power supply boards with required capacity plugs, sockets, surge & lightning protection boxes shall be supplied and installed by the contractor. 230V supply shall be arranged by Railways. In case supplies are required to be extended, from Power room / relay room then same shall be extended by the contractor with his own materials such as 1X16 sq. mm wires, cables, lugs, RCC/GI pipes, insulated ladders etc. After ST/LT testing, Factory Acceptance Tests (FAT) & Square Sheet testing system should be fault free while submitting to Railways, otherwise suitable necessary action can be taken by Engineer-in-charge
Station RATLAM DIVISION-S AND T/WESTERN RLY
120.00 (SAT) of PI/RRI/IBS /Auto signal etc. as per Selection table, control table etc. Contractor shall depute one Engineer, one Supervisor & wiremen technically qualified to carry out functional testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer incharge before permitting them to do the testing. Contractor has to note down all the discrepancies found in testing noted during functional test in a separate design register and to be counter signed by Railways representative. Rectification of circuit discrepancies to be done after taking approval of changes in circuit diagrams by Railways. Mistakes found to be rectified free of cost by contractor. Omission in testing or wrong testing found after functional test will be penalized @ 5% pf rate per route.
6.00 racks and Power equipment etc. to be done along with the supply of all requisite materials. Earthing shall be in the form of Ring Earth conforming to RDSO specification No. RDSO/SPN/197/2008 (with a min. of 6 maintenance free earth electrodes) & RDSO Drawing issued under Railway Board letter No. 2010/Sig./SGF/EI (Ansaldo) Dated 22.06.11, made using copper rings with earth resistance less than 1 ohm. The earthing shall be maintenance free & earth enhancement compound should be used. The ring earth shall be connected to copper flat of size 25x3 mm in the relay room and IPS room. This copper flat shall be fixed on the wall to the entire breadth of the Relay room and IPS room as an earth bus bar and all earth connections shall be taken from it. A, B, C, & D class protection shall be provided for all EI equipment. Note: - This will also cover the earthing& necessary protection of EI equipment as per details given in the scope of work of Special Condition of Contract and other requirement given in Chapter of tender document & Pre-commissioning check list of EI system. RATLAM DIVISION-S AND T/WESTERN RLY Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material / connectors / fuses / communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/ LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTO CAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied.
7.00 3134490.99 from 11 up to 20 routes.
32.00 Design of ST/LT/TOC/Square sheet/RCC (Three copy) for approval.
Set Design of Miscellaneous diagram consist of Floor Plan of Relay Room , Battery Room, Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Power panel diagram, IPS wiring diagram , Auto change over diagram , Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings (Three copy) for approval.
Station Supply of Circuit Diagrams consisting wiring/Logic diagram, contact analysis, fuse detail, Input/output bit chart, VDU diagram, Interface in AutoCAD in Pen Drive and Six set of Copies after approval
Station RATLAM DIVISION-S AND T/WESTERN RLY Supply of diagrams consist of Floor Plan of Relay Room, Battery Room, Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Power panel diagram, IPS wiring diagram, Auto change over diagram, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawing in original tracing along with AutoCAD in Pen Drive and six set copies after approval.
Station Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards.
Numbers Preparation of Cable Route Plan of buried S & T Cables using Radio Detector 8200 GS or Similar model GPS Model and DGPS for Per Trench per Km. For existing cables as per the instruction of Engineer in- charge. Submission of report in KMZ file format, Soft Copy Only. (Unit = Per Trench KM)
Kilometre Foundation, Erection & Installation of CLS without route indicator. RATLAM DIVISION-S AND T/WESTERN RLY
120.00 and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any... The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In- Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted directly on signal post
190.00 Marker (Drg No. CSTE/6180), 'AG' Marker (Drg No. CSTE/6181), 'P' Marker (Drg No. CSTE/6182), Arrow Marker (Drg No. CSTE/6183), 'G' Marker (Drg No. CSTE/6184), 'C' Marker (Drg No. CSTE/6185). Marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor.
26.00 screen of expanded metal 12SWG of Size 1200 X 1500 mm on Signaling as per standard practice for protecting against voltage in AC Traction area as per instruction of Engineer Incharge.
703.00 (double rail contact) including Point (DP) digging of trench, track crossing, laying of anti-rodent, anti-oxidant & non-flame propagating type Double Walled Corrugated (DWC) pipe as per IS- 14930 part- I or II or latest and all other accessories as per site requirement to be for laying of transmitter and receiver cable. The item also includes installation of EJB / Track side Electronics including foundation & earthing as per OEM's guidelines and Technical requirement & specification with their own material. NOTE: Installation / programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorized representative of OEM. RATLAM DIVISION-S AND T/WESTERN RLY
40.00 of axle Counter, wiring from CT rack to Central Evaluator, installation and wiring of the reset box, LV box (if required) and associated power supply wiring. This includes supply of shielded cable of required conductor size for wiring between CT rack to evaluator rack, all other wires, power supply cable and wiring materials. The power supply cable from power room to Central Evaluator should not be less than 10 sq.mm PVC wire. Earthing as per OEM's guidelines & specification with their own material. This also includes painting and writing work on evaluator as per site requirement. NOTE: Installation /programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/ RDSO preferably by Authorised representative of OEM.
1233.00 relays for GPR Circuit in apparatus case as per Standard practice. Fixing and wiring material shall be supplied by the contactor.
4.00 this includes supply of MS sheet box for fixing of KLCR relay along with push button etc. (KLCR will be supplied by Railway).
of Assembly including IDF pillars if any complete with wall supports, scaffolding, ladders, runway for cables, fixing of Relay / Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on WR & the instructions of Rly engineer at site.
18.00 Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly engineer at site. RATLAM DIVISION-S AND T/WESTERN RLY
20869.00 circuit diagrams in the relay racks/IDF rack tag blocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid &correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder resin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways.
30.00 commissioning of Fuse changeover system (FACS). This includes the provision of a common Buzzer & indication at the ASM Room & ESM Duty Room and the painting of fuse details. This also includes the fabrication of a frame for the installation of FACS at the Station/ LC gate where the installation of relay racks is not feasible.
20.00 Block section limit Board, goods warning board and all other boards with contractors own material. The work shall be done as per instruction of Rly. Engineer incharge as per IRSEM.
120.00 including MS flat for clamp etc. and connection to signalling equipments, lever frames, apparatus cases, signal, relay rack, block instrument, etc. as per technical specification given. This item includes digging of pit in earth 3 M deep & fixing earth electrode pipe, casting of cement concrete enclosure & cover as per RDSO/SPN/ 197/2016.Soiltreatment to be done as per std. practice. This item includes provision of MS Flat, Earth lead wires and Soldering of lead wires. The other end of the wire is to be connected to block equipment, power equipment, cable sheath, and signals etc. as per site requirements. 7strand GI wire shall be used as earth lead wire. Supply of earth electrode is covered in other Item').
168.00 Earth Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008. RATLAM DIVISION-S AND T/WESTERN RLY
60.00 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.
60.00 miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).
in embankment, guide bunds, around buried type abutments, bridge gaps, trolley refuges, rain bunds if provided, platforms etc. with earth excavated from outside railway boundary entirely arranged by the contractor at his own cost as per RDSO's latest guidelines and specifications and special condition of contract including all leads, royalty, lifts, ascents, descents, crossing of nallahs or any other obstructions. The rates shall include all dressing of bank to final profile, demarcation and setting out of profile, site clearance, removing of shrubs, roots of vegetation growth, heavy grass, benching of existing slope of old bank, all handling/re-handling. Taxes, Octroi and royalty etc. as a complete job. Cut trees shall be property of railways and to be deposited in the railway godown unless specified otherwise in the Special conditions of contract.
36.00 existing Signaling Gears. One Signalling gear will be all parts of one signal (consisting of CLS unit, Signal post along with base) or lever frame (5 levers set), or one point (consisting of all parts of a mechanical point, point machine, ground connections etc.) or one track circuits (consisting of battery box & other parts of DC Track circuit / AFTC /DAC) or one Block instruments or One Lifting Barrier or One Location Box etc. .This includes the cost of transportation of release materials to store depot or as decided by consignee in charge. This work to be done by contactors with his own vehicle and labour. (Per unit means Per Gear). RATLAM DIVISION-S AND T/WESTERN RLY Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost
126.00 748 or CSTE/5074 or SS Location
30.00 747or CSTE/5074 or SS Location. Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway.
Numbers Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Note: SMC sheet will be taken in place of phenolic laminated sheet.
and location box board on 03 mm ACP sheet with size 12 x 18 size A3 for location box including pasting of printed/ painted vinyl sheet and lamination (printing/painting of location detail on vinyl sheet covered in schedule item separately). RATLAM DIVISION-S AND T/WESTERN RLY
20.00 boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only.
20.00 boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only.
3000.00 cable channel (Injection Moulded Plastic cable Duct) of size width 100/200 mm, height 155/230 internal/external, length 1 meter produced of polyolefin with fire, protection class K-1 in accordance with DIN 53438 part all for laying signaling/telecom cables, channel attachable to each other with male female swallowtail connectors and having suitable detachable cover including supply of all fixing materials like Brackets, etc. , as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications. ( Technical specification 1.96 ) RATLAM DIVISION-S AND T/WESTERN RLY
9600.00 per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
300.00 from rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No. CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed.
90.00 Deep and 0.3 Mtr. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.
direction Metre drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge. Note: HDPE pipe supply is taken as separate i t e m . This item also includes cable laying (HDD boring). RATLAM DIVISION-S AND T/WESTERN RLY
of (min2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter.
517.00 with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.)
300.00 class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm Dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fi Xing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The e laying and fi Xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest.
523000.00 cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P. (Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
2376.00 cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker. Total 136775125.44 Item- 3 A2 Supply Items for LC gate interlocking. S No. Item No Description of Item Unit Qty Rate Amount RATLAM DIVISION-S AND T/WESTERN RLY
Color Accessories. ( Main Signal Post Tubular 140 mm Dia,5.6 Mtr Length as per IRS: S-6/81 or Latest )
4.00 signal housing multi-unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.
60.00 Neutral Line, Non AC Immunized Relay, Style QN1, 24 V DC, 8F- 8B/12F-4BContact, Code ABCDF/ABCDE Spec: BRS: 930; IRS S 34; IRS S 23.
20.00 Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F- 8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78.
10.00 style "QNA1K" ACI DC Neutral line, 24V DC 1000 Ohms 6F.6B contacts, front contacts metal to carbon and back contacts metal to carbon. Complete with plug board, retaining clip and connectors confirming to IRS: S34, IRS: S23, BRS931A. As per RDSO Specification No. STS/E/Relays/UEA (PI) Dt.30/05/97. Annexure II. The interlocking pin code CDEKY.
24.00 type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/2002, BRS: 941A, IRS: S34 and IRS: S23 (as applicable).
8.00 DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement.
2.00 device for Railway Signaling operate on 24V DC/110V AC (as per site requirement) with over voltage protection 50-60 flashes per minute and as per RDSO specification No. RDSO/SPN/173/2002 (Amd. 1) or Latest. RATLAM DIVISION-S AND T/WESTERN RLY
2.00 with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028 .[Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items as Annexure.)
2.00 Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8- way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated.
100.00 G type fuse base/holder of capacity 0.63 A - 3.0 A. (System, Rapid, Malnad or RBCO make or similar).
80.00 holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar).
50.00 PBT as per RDSO Drg No SA- 23748 Alt 4 & Spec No IRS S 75/2006 with the latest amendment. The fuse block shall be suitable for round-head type voltage fuses. This also includes the supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92.
head deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity.
2.00 for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card.
4.00 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. RATLAM DIVISION-S AND T/WESTERN RLY
Operated Barrier complete set suitable for 110VDC/24V DC supply with hand generator back up & motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 with the latest amendment. One set consisting of 02 No.s of Barriers of length 09.76 Mtr. along with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2.
2.00 Boom barrier assembly 11 to 12 Meter Long, movement drive mechanism, resetting & supporting stand suitable for Mechanical/ Electrical level crossing gate as an emergency arrangement as per Drg.
2.00 gate as per circuit design Total 2297022.46 Item- 4 B 2 Execution Items for LC gate interlocking. S No. Item No Description of Item Unit Qty Rate Amount Foundation, Erection & Installation of CLS without route indicator.
4.00 foundation for main signal post as per CSTE/3122 (WR) with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost.
4.00 and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any... The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In- Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted directly on signal post RATLAM DIVISION-S AND T/WESTERN RLY
4.00 boxes appropriate size in field / in location boxes / in SM office / at LC gate as per site condition. It should be made of Hylam /wooden (teak wood) of high quality as per requirement. Item includes supply of any minor bracket nuts, bolts and hole drilling MS angle, MS plate etc. It also includes fixing of KLCR relays in the boxes. Prior approval to be taken from Engg. In charge before supply of box.
of Assembly including IDF pillars if any complete with wall supports, scaffolding, ladders, runway for cables, fixing of Relay / Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on WR & the instructions of Rly engineer at site.
2.00 Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly engineer at site.
2.00 commissioning of Fuse changeover system (FACS). This includes the provision of a common Buzzer & indication at the ASM Room & ESM Duty Room and the painting of fuse details. This also includes the fabrication of a frame for the installation of FACS at the Station/ LC gate where the installation of relay racks is not feasible.
testing commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc.
2.00 ratio of 1:3:6 for sliding boom as per Drg. Minimum 10 No.s of foundation per set shall be cast using standard size holding down bolts & nuts for erection. Item include excavation, ramming, curing and plastering 1:4 cement and sand mixture. Aggregate, cement, sand and holding down bolts & nuts to be supplied by the contactor. RATLAM DIVISION-S AND T/WESTERN RLY
2.00 Sliding booms with E type lock and KLCR. This includes wiring of KLCR, running of cables, necessary, painting & transportation of materials from store to site. All material required to commissioning of slide booms on gate will be supplied by the contactor.
4.00 flasher arrangement 25W horn, ( Make of any ISI approved firm) working voltage as per circuit design. Installation, Wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 8mm thick SMC sheets or any standard make with connections suitable for 32 A. Wiring to be done considering site requirement, depending upon the load with suitable wires, lugs & glands as per instructions of Engineer-in-charge. The work includes installation of ELD's, fixing & wiring of change over switch(program switch) for selection of DG set supply (DG1 & DG2) and wiring of change over switch (program switch) for selection of mains or DG supply. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room etc. Any masonry work required will be carried out by contactors own material.
Numbers Total 427985.74
Item Breakup - XS1-NS Schedule
PVC insulated Railway Signaling Kilometre Indoor Single corewire conforming to IRS 76/89 (Amd3) or latest. Note:- Wire Colours shall be decided by engineer - in -Charge." (i)1 x 0.6 mm
PVC insulated Railway Signaling Kilometre Indoor Single corewire conforming to IRS 76/89 (Amd3) or latest. Note:- Wire Colours shall be decided by engineer - in -Charge (ii)1 x 1 mm RATLAM DIVISION-S AND T/WESTERN RLY
Provision of Printed PVC Vinyl Numbers Ferrule (up to 5mmDia) / custom label size of 50MM with thermal printfor CTR / Location Box and Junction Box (Color codingand With at least 300dpi print resolution, Ferrulecounting as approved & details provided by Railway)Colour of Ferrule: WHITE, BLACK, RED, LEMONYELLOW, GREEN, SKY BLUE, NEVY BLUE, ORANGE.FONT Colour: WHITE, BLACK, RED.
Supply of Micro Processor based Numbers Data Logger Systemwith 512 digital inputs and 32 analog inputs withprotocol converter as per RDSO Spec. No. IRS (S)99/2006 (Amnd. 3) or latest. It includes supply of allthe items required for complete indoor relay roomwiring from data logger to relay rack tag blocks,drawing/ extension of power supply up to DataLogger. It includes relay room door lock checkingarrangement, commercial power supply monitoringarrangement & monitoring of DG sets, ELD, IPS,UFSBI, ELD, MSDAC etc., interlinking and networkingof Data logger, interfacing with EI. Note: Totalnumbers of relays and other Signallingfunctions/gears required to be wired as per listcirculated vide RDSO Letter No. STS/E/Data loggerdtd.12.09.2011 or latest guidelines.
Supply of A -sign / AG - Sign Unit Numbers with Brackets &Fixing accessories.
Universal Hand cuff lock as per Numbers Instruction of Engineer In charge.
Supply of 5% essential spare as Lot per the OEM list of MSDAC s u p p l i e d above.( Firm shall supply minimum 1 no. of each card)
Supply of Copper tape of size Metre 25x2 mm for interconnecting earth pits to form loop earth.
Supply of earth enhancement Kg material for treatment of earth pits as per Specification No. RDSO/SPN/197 Ver 1.0 or latest.
Supply of 50 mmx 6 mm Metre galvanised steel tape for interconnecting the earth pit's earth.
Supply of MS flat plate strip( Metre specification no. 226STD or latest) of 35 mmx 6 mm thick for earth connection to signal post and location box etc. RATLAM DIVISION-S AND T/WESTERN RLY
Supply of 10 Sq mm PVC Metre insulated Single core Multi- strands copper conductor(Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Quantity wise colour to be decided by consignee.
Supply Multistrandsingle core FR PVCinsulated copper cable as perIS:694 for connecting main earth electrode to MEEB.
Supply of 32 mm ISI mark PVC Metre conduit pipe as per the instructions of engineering in- charge. Total 14387306.41 Item- 2 B3-Execution items. S No. Item No Description of Item Unit Qty Rate Amount RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Installation, Testing & Set Commissioning of Networkable Single loop addressable Fire alarm Control panel expandable upto 2 loops & interface with GSM/LTE module working as per RDSO/SPN/217/2025 ver-3.1 or latest. The control panel shall be networkable to Zonal /Divisional Headquarters preferably over TCP/lP and shall have clock synchronization facility. This schedule includes supply of TCP/IP converter/ Networking card. The control panel shall have provision of Graphical software to enable remote monitoring of entire fire detection and alarm system of a station from Head Quarters. The control panel shall be designed to work on power supply of 110V/230V AC as well as on DC battery backup of adequate capacity to work upto 24 hrs. Backup. The Power supplies like batteries and chargers shall be supplied by the contractor. The Control Panel shall have means for the user to visualize and interact with the complete Automatic Fire Detection and Alarm System layout through a user-friendly software executable on a standard Windows based Personal Computer. It shall be possible to download data and extend alarms from Control Panel through suitable ports like RS485/RS232/USB/TCP/IP into a PC/Laptop available with SSE at the installation and remote location (Divisional Control room) operating on Windows platform. The software for downloading and analysing fault data shall be provided & shall be compatible with the latest windows operating system. Detection, actuation, and control system shall have provision for automatic as well as manual operation. The GSM/LTE module for interfacing with Control panel duly providing compatible SIM with SMS facility on minimum of 5 numbers (users) and all other accessories. Spares cost are also included & to be supplied as per RDSO para no. 4.15. RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Installation ,testing and Set commissioning of single channel laser or High power LED based Aspiration detection unit ( for AC room) with area covering 5000 sq. ft. with programmable 4 stage alarm generation and with 4 addressable modules. It should have auto cleaning facility in optical chamber, electronic discrimination of particle size, ultrasonic air flow sensing auto learn feature with TCP/IP network capability, the aspiration system shall also include external power supply unit with battery backup. Approval-UL/LPCB/VDS listed and shall comply to specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15
Supply, installation testing & Numbers commissioning of Heat and smoke multi sensor with back box with integral short circuit isolator as per specification No. RDSO/SPN/217/2025 ver-3.1 or latest and required to be provided at suitable locations inside the diesel generator room, battery room, ASM room, and other S&T service rooms as directed by the Railway site Engineer. The location of fixing is to be meticulously decided so that full advantage of the system is achieved. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation and Testing, Numbers commissioning of Audio Visual alarm (Hooter and strobe) with back box controlled through addressable control model. Visual Alarms (Strobe): It shall be preferably flashing type RED/WHITE Color. Audio Alarms (Hooter): It shall be preferably with Piezoelectric type sounder. The sound level shall be preferably adjustable type up to 90dB at a distance of 1m as per specification No. RDSO/SPN/217/2025 Ver - 3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15. RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Installation and Testing, Numbers commissioning of Analogue Addressable and resettable Manual call point with back box with integral short circuit isolator, Analogue addressable protocol having status LED for alarming & standby mode, Binary coded dip switch addressing. It shall have inbuilt fault isolator or alternate arrangement which shall isolate the Manual Call Point in case of open/short circuit fault within it as per specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation, Testing and Numbers Commissioning of Analogue Addressable type Isolator modules device for isolating in case of any fault, complying to the RDSO/SPN/217/2025 ver-3.1 or latest. Inspection by Rep. of Railway Engineer. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, Testing and Numbers Commissioning of Relay module with back box and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, testing and Numbers commissioning of Monitor module with back box and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation, testing & Numbers communication of Linear Heat Sensing (LHS) Interface module with all accessories for integration with main line fire alarm control panel as per RDSO specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation Testing and Metre commissioning of Analogue type Linear Heat Sensing cable with required module to be integrated on main Fire Alarm Panel as per specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15. RATLAM DIVISION-S AND T/WESTERN RLY
Supply of Power supply System Set 24 V/2 Amp with built in Charger with battery backup as per specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation Testing and Metre commissioning of FRLS/Fire Survival Circuit Integrity Cables and power cable with all accessories for connection of Fire Alarm devices specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, Testing & Metre Commissioning of UL/LPCB/VDS listed CPVC Pipe with suitable diameter as per requirements & pipe accessories for the Aspiration detection shall comply to RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation, configuring, Numbers testing and commissioning of remote monitoring system along with software (GUI) along with license for Min. 20 addressing control panels with license as per RDSO/SPN/217/2025 Ver- 3.1 or latest. This includes necessary gateway card and network interface card for the system fully functional as desired by railways. Spares cost are also included & to be supplied as per RDSO para no. 4.15. RATLAM DIVISION-S AND T/WESTERN RLY
Installation, commissioning of MicroProcessor based Data Logger System with 512 digitalinputs and 32 analog inputs with protocol converteras per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) orlatest. It includes supply of all the items required forcomplete indoor relay room wiring from data loggerto relay rack tag blocks/relay bases,drawing/extension of power supply up to Data Logger.It includes relay room door lock checkingarrangement, commercial power supply monitoringarrangement & monitoring of DG sets, ELD, IPS,UFSBI, BI, MSDAC, interfacing with EI andinterlinking & networking of Data logger. It alsoincludes installation of MODEM and other interfacingcards, if required for networking of Data Logger.Note: Total numbers of relays and other signallingfunctions/gears required to be wired as per listcirculated vide RDSO Letter No. STS/E/Data loggerdtd.12.09.2011or latest guidelines.
Alteration in existing data Numbers logger wiring and re-validation of inputs as per site requirement. Workincludes supply of wiring material , shifting/re fixing of DATA LOGGER (if required).
Supply, Installation, Testing and Numbers Commissioning of Earth Leakage Tracking Unit (ELTU) for 12 Channel ELD.
Fixing of A-Sign/AG-Sign unit on Numbers signal post. The item includes fixing of'A' sign/ 'AG' sign unit on signal post with bracket,hood etc. Item includes supply of bracket & fixing materials etc. by the contactor. The item also includestermination of cables & wiring inside Co- On signal/'A' sign/ 'AG' sign unit as per standard practice.
Installation ferules/cable stickers as per instruction of Engineer in charge. This includes supply of cable tie( if required) and shorting of ferules as per CTR and Location details.
Suppy and installation of ELD Set for quad cable conductors, earth resistance sensing unit for 24 nos of conductors with metering facility for one conductorat a time as per instructions of engineering in-charge. RATLAM DIVISION-S AND T/WESTERN RLY
Provision of Earth connection RMT toLoaction Boxes and signals withMS Flat. A)Supply of MS flat ofsize 40X6mm at site which includes loading,unloading,transportation and fixing.
Supply of GI bolt of size M12 Set x25mm with two plan washers.
Drilling of holes in MS flat of Numbers defferent size at site.
Cutting bending, twisting MSflat duly heating at site.
painting onecoating Red oxide and two coatsof Black paint .
Drilling of Holes in Location Numbers Boxes.
Termination of cable cores on Numbers ARA terminal/fuseblocks,8 way terminals block/ Screw-less connectorsin theapparatus cases/ cable termination rack at bothends.Both ends of a cable core terminated shall becountedas one terminal. This includes all associatedworks ofpulling out the cable from underground. Theitemincludes dressing of cables, making wiring treeetc. Thework shall be done as per Location/Cableterminationplans and as per the instruction ofEngineer-in-charge.
Complete painting varnishing Per work at station.ThisIncludes IBH/LC/STN/Auto painting of signal posts section andfittings,apparatus cases, point machine, junctionboxes,signal machine, rail post etc. complete. Thisalsoincludes Varnishing, Letter writing, on terminalNos.and other details as per S.E.M part II annexureVIand instructions of Engineer at site. Itemincludespainting of distance of main cable run fromG.P oneach G.P. nearest to cable run and paintingofdistance of signal base from nearest line onthesignal base. At least two coats of paint is beappliedbesides primary coating of red oxide. Thisincludessupply of paints varnishes and all materialrequiredfor complete painting work at a station Thisincludespainting on existing functional units also asperinstruction of engineer-in- charge. RATLAM DIVISION-S AND T/WESTERN RLY
Location survey of cable route, Route Kilo Meter preparation of tentative and (RKM) final cable route plan (for OFC/Quad cable only) as per approved format in the section including supply of final route plan after the cables are laid and commissioned indicating clearly the exact position of the cable, joints and other critical items with reference to OHE mast & other fixed structures, etc. in 06 nos. hard bound copies on white bond paper of maximum A-3 size well documented and bound with plastic covers with editable soft copy in Autocad (latest version) .
Supply & fixing of GI troughing Running Metre on girder bridges for carrying cables. Fixing of GI troughing with Girder to be donewith hook/ 'J' bolts of suitablesize to held the load of thetroughing as per Drg. No.CSTE/3004 and CSTE/3006.This item also includes the filling one layer of Bitumencompound as per extantpractice. Supply and fixing of GI troughing of size 150mm x200 mm x 2000mm.
Supply & fixing of GI Channel on Numbers girder bridges forcarrying cables. Fixing of channel with Girder to be donewith hook/ 'J' bolts of suitablesize to held the load of thetroughing as per Drg. No.CSTE/3004 and CSTE/3006.This item also includes thefilling one layer of Bitumencompound as per extantpractice. Supply and fixing of GI channel of size 100mm x50mm x06mm 1.2 Mtr long.
Hiring of 1 no. Vehicles (SUV) for Month 2000 Km monthly for SnT works for execution of work for the peiod of 24 months; Outstation 24*7 for the entire section as per the instructions of engineering incharge. Technical specification 1.95
Hiring of 1 no. Vehicles (MUV) Month for 2000 Km monthly for SnT works for execution of work for the peiod of 24 months; Outstation 24*7 for the entire section as per the instructions of engineering incharge.Technical specification 1.95 RATLAM DIVISION-S AND T/WESTERN RLY
Modification/Alteration existing EI of Ujjain station (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material / connectors / fuses / communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/ LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTO CAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied.
Re-Designing/alteration of EI Station programme, testing and commissioning for phase working during patch ABS (at any station if required). The item includes redesigning of theapplication logic to suit SIP, installation, wiring testingcommissioning of the EI including FAT/SAT etc.
Excavation and Casting of Numbers foundation for main signal post as per CSTE/6294 (WR) with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost.
For Transportation,Installation & Commissioning of SMPSbased Integrated Power Supply Systemasper RDSO/SPN/165/2023 Ver. 4.0Amdt. 1 and DRG. NO. CSTE/6155/I,along with Sealed Maintenance freeVRLABattery set of 60 cells (stackable),in Combination of 55+5 cells (each cellof 2V/300 AH Capacity) fully chargedconforming to RDSO Specification No.IRS:S:93/96(A) (Amd.1) with latestamendment. RATLAM DIVISION-S AND T/WESTERN RLY
For Transportation,Installation & Commissioning of SMPSbased Integrated Power Supply Systemasper RDSO/SPN/165/2023 Ver. 4.0Amdt. 1 and DRG. NO. CSTE/6155/I,along with Sealed Maintenance freeVRLABattery set of 60 cells (stackable),in Combination of 55+5 cells (each cellof 2V/300 AH Capacity) fully chargedconforming to RDSO Specification No.IRS:S:93/96(A) (Amd.1) with latest amendment.
Supply, Fabrication & fixing of Sqm hylam sheet of size12 mm thick (other dimension i.e. length andbreadthwill bedecided by Engg-in-charge) forA/case NE typebyproviding all fixtures includingfixing of PVCcoatedString Rods at the back side forcable supportwithcontractor own materials. Theitem includes fixingof M6terminals or screw less/fuse blocks /HRC fusesND typeon each strip. Twoextra holes on both sidesof M6terminals or screwless/ fuse blocks /HRC fuseand twoextra holes forfixing the sheet. Note: (i) Thecompletehylam sheetto be covered with either M6terminals orscrew less/fuse blocks /ND type HRCfuses as perinstructionsof engineer at site. (ii) Hylamsheet to be ofgradeP2. (iii) M6 terminals or screwless, HRC fuses willbesupplied by Railway. Theabove item alsoincludesfixing of Q series (GPR) relays.
Laying of polylefin cable duct Numbers /RCC duct half round after laying of cable in the trenches before backfilling of soil as per the instrcutions of engineering in- charge. RATLAM DIVISION-S AND T/WESTERN RLY
Digging a trench to a minimum Metre depth of0.5 meter and laying 50x6 mm bareGalvanized steel tape (Interconnectingtape) connecting all the earth pits.Routing and laying 50x6 mmGalvanized steel tape connecting all theearth pits. Carrying out exothermic weldconnections on all the earth electrodesto Galvanized steel tape of size 50x6mm for interconnecting the earth pits. Itshall be ensured that the distancebetween any two earth electrodes shallbe minimum 3 meter (length of theearth electrode) and max up to 6 meter(twice the length of the earth electrode)to avoid mutual resistance effects. Thisinterconnecting tape shall also becovered with approximately 30 Kg ofearth enhancing compound for each 3meters length. Earth enhancementcompound 10Kg along each meter alsoto be spreaded along the Galvanizedsteel tape.
Digging a trench to a depth of at Metre least0.5 meter and run the two 35 sq. mmearth conductor (procured againstsupply item) from Earth pit to MEEB.Routing and exothermic termination oftwo 35 sq. mm earth conductors intrench from earth pit to 300 x 25 x6mm MEEB, which is to be fixed insidethe equipment room with two 60 mm insulation studs.
Shifting of existing cables from Numbers old location boxes / relay room to new location boxes / new cable termination racks, terminating the conductors in serial order, bunching neatly for matching the circuits with new cables as per cable plan.
Connecting main earth pit to Job MEEB and the MEEB to SEEBs/SPDs and interconnecting earth pits as per site requirement ans instructions of engineering in-charge.
Digital mapping using drone / Set LiDAR survey for RFID planning (1 Set set = 4 Stations)
Supply Installation & Commissioning of station TCAS RIU (Remote I/F unit) with atleast 32 Field I/P's as per RDSO spec. The RIU should have provision of OFC OR Quad I/F and should be connected to central TCAS in a Ring network. This includes modems, I/F, Earthig, Wiring & Signal functions etc. (=NO of OSL LC+IBS) RATLAM DIVISION-S AND T/WESTERN RLY
Alteration in stationary Kavach Set including upgradation / updation of Kavach hardware, accessories, software, electronics, RFID tags etc., installation, testing and commissioning.
Supply and programming of Set RFID tags, border tags etc. (1 Set = Main and Duplicate Tags)
Shifting, reprogramming and Set testing of RFID tags as per Version 4.0.
Supply installation testing and Numbers commissioning of Earth Leakage Detector as per RDSO/SPN/256/2002 or latest with latest amendments. The basic detector unit shall comprise of 8 channels, for use on signaling circuits of 110V AC/DC and/or 60V/24V/12V DC as ordered by purchaser. If the detector is required for less number of channels, dummy plates shall be provided. For additional requirement add on /expendable cabinet may be used. The voltage specified shall be provided with + 25% and - 10% tolerance. Total 80498292.78 Item- 3 A4 Supply Items for LC gate interlocking. S No. Item No Description of Item Unit Qty Rate Amount
Electric RotaryType as per spec No.IRS : S-21/01 & Drg No. SA-22601 (ALT4)
Fail DelayDevice 24V DC, 30 / 60 / 120Sec for Railway Signallingconforming to IRS:S- 61/2000with Amdt. No. 2
Supply of Master telephonewith Numbers voice recording facility ofElectronic LC gate telephonesystems with voice recorder asper RDSOSPEC.NO.RDSO/SPN/TC/51- 2021 REV 1.0 or latest. Materialto be supplied from RDSO'sapproved source only with03(three) years full warranty.Note: - 1) the date ofmanufacture of the item shouldbe of current year at the timeof supply to railway stores.
Supply of Gate (slave)telephone Numbers as per RDSOSPEC.NO.RDSO/SPN/TC/51- 2021 REV 1.0 or latest Materialto be supplied from RDSO'sapproved source only with03(three) years full warranty.Note: - 1) the date ofmanufacture of the item shouldbe of current year at the timeof supply to railway stores. RATLAM DIVISION-S AND T/WESTERN RLY
Supply of 24V Power supplyunit Set with MF Battery andCharger for Master Telephoneas per RDSOSPEC.NO.RDSO/SPN/TC/51- 2021 REV 1.0 or latest. Materialto be supplied from RDSO'sapproved source only with03(three) years full warranty.Note: - 1) the date ofmanufacture of the item shouldbe of current year at the timeof supply to railway stores. Note: PSUshould have another output of12 V + 0.5 V, with currentcapacity of minimum 500 mAfor local use of StationTelephone Unit.
PVC insulated Railway Signaling Kilometre Indoor Single corewire conforming to IRS 76/89 (Amd3) or latest. Note:- Wire Colours shall be decided by engineer - in -Charge." (i)1 x 0.6 mm
PVC insulated Railway Signaling Kilometre Indoor Single corewire conforming to IRS 76/89 (Amd3) or latest. Note:- Wire Colours shall be decided by engineer - in -Charge (ii)1 x 1 mm
Supply,Transportation Commissioning of SMPS based Mini Integrated Power Supply System as per RDSO/SPN/165/2023 Ver. 4.0 Amdt. 1and DRG. NO. CSTE/6155/I,along with Sealed 110 volt 200AH LMLA Battery set. Total 2044986.00 Item- 4 B 4 Execution Items for LC gate interlocking. S No. Item No Description of Item Unit Qty Rate Amount
Execution telephonewith voice recording facility.This Includes testing andcommissioning, all installationrelated material to be suppliedby the contractor as per siterequirement.
Execution (slave)telephone. This Includes testingand commissioning, allinstallation related material tobe supplied by the contractoras per site requirement. RATLAM DIVISION-S AND T/WESTERN RLY
Supply and Installation of RO Set membrane based Deioniser plantto produce Battery water of TDS less than5 ppm irrespectivewaterof the quality of raw water, pH Value:- 6.5 to 7.2,specificwaterelectric conductivity :- 0 to 5micro mhos/cm at 25 DegreeCelsius,output capacity should be 12-15 Ltr purifiedwater/Hour. Plant should have suitable fixture/wall mountingwaterarrangement with external PVC storage tank of capacity 200Ltr, Plant should have on board TDS meter, Indication ofOn/Off, Solenoid/Flow switch fitted to avoid dry run of themachine, Weight sensor/Float switch installed on storage tankto avoid over flowing of the tank. The item includes supply ofone set of the spare\ filters/membranes in addition to thefitted filters membrane with the machine (spare should be ofsimilar spec/type as used in the machine). Plant should work on 230V AC input (Internally works on 24V DC) and should notrequire any type of chemical re- charging except filters andmembranes. The life of filter/membrane should not last beforeproduction of minimum 12000 Ltr of battery water. Itemwaterincludes supply of all the accessories required for installationof the plant like fasteners, connecting pipes (of length up to 2Mtr), cable from wall socket to the machine (of length up to 2Mtr),couplers/tap required to connect it from water tap/outlet,waterPVC pipe up to storage tank (of length up to 2 Mtr).The qualitytest certificate of produced water must be submitted by thewatersupplier from any repudiated test laboratory. The OEM shouldgive on-site warranty of one year. RATLAM DIVISION-S AND T/WESTERN RLY
Maintenence of Track Mounted Numbers Equipments like S&T fittingon turnouts including different activities duringBCM/TTM/UNIMATE machine works as well as otherongoing engineering work and S&T maintenance work asfollows: Specially opening and refixing of DCTrack circuitjumpers/ Axle Counter transducers during differentEngineering Works. Opening of DCTrack circuit / AxleCounter transducers digging work from rail to TLJB / TMU/Location is required to be done as per site requirement alsoafter refixing of DCTrack circuit / Axle Counter transducersneeds to be buried in proper depth. It includes drilling hole inrail as per site requirement. The team to be provided for thiswork should comprise of: Fitter - 1 Nos., Blacksmith - 1 Nos.,Mason / Carpenter - 1 Nos. and Helpers - 5 Nos. also itincludes any work of Electrical operated lifting barriers(EOLB) or sliding boom and earthing arrangement ofSignalling gears. Any other work as per instruction ofRailway Engineer. All T&P & jigs required to execute thework will be supplied by the contractor. (NOTE: THE UNITFOR THIS ITEM SHALL BE READ AS "PER DAY PER TEAM")
Arranging/providing of labours Man-Days for various safety related works such as protection of track etc. with contractors T&P, equipment etc. as and when required by the Engineer in charge. Scope of work as furnished in the tender technical specification 1.94 and directed by the Engineer in charge. Total 783835.00
Item Breakup - XS2-NS Schedule
Design, manufacture and supply Per Functional of Hot Standby Distributed Vital Bit Architecture (Central plus two OC) Electronic Interlocking (EI) system for 6 nos. of Auto Hut as per RDSO specification no. RDSO/SPN/192/2019 Ver.2.0 with latest amendment and as per technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment ,object controller, Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements, Industrial grade maintenance Terminals (32'' LED or higher size with UPS minimum 1 hr back up with Printer) and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. For positive variation card wise/Modules etc. breakup should furnish by tenderer.Technical Requirement:1. No of Bits Each station.2. Architecture-Minimum 2 out of 23. Non vital I/O- can be used only for accessories where SIL-4 condition required.4. Station less than 200 routes- RDSO/SPN/192/2019 Ver.2.0 with latest amendment.5.Station greater than 200 routes - RDSO/SPN/203/2011 Ver1 or latest.Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC-DC Convertors, Moxa switch, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare).Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately.Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. Total 115779027.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .