SUPERINTENDING ENGINEER
132 KV LALKUAN S/S CAMPUS GHAZIABAD
works at substations
2025_UPTCL_1049893_1
T-06/ETC/GZB/2025-26
Open Tender
Electrical Works
Fixed-rate
30 days
22KV SUBSTATION SAHIBABD
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AS PER NIT
₹2,500
15 Jul 2025
18 Jun 2025
4 Jul 2025
18 Jun 2025
4 Jul 2025
18 Jun 2025
Amount
Erection of Auxiliary structure i.e ALP & ABL. The work consists of shifting of all material from store to site of erection as per drawing & technical specification.
Erection of following equipments as per technical specification including removing of packing and shifting to working site.
33 KV CT Ratio (400-200/1-1)
33 KV Bus Isolator
33 KV CB & its associated structure
33 KV CT Junction Box and along with necessary fixtures/clamps
33 KV PT Junction Box and along with necessary fixtures/clamps
33 KV Line Isolator
Complete interconnection of 33 KV equipment using ACSR Panther conductor and suitable Terminal connector from 33 KV main Bus bar to Bus Isolator, Bus isolator to CB ,CB to CT & Ct to Line Isolator , Line isolator to PT & PT to LA including cutting, bending of conductor and jumpering, clamping along with all associated work as per technical specification & site requirement. Above all interconnections are for twin panther conductor.
Laying and termination of control cable of following size from control room to 33 KV CB, CT, PT including removing and resetting of trench covers.
PVC control Cable 2x2.5 mm2
PVC control Cable 4x2.5 mm2
PVC control Cable 6x2.5 mm2
Termination of above sizes of control cable as laid above as per cable schedule and all other associated work to complete the job satisfactorily as per technical specification.
Earthing of equipments by cutting straitening, bending, laying of following size M.S. flat for earthing of Auxiliary structure , equipments structure, including excavation , back filling of earth & painting of earthing strip.
MS flat of size 50x6 mm
Description of Pilfer Proof Metering for 33 KV M/S NORMA INDIA PVT LTD BAY . Work include Removal of trench covers from trenches for laying of 1 inch dia & 2 inch dia G.I. pipe from 33 KV NORMA INDIA PVT LTD BAY Feeder bay CT & 33 kv bus PT in switchyard to energy meter in control room & placement of trench cover after completing the work.
Supply of 1inch dia & 2 inch dia G.I. Pipe with its required accessories elbow,sockets etc. & laying/inserting required size cable through 1 inch dia G.I. pipes on cable racks along the wall of cable trenches with the help of hook,clamp etc. from 33 KV NORMA INDIA PVT LTD BAY Feeder bay CT & PT in switchyard to energy meter in control room and other associated works such as cutting, bending & fixing of pipe with the help of elbow,sockets,alongwith making threads and other required material etc.
G.I. Pipe of 1 inch dia for 33KV Feeder bay CT
G.I. Pipe of 1inch dia for 33KV bus PT
G.I. Pipe of 2 inch dia for 33KV bus PT & 33KV Feeder bay CT
Shifting & erection of 33 KV Triple feeder Contol and relay panel as per technical specification of 33 KV feeders in control room from store & set properly on said place on trenches .
Description of Supply
PG CLAMP ZEBRA/PANTHER
PG CLAMP PANTHER/PANTHER
33 KV ISOLATOR L CLAMP
BUS POST CLAMP FOR PANTHER
Technocrat Electrical (BID ID -5289178)
TIRUPATI ELECTRICALS (BID ID -5281055)
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .