Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.1 L+₹27,150 (5.57%)Rejected-Finance 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹5.2 L+₹32,600 (6.69%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹5.3 L+₹40,350 (8.28%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹5.8 L+₹89,775 (18.4%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹22,320
Closing Date
18 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
OUTSOURCING OF 11 KV MAIN RECEIVING STATION OF RV COLONY, UNDER GE (I) R and D KANPUR.
2020_MES_405402_1
8223/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
GE I R and D Kanpur
As Per NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹22,320
Yes
15 Apr 2021
21 Dec 2020
20 Jan 2021
22 Dec 2020
18 Jan 2021
4 Jan 2021
60 days
Amount
Manning, operation and comprehensive maintenance of 11KV indoor substation including allied items comprising of main equipment installed as given below 1.01 to 1.08 at 11KV MES Take Over Point of residential colony of Raksha Vihar with one electrician (skilled) three shifts i.e. 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs, each shift of 08 hours of duration for 24 hours including Sundays and holidays for operation of 11KV substation with electrical equipments :-
VCB in door type 11 KV 400 Amp, Make - ITL & ISL - 03 No.
PT 11 KV/110 Volt - 01 Nos.
LT Panel with 1000 Amps ACB with allied accessories -03 Nos.
11KV GOD with DO fuse set 11 KV - 03 Nos.
Transformer in door type 11/ 0.433KV cap - 400 KVA , Make - GEC - 02 Nos.
Transformer in door type 11/ 0.433KV cap - 300 KVA , Make - ITL - 01 No.
Transformer out door type 11/ 0.433KV cap - 160 KVA , Make Kirloskar - 01 No.
HT & LT Over head line and UG cable feeding from Sub Station no.1 & 2
(i) One qualified Skilled Electrician having ITI certificate or minimum 5 Years experience in the trade in three shift only to be deployed. The staff shall not be permitted to be deployed in double shift ( No trademen/helper shall work more than 8.0 Hours in a Day ) by contractor/firm.
(ii) The overall responsibility of maintenance of power supply system /substation shall be taken care by shift persons in their respective shifts, Consumable materials like cotton cloth, cotton waste and required T&P such as megger, crimping tool, gloves, insulated cutting plier, insulated screw drivers, adjustable spanner set, screw wrench etc off sizes, lineman safety belt etc for maintenance work are to be provided by the contractor at his own cost.
(iii) Maintenance Schedule of Electric Equipment shall be strictly carried out/followed in phase manner Daily,Weekly, Monthly, Quarterly, Half Yearly as specified in particular specifications.
(iv) One MOBILE PHONE for the manning staff, centrally kept at the electric supply installation will be provided by the contractor with incoming / out going facilities during the entire period covered under the contract to keep liaison / communication with JE E/M/ Engineer-in-Charge in case of electric break down/emergency .
(v) If any breakdown HT/LT occures in RV colony complex will be attend within 2 hours and rectified by the contractor.
(vi) In event of any emergency, the contractor shall take necessary action for rectification of fault & necessary detail entries are to be entered in the log book/sheet.
M & L for ACSR conductor at errected LT/HT pole for three phase distribution and sretching/stringing with due care after taking proper shut down from concern MES competent staff complete in all respect and as directed.
Routine and periodical work required for trimmimng/cutting of tree branches of any gruth,touching/obstructing the overhead lines of HT/LT Pole of three phase distribution system at palces not more than 40 meter span distance so as to keep minium 2.0 m clearence all arround the lines and poles with due care after taking proper electric shut down from concern JE E/M including disposal thereoff (trimmed btanches) to a distance not exceeding 500m complete all as specified and directed.
Labour work required for restretching/restringingof existing loos/sagged ACSR/GI Conductor of HT/LT OH lines of three phase distribution system by opening binding wire from insulator as fixed on pole and restring OH Line with proper binding with insulator by using additional binding wire/conductor not less than 2.0 mm dia with due care using safety belt etc after after taking proper electric shut downfrom concern JE E/M complete all as directed by Engr-in-charge.
M & L for GI Conductor/wire 4.00 mm dia 8.00 swg beside to neutral conductor at errected LT/HT pole for three phase distribution and sretchinf stringing with due care after taking proper shut down from concern MES competent staff complete in all respect and as directed.
S&F Pin type, pocelain, vitreous, white brow or green insulator including one galvanised mild steel spindle, two galvaanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade. Make :Jaipuria Brothers/ Modern Insulators/ Jayshree Insulators as approved by GE(I).
All same as per item No 6.00 abovebut disc insulator 145mm X 255mm dia ball and socket type. Make :Jaipuria Brothers/ Modern Insulators/ Jayshree Insulators as approved by GE(I).
S & F PVC overhead line spiral spacer Single phase 2 wire complete all as specified and directed by GE (I).
S & F PVC overhead line spiral spacer Single phase 3 wire complete all as specified and directed by GE (I).
S & F PVC overhead line spiral spacer three phase 5 wire complete all as specified and directed by GE (I).
Routine/periodical cleaning the inside area of pump areaincluding cutting/removal of uprouting of unwanted grass,bushes and small trees near all around sub station and pump house complex complete including surface dressing and levelling by surfave excavation complete all as directed.
Supply and fixing in replacement of unserviceable Aluminium crimping Terminals (lugs) long barrel type, thimble type complete all as directed for the following sizes :- Make : Dowells/Comets/ Jainson as approvedby GE (I).
(a) 16 sqmm
(b) 25 sqmm
(c) 35 sqmm
(d) 50 sqmm
(e) 70 sqmm
(f) 95 sqmm
(g) 120 sqmm
(g) 240 sqmm
M&L for cold shrinkable type cable end joint indoor type suitable for XLPE 95 Sqmm 3 core cable 11 KV and testing all as specified and directed with terminate joint and jointing material all as specified and directed. Make : Denson/ Raychem/ M - seal as approved by GE (I).
M&L for cold shrinkable type cable end joint outdoor type suitable for XLPE 95 Sqmm 3 core cable 11 KV and testing all as specified and directed with terminate joint and jointing material all as specified and directed. Make : Denson/ Raychem/ M - seal as approved by GE (I).
DEO Traders
Kumar Electricals
G S SANDHU & CO.
DUBEY TRADERS AND ENGINEERS
Bharat Sales Corporation
Skyline Encon
Himanshu Construction and Suppliers
Gupta Constructions
YS CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .