Loading…
Loading…
Tender Value
₹27.3 L
EMD Value
₹54,600
Closing Date
27 Oct 2026, 6:00 pm
Garrison Engineer
Garrison Engineer AF Bhisiana Bathinda Punjab PIN 151201
REPAIR AND MAINTENANCE OF INTERNAL/EXTERNAL ELECTRIFICATION, SUMMER APPLIANCES, DG SETS AND CONNECTED WORK AT ABOHAR UNDER GE (AF) BHISIANA
2026_MES_792520_1
GE/BHI/TOKEN-71/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
304 days
ABOHAR
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Bhisiana
₹54,600
Yes
GE AF Bhisiana
6 Oct 2026
6 Oct 2026
29 Oct 2026
6 Oct 2026
27 Oct 2026
20 Oct 2026
6 Oct 2026 - 16 Oct 2026
13 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully existing point wiring (light/fan/sockets/bell/power point) any type complete with all accessories such as switch socket with sheet, ceiling rose, lamp holder including rusted/broken concealed conduit, junction and sunken terminal boxes etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed. | 202 | Per Point | - | - |
| 2 | Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 V grade, conforming to IS 694:2010, for main point wiring and for continues as earth wire connected to earth dolly etc. drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 20 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and made from 1.6-1.63mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket / regulator etc, complete in all respects as specified and directed by the Engineer-in-Charge.
Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ.
(ii) The quoted rate shall be deemed to include making the existing chases, formed after removal of the old conduit under the respective BOQ item, suitable for fixing the new conduit and, wherever required due to change in conduit size, alignment or routing, cutting additional/new chases in walls, ceilings or floors, and making good all disturbed surfaces with cement mortar (1:3) to match the existing finish. No extra payment shall be admissible on this account. (iii) Where ever it is not feasible to cable drawn through existing PVC conduit in roof slab (for ceiling fan point only) due to blocked, casing capping or pipe shall be provided on surface of RCC including fixing arrangement without any extra cost, cost for the same shall deemed to be included in the quoted unit rate. | 105 | Each Point | - | - |
| 3 | All as per above point wiring item but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ). | 20 | Each Point | - | - |
| 4 | Material and labour for concealed Point wiring for one socket out let 5/6 Amps point controlled by one switch on independent board (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 V grade, conforming to IS 694:2010, for main point wiring and for continues as earth wire connected to earth dolly etc. drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 20 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and made from 1.6-1.63mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket / regulator etc, complete in all respects as specified and directed by the Engineer-in-Charge.
Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ.
(ii) The quoted rate shall be deemed to include making the existing chases, formed after removal of the old conduit under the respective BOQ item, suitable for fixing the new conduit and, wherever required due to change in conduit size, alignment or routing, cutting additional/new chases in walls, ceilings or floors, and making good all disturbed surfaces with cement mortar (1:3) to match the existing finish. No extra payment shall be admissible on this account. | 40 | Each Point | - | - |
| 5 | Material and labour for concealed Point wiring for one bell /buzzer point controlled by one switch (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 V grade, conforming to IS 694:2010, for main point wiring and for continues as earth wire connected to bell earth dolly etc. drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 20 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular bell switch (min 60mm deep, suitable length and made from 1.6-1.63mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular bell switch etc, complete in all respects as specified and directed by the Engineer-in-Charge.
Note : (i) Modular bell switch shall be measured and paid separately under appropriate item of BOQ.
(ii) The quoted rate shall be deemed to include making the existing chases, formed after removal of the old conduit under the respective BOQ item, suitable for fixing the new conduit and, wherever required due to change in conduit size, alignment or routing, cutting additional/new chases in walls, ceilings or floors, and making good all disturbed surfaces with cement mortar (1:3) to match the existing finish. No extra payment shall be admissible on this account. | 5 | Each Point | - | - |
| 6 | Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch on independent board (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 V grade, conforming to IS 694:2010, for main point wiring and for continues as earth wire connected to earth dolly etc. drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 25 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and made from 1.6-1.63mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket etc , complete in all respects as specified and directed by the Engineer-in-Charge.
Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ.
(ii) The quoted rate shall be deemed to include making the existing chases, formed after removal of the old conduit under the respective BOQ item, suitable for fixing the new conduit and, wherever required due to change in conduit size, alignment or routing, cutting additional/new chases in walls, ceilings or floors, and making good all disturbed surfaces with cement mortar (1:3) to match the existing finish. No extra payment shall be admissible on this account. | 32 | Each Point | - | - |
| 7 | Supply and fixing modular switch 6Amps, one way, 1 module complete all as specified and as directed. | 165 | Each | - | - |
| 8 | Supply and fixing modular switch 16Amps, one way, 1 module with indicator complete all as specified and as directed. | 32 | Each | - | - |
| 9 | Supply and fixing bell push modular switch 6Amps, one way, 1 module complete all as specified and as directed. | 5 | Each | - | - |
| 10 | Supply and fixing modular Socket outlet multipurpose type 6 Amp, 2 module complete all as specified and as directed. | 60 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
TenderDocToken71.pdf
Tender Documents • 1.16 MB
BOQ_888658.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .