Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 153 PKT 21 SECTOR 24 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 2 MORE SARAI CH CHOWK DELHI CENTRAL DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
4 Oct 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE SDW V
Ring Road Andrews Ganj New Delhi 110049
Installation of Sewage Electric Trolley pumps at outfall point of Batla House (Interceptor sewer)
2024_DJB_262938_1
Short Press N.I.T. No. 06 2024 25
Open Tender
Miscellaneous Works
Works
91 days
Ring Road Andrews Ganj New Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Indian Bank
₹90,000
10 Oct 2024
28 Sept 2024
4 Oct 2024
28 Sept 2024
4 Oct 2024
28 Sept 2024
Location Name “A” marked at outfall connection No.12(Dhobi Ghat) Installation of sewage electric trolley pump at outfall point of Batla House (Interceptor sewer) of capacity 15 HP – 1 no., Head at least 12.5 m on the sewage system with the delivery line, flanged pipe of all the pumps up to the length of 15 mtr, suction pipe with NRV, clamp, flange etc & fabrication of suitable size tin shade of panel board, night shelter for staff and providing the space for fixing the BSES electric meter i/c cabling from BSES meter to 3 ph cut out board etc by the deployment of 1 no. semi-skilled for the operation of pump sets and 1 no. of un-skilled for cleaning the kachra, silt & time to time charging of pump etc. The work includes pump sets along with all their accessories. Installation of pumps and their accessories such as barricading with all the safety provisions and providing/fixing of starters, switches etc, and other miscellaneous accessories as per site requirement. Without DG set
Location Name “B” marked at outfall connection No.07(Shah Masjid) Installation of sewage electric trolley pump at outfall points of Batla House (Interceptor sewer) of capacity 25 HP – 1 no., Head at least 12.5 m on the sewage system with the delivery line, flanged pipe of all the pumps up to the length of 15 mtr, suction pipe with NRV, clamp, flange etc & fabrication of suitable size tin shade of panel board, a night shelter for staff and providing the space for fixing the BSES electric meter i/c cabling from BSES meter to 3 Ph cut out board etc by the deployment of 1 no. semi-skilled for the operation of pump sets and 1 no. of un-skilled for cleaning the kachra, silt & time to time charging of pump etc. The work includes pump sets along with all their accessories. Installation of pumps and their accessories such as barricading with all the safety provisions and providing/fixing of starters, switches etc, and other miscellaneous accessories as per site requirement. Without DG set
Location Name “C” marked at outfall connection No.06 (Mumtaz Masjid) Installation of sewage electric trolley pump at outfall points of Batla House (Interceptor sewer) of capacity 15 HP – 1 no., Head at least 12.5 m on the sewage system with the delivery line, flanged pipe of all the pumps up to the length of 15 mtr, suction pipe with NRV, clamp, flange etc & fabrication of suitable size tin shade of panel board, a night shelter for staff and providing the space for fixing the BSES electric meter i/c cabling from BSES meter to 3 Ph cut out board etc by the deployment of 1 no. semi-skilled for the operation of pump sets and 1 no. of un-skilled for cleaning the kachra, silt & time to time charging of pump etc. The work includes pump sets along with all their accessories. Installation of pumps and their accessories such as barricading with all the safety provisions and providing/fixing of starters, switches etc, and other miscellaneous accessories as per site requirement. Without DG set
Location Name “D” marked marked at outfall connection No.05 (Lal school) Installation of sewage electric trolley pump at outfall points of Batla House (Interceptor sewer) of capacity 25 HP – 1 no., Head at least 12.5 m on the sewage system with the delivery line, flanged pipe of all the pumps up to the length of 15 mtr, suction pipe with NRV, clamp, flange etc & fabrication of suitable size tin shade of panel board, a night shelter for staff and providing the space for fixing the BSES electric meter i/c cabling from BSES meter to 3 Ph cut out board etc by the deployment of 1 no. semi-skilled for the operation of pump sets and 1 no. of un-skilled for cleaning the kachra, silt & time to time charging of pump etc. The work includes pump sets along with all their accessories. Installation of pumps and their accessories such as barricading with all the safety provisions and providing/fixing of starters, switches etc, and other miscellaneous accessories as per site requirement. Without DG set
Location Name “E” marked at outfall connection No.04 (18 Number Gali) Installation of sewage electric trolley pump at outfall points of Batla House (Interceptor sewer) of capacity 20 HP – 1 no., Head at least 12.5 m on the sewage system with the delivery line, flanged pipe of all the pumps up to the length of 15 mtr, suction pipe with NRV, clamp, flange etc & fabrication of suitable size tin shade of panel board, a night shelter for staff and providing the space for fixing the BSES electric meter i/c cabling from BSES meter to 3 Ph cut out board etc by the deployment of 1 no. semi-skilled for the operation of pump sets and 1 no. of un-skilled for cleaning the kachra, silt & time to time charging of pump etc. The work includes pump sets along with all their accessories. Installation of pumps and their accessories such as barricading with all the safety provisions and providing/fixing of starters, switches etc and other miscellaneous accessories as per site requirement. Without DG set
Location Name “F” marked at outfall connection No.03 (Moti Masjid) Installation of sewage electric trolley pump at outfall points of Batla House (Interceptor sewer) of capacity 10 HP – 1 no., Head at least 12.5 m on the sewage system with the delivery line, flanged pipe of all the pumps up to the length of 15 mtr, suction pipe with NRV, clamp, flange etc & fabrication of suitable size tin shade of panel board, a night shelter for staff and providing the space for fixing the BSES electric meter i/c cabling from BSES meter to 3 Ph cut out board etc by the deployment of 1 no. semi-skilled for the operation of pump sets and 1 no. of un-skilled for cleaning the kachra, silt & time to time charging of pump etc. The work includes pump sets along with all their accessories. Installation of pumps and their accessories such as barricading with all the safety provisions and providing/fixing of starters, switches etc, and other miscellaneous accessories as per site requirement. Without DG set
M G Traders and Engineers (BID ID -1533719)
CHANDERA BUILDERS (BID ID -1533703)
SONI SALES and SERVICE (BID ID -1533153)
Goodwill Enterprises (BID ID -1533656)
HYDROCON ENGINEERS (BID ID -1533059)
Gupta Brothers (BID ID -1533585)
B.S.Enterprises (BID ID -1533816)
ARIHANT ENGINEERS AND TRADERS (BID ID -1533720)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .