Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC 3B CHANDRALOK APARTMENT 3RD FLOOR KUTCHERY ROAD RANCHI JHARKHAND PIN 834001 | RANCHI | JHARKHAND | 834001 | ₹25.4 L | L1 | Accepted-AOC Lowest bidder. |
| 2 | L2₹26.2 L+₹84,735.50 (3.34%)Rejected-Finance 27 2ND FLOOR CITY CENTRE CLUB ROAD RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | ₹26.2 L+₹84,735.50 (3.34%) | L2 | Rejected-Finance Other than lowest bidder. |
| Sl No | Description | Qty | Unit | Bihar traders L2 | ASSOCIATED BUILDCON LLP L1 |
|---|---|---|---|---|---|
| 1.00 | Dismatling and taking down old unserviceable LT feeder pillar and Supply, installation, testing and commissioning of LT Feeder pillar not lss than 0.500x0.600x0.50m, outdoor type factory made (CPRI approved) with canopy, double door, front & back both side oenable type fixed with hinges and locking arrangement with Aldrop latches, fabricated of CRCA sheet, inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer 3.15 mm thick, gasket, rubberised gasket, supported on 50x50x6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 300 Amps rated capacity mounted on porecelain insulators totally enclosed chamber for protection 3 Phase 415 volt with suitable capacity aluminium bus bar/PVC copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & washers wih danger notice plate. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate complete all as specified and directed. | 2 | Each Job | 50,000 ₹1,00,000 | 48,800 ₹97,600 Lowest |
| 2.00 | Servicing to LT Feeder pillar boxes comprising MCCBs/change over switches metering eqpt etc. as incomming/outgoing controls including cleaning, greasing the hinges, locking arrangement, checking the seviceability of individual items, identification of the defective parts replacing the wornout fastners, insulators, rubber door beadings, gakets etc all as directed Note:- (1) Unserviceable parts replaced if any shall be measured & paid seperately under respective items. | 10 | Each | 1,900 ₹19,000 | 1,880 ₹18,800 Lowest |
| 3.00 | Removing the existing hinges by cutting and supply and fixing of new hinges all as per existing size | 8 | Each | 450 ₹3,600 | 440 ₹3,520 Lowest |
| 4.00 | Painting of LT feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc complete all as specified and directed. | 8 | Each Job | 2,500 ₹20,000 | 2,480 ₹19,840 Lowest |
| 5.00 | Rewiring the LT feeder piller by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc,after taking out the old unserviceable wiring all as directed. | 8 | Each Job | 2,000 ₹16,000 | 1,980 ₹15,840 Lowest |
| 6.00 | Material and labour for replacement of LED type indicator lamp (RYB) (Set of three) complete all as specified. | 4 | Each | 500 ₹2,000 | 480 ₹1,920 Lowest |
| 7.00 | Suupply and Fixing in replacement of Digital Amp Meter 0-250 Amp with including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. | 5 | Each | 2,000 ₹10,000 Lowest | 2,200 ₹11,000 |
| 8.00 | Suupply and Fixing in replacement of Digital Volt Meter 0-500 V including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. | 4 | Each | 2,500 ₹10,000 | 2,400 ₹9,600 Lowest |
| 9.00 | Supply and fix Indoor resin cast ring type low tension current transformer 50/5A to 75/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992 | 4 | Each | 1,200 ₹4,800 Lowest | 1,250 ₹5,000 |
| 10.00 | Supply and fix Indoor resin cast ring type low tension current transformer 100/5A to 300/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992 | 4 | Each | 1,100 ₹4,400 Lowest | 1,250 ₹5,000 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
11 Aug 2026, 6:00 pmClosed
Shri Manjul Kumar Tripathi, GE
Garrison Engineer Ranchi Military engineer Services 7th club road Ranchi
REPAIR OF DAMAGED FLOOR TILES KOTA STONE BROKEN ROOF SHEET JOINERIES CUP BOARDS PAINTING OF EXTERNAL SURFACES IN VARIOUS LOC AT BURKI ND TPT LINES ND REPLCMENT OF FEDER PILAR BOXS AT NMKUM ND KHJATOLI ND REPAIR OF DAMAGED PT WIRING SWITCH SOCKET ETC
2026_MES_777365_1
8200/1724/E8
Open Tender
Civil Works
Item Rate
180 days
GE Ranchi
Class D and Cat a (i) , b (i)
7 documents required · 7 mandatory
₹500
GE Ranchi
₹54,000
Yes
21 Sept 2026
9 Jul 2026
18 Aug 2026
9 Jul 2026
11 Aug 2026
23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismatling and taking down old unserviceable LT feeder pillar and Supply, installation, testing and commissioning of LT Feeder pillar not lss than 0.500x0.600x0.50m, outdoor type factory made (CPRI approved) with canopy, double door, front & back both side oenable type fixed with hinges and locking arrangement with Aldrop latches, fabricated of CRCA sheet, inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer 3.15 mm thick, gasket, rubberised gasket, supported on 50x50x6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 300 Amps rated capacity mounted on porecelain insulators totally enclosed chamber for protection 3 Phase 415 volt with suitable capacity aluminium bus bar/PVC copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & washers wih danger notice plate. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate complete all as specified and directed. | 2 | Each Job | - | - |
| 2 | Servicing to LT Feeder pillar boxes comprising MCCBs/change over switches metering eqpt etc. as incomming/outgoing controls including cleaning, greasing the hinges, locking arrangement, checking the seviceability of individual items, identification of the defective parts replacing the wornout fastners, insulators, rubber door beadings, gakets etc all as directed Note:- (1) Unserviceable parts replaced if any shall be measured & paid seperately under respective items. | 10 | Each | - | - |
| 3 | Removing the existing hinges by cutting and supply and fixing of new hinges all as per existing size | 8 | Each | - | - |
| 4 | Painting of LT feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc complete all as specified and directed. | 8 | Each Job | - | - |
| 5 | Rewiring the LT feeder piller by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc,after taking out the old unserviceable wiring all as directed. | 8 | Each Job | - | - |
| 6 | Material and labour for replacement of LED type indicator lamp (RYB) (Set of three) complete all as specified. | 4 | Each | - | - |
| 7 | Suupply and Fixing in replacement of Digital Amp Meter 0-250 Amp with including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. | 5 | Each | - | - |
| 8 | Suupply and Fixing in replacement of Digital Volt Meter 0-500 V including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. | 4 | Each | - | - |
| 9 | Supply and fix Indoor resin cast ring type low tension current transformer 50/5A to 75/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992 | 4 | Each | - | - |
| 10 | Supply and fix Indoor resin cast ring type low tension current transformer 100/5A to 300/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992 | 4 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Tender1724.pdf
Tender Documents • 0.60 MB
BOQ_870611.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .