Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹71.5 LAccepted-AOC H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | 1 | Accepted-AOC L1 | |
| 2 | 2₹80.3 L+₹8.1 L (11.2%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 2 | Rejected-Finance L2 | |
| 3 | 3₹1.0 Cr+₹31.7 L (43.9%)Rejected-Finance 702 MODEL TOWN PHASE 3 BATHINDA PUNJAB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 3 | Rejected-Finance L3 |
Tender Value
₹73.3 L
EMD Value
₹1.3 L
Closing Date
22 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda, Bathinda Military Station
SPL REPAIR INCL STRUCTURAL REHABILITATION OF BLDG NO P 511 UNDER GE (SOUTH) BATHINDA AT BATHINDA MIL STN
2021_MES_461623_2
CWE BTD 8197/E8
Open Tender
Civil Works
Item Rate
270 days
Bathinda
AS PER NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE (South) Bathinda
₹1.3 L
Yes
18 Jan 2022
1 Nov 2021
24 Nov 2021
1 Nov 2021
22 Nov 2021
8 Nov 2021
1 Nov 2021 - 6 Nov 2021
60 days
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each and removing from site including cutting holes for removal of hold fast complete.
S & F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified in SSR Part -II (2020) and all as shown on drawing of SSR Part-II (2020).
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement all as per instruction and drawing shown for item No 8080 of SSR Part II.
S & F 100mm long aluminium anodized butt hinges fixed with galvanized steel screw..
S & F 150 mm long aluminium anodised, barrel tower bolts of extruded section.
S & F 125 mm long aluminium anodised, handle cast type
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each and removing from site including cutting holes for removal of hold fast complete.
S&F factory made pressed steel frames for door with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc, compete, all as specified of frame size 105 mm x 60mm & thickness of MS sheet shall not be less than 1.25 mm including making holes for fixing hold fast etc complete.
M & L for PCC (1:3:6) type C1 using 20mm graded stone aggregate as in back fillling of chowkhat Complete.
Taking down & refixing in same opening shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each after easing adjusting complete all as specified.
Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each.
S & F 35mm thick factory made panelled shutter (two panel) plain framed with lock rail and panel of 12mm thick veneered particle board with commercial veneering on both faces conforming to IS-3097 exterior grade kiln seasoned and chemically pressure treated of second class hard wood rails and styles and the size of rail and style as per IS-1003 (Part I).
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type), and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, length of bolt 300mm.
S & F 150 mm long extruded section aluminium allow handle fabricated type
S & F factory made steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat primer as directed.
S & F factory made steel ventilator with top hung shutter incl projecting type hinges, steel pegs and stay with glazing bar complete all as directed.
S & F MS framed work such as grills, gratings, etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified.
S & F sheet glass, 4 mm thick ordinary quality and glazing with oil putty or wooden beads in square not exceeding 0.5 Sqm in each pane including provn of glazing pins/spring clips wherever necessary.
S & F 4 mm thick figured glass, pin head type and glazing with oil putty in wooden beads in squares not exceeding 0.5 Sqm in each pane complete.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins / spring clips of size not exceeding 0.5 Sqm each pane complete.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colouras approved, having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including dismantling of any type/ size of shet in roof coverings complete all as specified of Make : M/s Tara Blue scope, M/s CRIL, M/s JSW Steel Ltd.
Demolition of PCC (unreinforced) in ground floor and paving not exceeding 15cm thick (below or above ground floor) and removing the debris upto a distance as directed by Engr-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish to a distance as directed by Eng-in-Charge.
M & L for non skid ceramic coloured tiles, 400 mm x 400mm , 7 to 8 mm thick (square / rectangular) in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles. including 15 mm thick Screed bed or bedding layer in CM (1:6) complete all as specified.
M & L for non skid ceramic coloured tiles, 600 mm x 600 mm, 9 to 10 mm thick (square / rectangular) in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles. including 15 mm thick Screed bed or bedding layer in CM (1:6) complete all as specified.
M & L for machine cut kota stone slab flooring minimum size 450 mm x 450 mm, 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing laid over and including 15 mm thick Screed bed or bedding layer in CM (1:4). Kota stone for steps shall not be more than two pieces of equal size complete all as specified.
M & L for machine cut kota stone slab 18 to 20 mm thick as in riser of steps , skirting , dado and pillar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing laid over and including 10 mm thick Screed bed or bedding layer in CM (1:4) Kota stone for riser shall not be more than two pieces of equal size complete all as specified..
S&F glazed ceramic coloured / printed tiles 450 mm x 300 mm, 7 to 8 mm thick in verticle surfaces such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement pigmented to the match the shade of tiles laid over and including 10 mm thick rendering in cement mortar (1:4) as backing coat and finish the surface rough to receive the tile.
M & L for 40 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring finished even and smooth without using extra cement complete all as specified.
M & L for Glass dividing strip , 3mm thick and 38mm wide inserted in position complete all as specified and as directed.
M & L as in replacement GI tubing, medium grade, 15mm bore with all fittings, fixed to wall or ceiling or laid in floor complete all as specified.
M & L as in replacement GI tubing, medium grade, 20 mm bore with all fittings, fixed to wall or ceiling or laid in floor complete all as specified.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exc 10 cm girth.
S & F as in replacement 500 litres capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as directed.
S & F as in replacement ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 210 gram) complete all as specified.
S & F as in replacement Gun metal globe or Gate valve , with iron wheel , screwed both ends for iron pipe or for unions for 20 mm bore dia of pipe
S & F as in replacement Gun metal globe or Gate valve , with iron wheel , screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe
S&F in repairs bib taps, cast copper alloy with crutch or butterfly handle, fancy type, chromium plated, screwed down, screwed for iron pipe or for brass ferrule for 15 mm bore dia of pipe.
Supply only 15mm bore chromium plated, fancy type, quarter turn Pillar cock screwed down high pressure, with or without lettered Hot ot Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified.
S & F in repairs stop valves / Angle valve, chromium plated, fancy type, quarter turn, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe.
S & F as in replacement PVC connection of length 450 mm, 15 mm size with brass nuts of approved quality.
S & F in repairs stainless steel, tubular towel rail, 20 mm dia, D type, 450 mm long between flanges fixed with CP screws and wooden cleats complete all as specified.
S & F in repairs, stainless steel chromium plated soap tray of size 160 x 160 x 90mm and fixed on wall with chromium plated brass screws complete.
S & F grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gm).
S & F in repairs 32mm dia fancy type PVC coated in wooden finish on MS pipe coloured curtain rod with brackets and knobs at both ends with 6 Nos rings in one meter length as per site requirement complete. Note:- Brackets & Knobs deemed to included in quoted rates. Nothing extra shall be paid on this accouont.
S&F PVC (SWR) 110mm bore pipes single socketed, ISI marked, in any length with rubber ring joints, fixed to walls including taking down old existing pipes of any size or pattern all as directed.
S&F PVC (SWR) 110mm bore bends of any radius.
S & F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor and excluding flushing cistern, flush pipe and waste pipe complete.
S & F as in replacement PVC valve less, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe 32mm dia complete.
S&F in repairs vitreous china wash basin, white, flat back, size 550mm x 400mm, excluding taps, waste, chain and plug and porcelain stopper but including brackets and including cutting for and pinning in ends of brackets or erecting stand complete.
S&F in repairs vitreous china bowl type urinal flat back, size of 465mm x 355mm x 265mm (minimum), white, with including grating with CP urinal spreader and union for discharge pipe, (excluding flushing cistern, flushing pipe, and waste pipe) including providing and fixing plugs, bedding, urinal against wall in cement mortor 1:2, securing urinals to plugs with and including 60mm long brass screws or brackets , pointimng arround urinals back in cement etc and connections to flushing pipe and outpipes complete.
S & F 100 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, laid in trenches or in floor or fixed to walls with and including suitable size clamps including dismantling existing pipes complete all as directed.
S & F 75 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without laid in floor with cement joints including dismantling existing pipes complete all as specified.
S & F in repair 100mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches.
S & F in repairs 75mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches.
S & F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door.
S & F in repairs 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door.
S & F in repairs 75 mm dia cast iron floor trap with chromium plated grating incluing jointing to waste pipe fixed in cement concrete (1:2:4) type B-1, complete all as specified.
Demolition of brick work masonry, built in cement mortar including all quoins, arches, pillars, etc, and removing rubbish to a distance not exc 250 mtr away from the premises complete all as specified.
M & L for Brick work using old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), complete all as specified..
All as per item No 62 but except bricks. Note : Old bricks retrieved from Ser item No 61 will be re-used.
M & L for precast cement concrete (1:3:6) type B-0 using 12.5mm graded stone aggregate in lauvers and jallies, 25mm thick (measured solid), set in cement mortar (1:4) including all mouldings but excluding frame complete.
M&L for 75 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement complete all as specified.
Taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 250 mtr away complete all as specified.
M & L for rendering 15 mm thick on surface other than fair faces of brick work in cement mortar (1:6), finishing the surface even and smooth without using extra cement complete all as specified.
M & L for rendering 15 mm thick in cement mortar (1:4) on brick work or concrete surfaces with using liquid water proofing material @ 200 ml per bag of cement and finishing the surface even & smooth without using extra cement complete all as specified.
M & L for rendering 5 mm thick on concrete surfaces as in ceiling in cement mortar (1:3), finishing the surface even and smooth without using extra cement complete all as specified.
M & L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick walls or concrete surfaces, finished ever and smooth without using extra cement complete all as specified.
M & L for preparing newly plastered surfaces of walls and applying two coats of internal acrylic emulsion paint over a coat of primer all as specified..
M & L for three coats of white washing on newly plastered wall surface including preparation of surface complete all as specified.
M & L for preparation of newly plastered surfaces of external walls and applying the following:- (i) Two coats of 100% acrylic exterior emulsion paint by using airless spray/ roller over and including a coat of external acylic primer. Make:- Apex Brand of Asian Paints/Excel Brand of Nerolac Paints/Berger Weather Coat Note :- Contractor may use manual tools for surface preparation with prior approval of Engr- in- charge in writing in case use of mechanical equipments are not possible.
M & L for preparing newly plastered surfaces of ceiling and applying three coats of white wash all as specified.
Complete removal of existing treatment on wall (any number of layears) by scrapping with steel wire brushes or any other means, including filling depressions of scrapped surfaces and M & L for preparation of old plastered internal surfaces of walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of internal acrylic emulsion paint by using airless spray/ roller over and including a coat of exterior emulsion primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
M & L for preparation of old plastered or unplastered surfaces of walls and apply Two coats of white wash complete all as specified.
Complete removal of existing treatment on wall (any number of layears) by scrapping with steel wire brushes or any other means, including filling depressions of scrapped surfaces and M & L for preparation of old plastered external surfaces of walls and applying the following:- (i) Two coats of weather proof (antifungal) exterior emulsion paint by using airless spray/ roller over and including a coat of exterior emulsion primer. Make:- Apex Brand of Asian Paints/Excel Brand of Nerolac Paints/Berger Weather Coat Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
M&L for preparation of old plastered or previously treated surface and applying one coat of white wash on ceiling complete all as specified.
M & L for preparation of new or previously untreated surfaces of steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M & L for preparation of old steel surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified.
M & L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint on wooden surfaces complete all as specified.
M & L for RCC M 25 design mix (using 20mm graded stone aggregates) as in columns, pillars, piers, posts and struts. (Reinforcement and form work shall be measured and paid for separately)
M & L for RCC M-25 design mix concrete using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves and the like, finished exposed surface fair and even. (Reinforcement and form work shall be measured and paid separately)
M & L for RCC M-25 (Design Mix) using 20 mm graded stone aggregate in lintel over 1.5 M span , beams , cantilevers etc all as specified and directed. (Note - Reinforcement and form work shall be measured and paid separately)
Use and waste of formwork to sides of pillars, posts, struts, piers, columns having square, rectangular or polygonal shape with rough finished surface of concrete.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC /PCC bands in walls, horizontal or sloping and similar work exc 10 cm but not exc 20cm wide with rough finished surface of concrete.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) for flat rough surfaces of concrete.
Use and waste of form work to sides and soffits of floor or roof beams , beams haunching , girder , bressummers , lintel , cantilevers , shelves including supports etc for rough finished surfaces of concrete all as specified.
M & L for TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified.
All as per item No 90 above but TMT bars 8 mm dia ,as in stirrups , spacers & binders all as specified.
Excavation in trenches not exc 1.5 meter wide and not exc 1.5 meter depth for foundation etc or for shafts , wells, cessepits, manholes , septic tank, for laying of cables etc not exceeding 10 Sqm on plan and not exc 1.5 meter depth and getting out in soft/loose soil etc complete all as specified and as directed .
M & L Hard core of gauge not exceeding 63mm , using broken stone or boulder , deposited , spread & leveled In layer not exceeding 15 mm thick watered and rammed to a true surface complete.
M & L 75 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base complete all as specified..
Returning filling in, including spreading , leveling, watering and well ramming in layers each not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus excavated soil to a distance exc 250 mtr but not exceeding 500 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
Dismantling of brick tiles or terracing tiles, single layer on roofs including removing the demolished material not exceeding 250 mtr away from site and disposal off in low lying area as directed.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness recovered or only a part there of) including removing the demolished material not exceeding 250 mtr away from site and disposal off in low lying area complete.
M&L for water proofing treatment over RCC slab by applying oil bound bituminous primer @ 0.25 kg/Sqm and providing and laying 3mm thick APP modified water proofing memberane weighing not less than 3.50 kg/sqm, reinforced with non woven polyester reinforcement matt weighing not less than 160 gm/Sqm polyester core, having soften point not less than 150°C, longitudinal tensile strength not less than 650 N/ 5 cm, tearing strength of 180 N, torch application, side overlap 75 mm and end overlap 100 mm and tucked into the chases applying a coat of solar reflective aluminium paint @ 0.11 Kg/ Sqm on membrance surface all as specified and directed.
M&L for Lime concrete in lime mortar (1:2) using 40 mm graded brick aggregate, laid to slope as directed by Engineer in charge over RCC roofs as padding complete alll as specified. Note: Minimum thickness of lime concrete at lower end shall not be less than 50mm.
M&L for cement concrete tiles 25cm x 25cm x 22-25 mm thick, machine pressed as approved, set, jointed and pointed in neat cement slurry as in roof slab etc; laid over & including 15mm thick screed in CM (1:6), mixed with using liquid water proofing material @ 200ml / bag of cement complete all as specified. Make :- NITCO / PAVIT / M/S ULTRA TILES / M/S SUNSHINE INDUSTRIES. Note:- WPC shall be measured and paid separately.
Supply only liquid water proofing material, ISI marked.
M & L for making benching PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate using liquid water proofing material along the side wall adjoining to roof in concave shape complete all as specified and directed. Note:- WP material shall be measured and paid separately.
Demolition of RCC of any description & in any position not otherwise specifically provided for, complete all as specified.
Cutting holes in brick walls built in cement mortar for inserting hold fast and making good dismantled portion in CM 1:3 or Cement concrete 1 : 2 : 4 , type B1 as required , depth exc half brick but not exc one brick complete all as directed.
S & F for roof trusses ( framed) trussed, purlins, crane gartries, rails and fastening and heavy bracket framing ( Beam, Tee, angles or flat sections) including distance pieces, cleats, hold fasts etc Fe-410-W (Gde-E-250) complete all as specified all as directed.
Providing and erecting adjustable ( Jack type ) steel props (up to full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work at the distance of 1.20 mtr centre to centre and maintaining them in position till required i.e demolition of RCC members, recasting & setting of concrete all as directed by Engr-in-Charge.
Chipping of unsound weak and cracked concrete/ cover of reinforcement over RCC member or as per site requirement up to minimum half depth of bars by chieseling incl all required scaffolding/ ladders and disposal of the debris out side of MOD land complete all as specified.
Cleaning of existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material etc, complete and applying two coats of alkline rust converting primer Sika Rust off-100 or equivalent on the existing rebar and allowing it to react with rust for 6 hours form corrosion resistant, insoluble and adherant protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls with time interval of 1 hour between the coats incl all required scaffolding / ladders complete all as specified as per manufacturer's instructions and directed (Girth of RCC member shall be measured).
Providing and application of zinc rich epoxy anti-corrosive protective coating for rebar corrosion protection system in 2 coats (of 0.4 kg/Sqm each approx) complete all as specified and directed. The product should confirm carbonation resistance of 2mm and bond strength > 1N/Sqmm according to ASTM C-882-78 incl all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed (Girth of RCC member shall be measured)..
Providing, mixing & applying two components Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer specification with Sikadur-32 LP in consumption of 0.4Kg /sqm. The product should comply with ASTM C-881 Type II Grade 2 Class B+C and bond strength should be 10 MPa, including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed (Girth of RCC member shall be measured)..
Rebuilding the section of damaged RCC elements to its original size in thickness in layer of 10 mm each by providing and applying with pre-batched, one component fiber reinforced cementitious patch repair mortar Sika Mono Top -122 F or equvalent as approved by GE in writing for makes as per Appx 'B' having compressive strength >= 50N/Sqmm (28 days) according to ASTM C 109 : Flexural strength >= 5N / Sqmm (7 days) according to ASTM C 293-79, including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed.
(a) 10 mm average thickness in 1st layer.
(b) Add for each additional 10mm uniform thickness.
Providing & fixing rebar of required length & diameter with Sika Anchor Fix(R)-3+/Mungo / Fischer FISV 390 / Hilti RE-500 Epoxy resin where ever required in RCC members including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled with epoxy to ensure the bond as per manufacture recommendation complete as per site requirement including all required scaffolding / ladders following :-
(a) 10 mm to 16mm ( Dia of reinforcement ) x 100 to 160 mm embedment depth.
(b) 20 mm to 25mm ( Dia of reinforcement ) x 200 to 250 mm embedment depth.
Rebuilding the section of damaged RCC elements to its original size in thickness of 100 mm by providing and casting with ready to use non shrink, cementations free flow micro-concrete SikaRep Microcrete-4 or equivalent as approved in writing by GE from makes as per Appx 'B' having compressive strength > 60 N / Sqmm (28 days) according to ASTM C 1107-99 including providing and fixing of watertight foam faced finish shuttering of minimum 18 mm thickness and supporting formwork, all lead fit, mixing, placing, deshuttering, leveling the surface by grinding off cementations slurry or cementitious joints differences if any for satisfaction of Engr-in-Charge and curing thereof including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed.
Making 'V' groove of 5 mm wide and 5mm deep over crack line by electrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower and sealing of exposed 'V' groove of 5mm deep and 5mm wide with solvent free, moisture tolerant thixotropic, two part structural adhesive and repair mortar, based on epoxy resins and special fillers, designed for use at temperatures between +10ºC and +40ºC, Sikadur-31(N) or equivalent having conforms to ASTM C-881-78, Type I, Gde 3, Class B+C compressive strength > 60 N / Sqmm (14 days) according to ASTM C 881: bond strength > 10 N / mm ² (7 days) according to ASTM C-882 including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed.
Drilling holes of 12mm dia upto 100 mm deep holes in structural members at the interval of 300mm in staggered manner or along the crack line in reinforced concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatitable with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix it inside the hole by applying thixotropic epoxy putty Sikagard-694 F(I) or equivalent to ensure complete sealing and allow to cure the system for minimum of 8 hrs before Grouting including nozzle projections, excess putty, if any, over concrete element remove by gridding , leveling and finishing the external surface after completion of the work etc including all required scaffolding/ ladders complete all as specified as per manufacturer's instructions and directed.
Grouting injecting two part, low viscosity, moisture insensitive injection- liquid, based on high strength epoxy resin Sikadur -52 LP(IN) or equivalent by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having mixed density 1.1 kg/Ltr (at + 27ºC) : Viscosity -250 m Pass at + 30ºC and should comply according to ASTM C 881 Type II and IV , Grade-I , class E+F and should have following properties. Compressive strength >= 70 N/Sqmm (7 days) according to ASTM C 579 : Tensile strength -50N / Sqmm (after 7 days at +30ºC cure) according to ASTM D 638 : Tensile modules- 2000N / Sqmm (after 7 days at +30ºC cure) according to ASTM D 638, Bond strength -10.8N / Sqmm (failure in concrete ) (after 14 days at +30ºC cure ) according to ASTM D 638 : Bond strength : Flexural strength -50 N / Sqmm according to ISO 178. Seal the nozzle with Sikadur 31 or equivalent thixotropic epoxy putty after the refusal of grout material from the nozzle. Note :- Leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost including all required scaffolding/ ladders complete all as specified.
Making 'V' groove of 6 mm wide and 6mm deep over crack line in brick walls by electrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower as directed by Engr-in-Charge including all required scaffolding/ ladders complete all as specified.
Supply and apply of rust non shink repair mortar for non- moving cracks in plaster and walls. Product : Sika Cracksil/ Master race 2200 / Fosroc Consumption : 25 RMT/Kg for crack size of 600 x 6mm Density : 0.85 Kg/Ltr at 27ºC
Supply and apply ready to use water resistant white cement based finishing/ smoothening material in 1.5 mm thickness for indoor and outdoor on repaird surfaces. Product : Sika @ Wall decor or Master Seal 550/551 or Fosroc Coverage :- 1.5 Kg powder /Sqm System Requirement : Tensile Adhesion . 1.0 N / Sqmm (after 28 days) ( according to EN-1348), water capillary Absorption 0.8 ml at 24 hrs as per Karsten Tube Test, water Retentivity> 98% ( According to EN-196-3) Note:- (i) The work under ser items 107 to 124 of BOQ shall be got executed by contractor through specilized agency as approved by Accepting Officer.(ii) Schedule 'A' notes and particular specification-II for execution of work for sri item No. 107 to 124.
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, light fittings etc including concealed conduit and sunken boxes and removing the retrieved materials from site including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed.
M & L for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia (medium duty ISI marked) and conduit fittings with and including 3 mm thick bakelite laminated sheet top cover for one fan / light / exhaust fan controlled by one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 126 here in before but for socket outlet 5 pin, 6 Amp on same board complete all as specified.
All as per item No. 126 here in before but for socket outlet 5 pin, 6 Amp on independent board but not below the switch board complete all as specified .
All as per item No 126 above but for one light point controlled by two , two way switches .
All as per item No 126 here in before but for one socket outlet 6 pin, 6/16 Amp multipurpose 2 in 1 on independent board with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable including provision of 2.5 Sq mm PVC insulated solid copper conductor FRLSH cable continues as earth wire connected to earth dolly, conductor etc.
S & F switch piano flush type 5/6 Amp 230V AC one way complete as specified.
S & F switch piano flush type 5/6 Amp 230V AC two way complete as specified.
S & F Switch paino type, flush type, single pole, one way, 15/ 16 Amp .
S & F socket, outlet , 2 in 1, 3 Pin, 5 Amp, flush type. (Note: Switch and socket shall be of same make.)
S & F socket, outlet , 2 in 1, 3 Pin, 5/15 Amp, combined flush type. (Note: Switch and socket shall be of same make.)
S&F, fan regulator electronic step type (1-5), socket type 230-240 Volt, AC supply, complete all as specified and directed.
S & F ceiling rose, 3 plate, surface bakelite type, Polycorbonate body, 6 Amps, 250 Volts AC, 65 x 50 mm, three terminal (ISI marked) complete all as specified.
S & F Lamp holder of PVC/Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb, B-22 complete.
M & L for sub main wiring with 3 single core cable PVC insulated unsheathed of copper multi standard conductor FRLSH cable of size 6 sqmm, 1100 votls grade drawing through in and including PVC concealed conduit 20 mm dia medium duty including accessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:6) and finishig the surface to match with existing surface etc including taking down old unserviceable wiring 6 Sqmm complete all as specified. Note:- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring with 3 single core cable PVC insulated unsheathed of copper multi standard conductor FRLSH cable of size 10 sqmm, 1100 volts grade drawing through in and including PVC concealed conduit 25 mm dia medium duty including accessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 10 sqmm unsheathed multistranded FRLSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:6) and finishig the surface to match with existing surface etc including taking down old unserviceable wiring 6 Sqmm complete all as specified. Note:- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, 12 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc complete including taking down old DBs all as specified.
S&F factory made loadline vertical type TPN DB 4 way double door, protection class IP-43 made out of CRCA sheet with 200 Amps rated copper busbar, neutral and earth link, blanking plates, locking arrangemen and including 63 Amps 4 Pole MCCB as incomer complete all as specified and directed including taking down old DB complete.
S & F MCB SP 6 to 32 Amps 10 KA 'C' series complete all as specified.
S & F MCB SPN 40 to 63 Amps 10 KA 'C' series complete all as specified.
Supply and fixing LED light fitting 1 x 20 watt , 220 Volt, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
S & F LED mirror light fitting of 09 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete including 09 watt tube rod make all as Model No LCL- 9-CDL of Crompton or equivalent model of approved make from list of make attached in tender documents including connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size complete including taking down old fittings all as directed.
S & F energy efficient LED street light fitting of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, PF > 0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 25 watt LED lamp with GI brackrt - 01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as per SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appx 'B', Cat Part No. as approved by GE complete including taking down old fittings all as specified
M & L in replacement for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note :- (a) PCC chamber shall be constructed at least 1.5 m away from earth pit. Pipe for watering shall be provided in slanting manner. (b) 4mm dia GI wire and 15mm dia light grade GI protection pipe upto 7.5 metre shall deemed to be included in quoted rate.
Taking down serviceable/ unserviceable ceiling fans 1200/ 1400 mm sweep 230 V, AC, single phase from its original position, dismantling the ceiling fan and carryng out minor repairs works including throughly cleaning all components of fan including oiling, varnishing the fan with and including replacement of rusted / unserviceable nuts, bolts, split pin, rubber reel, capacitor 2.5 MFD , flexible twin core copper cable of size 23/.00076 approximate one metre lenght for each fan, machine screws and painting the fans and writing the MES No etc and refixing the repaired fan to its original position after completion of repairs works of building (B/R portion) complete all as specified and directed. Note:- Ceiling fans will be deposited to store yard of AGE E/M after taking down and repairs and same will be refixed to its original position after repair work of building (B/R portion). necessary RV/IV shall be made and kept on record.
Single pole and neutral enclosure 240 volts with two pin and earth plug and socket with one single pole MCB 20 Amp for AC connection complete all as specified
S & F surface mounted pressure die-cast aluminium luminair in powder coated white finish in square surface mounted LED flat panel with replaceable electronic driver with LED 36 Watt , 6000 K as per Cat Part No BZSSQL 36W WH of Bajaj or equivalent make as mentioned in list of make APPDX 'B' including connecting electric connection, including taking down existing old fitting any type complete all as specified.
SHARDA ENTERPRIES
SACKSON ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .