Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC NO 1C CHROMPET KANCHIPURAM TAMIL NADU 600044 INDIA | CHENGALPATTU | TAMIL NADU | 600044 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹29.6 L+₹1.1 L (4.02%)Rejected-Finance OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹31.1 L+₹2.6 L (9.30%)Rejected-Finance NO 6 1 ALAGAR PERUMAL KOIL MAIN STREET VADAPALANI CHENNAI 600 026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹31.3 L+₹2.9 L (10.3%)Rejected-Finance 25A R R SAMY LANE COIMBATORE TAMILNADU COIMBATORE TAMIL NADU 641009 | COIMBATORE | TAMIL NADU | 641009 | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹33.2 L+₹4.8 L (17.0%)Rejected-Finance 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
30 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer(I) (CG) Chennai
Garrison Engineer(I)(CG), Military Engineer Services, P-16,CGRA Meenambakkam 4th Street ,NGO Colony, Nanganallur, Chennai-600 061
ADDITION/ALTERATION AND REPLACEMENTS OF LT UG CABLES AT CGRA AND OTM AT TUTICORIN UNDER GE (I) (CG) CHENNAI
2024_MES_673175_1
8153/E8
Open Tender
Electrical and Maintenance Works
Item Rate
122 days
ICGS TUTICORIN
As per Tender Documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I) (CG) Chennai
₹83,000
Yes
15 Jan 2025
9 Sept 2024
2 Oct 2024
9 Sept 2024
30 Sept 2024
16 Sept 2024
9 Sept 2024 - 13 Sept 2024
Amount
Supply, laying, fixing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm, 4 core complete all as specified and as directed by Engineer-in-charge.
Supply, laying, fixing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm, 4 core complete all as specified and as directed by Engineer-in-charge.
Supply, laying, fixing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm, 4 core complete all as specified and as directed by Engineer-in-charge.
Supply, laying, fixing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sqmm, 4 core complete all as specified and as directed by Engineer-in-charge.
Supply, laying, fixing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sqmm, 4 core complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repairs 125A MCCB 4 Pole, 415V, 16 KA rating complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs 100A MCCB 4 Pole, 415V, 16 KA rating complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs 63A MCCB 4 Pole, 415V, 16 KA rating complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for foundation etc, in soft / loose soil complete all as specifed and directed by Engineer-in-charge.
Returning, filling in layers n. exc. 25 cm thick including spreading, levelling, watering and well ramming in soft/loose soil complete all as specifed and directed by Engineer-in-charge.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specifed and directed by Engineer-in-charge.
Supply and laying of size 50mm inner dia DWC High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches complete all as specified and as directed by Engineer-in-charge.
M&L for attending any breakdown in LT UG cable by Excavating, Returning filling, Removing and fix the heat shrink cable join kit of 6-16 Sqmm 4 core complete all as specified and as directed by Engineer-in-charge.
M&L for attending any breakdown in LT UG cable by Excavating, Returning filling, Removing and fix the heat shrink cable join kit of 25-50 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-charge.
M&L for attending any breakdown in LT UG cable by Excavating, Returning filling, Removing and fix the heat shrink cable join kit of 70-120 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-charge.
M&L for attending any breakdown in LT UG cable by Excavating, Returning filling, Removing and fix the heat shrink cable join kit of 150-185 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-charge.
M&L for attending any breakdown in LT UG cable by Excavating, Returning filling, Removing and fix the heat shrink cable join kit of 240-300 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-charge.
Supply and fix heat shrinkable sleeves over bare conductor of LT cable of suitable size as per site after disconnecting cable from terminal box complete all as specifed and as directed by Engineer-in-charge.
Supply and laying factory made unreinforced precast concrete cable cover, class HVP, type 2 with peak, manufactured with concrete grade not lower than M20 grade, size 450mm x 180mm x 40mm for protection of LT cable laid length wise prependicular to the axis of cable complete all as specified and directed by Engineer-in-charge.
Supply, lay /spread in trenches, M-sand including cleaning, spreading, levelling, punning for laying /cushioning of cable all as specified and as directed by Engineer-in-charge. Note: Punning thickness shall be measured and paid.
Supply and laying of Cast iron pipes with spigot and socket ends centrifugally cast. Class LA, of size 200mm, laid in trenches, complete all as specified and directed by Engineer-in-charge.
M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortor 1:4 complete all as specified and as directed by Engineer-in-charge.
M & L for precast cement concrete in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortor 1:4 Type B1 1:2:4(20mm graded aggregate) complete all as specified and as directed by Engineer-in-charge.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-charge.
Material & Labour for cutting of bituminous road surface at 45cm width and in required depth not less than 60cm using road cutting machine complete all as specified and directed by Engineer-in-charge.
M&L for Cement concreting of type D2, 1:4:8 (40mm graded aggregate) 100mm thick all as specified and directed
M&L for Cement concreting of type B-1, 1:2:4 (20mm graded aggregate) 40mm thick all as specified and directed
Supply and fix MCB SP of rating 10A C-curve complete all as specified and directed.
Supply and fix in repairs GI tube, light grade 50mm dia for fixing of street lights including clamps,nut bolts etc bend to shape complete all as specified and as directed.
Supply and fix Sintex box of size 250 x 200 x 105, 3 phase 4 terminal long connector along with MCB fixing channel complete all as specified and directed. Make: Sintex Code No. GSJB-2520 or equivalent
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-charge.
M&L for Point wiring with 1.5 Sqmm (Nominal area) PVC insulated Unsheathed cable FR grade with copper conductors, single core, multi stranded 1100 Volts ISI Marked (IS 694) drawn in PVC casing & caping ISI Marked heavy grade accessories for one light point controlled by one one modular switches etc, complete all as specified and directed by Engineer-in-charge.
M & L for Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 (1mx1mx2m depth excavation, removal, & concreting shall be measured & paid separately) complete all as specified and as directed by Engineer-in-charge.
Dismantling concrete poles/ struts, any size and setting aside complete all as specified and directd by Engineer-in-charge
M & L for Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 (1mx1mx2m depth excavation, removal, & concreting shall be measured & paid separately) complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches not exc 1.5m wide and exc 1.5m depth for foundation etc, in soft / loose soil complete all as specifed and directed by Engineer-in-charge.
Cement concrete in foundations, filling and mass concrete, type B-2, 1:2:4 (40mm graded aggregate) for pillars and posts (including caps and bases) all as specified and directed by Engineer-in-charge.
Providing cement concrete of Type B1, 1:2:4 (20mm graded aggregate) for Ditto, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by Engineer-in-charge.
NAVEEN ENTERPRIESES (BID ID -3107915)
Veera Electrical (BID ID -3121835)
rvelectricals (BID ID -3119136)
S KUMARAN (BID ID -3107474)
SIRITEL SYSTEMS PRIVATE LIMITED (BID ID -3107969)
PHEJAYS AGENCIES (BID ID -3121591)
KRA Engineering and Construction (BID ID -3109012)
VVM CONSTRUCTIONS (BID ID -3107985)
OM Muruga Enterprises (BID ID -3122008)
M/S VIGNESH POWER SYSTEM (BID ID -3107222)
Sri Lakshmi and Company (BID ID -3122502)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .