Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
6 Aug 2026, 2:00 pmClosed
Executive Engineer ED-III
Office of Executive Engineer ED-III
Augmentation of 250 KVA to 630 KVA Distribution Substation at Neelam colony near Subash Nagar Petrol Pump within the jurisdiction of Electric Division-III, Sub Division-II Janipur, Jammu on turnkey basis under UT Capex. Scheme Code PDDSS2627100493
2026_PDD_316701_1
ED-III/Jammu/26 of 2026-27
Open Tender
Electrical Works
Item Rate
30 days
Jurisdiction Of Electric SD Janipur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer ED-III
₹45,000
12 Aug 2026
18 Jul 2026
7 Aug 2026
18 Jul 2026
6 Aug 2026
20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Augmentation of 11/0.433kV, 250KVA to 630 KVA Distribution Substation at Neelam colony near Subash Nagar Petrol Pump within the jurisdiction of Electric Division-III, Sub Division-II Janipur, Jammu on turnkey basis | |||||
| 1.01 | 11/0.433 KV, 630KVA ,3 Phase Distribution Transformer with Bi-mettalic Terminal Connectors Energy Level-2( Alluminum wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings), and with LV Cable Box Having detachable Aluminium Gland plate . (Write back/ carriage of dismantled 250KVA Distribution transformer to divisional store.The bill will be considered only after the Write back Indent from Divisional Store.) | 1 | No | - | - |
| 1.02 | 400mm2 (2Ckt ) Single Phase Cable, 1.1KV Grade, PVC Insulated Stranded Conductor FRLS type | 44 | Mtr | - | - |
| 1.03 | Construction of cement concrete platform (10'x10'x6') ft for 630 KVA station as per standards. | 1 | No | - | - |
| 1.04 | LT Distribution Box for 400 KvA DTR with MCCB for incomer and Switch Fuse Units for outgoing circuits.. | 1 | No | - | - |
| 1.05 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. | 3 | No | - | - |
| 1.06 | 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type | 1 | Set | - | - |
| 1.07 | 11KV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | - | - |
| 1.08 | Steel Of Sorts | 100 | Kg | - | - |
| 1.09 | Gapless Surge Arrestor, 9KV, 10KA, LA with Polymer housing stn. Type | 1 | Set | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.63 MB
Tendernotice_2.pdf
PDF • 1.86 MB
BOQ_1034443.xls
BOQ • 0.27 MB
GTP.pdf
Tender Documents • 7.50 MB
RECDrawings.pdf
Tender Documents • 3.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .