Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹7.7 L+₹16,851.07 (2.22%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.9 L+₹33,124.70 (4.37%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹7.9 L+₹35,193.75 (4.64%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹8.0 L+₹40,329.43 (5.32%)Rejected-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
31 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jammu
HQ CWE Jammu pin 900172 C/o 56 APO
REPAIR AND MAINT GOD LIGHTENING ARRESTOR AND ALLIED WORKS UNDER AGE E and M MH UNDER GE SATWARI
2021_MES_454610_1
CWE/JP-21/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR G E Satwari
Class E, Cat b(ii)
9 documents required · 9 mandatory
₹500
G E Satwari
₹20,000
Yes
28 Aug 2021
25 Jun 2021
7 Aug 2021
25 Jun 2021
31 Jul 2021
17 Jul 2021
90 days
Amount
Supply and fixing in repairs gang operated air break switches, triple pole, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level Vertical type for rating upto 200 Amps, 11000 volts complete with GI operating pipe of heavy duty, complete all as specified and as directed
Supply and fixing in repairs gang operated air break switches, triple pole, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level Vertical type for rating upto 400 Amps, 11000 volts complete with GI operating pipe of heavy duty, complete all as specified and as directed
Taking down and repairing, overhauling, greasing of gang operated air break switches, triple pole, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level horizontal mounting double break rotating type complete with 9 insulators, 33000 volts complete with GI operating pipe of heavy duty, complete all as specified and as directed.
Supply and fixing in repairs drop out fuse assembly complete set with insulator-02 Nos and connected accessories for 11000 Volts grade of 200 Amps capacity, complete all as specified and as directed.
Supply and fixing in repairs drop out fuse assembly complete set with insulator-02 Nos and connected accessories for 33000 Volts grade of 200 Amps capacity, complete all as specified and as directed.
Taking down and repairing/overhauling of air break gang operated switch with DO fuse unit 11 KV rating 200 Amp/400 Amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically / horizontally , replacement of broken/worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after repair including proper allienment complete all as directed. (Note:- Warn out component of GOD/ insulators / ASCR shall be measured and paid separately in respective items)
Supply only Female contact or fixed contact capacity 200 A 11 KV heavy duty and high conductive metal, complete all as specified and as directed.
Supply only male contact or moving contact of capacity 200 Amp 11 KV heavy duty and high conductive metal, complete all as specified and as directed.
Supply only tinned copper flexible jumper 200A 11 KV rated, complete all as specified and as directed.
Supply only fixed top contact & Fixed bottom contact 11 KV 200 Amp for DO fuse unit, complete all as specified and as directed.
Supply only Fiber glass tube 200 amps with metalic fittings both ends suitable for DO fuse 11KV, complete all as specified and as directed.
Supply only mild steel jumper carrier as per sample, complete all as specified and as directed.
Supply only back connector plate as per sample, complete all as specified and as directed.
Supply only post insulator 11 KV as per sample, complete all as specified and as directed.
Supply and fixing in repairs lightening arrestor expulsion high tension type complete with all fittings, transmission class, discharge 65 kilo Amp suitable for 11 KV system pole mounting type conforming to IS - 3070 Part-I, complete all as specified and as directed
Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed with and including dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed by EIC.
Steel tubular pole swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 Mtr long), complete all as specified and directed.
PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundation and mass concrete/filling, complete all as specified and directed.
Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete, complete all as specified and directed .
PCC 1:2:4 type B-1 using 20mm graded stone aggregate in coping and the like including weathering slightly rounded/chamfered angles with & incuding necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for HT size 25 X 20 cm and taking out of us one, complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT, size 20 x 15 cm and taking out of us one, complete all as specified and directed.
Anti climbing devices, spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, and washers and welding in two halves made to shape to suit the cross-sectional of the pole, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected ot galvanised iron strip of size 32 x 6 mm earth lead by means of bolt, nuts, washers of galvanised iron or steel, earth strip protected by and including GI pipe 40mm dia bore (light grade) and connected to main test point as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:1½:3) type A-1 cover slab of size 54 x 54 x 5 cm reinforced with 8mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 5 of SSR Part-I and testing complete all as specified and as directed.
Earth continuty conductor or main earthing lead fixed to wall on batten or recess or cheses or buried in groung or drawn in conduit/ pipe or fixed to pole or any other indicated situation for looping earthing etc. as required by 25 X 4 mm GI strip, complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagoanl head screw, complete all as specified and directed.
Supply and fixing in repairs horn gap fuses 11 KV polymeric type, set of 2 insulators, of currenr rating upto 100 Amp all as specifed including taking down old unserviceable fuses, complete all as specified and directed.
Supply only drop out fuses element in copper material of rating 5 Amp to 40 Amp HT 11 KV, complete all as specified and directed.
Supply only barrel fuses of current rating 10 Amp to 40 Amp pin type suitable for HT 33/11 KV, complete all as specified and directed.
Detection of earth fault in under cable HT 11000 volt in any size below GL depth not more than 1.5 Mtr all as specifed and directed. (Cost included necessary T&P for detecting of cable fault below ground), complete all as specified and directed.
Supply laying & testing XLPE insulated, Armoured, electric cable heavy duty with alumimium conductor 11000 volt (E) grade of size 240 Sqmm x 3 core, complete all as specified and directed.
Supply laying & testing XLPE insulated, Armoured, electric cable heavy duty with alumimium conductor 11000 volt (E) grade of size 120 Sqmm x 3 core, complete all as specified and directed.
Supply laying & testing XLPE insulated, Armoured, electric cable heavy duty with alumimium conductor 11000 volt (E) grade of size 95 Sqmm x 3 core, complete all as specified and directed.
Cable jointing kit, heat shrinkable type including all jointing material & accessories suitable for 11000 Volt Cable aluminium conductor XLPE cables straight through joint suitable 50 to 95 Sqmm 3 core cables, complete all as specified and directed.
Cable jointing kit, heat shrinkable type including all jointing material & accessories suitable for 11000 Volt Cable aluminium conductor XLPE cables straight through joint suitable 120-185 Sqmm 3 core cables, complete all as specified and directed.
Cable jointing kit, heat shrinkable type including all jointing material & accessories suitable for 11000 Volt Cable aluminium conductor XLPE cables straight through joint suitable 240-400 Sqmm 3 core cables, complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade for outdoor termination heat shrinkable type including all jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade for outdoor termination heat shrinkable type including all jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade for outdoor termination heat shrinkable type including all jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm all as specifed and directed.
LED solar street light fitting 30/36 watt including galvanised steel pole of length 5 to 6 metre in built, lithium ion battery of capacity 36Ah with and including solar panel not less than 70 watt, LED life not less than 50000 hours with and including charge controller with dusk down sensor, complete all as specified and directed.
Bus bar chamber outdoor pedestal type,factory made,powder coated made out of 3.15 mm thick CRCA sheet of size 750x600x500mm deep with aluminium . Bus bar 400 Amps 3 phase 4 wire system front & back openable double door including grouting with neccessary material, complete all as specified and directed.
HT Panel 11 KV outdoor type made out of CRCA sheet 3mm thick of size 1.2 m x 1.2 m x 1.2 m having legs made out of angle iron of size 50 x 6mm 1.2 m long grouting in the PCC upto 60cm. HT panel having inslators of 11000 volts to accommodate incoming and out going HT Cable of any size including locking arrangements and painting of angle iron with two coats of synthetic enamelled paint over a coat of red oxide, complete all as specified and as directed.
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5m in depth for laying of cables & foundation of poles ,stay assembly and getting out in hard/dense soil, complete all as specified and directed .
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of pipes etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft loose soil, complete all as specified and directed .
Returning filling in, trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil, complete all as specified and directed .
Removing excavated surplus materials to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed .
Supply and spreading sand Dry cushioning to cable providing with a layer of sand 8cm deep before laying the cable and 15cm deep after laying and stretching the cable in trenches, punned thickness shall be measured, complete all as specified and as directed.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed .
M/S SHREE KRISHANA ENERPRISES
M/S ASHOK KUMAR SURI
LAL CONSTRUCTIONS
SATISH AND CO
M/S S K Electricals Regd
R K BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .