Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 CrAccepted-AOC 129 DEEPAK SOCIETY CHUNABHATTI KOLAR ROAD BHOPAL 462016 MADHYA PRADESH | BHOPAL | BHOPAL | MADHYA PRADESH | 462016 | ₹19.9 Cr | L1 | Accepted-AOC Accepted-Financially |
| 2 | L2₹21.8 CrRejected-AOC | ₹21.8 Cr | L2 | Rejected-AOC Not Accepted-Financially |
| 3 | L3₹22.0 CrRejected-AOC | ₹22.0 Cr | L3 | Rejected-AOC Not Accepted-Financially |
| 4 | L4₹23.2 CrRejected-AOC | ₹23.2 Cr | L4 | Rejected-AOC Not Accepted-Financially |
| 5 | L5₹23.7 CrRejected-AOC | ₹23.7 Cr | L5 | Rejected-AOC Not Accepted-Financially |
Updated dates
Tender Value
₹24.8 Cr
EMD Value
₹34.8 L
Closing Date
3 Feb 2026, 5:30 pmClosed
General Manager (Commercial)
Bridge and Roof Co. (India) Ltd Kankaria Centre (4TH/5th Floor) 2/1 Russel Street Kolkata 700 071
SUB-HEAD- Civil Work including PEB Work, Electrical Work, Sanitary and Plumbing, HVAC Work, Water Supply, Sewage, Fire Fighting and other Allied Works etc
2026_BandR_892915_1
B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01
Open Tender
Civil Works
365 days
NATRAX INDORE
Please refer to Tender Document for Details
13 documents required · 13 mandatory
₹59,000
Bridge and Roof Co.India Ltd
₹34.8 L
B and R Co.(I) Ltd.,North Zonal office,New Delhi
12 May 2026
7 Jan 2026
4 Feb 2026
7 Jan 2026
3 Feb 2026
19 Jan 2026
15 Jan 2026
EMC/EV Lab Building
Civil Work
Electrical Work , Fire Alarm & Detection System
Fire Figting Work
Plumbing work
HVAC Work
Compressed Air work
Overhead / Rail Gantry Crane & Lift work
Upgradation of Powertrain lab
Civil Work
Electrical Work
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Please Enable Macros to View BoQ information
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01, DATED 07.01.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Carriage of Excavated earth by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KM complete.
Carriage of Excavated Rock by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KM complete.
Supplying and filling in plinth with sand under floors including, watering, ramming consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil.
Supplying chemical emulsion in sealed containers including delivery as specified
Anti termite treatment
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Excavtion,Transport and Filling in plinthwith local earth / moorum avaiable insite barrow area with in any where in the campus (free from clay ) in layer not exceeding 20 cm in depth , breaking clods watering ,*olling each layer with1/2 tonne rollar or wooden or steel hammers and rolling every 3rd and top most lare with power of minimum 8 tonnes lead upto 50m and lift up to 1.5 m
(Carried Over to Summary of Civil Works)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
Centering and shuttering including strutting, propping etc. and removal of form work for :
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
(Carried Over to Summary of Civil Works)
Centering and shuttering including strutting, propping etc. and removal of form for :
Under 20 cm wide
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
(Carried Over to Summary of Civil Works)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength inn foundation, below plinth level and super structure above plinth level up to floor V level in :
Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth upto floor V level.
(Carried Over to Summary of Civil Works)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete.
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. 8 mm thick Granite of any colour and shade
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
(Carried Over to Summary of Civil Works)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium handles of approved make anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessry screws etc. complete.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with commended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120 gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/sqm. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of size 100x89x3 mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge. (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire rating conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3 mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredited labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
(Carried Over to Summary of Civil Works)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Profile B
Fixing with adjustable lugs with split end tail to each jamb.
Profile C
Fixing with adjustable lugs with split end tail to each jamb.
(Carried Over to Summary of Civil Works)
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing to treads of steps of marble / granite stone.
Extra for marble / granite stone flooring in treads of steps and risers using single length up to 2.00 metre.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Providing and use of Floor Hardener (FOSROC) as per site requirement / client instructions
Providing and Laying 3 mm thick epoxy screeding consisting of araldite GY 257, 100 parts by weight hardener HY 830,40 parts by weight hardener,HY850,20 parts by weight plus quartz sand 900 parts over a primed surface with primer araldite GY 257,100 parts by weight and hardener HY840,50 parts by weight including application of two coats based on araldite GY257,100 parts hardener HY830,40 parts hardener HY 850,20 parts and flow control agents 1 to 3% with acrosil DTO 75, 3 parts complete as per Ciba Geigy specification including pereparation of surface to recived the treatment and top layer finished polimer based epoxy to withstand the indestrial load and weare and teare complete as per the direction of engineer in charge.
Providing and laying non-expansive cement based grouting material (SIKA 214SP or equivalent)including centering and shuttering etc.complete as par manufractures specification and direction of Engineer-in-charge.
(Carried Over to Summary of Civil Works)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.
Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3 mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).
(Carried Over to Summary of Civil Works)
12 mm cement plaster of mix :
15 mm cement plaster on rough side of single or half brick wall of mix :
6 mm cement plaster of mix :
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
Applying priming coat :
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
(Carried Over to Summary of Civil Works)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50metres lead.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge.
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.
(Carried Over to Summary of Civil Works)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed echanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Glazing and paneling to be paid for separately) :
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Filling the gap in between aluminium frame and adjacent RCC/Brickwork/ Stone Work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately).
Providing and fixing Stainless steel 304 Grade H- type pull handle of size min 32 mm dia and 1200mm long of approved make including SS screws, including making holes of required size in shutter etc. complete as per direction of Engineer-in-Charge.
Providing and fixing SS Bottom patch Lock with cylinder of approved make including necessary screws etc. all complete.
Providing and fixing SS floor mounted half dome door stopper of dia 45mm including necessary screws etc. all complete.
External Structure Glazing
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels including:
This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design checked and all the shop drawings vetted by the Principals of the structural glazing system.
The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc., all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc., all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in- Charge.
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately.
(Carried Over to Summary of Civil Works)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :
(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :
(Carried Over to Summary of Civil Works)
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.
(Carried Over to Summary of Civil Works)
Providing erection, and commissioning of Pre-Engineered Building systems with the following Design including validation of design through IITs (any), Manufacture, supply and erection of Factory made builtup Structural steel work using HR plates of minimum 6mm thick , beams, angles, channels, M.S. rods, confirming to IS 226, 2062 grade A/B (weldable) sections with approved welding with electrodes confirm to IS: 814, including cutting, hoisting, fixing in position and applying a coat of epoxy primer (surface preparation with nuts and bolts and washers confirming to IS: 1364 & IS: 1367 clause 4.6 in sections, columns, beams, rafters, bracings, cladding, crane girders, rod sections, steel ladders, suspended platform, insert plates and base plates, stair- case etc. complete as per the fabrication and errection tolerence. All primary and secondary members (dynamic loading) nuts bolts and washers shall be confirmed as per IS standards. The contractor should submit shop fabrication and erection drawings along with the sequency of work and methodology of construction for approval before commencement of work. All other accessories and systems required for total habitutal building shall be included in the building/rates quoted (for all other details refer detail TCC & Annexure and also to be read with in conjunction with Technical specifications) Rates quotes for entire PEB dust free system includes scaffolding, all types for taxes, safety etc.,
Built up sections with 250 mpa/345 mpa plates of varying thickness with minimum plate thickness of 6mm: Providing, fabricating, transportationand errection as per specifications and fabrication drawings, members for all types of structure and for all heights & at all levels including provision of necessary erection high tensile fasteners, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary operations such as but not limited to preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding etc. complete. All main component like column, rafters, crane beams manufactured on automated machines as per standards cutting, grinding, using CNC machines etc., complete specifications read in conjunction with technical specifications required to complete dust free building systemsas per design.
SECONDARY SECTIONS/Cold formed sections with 345 mpa of minimum thickness 2 mm: Providing, fabricating, transportation and errection in position 345 mpa cold form sections used as purlins, girts eaves struts etc., along with necessary fixtures clips, fasteners closures etc., complete specifications read in conjunction with technical specifications required to complete dust free building systems as per design..
Hardware: high tensile fastener conforming to relevant IS codes & ASTM standards etc. complete as per design.
Providing and fixing PUF insulated continuous sandwich panels for wall of total thickness not less than 50 mm or 40mm (as specified) and width 1.0m, made out from continue line method on automatic plant. Panel shall have precoated GI sheet on both side of Polyurethane foam confirming to IS12436:1988. The precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per IS:277, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The panels shall be vertically joined together by tongue and groove joints. The PU foam shall be self- extinguishing, fire retardant type having minimum density of 40 kg/Cum. (±2 Kgs) including 0.25 mm thick craft paper edging on both edges. The panels shall be fixed to the steel frame structure with minimum 5mm thick craft paper edging on both edges. The panels shall be fixed to the steel frame structure with minimum 5mm thick self- tapping GI screws of required length and nos. with minimum spacing of 300 mm c/c. UUF panel 40 mm thick.
Providing and fixing PUF insulated continuous sandwich panels for roofs total thickness not less than 30 mm made out from continue line method panel shall have pre coated GI sheet on both side of Polyurethane foam with external face being corrugated in shapefor GI and PU foam both material. The crest height of the panel shall be of 35mm minimum with 250mm c/c pitch. The Precoated sheet shall be of minimum 240mpa steel grade confirming to IS 14245:1995 and shall have zinc coating of 120 gsm as per IS:277, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches whiletransportation. The roof panels are laid over a frame work of trusses, columns and purlins fixed using 90 mm self-drilling bolts with rubber washer including all types of flashings. PU Foam must be self-extinguishing. Fire retardant type having minimum density of 40 Kg/ Cum.(±2 Kgs) including 0.25 mm craft paper edging, self-tapping screws of required length and nos. etc. complete as per structural design and direction of Engineer-incharge
Providing and fixing of Bottom and topU track for closing of end joints for cut PUF panels. The U track shall be made out of 1 mm thick pre coated GI sheet. The Precoated sheet shall be of minimum240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per IS:277 : 1992 , 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The U track shall be fixed with suitable POP rivet with wall roof panels and plinth with Expandable fasteners with minimum spacing of 450mm c/c. The Utrack shall be fixed to RCC Plinth or Tie Beams by suitable anchor bolts.
Daylighting Panels: 2mm thick polycarbonate panel size of 1.0m x 3.3m also as per technnical specifications as per design.
Downtake pipes as per standards/design
Insulation : 50mm thick 16 Kg/m3 density fiberglass insulation with GI sub-girt etc., complete as per design.
Steel Ventilators "S" type fixed louvers as per drawings made out of cold rolled elements of 2mm thick as per design.
Providing and fixing Hilti RE-500 Chemical Rebaring as per IS As per IS 456 & ACI 318
HDPE sheet of black colour high density polyurethene sheet) waterproofing 200 micron should be free from wrincles or any damages
Supplying and fixing motorized with key switch (operated electrically) rolling shutters of approved make, made of required size including mechanical device, ball bearing, top cover, with interlocking 18 gauge MS laths with good quality springs and special axles, necessary side guide rails, tees, iron pulleys and bearings etc. with hold down bolts and clamps embedded in 1:2:4 cement concrete and with suitable metal hood and operating handles, gears etc. complete including one shop coat of red oxide primer (only clear opening to be measured).
Providing and fixing door make acoustic door Shutter with frame and hardware as per manufacture specification with overall size as per site requirement. Door frame are made with 1.6mm (16 gauge)galvanised iron steel sheet pressed multi bend to S/L rebate of size 120mmx57mm. Door shutter are made with 1.2 mm thick Galvanized steel sheet pressed formed to provide a 46mm thick fully flush double skin panel shall with lock seam joints at style edges and filled with Honey comb structure with reinforcement at top, bottom and stile surrounds. The items also include provision for required iron monger and Powder Coated finish in RAL colour shades.Includes hardware hinges 4'' X3'' X3 mm - 2 ball bearing,Door Closer with Standard Arm,SS D-type Handle (19x300mm Long),Mortised Dead Lock with Cylinder,Acoustic Seal for Frame,Bottom Seal for Door Shutter,Acoustic seal for Shutter Meeting stile,Fasteners and End caps,double walled vision panel of size 200mm X 300 mm with 6mm toughened Glass -18 Gap filled with Argon gas - and 6mm toughenedglass includes loading/ unloading, Hardware MakeDAUERHAFT / Equivalent, Door size ( double leaf Glass Make-Modi, saint- Gobain , Asahi, Gold plus/Equivalent.),
Supplying and fixing motorized with key switch (operated electrically) rolling shutters , as per approved specification.
Supplying providing and fixing vivration deamping mats STUDFLEX (Christi and grey ) 400x400x25 around and under the concrete of the inertia of the concrete block in the 2 main chambers.
(Carried Over to Summary of Civil Works)
ALL SUB-HEAD
Total of DSR & NDSR
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01, DATED 07.01.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
MODIFICATION OF EXISTING PANEL
SITC 33Kv 1250A Indoor VCB With Accessories
SITC Transformer 2.5 MVA 33/.433VAC with all accessories & OLTC
SITC Bus Bar modification & addition
SITC LT Panel with DG bus coupler 4000A, 2500, exsiting modification & out going
SITC Earthing, fabrication & accessories with related Civil works
Modification of all three transformer for parallel operation
Sub Total
SUBHEAD- I: DISTRIBUTION BOARD
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.Make:BS,Havells,Legrand (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing following rating, four pole, three phase and neutral, 415 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Providing and fixing 125A capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
Total carried over to Summary
SUB-HEAD - II : INTERNAL WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 32 amps modular socket outlet and 32 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
Supplying and fixing of call bell / buzzer suitable for single phase,230 volt complete as required.
TOTAL RS.
SUB-HEAD III - FANS & LIGHT FIXTURES:
Supply Installation, testing & commissioning of LED Recessed Downlighter having cut-out dia of 125mm(± 3mm) & lip to lip dia of 137mm (± 3mm) delivering minimum system lumen output of 1800 lumens & with a minimum system efficacy of 120 lm/W. The luminaire should have a color temperature of 6500°K, CRI≥80 & R9≥0 and SDCM≤5. The LEDs used should be from Philips/Signify/APT Electronics/Osram/Nichia/Cree/Lumileds/Bridgelux. The luminaire should have deep recessed COB light source with UGR≤19 & Shielding Angle of 38°. The luminaire shall have the beam angle of 60° to 65°. The DALI driver shall have THD≤20% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing, heat sink & ring/rim should made of pressure die-cast aluminum. The luminaire should have faceted reflector made of Spun Aluminum. Reflectors made of Polycarbonate shall not be allowed. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP54 (from front). The luminaire driver shall be of the same make/brand/lighting company as that of LED luminaires. The luminaire brand name shall be embossed/engraved on the luminaire/end plate/Rim/Housing & Not put using sticker or screen printing. The luminaire shall be EMI/EMC compliant. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of the luminaires. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as per 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver. Similar to above specs in Signify (Philips/Ecolink)/Endo/Trilux/LT.
Supply Installation, testing & commissioning of LED Recessed Downlighter having cut-out dia of 125mm(± 3mm) & lip to lip dia of 137mm (± 3mm) delivering minimum system lumen output of 1200 lumens & with a minimum system efficacy of 120 lm/W. The luminaire should have a color temperature of 6500°K, CRI≥80 & R9≥0 and SDCM≤5. The LEDs used should be from Philips/Signify/APT Electronics/Osram/Nichia/Cree/Lumileds/Bridgelux. The luminaire should have deep recessed COB light source with UGR≤19 & Shielding Angle of 38°. The luminaire shall have the beam angle of 60° to 65°. The DALI driver shall have THD≤20% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing, heat sink & ring/rim should made of pressure die-cast aluminum. The luminaire should have faceted reflector made of Spun Aluminum. Reflectors made of Polycarbonate shall not be allowed. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP54 (from front). The luminaire driver shall be of the same make/brand/lighting company as that of LED luminaires. The luminaire brand name shall be embossed/engraved on the luminaire/end plate/Rim/Housing & Not put using sticker or screen printing. The luminaire shall be EMI/EMC compliant. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of the luminaires. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as per 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver. Similar to above specs in Signify (Philips/Ecolink)/Regent/Ligman.
Supply Installation, testing & commissioning of Integral LED 4ft batten with buil-in PIR occupancy sensor. The batten shall have housing made of CRCA Only & the front diffuser shall be made of polycarbonate/polystyrene (Diffuser-Non yellowing type). The LED used shall have life of 50000Hrs @ L70B50, CCT of 6500°K, SDCM≤5 & CRI≥80. The LEDs used should be from Philips/Signify/APT Electronics/Osram/Nichia/Cree/Lumileds/Bridgelux. Luminaire shall be designed to deliver minimum system lumen output of 4000 lumens at a system efficacy of ≥130 lumen/watt. The electronic driver used shall have a power factor ≥0.95 (@full load) and THD ≤10% (@full load), suitable for an operating voltage range of 140-270V AC, Current Ripple ≤5% (@full load), Internal surge protection should be minimum 4KV, high-low voltage cut-off, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. The minimum dimensions (±5mm) of the batten shall be 44mm X 51mm X 1221mm. The luminaire brand name shall be embossed/engraved on the luminaire/accessory/Endplate/Rim/Frame/end caps & not put using sticker/screen printing. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as pr 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Similar to above Specs in Signify (Philips/Ecolink), Endo/LT.
Supply Installation, testing & commissioning of Integral LED 2ft batten. The batten shall have housing made of CRCA Only & the front diffuser shall be made of polycarbonate/polystyrene (Diffuser-Non yellowing type). The LED used shall have life of 50000Hrs @ L70B50, CCT of 6500°K, SDCM≤5 & CRI≥80. The LEDs used should be from Philips/Signify/APT Electronics/Osram/Nichia/Cree/Lumileds/Bridgelux. Luminaire shall be designed to deliver minimum system lumen output of 2000lm at a system efficacy of at-least 125 lumen/watt. Power consumption should not be more than 16W (±2W). The electronic driver used shall have a power factor ≥0.95 (@full load) and THD ≤10% (@full load), suitable for an operating voltage range of 140-270V AC, Current Ripple ≤5% (@full load), Internal surge protection should be minimum 4KV, high-low voltage cut-off, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. The minimum dimensions (±5mm) of the batten shall be 44mm X 51mm X 585MM. The luminaire brand name shall be embossed/engraved on the luminaire/accessory/Endplate/Rim/Frame/end caps & not put using sticker/screen printing. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as per 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Similar to above Specs in Signify (Philips/Ecolink), Regent/Endo.
Supply Installation, testing & commissioning of36W LED CEILING LIGHT
Supply, Installation, testing & commissioning of LED Bulkhead Luminaries, made of high-pressure die-cast Aluminium body with polycarbonate diffuser. Luminaries should be with minimum system efficacy of 110Lumen/Watt and minimum system lumen output of 1100lm.LED used shall have life of 50000Hrs @ L70B50, CCT of 6500°K, SDCM≤5 & CRI≥80. The luminaire driver shall comply to following parameters at 220V to 240V: PF≥0.90 (@full load), THD ≤ 10% (@full load) & in-built surge protection of 2.5KV. The input voltage range shall be 140V to 270V. The fixture should comply with the parameters as per IS10322. The luminaire shall have class C serviceability. The luminaire shall be IP66 & IK09 compliant. The luminaire brand name shall be embossed/engraved on the luminaire/accessory/Endplate & not screen printed or put using sticker. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 Standard, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as per 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Similar to above Specs in Signify (Philips/Ecolink), Endo/Trilux.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
SITC of wall Fan
SITC Fresh air fan 250 mm
SITC 100W HIGH BAY LIGHT
LIGHT FIXTURES: to summary sheet
SUB HEAD -IV : RACEWAY AND CABLE TRAY
Metal Partition Raceways : Floors Supply and fixing in position of following size of under floor GI raceways [consists of body & cover] for distributing cabling in screed floor installations. Raceway should be made up of Pre galvanized sheet conforming to IS 277 with thickness of 1.6mm consists of Body and Openable cover with 275 GSM coating. Raceway should be supplied with required accessories such as fixing brackets and coupling plates as required. Raceway should be confirmed with the standard EN 60-670 and EN 50085-2-2, IP 20 & IK08 in recess / on surface including chasing the wall/floor complete as required of following configurations:
200 x 38 mm Raceway
150 x 38 mm Raceway
100 x 38 mm Raceway
Partition Metal Junction Box : Floors Supply and fixing in position height adjustable under floor crossover Junction box for Raceways for direct access to cables at the intersection of Raceways supplied completely with base and cover plate [lid]. Junction box should be made of Pre galvanized sheet consist of body and cover. Height of the junction box should be adjustable from minimum 65mm. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site. It should be confirmed with the standard EN 50085-2-2 including all accessories complete as required of following sizes:
Sizes:
Box : 400 x 400 x 65-90mm [1mm base & 3mm lid]
Cover Plate : 400 x 400mm
Sizes:
Box : 300 x 300 x 65-90mm [1mm base & 3mm lid]
Cover Plate : 300 x 300mm
Sizes:
Box : 225 x 225 x 65-90mm [1mm base & 3mm lid]
Cover Plate : 225 x 225mm
Sizes:
Box : 150 x 150 x 65-90mm [1mm base & 3mm lid]
Cover Plate : 150 x 150mm
Cable Tray
Supplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Supplying and installing following size of perforated pre-painted M.S cable trays bends with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Supplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Supplying and installing following size of perforated pre-painted M.S cable trays Cross members with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Total of Sub-Head - IV
SUB HEAD - V : ELECTRICAL PANEL
MAIN PANEL
EV Panel
Incomer-01
1 No. 4000A FP microprocessor based EDO, ACB with integral protection as per PRMB-1 mentioned in Premable
Metering and Indication for each Incomer
1 set of R,Y,B,On,Off phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port.
Sets of 4000/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
Busbar
4500A TPN Aluminium Bus Bar (Bus section-01) with colour coded PVC Sleeves
Outgoings Bus Section-01
1 No. 800A 4P MDO,ACB,36KA, Microprocessor Based with On/Off/Trip and Multi Function Meter Indicator For Electrical Panel-01
1 No. 2000A 4P MDO,ACB,50KA, Microprocessor Based with On/Off/Trip and Multi Function Meter Indicator For Electrical Panel-02
1 No. 1600A 4P MDO,ACB,50KA, Microprocessor Based with On/Off/Trip and Multi Function Meter Indicator For Electrical Panel-03
2 No. 3200A 4P MDO,ACB,50KA, Microprocessor Based with On/Off/Trip and Multi Function Meter Indicator For Electrical Panel-05
1 No. 500A 4P MDO,ACB,16KA, Microprocessor Based with On/Off/Trip and Multi Function Meter Indicator For HVAC Panel
Spare as per approved Good for construction drawing
Concourse Panel Descrived Above
PANEL-1
INCOMER
1 No. 800amps 4P MCCB(50KA) with Microprocessor Based release (PRMB) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port.
Sets of 800/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
BUS-BAR
1000 A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
4 Nos. 100 Amp TPN MCCB
3 Nos. 63 Amp TPN MCCB
11 Nos. 63 Amp TPN MCB
Spare as per approved Good for construction drawing
panel as described above
PANEL-2
INCOMER
1 No. 2000amps 4P ACB(50KA) EDO, with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port.
Sets of 2000/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
BUS-BAR
2500 A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
2 Nos. 800 Amp FP ACB
5 Nos. 250 Amp TPN MCCB
1 Nos. 63 Amp TPN MCB
Spare as per approved Good for construction drawing
panel as described above
PANEL-3
INCOMER
1 No. 1600amps 4P ACB(50KA) EDO, with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port.
Sets of 1600/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
BUS-BAR
2000 A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
2 Nos. 1000 Amp FP ACB
4 Nos. 200 Amp TPN MCCB
3 Nos. 125 Amp TPN MCB
Spare as per approved Good for construction drawing
panel as described above
PANEL-4 Main Panel for EMC lab
INCOMER
1 No. 2500amps 4P ACB(50KA) EDO, with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port.
Sets of 2500/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
BUS-BAR
3000 A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
3 Nos. 1250 Amp FP ACB
Spare as per approved Good for construction drawing
panel as described above
PANEL-5
INCOMER
1 No. 3200amps 4P ACB(50KA) EDO, with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port.
Sets of 3200/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
BUS-BAR
4000 A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
2 Nos. 630 Amp FP ACB
3 Nos. 400 Amp FP MCCB
3 Nos. 250 Amp FP MCCB
2 Nos. 100 Amp FP MCCB
2 Nos. 80 Amp FP MCCB
3 Nos. 63 Amp FP MCCB
Spare as per approved Good for construction drawing
panel as described above
Total of Sub-Head - V
SUB HEAD - VI : LIGHTNING PROTECTION SYSTEM
Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, copper tube, having single prong at top, with 85mm dia 6 mm thick copper base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing GI tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required. (for horizontal run).
Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required. (For vertical run.)
Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long with 4 Nos. of G.I. bolts, nuts, check nuts and spring washers etc. complete as required.
Providing and laying G.I. tape, 32mm x 6mm thick, from earth electrode directly in ground as required.
Total of Sub-Head - VI
SUB HEAD - VII : SERVER, DATA & NETWORKING
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
TV antenna socket outlet
Supplying and fixing of RJ-11/RJ 45 (Both Twin socket)I/O Telephone outlet with shutters along with suitable base plate,key stone and surface/concealed back boxes of adequate module size, etc comple in all respect.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
1 run of cable
2 run of cable
3 run of cable
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
Total carried over to Summary
SUB HEAD-VIII: CABLE & END TERMINATIONS
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply of MV cable
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.
3 ½ C - 400 sq mm Aluminium
Supply of Copper Armoured Cable
Supply,following sizes of Fire Survival Copper conductor power/multicore control armoured cable.
Total of Sub-Head - IV carried to summary sheet
Ten Loop Panel.
Two Loop Panel.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of smoke detector with builtin LED complete with all connections ect. As required
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of addressable strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
CABLING & WIRING
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
TOTAL FOR FIRE ALARM SYSTEM
SUB HEAD-X: EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01, DATED 07.01.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SUB HEAD -1.0 PIPING, HYDRANT , SPRINKLER AND ACCESSORIES SYSTEM FOR BUILDINGS
Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .
150 mm dia
Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc and fixing the pipe on the wall / ceiling with suitable clamp / support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required .
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying and Fixing Single Headed Internal Hydrant Valve with instantaneous gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS : 5290 ( Type A ) with blank gunmetal material cap and chain as required .
Single Headed Gunmetal
Supplying and Fixing Single Headed External Yard Hydrant Valve with 1 Nos 63 mm dia instantaneous female Gunmetal material Coupling and cast iron wheel ISI marked Conforming to IS : 5290 ( Type A ) with blank stainless steel cap and chain as required .
Single Headed Gunmetal
Supplying Fixing Testing and Commissioning of butterfly valve of PN 1.6 Rating with Bronze Gunmetal Sheet duly ISI marked complete with nuts , bolts , washers , gaskets conforming to IS : 13095 of following sizes as required .
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI] marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
Supplying and Fixing orifice plate made out of 6 mm thick stainless steel ( Grade 304 ) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg / sqcm complete as required .
Providing Installation Testing and Commissioning of Non Return Valve of following sizes conforming to IS : 5312 complete with rubber gasket , GI Bolts , Nuts , washers etc as required .
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Providing Installation Testing and Commissioning of stainless steel y-strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3mm dia holes with stainless steel flange.
80 mm dia
100 mm dia
150mm dia
200 mm dia
250 mm dia
Supplying and Fixing 63 mm dia 15 m Long RRL Hose pipe with 63 mm dia male and female coupling duly bound with GI wire , rivet etc . Conforming to IS : 636 ( Type A ) as Required .
Gunmetal Material
Supplying and Fixing First aid hose reel with MS Construction Spray painted in Post office red conforming to IS : 884 complete with the following as required
20 mm nominal internal dia water hose thermoplastic ( Textile Reinforced ) Type - 2 as per IS : 12585
20 mm nominal internal dia gunmetal globe valve and nozzle
Drum and Brackets for fixing the equipments on wall
Connections from Riser with 25 mm dia stop gunmetal valve and MS Pipe and socket
40 Metre Length
Supplying and Fixing 63 mm dia Gunmetal Material Short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS : 903 suitable for instantaneous connection to interconnect hose pipe coupling as required
Gunmetal Material
Supplying and Fixing of Fire brigade connection of Cast iron body with gunmetal male intantaneous inlet coupling complete with cap and chain as required for suitable dia ms pipe connection conforming to IS : 904 as required
2 Way 100 mm dia MS Pipe
4 Way 150 mm dia MS Pipe
Supplying and Fixing Air Vessel made of 250 mm dia 8 mm thick ms sheet 1200 mm in height with air release valve on top and flanged connection to riser drain arrangement with 25 mm dia gunmetal wheel valve with required accessories pressure gauge and painting with synthetic enamel paint of approved shade as required
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Upright Sprinkler
Horizontal side wall sprinkler
Providing and fixing of pressure switches in MS pipe line including connection extra as required.
Providing and fixing of Flow switches in MS pipe line including connection extra as required.
150mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of foilwing sizes as required:
150mm dia
Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Providing,installation,Testing & commissioning of Adjustable Rosette Plate For 15mm Dia In White Finish UL Listed Or FM Approved Complete As Required .
Providing and fixing of Fire Hose Cabinet size not less than 2.1 x 1.2 x 0.90 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside 'with the letters "FIRE HOSE" including necessary locking arrangement and painting in PO red colour suitable to accommodate, internal hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle and fire man's axe. It shall be fixed inside the FHC Cabinet Complete as required .
Supplying, installation, testing and commissioning of weather proof M.S hose cabinet of size 750 x 600 x 250mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - (for yard hydrant)
Providing and fixing standard firemans axe with heavy rubber handle.
Providing and fixing dial type pressure gauge with isolation cock and copper pipe on main header Dial diameter 100 mm celebration 0-16 / sq. cm.
Providing and fixing Fire Extinguishers (CO2 type powder ) 4.5 Kg Capacity complete with all accessories as per manufacturers specifications.
Providing and fixing Fire Extinguishers (A, B, C type powder ) 4 Kg Capacity complete with all accessories as per manufacturers specifications.
Providing and fixing Fire Extinguishers mechanical foam type type capacity 9 ltr. complete with all accessories as per manufacturers specifications.
Providing and fixing 25 mm dia Inspector Test Valve 25 mm with drain arrangement complete with all accessories as per manufacturers specifications.
Providing and fixing Fire Extinguishers Clean Agent capacity 2 Kg. complete with all accessories as per manufacturers specifications.
Providing and fixing Fire Extinguishers 50ltr. (Water & Foam type) complete with all accessories as per manufacturers specifications.
Providing and fixing Fire Extinguishers consisting of welded M.S. cylindrical body automatic modular CO2 type extinguisher.(Capacity 22.5 Kg.) complete with all accessories as per manufacturers specifications.
TOTAL CARRIED TO SUMMARY SHEET FOR SUB HEAD A
SUB HEAD-2.0 FIRE FIGHTING PUMPS
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
2280 LPM at 88 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
2280 LPM at 88 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump).
Horizontal type, multistage, centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 LPM at 88 m Head
Supplying, installation, testing and commissioning of electric driven Terrace Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : ( Terrace Fire Pump ).
Horizontal type, multistage, centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
900 lpm at 35 m Head
Fabrication, supply, Insallation testing & commissioning of Electricalcontrol panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
Materials
INCOMINGS
OUTGOINGS
Main Fire Pump
Jockey Pump
Diesel Engine Control
System Controller
Designing, Supply, Installation, Testing Each and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.
TOTAL CARRIED TO SUMMARY SHEET FOR SUB HEAD A
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01, DATED 07.01.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SANITARY FIXTURES & FITTINGS
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing and fixing white vitreous china cistern with dual flushing fitting,of flushing capacity 3 litre/6 litre( adjustable to 4 litre/8 litres),including seat cover and cistern fittings,nuts,bolts and gasket etc. complete.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
a) White Vitreous China Wash basin size 630x450 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:
White glazed fire clay kitchen sink of size 600x450x 250 mm
Providing & Fixing of C.P WALL MOUNTED SWIVEL SPOUT KITCHEN SINK MIXER with all accessories as per approved specifications, Material: Brass,Size(mm):180(L) x 185(W) x 225(D),Spout Length(mm):135,Mounted : Wall mounted,Series : Rivera , Origin Made In India
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing CP Brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms
15 mm nominal bore
Providing and fixing toilet paper holder
C.P. brass
Supply & Installation of Twin Coat Hook:Material:18-8 S, type-304, stainless steel,Application:WC Cubicle Area,Warranty:1 year , Origin Made In India
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931.
15mm nominal bore
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
15 mm nominal bore with 45 cm length
Providing & fixing of C.P Towel ring, cost inclusive of CP flange, fasteners, complete as per manufacturer recommendation as per approved specifications , Origin Made In India.
Providing & Fixing of C.P Towel rail with all accessories as per approved specifications, with 600 mm length, SS 304, and making good the walls wherever required. , Origin Made In India
Supply & Installation of S.STEEL SOAP DISPENSER (HEAVY TRAFFFIC) Container : 18-8 S, Type-304, Stainless Steel Material : Non Corrosive Steel, Capacity : 400 ML, Dispense Volume : 2 ML , Origin Made In India
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing 75 mm high, 50 mm deep and 18 mm thick stone slab table rubbed, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
Supply and fixing of water cooler fully stainless steel of 60 litres cooling capacity and 120 litres storage capacity to be operated on single phase supply with ISI mark. Each Cooler shall be provide with 4 Nos pessmatic tap for Drinking purpose.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
40 mm dia
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Supply & Installation of Disabled S.STEEL GRAB RAIL – 600 MM,32MM DIA.Material : 18-8 S, Type-304, Stainless Steel, Application : WC Area, Diameter : 32 mm , Origin Made In India
Supply & Installation of Auto Closing System Bib Cock, Range:Pressmatic Tap,Flow Rate (Litre Per Minute),0.5 Bar:7.21,1.0 Bar:9.91,2.0 Bar:13.93,3.0 Bar:17.00 , Origin Made In India
Providing & Fixing of Soap Dish with all accessories as per approved specifications of material 304 stainless steel with chrome plating and making good the walls wherever required. , Origin Made In India
Providing and Fixing Electric Hot Water Geyser of Stainless Steel Material Grade 316 with Inlet and Outlet Connection with 15 mm dia Angle Valve and Geyser (25 LTR)shall be equipped with inbuilt non return valve and insulation on inner and outer surfaces for prevention of heat losses 2 nos CP round wall flange and CP Brass Screws and Rawl plugs all other required accessories Complete in all respect as per direction of Engineer - in - charge .
Electric Geyser 15 Litre Capacity
Electric Geyser 25 Litre Capacity
Electric Geyser 3 Litre instant capacity
TOTAL CARRIED OVER TO SUMMARY
INTERNAL & EXTERNAL WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
15mm nominal bore
20mm nominal bore
25mm nominal bore
32 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
50mm nominal bore
65mm nominal bore
80mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required
100 mm dia
Providing and fixing motorized valve with sensor of approved quality, to complete the work.
40 mm dia ( Flushing Riser)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
TOTAL CARRIED OVER TO SUMMARY
SOIL, WASTE, VENT PIPES, RAIN WATER PIPES & FITTINGS.
Providing and fixing soil, waste and vent pipes
Supplying, Installation, Testing and Commissioning of uPVC pipes type -B conforming to IS 13592 (1992) for soil, waste and vent pipes including all fittings rubber ring type (plain or with access door) e.g. bends, junctions, cowls, offsets, access pieces, jointing with rubber ring joints with lubricant etc. fixed with clamps to walls with cement concrete 1:2:4 blocks complete in all respects. (For Soil & Waste Pipe)
Providing, laying, Jointing, Testing and commissioning of uPVC pressure pipes of 6Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design (For Soil & Waste Pipe)
Supplying, Installation, Testing and Commissioning of uPVC, P or S trap of self cleansing design with / without vent. arm Setting in cement concrete 1:2:4 mix complete including cost of cutting & making good the Wall / Floors wherever required.
110 x110 mm outlet
Providing and fixing floor drain with jali size 110X50 size inlet and outlet including cutting and making good the walls and floors wherever required complete in all respects.
110 x 50 mm outlet
Providing and fixing 125 mm dia, 3 mm thick Stainless steel grating with frame for floor traps or drains of required pattern including cutting and making good the floors complete.
125mm dia.
Providing and fixing cast brass Cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect.
100mm dia.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.450 X 450mm -
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
75 mm diameter
110 mm diameter
160 mm diameter
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01, DATED 07.01.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type Compressor(s),microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability and complete as per CPWD specification, connections, inter connections etc. as required.
For Cooling or Heating Both
High Static Ductable Units (Minimum 49 to 77 Pascal External Static Pressure)
Supply, Installation, Testing and commissioning of factory built floor mounted/ceiling suspended DX Type double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding Equipments, complete with Plug fans with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 4/6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply with suitable variable frequency drive control panel, drain connections.
Supplying, installation, testing and commissioning of AMCA Certified (For Air and Sound Performance) ceiling hung / floor mounted vane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency IE3 insulation for Fresh Air and Pressurization Fans and class 'H' insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications. Motor of exhaust fans shall be of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Fan shall be EN 12101-3 Certified & CE/UL Listed for high temprature. Motor make shall be same as mentioned on the fire certificate. Fan total efficiency should not be less than 70%. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Entire fan model & AMCA Seal shall appear in technical submittal of fan. Complete as required as per site conditions.
Static Pressure : 40 mm wg
Insulation : Class H
Sub Head-'A'- HVAC EQUIPMENTS
Sub Head-'B'- Communication cable,Refrigerant & drain Piping,
Total of Sub Head 'B'- Piping
DUCTING, GRILLS, DIFFUSER AND INSULATION
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supplying, Fixing, testing and commissioning of fire dampers of minimum 90 minutes fire rated in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required..
Fire Dampers.
actuator
Note: Raw power shall be tapped off from the respective starter panels by the HVAC vendor for Fire Dampers.
Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
19 mm thick
25 mm thick
Supplying and fixing Installation, Testing and commissioning of 50mm thick aluminium foil faced resin bonded fibre glass insulation (on duct) of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/cu m after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape & covering with 0.63mmx19mm GI wire mesh netting & butting all joints and laced with GI wire complete and finally covered with one layer of tar felt stuck with hot bitumen as per specifications and as required. (for outdoor applications)
Supplying and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Total of Sub Head-'C'- Air Distribution
Sub Head 'D' - HVAC ELECTRICAL PANELS/CABLES & ACCESSORIES
General Notes & Specifications as given below shall be applicable to all panels.The vendors shall consider the following details in their item rates, wherever required:
Supporting rigid steel framework.
Cubicle type, 14 gauge CRCA sheet steel enclosure.
Panel Complete with interconnections and distribution bus bars.
Proper bonding to earth.
Painting/lettering on Breakers and distribution boards, the location they serve, Providing on each panel its circuit diagram.
Providing cable clamps / supports within distribution boards cable alley.
TPN MCCBs shall mean 3 pole MCCBs with adequate size of neutral link.
All MCBs shall be of minimum 10 KA breaking capacity.
All motor feeders MCCBs shall be of motor duty and shall be able to carry the inrush current of motor.
Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.
Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.
IP 42 for indoor panels.
IP 55 for outdoor panels with double door enclosure.
All MCCB’s shall be provided with operating mechanism for door interlock.
Current density of aluminium shall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for rated current of bus bars.
Tinned copper earth bus shall be provided through out the length of each board.
All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS.
All indicating lamps shall be LED type.
All current/voltage transformers shall be cast resin type.
All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.
All panels shall have provision of the following:
Pad locking of Switch board doors.
Pad locking of MCCB’s handles in “OFF” Position.
All PTs / control transformers shall be provided with centre tap earth secondary.
All DOL & Star-Delta Starters shall be provided with voltage based SPPR (single phase preventor relay) and 2 nos. of Aux.Contacts for Remote operation/monitor.
The Panel fabricator shall provide Aluminium Bus-bars link from Breakers wherever more than two nos. of cables are terminated in the breakers.
Readymade 16SWG Sheet steel Enclosure with cutout For MCBs
The breaking capacity of MCCB’s shall be mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise.
All internal control wiring shall be heat resistant type.
Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry shall be from top/bottom as required.
Live parts shall not be accessible after opening the door, Transparent acrylic sheet to be provided to cover the same.
Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto terminal block.
Protection Releases Microprocessor based (PRMB) & Thermal magnetic (PRTM) shall be as describe below:
Over-current/long time protection range 105% - 120 % with Time setting
short circuit /short time protection range 100% - 1000 % with Time setting
Instantaneous short circuit Protection range 200% - 1500 % with Time setting
Earth Fault Protection range 20% - 100 % with Time setting
Under voltage & over voltage protection
Reverse power
Current unbalance
Phase sequence
Measurements
Voltage
Current
Power (Active,Reactive & Apparent)
Energy ((Active,Reactive & Apparent)
Power factor
Frequency
Over-current/long time protection range 105% - 120 % with Time setting
short circuit /short time protection range 100% - 1000 % with Time setting
Instantaneous short circuit Protection range 200% - 1500 % with Time setting
Earth Fault Protection range 20% - 100 % with Time setting
Measurements
Current
Over-current/long time protection range 105% - 120 % with Time setting
Instantaneous short circuit Protection range 200% - 1500 % with Time setting
Over-current
Short circuit
Preambles to BOQ for Cables and Cable Trays
The contractor shall consider the following details in their item rates, wherever required:
The rate shall also include the following :
Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 65 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 35 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below.Complete as required as per site conditions.
EACH Motor control Centre(MCC)/Panel shall include cost of cabling, wiring, control wiring & inter locking in order to execute the required sequence of operation.
A separate Each of CTs to be provided for wiring from CT’s and voltage transducers to be brought on to separate Each of terminals.
Note : ACB shall be motor duty and suitable for 35 KA (ICS) fault current
Motor Control Centre (415 V) consisting of
1 No. 200 amps 4 Pole ACB ICU=ICS=35KA having front operating handle with door interlock and as per preamble above complete with the following :
Busbar
TPN bus bars shall be of aluminium and shall be sleeved. Phase bus bars shall be rated at 250 amps and neutral bus bar shall be of 50% capacity suitable to withstand symmetrical fault level of 25KA of 415 V.
Maximum density of aluminium bus bars for current carrying capacity shall be one amp per square mm.
Outgoing
Supplying,Receiving, fixing, testing & commissioning of HVAC Panel for VRV-1 as described above.Complete as required as per site conditions.
Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels,suitable for outdoor applications, including anchoring into the wall, wiring terminating into MCCB and copper earthing, in each panel shall be provided by the electrical contractor.
All wiring and copper earthing of motors from the panel shall be included.
The panel shall include the following components & accessories.
The number of control panels shall be as follows.
1 No.63A TP MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle.
1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT's
1Set of indicating LED lamps for MCCB On/Off with protective SP MCB's.
1 Set of CTs of the ratio 40/5A with class 0.5 Accuracy for Metering, burden 15 VA
120A TPN Aluminium Bar with colour coded PVC Sleeves
2 Nos. 63A TP MCCB with---HP SD starter with VFD bypass with contactor
2 Nos. 32A TP MCB (including 1 no spare) with ---HP DOL starter with VFD bypass with contactor
2 Nos. 10A DP MCB
3 Nos. 16A SPN MCB c curve 10 KA
Note- Necessary wiring and interlocking for the above equipments shall be done with the Fire Alarm system such that required fan gets actuated and shut off the AHU in case of fire as per fire zones. No/NC contacts & supply arrangements shall also be spared for the fire damper actuation & control.
Supplying,Receiving, fixing, testing & commissioning of AHU Panel as described above
MV Cable
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Total of Sub-Head-'D'-"Electrical (In HVAC Scope)"
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Total of sub head
Sub Head-'E'- Split AC
2.0 TR with 5 Star BEE Rating
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01, DATED 07.01.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Supply, Installation, testing & commissioning of air cooled, non lubricated, single stage or multistage screw air compressor capable of delivering the required quantity of compressed air at 10.0 Bar working pressure. The compressor unit shall be comprising of suction air filter, discharge check valve, compressor, air receiver, integrated refrigerated air dryer, receiver tank, pressure valve, terminal check valve, after cooler, oil cooler, oil filter, oil stop valve, motor, annunciation panel, motor, control panel, pre-requisite safeties and other accessories as required for the proper functioning of compressor unit. The complete compressor unit shall be skid mounted, enclosed in an accoustic enclosure and directly coupled with the motor. (vendor to specify whether it is single stage or multistage and also model number). Air Quality Standards ISO 8573.1 & ISO12500 Class 2. (dew point -40 deg C)
Providing & fixing on main line CI/CS fabricated Moisture Separator baffle type of suitable diameter for opearting pressure of 16 Bar, flanged ends suitable for compressed air to remove entrained water particles from air so that they can be drained away by drain trap. Complete with flanges, nuts, bolts, gaskets, washers etc.
Providing, fixing, jointing and testing in position the following heavy class (Class C) GI pipes conforming to IS:1239 cut to required lengths including all necessary fittings (All fittings shall confirm to IS:1879- part 1 to 10) and specials such as bends, tees, unions, reducers, flanges & plugs etc. Fixing at wall/ceiling level supported by galvanized clamps, hangers etc, as per specification or chasing in wall/floor and making good the same by using 1:1 cement mortar over the wire mesh. Threading, jointing and making proper connections. Cutting hole in wall/floor/ slab and making good the same.
Providing and fixing approved make brass ball valve confirming to IS 776 with suitable transition pipe fittigs, union etc complete
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01, DATED 07.01.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SITC of Overhead / Rail Gantry Crane including supply of complete structure, rails, hoist, trolley, electrical system, cabling, control panel, remote pendant, testing & commissioning as per approved specifications
Supplying, installation, testing & commissioning of 8 Passenger , Gearless type,Machne room-less passenger lift having contract speed of 1.5 MPS serving different floors in the lift shaft as per detailed specifications as under and additional details given in schedule of technical particulars. Provisions of General CPWD specifications for lift works are to be followed.
Design of lifts:- Passengers Type
Capacity:-8Passengers
Speed - 1.5 Metre/Sec. (MPS)
Door Operation - Full Height Infra-red cross-multi beam
Floor - G+1 = 2stops
Travel - 12Mtr. (Approx.)
Stop & Opening - 2 Stops &2 Openings (One side only)
Type and Position of Machinery - Gearless type, Machine Room-less
Controller - Microprocesser based AC variable voltage & variable frequency Control
Lift Car inside size - 1800mm x1800mm ( Width x Depth).
Size of Lift Well - 2200mm x 2200mm (Width x Depth)
Entrance -1050mm
Pit Depth -1500mm
Automatic rescue device complete with dry maintenace free batteries as required.
Power - 415 V ±10%, 3 Phase, 50 Hz.
Type or Design of Lift Car - Stainless steel scratch proof (Moon Rock Finish).
Car door - Power operated centre opening horizontal sliding stainless steel Scratch proof (Moon Rock Finish).
Door Safety - Full Height Infra-red cross-multi beam
Landing doors - Centre opening, stainless steel scratch proof (Moon Rock Finish) at all floors. It must be fire-rated for minimum 1-Hrs and supplier must provide the certiifcate for the same alongwith material supply.
Car operating Panel / Landing operating panel - Car operating panel with braile symbol luminous buttons and braile illuminated push buttons on all landing in Stainless Steel Mirror finish.
Hand rail - Shall be SS finished not less than 600mm long, fixed above 900mm from the car-floor level on rear-wall or side wall.
Voice announcement system - In car to announce the position of the elevetor in hoist way as the car passes or stop at a floor served by the elevator.
Intercom system
Complete as Described above
Intercom system
Total carried over to Summary
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01, DATED 07.01.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
Excavating trenches by mechanical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Carriage of Excavated earth by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KM complete.
Supplying and filling in plinth with sand under floors including, watering, ramming consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil.
Supplying chemical emulsion in sealed containers including delivery as specified
Anti termite treatment
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
TOTAL (Carried Over to Summary of Civil Works)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
Centering and shuttering including strutting, propping etc. and removal of form work for :
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
TOTAL (Carried Over to Summary of Civil Works)
Centering and shuttering including strutting, propping etc. and removal of form for :
Under 20 cm wide
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
Add for using extra cement in the items of design mix over and above the specified cement content therein.
TOTAL (Carried Over to Summary of Civil Works)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in :
TOTAL (Carried Over to Summary of Civil Works)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium handles of approved make anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessry screws etc. complete.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
TOTAL (Carried Over to Summary of Civil Works)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
TOTAL (Carried Over to Summary of Civil Works)
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Extra for pre finished nosing to treads of steps of marble / granite stone.
Extra for marble / granite stone flooring in treads of steps and risers using single length up to 2.00 metre.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Providing and use of Floor Hardener (FOSROC) as per site requirement / client instructions
Providing and Laying 3 mm thick epoxy screeding consisting of araldite GY 257, 100 parts by weight hardener HY 830,40 parts by weight hardener,HY850,20 parts by weight plus quartz sand 900 parts over a primed surface with primer araldite GY 257,100 parts by weight and hardener HY840,50 parts by weight including application of two coats based on araldite GY257,100 parts hardener HY830,40 parts hardener HY 850,20 parts and flow control agents 1 to 3% with acrosil DTO 75, 3 parts complete as per Ciba Geigy specification including pereparation of surface to recived the treatment and top layer finished polimer based epoxy to withstand the indestrial load and weare and teare complete as per the direction of engineer in charge.
TOTAL (Carried Over to Summary of Civil Works)
Providing and fixing false ceiling with 10mm thick fire proof acrylic aluminium laminated gypsum with fibre tiles 600x600mm (tegular/equivalent) with suitable aluminium works and grids powder coated to matching colour including adjustable hangers ceiling cleats hold fastner etc., complete as per manufactures specification & recommendations and drawings all aluminium grid works and necessary fixtures for hoisting with work and necessary openings etc., complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Downtake pipes as per standards/design
Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800-1984 and IS:801-1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ ArchitekV2.5.16/ Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability.
The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm.
The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects.
Providing and fixing PUF insulated continuous sandwich panels for wall of total thickness not less than 50 mm or 40mm (as specified) and width 1.0m, made out from continue line method on automatic plant. Panel shall have precoated GI sheet on both side of Polyurethane foam confirming to IS12436:1988. The precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per IS:277, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The panels shall be vertically joined together by tongue and groove joints. The PU foam shall be self- extinguishing, fire retardant type having minimum density of 40 kg/Cum. (±2 Kgs) including 0.25 mm thick craft paper edging on both edges. The panels shall be fixed to the steel frame structure with minimum 5mm thick craft paper edging on both edges. The panels shall be fixed to the steel frame structure with minimum 5mm thick self- tapping GI screws of required length and nos. with minimum spacing of 300 mm c/c. UUF panel 40 mm thick.
Providing and fixing PUF insulated continuous sandwich panels for roofs total thickness not less than 30 mm made out from continue line method panel shall have pre coated GI sheet on both side of Polyurethane foam with external face being corrugated in shapefor GI and PU foam both material. The crest height of the panel shall be of 35mm minimum with 250mm c/c pitch. The Precoated sheet shall be of minimum 240mpa steel grade confirming to IS 14245:1995 and shall have zinc coating of 120 gsm as per IS:277, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches whiletransportation. The roof panels are laid over a frame work of trusses, columns and purlins fixed using 90 mm self-drilling bolts with rubber washer including all types of flashings. PU Foam must be selfextinguishing. Fire retardant type having minimum density of 40 Kg/ Cum.(±2 Kgs) including 0.25 mm craft paper edging, self-tapping screws of required length and nos. etc. complete as per structural design and direction of Engineer-incharge
Providing and fixing of Bottom and topU track for closing of end joints for cut PUF panels. The U track shall be made out of 1 mm thick pre coated GI sheet. The Precoated sheet shall be of minimum240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per IS:277: 1992 , 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The U track shall be fixed with suitable POP rivet with wall roof panels and plinth with Expandable fasteners with minimum spacing of 450mm c/c. The Utrack shall be fixed to
Daylighting Panels 2mm thick polycarbonate panel size of 1.0m x 3.3m also as per technnical specifications as per design
Hardware: high tensile fastener conforming to relevant IS codes & ASTM standards etc. complete as per design.
Providing and laying non-expansive cement based grouting material (SIKA 214SP or equivalent)including centering and shuttering etc.complete as par manufractures specification and direction of Engineer-in-charge.
TOTAL (Carried Over to Summary of Civil Works)
12 mm cement plaster of mix :
15 mm cement plaster on rough side of single or half brick wall of mix :
6 mm cement plaster of mix :
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
Applying priming coat :
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
TOTAL (Carried Over to Summary of Civil Works)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge.
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.
TOTAL (Carried Over to Summary of Civil Works)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed echanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Glazing and paneling to be paid for separately) :
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Filling the gap in between aluminium frame and adjacent RCC/Brickwork/ Stone Work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge
TOTAL (Carried Over to Summary of Civil Works)
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :
(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :
TOTAL (Carried Over to Summary of Civil Works)
Providing and fixing door make acoustic door Shutter with frame and hardware as per manufacture specification with overall size as per site requirement. Door frame are made with 1.6mm (16 gauge)galvanised iron steel sheet pressed multi bend to S/L rebate of size 120mmx57mm. Door shutter are made with 1.2 mm thick Galvanized steel sheet pressed formed to provide a 46mm thick fully flush double skin panel shall with lock seam joints at style edges and filled with Honey comb structure with reinforcement at top, bottom and stile surrounds. The items also include provision for required iron monger and Powder Coated finish in RAL colour shades.Includes hardware hinges 4'' X3'' X3 mm - 2 ball bearing,Door Closer with Standard Arm,SS D-type Handle (19x300mm Long),Mortised Dead Lock with Cylinder,Acoustic Seal for Frame,Bottom Seal for Door Shutter,Acoustic seal for Shutter Meeting stile,Fasteners and End caps,double walled vision panel of size 200mm X 300 mm with 6mm toughened Glass -18 Gap filled with Argon gas - and 6mm toughenedglass includes loading/ unloading, Hardware MakeDAUERHAFT / Equivalent, Door size ( double leaf Glass Make-Modi, saint- Gobain , Asahi, Gold plus/Equivalent.),
Providing and fixing Acoustic metal glass window with frames of size 120x57x1.6mm manufactured from galvanised iron steel sheet of 16 gauge including hold-fasts, jambs, beads, angle threshold, pressed galvanised iron steel welded and fixed together by mechanical means, adjustable lugs, nominal size in the hollow portion of the steel frames and having offsets as required (One side or both sides),with 6mm Glass -18 Gap filled with Argon gas - and 6mm glass toughened insulated glass for windows, Make-DAUERHAFT / Equivalent, , Glass Make- Modi, saint- Gobain , Asahi, Gold plus/Equivalent.)Hardware make: DAUERHAFT / Equivalent and applying a powder coat of approved RAL colour complete including fixing in position at all heights, includes loading/ unloading.
Supply and installation of Acoustic lining (clip in tile)in test cell as per given specification. (Item Includes 100mm thick acoustic, 600x600mm easily dismantle & re-erect type acoustic panes for wall and roof. Acoustic treatment shall consist of 0.8mm thick clip in the filled with rockwool of 64kg/cum density laminated with tissue paper confirming IS 8183 and sound damping sheet.Price includes all accessories like tiles,fitting profile, hole & tie clamp, ms angle, rockwool, MS sheet,L&Z flashing, unistrut and painting.
Providing and fixing Hilti RE-500 Chemical Rebaring as per IS As per IS 456 & ACI 318
HDPE sheet of black colour high density polyurethene sheet) waterproofing 200 micron should be free from wrincles or any damages
Supplying and fixing in position the Acoustic rolling shutters of approved manufacturer having 18 gauge sheet lanths including pressed steel bottom rails, channel guides, ball bearings, suspension shaft, bolts, screws, brackets, hood, locking arrangement and grills for ventilation including all fittings and accessories as per drawings and specifications including one shop coat of red oxide zinc chromate primer, crafting, packing, transporting to site all freight and insurance charges, assembling fitting and fixing at all elevations and a coat of red oxide zinc chromate primer and synthetic enamel paint as per note no. 2 above etc., complete as per drawing and specifications and as directed by Engineer-in-charge. Motor Operated Rolling Shutter
Providing and fixing High Acoustical False Ceiling system, having NRC (Noice Reduction Coefficient) 0.90 minimum using integral densified edged eco friendly, fully perforated, Non-Cementitious light weight calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm / 595x1190 mm & should be 15mm at all around the edge resting portion and 10mm thick at the quadrant, the tile should have fibre glass fleece on rear side along with backing of stone wool insulation of density 50 kg/m3 and 50mm thickness. The stone wool must be certified by EUCEB as Non-carcinogenic and Bio-Soluble. NRC with 50mm thick stone wool shall be 0.90 tested to BS EN ISO 354:2003. The tile should have Light reflectance > 85%, Non combustible as per BS:476 (part-4), surface spread of flame of classification class-l as per BS:476 Part-7), Smoke free as per NBC 2016 & as per ASTM E 84 Certification, Smoke Developed Index (SDI) Class – 1 or Class -A, Humidity resistance of 100% RH, thermal conductivity k = 0.048 W/m°K to 0.052 W/m°K as per ECBC Code 2024, to be laid in true horizontal level suspended on inter locking PPGI T-Grid of hot dipped galvanised iron section of minimum 0.40 mm thick on Slimline profile, rotary stiched double webbed white with 3mm rounded reveal (white/black) on the 15mm wide exposed surface suspended from the soffit with appropriate hanger, comprising of main-T runners of size 15x38mm of length 3600 mm, primary cross - T of size 15x38 mm of length 1200 mm and secondary intermediate cross T of size 15x38 mm of length 600mm to form grid module of size 600 x 600 mm / 600x1200mm, Main Tee's & Cross Tee's to have mitered ends with "bird's mouth" notches to form mitered uniform junction, suspended from ceiling using galvanised mild steel items (galvanized @ 80 grams per sqm) dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25xx25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if required. The entire grid rests on periphery of galvanised pre coated iron perimeter wall angle of size 22x18x0.40 mm of length 3000 mm to be fixed on periphery wall / partition wall or any other support with the help of plastic rawl plugs at 450 mm center to center and 35 mm long dry wall S.S screws. The work shall be carried out as per drawing and as per directions of the Engineer-in-Charge.
Providing erection, and commissioning of Pre-Engineered Building systems with the following Design including validation of design through IITs (any), Manufacture, supply and erection of Factory made builtup Structural steel work using HR plates of minimum 6mm thick , beams, angles, channels, M.S. rods, confirming to IS 226, 2062 grade A/B (weldable) sections with approved welding with electrodes confirm to IS: 814, including cutting, hoisting, fixing in position and applying a coat of epoxy primer (surface preparation with nuts and bolts and washers confirming to IS: 1364 & IS: 1367 clause 4.6 in sections, columns, beams, rafters, bracings, cladding, crane girders, rod sections, steel ladders, suspended platform, insert plates and base plates, stair- case etc. complete as per the fabrication and errection tolerence. All primary and secondary members (dynamic loading) nuts bolts and washers shall be confirmed as per IS standards. The contractor should submit shop fabrication and erection drawings along with the sequency of work and methodology of construction for approval before commencement of work. All other accessories and systems required for total habitutal building shall be included in the building/rates quoted (for all other details refer detail TCC & Annexure and also to be read with in conjunction with Technical specifications) Rates quotes for entire PEB dust free system includes scaffolding, all types for taxes, safety etc.,
Built up sections with 250 mpa/345 mpa plates of varying thickness with minimum plate thickness of 6mm: Providing, fabricating, transportationand errection as per specifications and fabrication drawings, members for all types of structure and for all heights & at all levels including provision of necessary erection high tensile fasteners, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary operations such as but not limited to preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding etc. complete. All main component like column, rafters, crane beams manufactured on automated machines as per standards cutting, grinding, using CNC machines etc., complete specifications read in conjunction with technical specifications required to complete dust free building systemsas per design.
TOTAL (Carried Over to Summary of Civil Works)
ALL SUB-HEAD
Total of DSR & NDSR
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
Percentage BoQ At Par
BoQ_Ver4.0
Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51280 / NATRAX / INDORE / NIT / CW / 01, DATED 07.01.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender.Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SUBHEAD- I: DISTRIBUTION BOARD
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.Make:BS,Havells,Legrand (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing following rating, four pole, three phase and neutral, 415 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Providing and fixing 125A capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
Total carried over to Summary
SUB-HEAD - II : INTERNAL WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 32 amps modular socket outlet and 32 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
Supplying and fixing of call bell / buzzer suitable for single phase,230 volt complete as required.
TOTAL RS.
SUB-HEAD III - FANS & LIGHT FIXTURES:
Supply Installation, testing & commissioning of LED Recessed Downlighter having cut-out dia of 125mm(± 3mm) & lip to lip dia of 137mm (± 3mm) delivering minimum system lumen output of 1800 lumens & with a minimum system efficacy of 120 lm/W. The luminaire should have a color temperature of 6500°K, CRI≥80 & R9≥0 and SDCM≤5. The LEDs used should be from Philips/Signify/APT Electronics/Osram/Nichia/Cree/Lumileds/Bridgelux. The luminaire should have deep recessed COB light source with UGR≤19 & Shielding Angle of 38°. The luminaire shall have the beam angle of 60° to 65°. The DALI driver shall have THD≤20% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing, heat sink & ring/rim should made of pressure die-cast aluminum. The luminaire should have faceted reflector made of Spun Aluminum. Reflectors made of Polycarbonate shall not be allowed. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP54 (from front). The luminaire driver shall be of the same make/brand/lighting company as that of LED luminaires. The luminaire brand name shall be embossed/engraved on the luminaire/end plate/Rim/Housing & Not put using sticker or screen printing. The luminaire shall be EMI/EMC compliant. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of the luminaires. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as per 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver. Similar to above specs in Signify (Philips/Ecolink)/Endo/Trilux/LT.
Supply Installation, testing & commissioning of LED Recessed Downlighter having cut-out dia of 125mm(± 3mm) & lip to lip dia of 137mm (± 3mm) delivering minimum system lumen output of 1500 lumens & with a minimum system efficacy of 120 lm/W. The luminaire should have a color temperature of 6500°K, CRI≥80 & R9≥0 and SDCM≤5. The LEDs used should be from Philips/Signify/APT Electronics/Osram/Nichia/Cree/Lumileds/Bridgelux. The luminaire should have deep recessed COB light source with UGR≤19 & Shielding Angle of 38°. The luminaire shall have the beam angle of 60° to 65°. The DALI driver shall have THD≤20% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing, heat sink & ring/rim should made of pressure die-cast aluminum. The luminaire should have faceted reflector made of Spun Aluminum. Reflectors made of Polycarbonate shall not be allowed. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP54 (from front). The luminaire driver shall be of the same make/brand/lighting company as that of LED luminaires. The luminaire brand name shall be embossed/engraved on the luminaire/end plate/Rim/Housing & Not put using sticker or screen printing. The luminaire shall be EMI/EMC compliant. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of the luminaires. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as per 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver. Similar to above specs in Signify (Philips/Ecolink)/Regent/Ligman.
Supply Installation, testing & commissioning of Integral LED 4ft batten with buil-in PIR occupancy sensor. The batten shall have housing made of CRCA Only & the front diffuser shall be made of polycarbonate/polystyrene (Diffuser-Non yellowing type). The LED used shall have life of 50000Hrs @ L70B50, CCT of 6500°K, SDCM≤5 & CRI≥80. The LEDs used should be from Philips/Signify/APT Electronics/Osram/Nichia/Cree/Lumileds/Bridgelux. Luminaire shall be designed to deliver minimum system lumen output of 3900lm at a system efficacy of ≥130 lumen/watt. The electronic driver used shall have a power factor ≥0.95 (@full load) and THD ≤10% (@full load), suitable for an operating voltage range of 140-270V AC, Current Ripple ≤5% (@full load), Internal surge protection should be minimum 4KV, high-low voltage cut-off, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. The minimum dimensions (±5mm) of the batten shall be 44mm X 51mm X 1221mm. The luminaire brand name shall be embossed/engraved on the luminaire/accessory/Endplate/Rim/Frame/end caps & not put using sticker/screen printing. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as pr 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Similar to above Specs in Signify (Philips/Ecolink), Endo/LT.
Supply Installation, testing & commissioning of Integral LED 2ft batten. The batten shall have housing made of CRCA Only & the front diffuser shall be made of polycarbonate/polystyrene (Diffuser-Non yellowing type). The LED used shall have life of 50000Hrs @ L70B50, CCT of 6500°K, SDCM≤5 & CRI≥80. The LEDs used should be from Philips/Signify/APT Electronics/Osram/Nichia/Cree/Lumileds/Bridgelux. Luminaire shall be designed to deliver minimum system lumen output of 2000lm at a system efficacy of at-least 125 lumen/watt. Power consumption should not be more than 16W (±2W). The electronic driver used shall have a power factor ≥0.95 (@full load) and THD ≤10% (@full load), suitable for an operating voltage range of 140-270V AC, Current Ripple ≤5% (@full load), Internal surge protection should be minimum 4KV, high-low voltage cut-off, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. The minimum dimensions (±5mm) of the batten shall be 44mm X 51mm X 585MM. The luminaire brand name shall be embossed/engraved on the luminaire/accessory/Endplate/Rim/Frame/end caps & not put using sticker/screen printing. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as per 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Similar to above Specs in Signify (Philips/Ecolink), Regent/Endo.
Supply Installation, testing & commissioning of Recess LED Luminaire made of CRCA & sealed optical modules in shape of a pyramid or inverted cup made of Injection molded polycarbonate/plastic/polystyrene/ABS Plastic. The luminaire shall employ deep recessed diffused optical compartments with individual diffuser for each optical module. The luminaire shall comply to UGR≤16. The luminaire shall have IK rating of IK-02. The luminaire should not have single flat diffuser for whole luminaire. The luminaire shall have System efficacy of ≥130lumens/watt. The luminaire shall deliver system lumen output of 4000 lumens. The LEDs used shall have CCT of 6500°K having CRI≥80, & SDCM≤5 & life class of 50000hrs @ L70B50. The LEDs used should be from Philips/Signify/APT Electronics / Osram / Nichia / Cree / Lumileds / Bridgelux. The luminaire shall use DALI driver having factor ≥0.95 (@full load) and THD ≤20% (@full load), current ripple ≤5% (@full load) suitable for an operating voltage range of 140-270V AC, Internal surge protection should be minimum 2.5KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. The luminaire brand name shall be embossed/engraved/screen printed on the luminaire/accessory/Endplate/Rim/Frame. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. The luminaire dimension shall be 595MM X 595MM with minimum luminaire height as 70MM. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The luminaire dimensions shall be 595mm X 595 mm X 70mm. The successful bidder must submit the NABL accreditation certificate along with scope of NABL accreditation for Luminaire manufacturer before supply of material. The driver shall be of the same make/brand/lighting company as that of LED luminaire. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Similar to above Specs in Signify (Philips/Ecolink), Endo/Igguzini.
Supply, Installation, testing & commissioning of LED Bulkhead Luminaries, made of high-pressure die-cast Aluminium body with polycarbonate diffuser. Luminaries should be with minimum system efficacy of 110Lumen/Watt and minimum system lumen output of 1100lm.LED used shall have life of 50000Hrs @ L70B50, CCT of 6500°K, SDCM≤5 & CRI≥80. The luminaire driver shall comply to following parameters at 220V to 240V: PF≥0.90 (@full load), THD ≤ 10% (@full load) & in-built surge protection of 2.5KV. The input voltage range shall be 140V to 270V. The fixture should comply with the parameters as per IS10322. The luminaire shall have class C serviceability. The luminaire shall be IP66 & IK09 compliant. The luminaire brand name shall be embossed/engraved on the luminaire/accessory/Endplate & not screen printed or put using sticker. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 Standard, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 as per 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Similar to above Specs in Signify (Philips/Ecolink), Endo/Trilux.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
SITC Fresh air fan 250 mm
LIGHT FIXTURES: to summary sheet
SUB HEAD -V : RACEWAY AND CABLE TRAY
Metal Partition Raceways : Floors Supply and fixing in position of following size of under floor GI raceways [consists of body & cover] for distributing cabling in screed floor installations. Raceway should be made up of Pre galvanized sheet conforming to IS 277 with thickness of 1.6mm consists of Body and Openable cover with 275 GSM coating. Raceway should be supplied with required accessories such as fixing brackets and coupling plates as required. Raceway should be confirmed with the standard EN 60-670 and EN 50085-2-2, IP 20 & IK08 in recess / on surface including chasing the wall/floor complete as required of following configurations:
200 x 38 mm Raceway
150 x 38 mm Raceway
100 x 38 mm Raceway
Partition Metal Junction Box : Floors Supply and fixing in position height adjustable under floor crossover Junction box for Raceways for direct access to cables at the intersection of Raceways supplied completely with base and cover plate [lid]. Junction box should be made of Pre galvanized sheet consist of body and cover. Height of the junction box should be adjustable from minimum 65mm. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site. It should be confirmed with the standard EN 50085-2-2 including all accessories complete as required of following sizes:
Sizes:
Box : 400 x 400 x 65-90mm [1mm base & 3mm lid]
Cover Plate : 400 x 400mm
Sizes:
Box : 300 x 300 x 65-90mm [1mm base & 3mm lid]
Cover Plate : 300 x 300mm
Sizes:
Box : 225 x 225 x 65-90mm [1mm base & 3mm lid]
Cover Plate : 225 x 225mm
Sizes:
Box : 150 x 150 x 65-90mm [1mm base & 3mm lid]
Cover Plate : 150 x 150mm
Cable Tray
Supplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Supplying and installing following size of perforated pre-painted M.S cable trays bends with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Supplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Supplying and installing following size of perforated pre-painted M.S cable trays Cross members with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.
Total of Sub-Head - V
SUB HEAD - VI : ELECTRICAL PANEL
MAIN PANEL
INCOMER
1 No. 1250amps 4P MCCB(35KA) with Microprocessor Based release (PRMB) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port.
Sets of 1250/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
BUS-BAR
1250 A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
1 Nos. 600 Amp TPN MCCB
1 Nos. 400 Amp TPN MCCB
1 Nos. 250 Amp TPN MCCB
2Nos. 100 Amp TPN MCCB
Spare feeder as per approved GFC Drawing
panel as described above
Ten Loop Panel.
Two Loop Panel.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of smoke detector with builtin LED complete with all connections ect. As required
CABLING & WIRING
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
TOTAL FOR FIRE ALARM SYSTEM
SUB HEAD-VIII: CABLE & END TERMINATIONS
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply of MV cable
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.
3 ½ C - 400 sq mm Aluminium
Supply of Copper Armoured Cable
Supply,following sizes of Fire Survival Copper conductor power/multicore control armoured cable.
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.78 MB
NATRAX_Drawings.rar
Additional Documents • 12.14 MB
eNIT_NARTAX_INDORE_CIVIL.pdf
Tender Documents • 1.92 MB
PREFERRED_MAKE_LIST_ELECT_STREET_LIGHT.pdf
Additional Documents • 0.04 MB
BOQ_938529.xls
BOQ • 2.42 MB
PREFERRED_MAKE_LIST_CIVIL.pdf
Additional Documents • 0.05 MB
Download all tender documents and submit your bid