EnM HP I
HAIDERPUR WATER WORKS DELHI 110085
Servicing/ Renovation of LT panel with replacement of protection relay at RWPH, HPWW - I.
2020_DJB_189632_1
NIT No. 28(2019-20) Item No. 9
Open Tender
Miscellaneous Works
Item Rate
60 days
HAIDERPUR WATER WORKS DELHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹13,000
26 Mar 2020
14 Mar 2020
20 Mar 2020
14 Mar 2020
20 Mar 2020
14 Mar 2020
Digital Amp meter /05, Make -L&T
Indicating Light RED/GREEN- make- l&t
Digital Microprocessor based protection relay, 3phase Overcurrent and earth fault Relay 3Ph, with CT Rating 1A/5A, make-L&T
SP MCB 6 Amp, MAKE-L&T
Control Wire 1.5mm
Aux. relay, 2-4 Changeover Relay With Base, MAKE- Omron
Dismantling of old existing Amp. Meter from Lt panel after disconnecting the wiring connections after proper shutdown conditions and discharging of the CTS .
Making the required wiring connections between the meter and Amp meter Sel. switch as well as CTS, Laying and connecting of copper wire including thimbling and providing all consumables as required.
Dismantling of old existing IDMT Over current relay from Lt panel after disconnecting the wiring connections after proper shutdown conditions and discharging of the CTS .
Installation of new IDMT Over current relay and making the required wiring connection between the IDMT relay and protection CTS. laying and connecting of copper wire including thimbling and providing all consumables as required.
Testing and commissioning of new installed relays for their required operation and tripping configuration and sitting of fault levels of the relays and checking for their fault tripping commands/indication.
Dismantling of old existing TNC SWITCH from Lt panel after disconnecting the wiring connections after proper shutdown conditions.
Checking the wiring and Making the required wiring connections between the TNC switch and ACB, Laying and connecting of copper wire including thimbling and providing all consumables as required.
Dismantling of old existing indication LED from LT Panel after disconnecting the wiring connections after proper shutdown conditions.
Making the required wiring connections between the indication LED and control MCB as well as incoming bus bar, Laying and connecting of copper wire including thimbling and providing all consumables as required.
Dismantling of old existing aux. control relay and control fuse from Lt panel after disconnecting the wiring connections after proper shutdown conditions.
Making the required wiring connections for aux. control relay, laying and connecting of copper wire including thimbling and consumables as required.
Dismantling of outgoing power connections from outgoing bus bar and checking the CTS connections & continuity, Reassemble the power cable with bus bar after proper shutdown conditions and discharging of the CTS.
Dismantling of BUS BAR connections, Reassemble, Rectification, alignment, cleaning and tightening of all out going bus bar sec and including required consumables.
Assembling of all panel parts, Testing & commissioning of the LT PANEL, checking the incoming and outgoing power supply
ABS ELECTRICAL COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .