Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.3 LAccepted-AOC | L-1 | Accepted-AOC Accept | |
| 2 | L-2₹24.6 L+₹33,463 (1.38%)Rejected-Finance | L-2 | Rejected-Finance High Rates | |
| 3 | L-3₹25.4 L+₹1.2 L (4.79%)Rejected-Finance | L-3 | Rejected-Finance High Rates | |
| 4 | L-4₹26.3 L+₹2.1 L (8.53%)Rejected-Finance | L-4 | Rejected-Finance High Rates | |
| 5 | L-5₹26.8 L+₹2.6 L (10.6%)Rejected-Finance A SECTOR BHAGWATI BHAVAN VIJAY NAGAR LAL GHATI BHOPAL M P 462030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L-5 | Rejected-Finance High Rates |
Tender Value
₹33.0 L
EMD Value
₹66,060
Closing Date
26 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (MCTE)
GE (MCTE) Mhow (MP) 453441
SPL REPAIR TO BLDG NO WB-356/D AND WB-356/E AT AIR FIELD AREA UNDER GE (MCTE) MHOW
2023_MES_631309_1
GE(MCTE)/MHOW/41(T) OF 2023-24
Open Tender
Civil Works
Works
180 days
GE (MCTE) Mhow
As Per Tender Document
9 documents required · 9 mandatory
₹500
Yes
GE (MCTE) Mhow
₹66,060
Yes
2 Feb 2024
6 Dec 2023
28 Dec 2023
6 Dec 2023
26 Dec 2023
20 Dec 2023
Amount
B/R WORK
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors/ walls laid bedded and pointed in any mortar, complete all as specified and directed.
Demolition of Brickwork of stone/ boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Cutting openings, cement mortar through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down Chowkhats with shutters (without taking off shutters from the frame) area exc 1.5 Sqm but nexc 4.0Sqm each complete as specified and directed.
Taking down Chowkhats with shutters (without taking off shutters from the frame) and Refixing in other opening area exc 1.5 Sqm but nexc 4.0Sqm each complete as specified and directed.
Taking down Chowkhats with shutters (without taking off shutters from the frame) area not exc 1.5 Sqm each complete as specified and directed.
M & L for 25mm thick plain cement concrete 1: 2: 4 type B-0 using 12.5mm graded stone aggregate as in base floor or maintain to even surface complete all as specified and directed.
M & L non skid ceramic tiles 7 to 8mm thick of any shade (square/ rectangular) area of each tile as in floors exc 0.18 and not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bedding layer in cement sand mortar 1:6 complete all as specified and directed.
All as per item No 10 but on vertical surfaces such as skirting including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
M&L for non skid ceramic tiles 7 to 8mm thick of any shade (square/ rectangular) area of each tile as in floors exc 0.11 and not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bedding layer in cement sand mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured wall tiles (textured and design as required) in vertical surface 450 x 300 x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in 1:4 CM complete all as specified and directed.
M&L for 16 to 18mm thick Granite (of any type) work (table rubbed and polished and exposed visible edge moulding/ rounding) in steps, jambs, pillars, window cills, cooking platforms and like in & including 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
M&L for Machine cut mirror polished kota stone slab flooring with rounded edge 20-25mm thick over & including cement screed bed (1:6) 15mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab in and including grinding & mirror polishing complete all as specified and directed.
M&L for Machine cut kota stone skirting 18-20mm thick in riser of steps skirting, dado, and pillar over & including 10mm thick backing coat in cement mortar in (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding and mirror polishing complete all as specified and directed.
M&L for brick work built in cement mortar (1:6) using sub class “B” bricks straight or curved on plan exceeding 6 mtr mean radius complete all as specified and directed.
M&L for brick work with modular size kiln well burnt sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:4,complete all as specified and directed.
M&L for 75mm thick cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base under floors complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection finished even and fair incl cutting joints and filling with bitumen and sand mixture complete all as specified and directed.
Taking down cement plaster on brick wall/ ceiling built in cement mortar including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of concrete/ brick interior surfaces in cement mortar 1:6 finished fair and even without using extra cement complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of concrete/ brick exterior surfaces in cement mortar 1:4 finished fair and even without using extra cement complete all as specified and directed.
M&L for rendering, 05mm thick in cm 1:4, on ceiling surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M & L for rendering 15mm thick on chajja in two layers Ist layer 10mm in cement mortar (1:4) on faces of brick work and 2nd layer 5mm in cement mortar (1:4) and finished the surface fair and even using WPC complete all as specified and directed. Note :- WPC shall be measured and paid separetely, complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed with four year gaurantee.
M & L for preparation of newly plastered surface of wall and applying two coats of acrylic oil emulsion paint over a coat of alkali resistance primer and 2mm thick cement base wallcare putty complete all as specified and directed with four year gaurantee.
M &L for preparation of newly plastered surface and applying three coats of white wash on ceiling surfaces complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of of wall, washing, scrubbing down and stopping of disterpered and painted surface old plastered/ decorated surface and applying 2mm thick cement base wallcare putty for smooth finish of the surface and applying two coats of distemper oil emulsion over a coat of alkali resistance primer complete all as specified and directed.
M&L for preparation of old plaster surfaces of ceiling and applying two coat of white wash, complete all as specified and directed.
M&L for applying two coat of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface, complete all as specified and directed.
M&L for preparation of Old steel surfaces of any description, over 10 cm width or girth and applying one coats of synthetic enamelled paint complete all as specified and directed.
S&F powder coated aluminium ventilator, half portion of the ventilator covered with 5.5mm thick frosted glasses and half portion fittted with frosted louvers and outer side fitted with mosquito proof galvanised wiremesh including removing old steel ventilators incl finishing the demolished surfaces with rendering 10-15mm thick CM 1:4 of fair finshes including filling the holdfast holes with PCC 1:2:4 (12.5mm graded aggregate) including 02 coats of cement based paints with primer incl all fittings, accessories etc complete all as specified and directed.
S & F of Powder coated aluminium three track sliding shutters two Glazed shutters and one guazed shutters(with wire mesh), each shutter width one half of the length of window with the following specifications and making good the adjacent surfaces. (i) Three way track for sliding shutters of cross section 91.80mm x 31.75mm x 1.30mm thick. (ii) Sliding shutter frame of cross section 40 x 18 x 1.30mm. (iii) Aluminium glazing strip of size 18.2 x 16.66mm. (iv) 4 to 5mm thick float glass superior quality make Modi float for two shutters. (v) IDPE rubber gasket for fixing glass. (vi) Locking cleat per shutter - 01 No. (vii) Two nos sliding rollers per shutter. (viii) Rubber shock absorber - 03 No per shutter. (ix) Aluminium wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm for one shutter. (x) Fixing screws for frame with wall - 06 No per window.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/ or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed.
S&F in repairs 18mm thick factory made PVC sheet one side pre-laminated sheet ktichen cabinet shutter. The 18mm thick sheet shutter bent at 90 degree and finish all edges at level for marking edge lipping bending for 0.5mm thick PVC sheet lipping at all four edges using bonding tape etc complete all as per specified and directed by Engr-in-Charge manufactures specification.
S & F in repairs factory made PVC shelf/ partition of required size consisting of panel of 18mm thick required size consisting of panel of 18mm thick celuka PVC ply and for supporting the hold of shelf/ partition and shall provided 3 edges in size 18mm x 18mm as per required lenght the front side of the edge visible in the front of the shelf/ partition to be edge lipped by 18mm widht x 1mm thick PVC sheet of density 600 kg/cum manufactured by ISO 9001-2015 Certified Company, using solvent cement, complete all as specified and directed.
S & F in repairs factory made PVC shelf/ partition of required size consisting of panel of 12mm thick required size consisting of panel of 12mm thick celuka PVC ply and for supporting the hold of shelf/ partition and shall provided 3 edges in size 18mm x 18mm as per required lenght the front side of the edge visible in the front of the shelf/ partition to be edge lipped by 18mm widht x 1mm thick PVC sheet of density 600 kg/cum manufactured by ISO 9001-2015 Certified Company, using solvent cement, complete all as specified and directed.
S&F in repair anodised aluminium curtain rod/ rail 25mm dia and thickness not less than 0.75mm complete all as specified & directed.
S&F in repair Stainless steel curtain rod brackets 25mm dia including necessary stainless steel clamp complete all as specified & directed.
S&F stainless steel shelf closing hinges 75mm size for PVC door shutters complete all as specified and directed
S&F 50 x 15mm size magnet door catcher for closing for PVC door shutter complete all as specifid and directed .
S& F 100mm size MS mat/ glossy finish handle complete all as specfied and directed.
S&F Hasp & staple aluminium anodised, safety type, including bolt to hinge plate and fixed with screw 100mm size, complete all as specified and directed.
S&F door spring with 300mm mild steel rat rail rod pattern of standard quality including roller and roller plate complete Helical spring), complete all as specified and directed.
S&F in repairs Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
S & F under counter ivory wash basin, vitreous china size 560 x 410 x 180mm including cutting for and pinning in ends of brackets or erecting stand but incl wastecoupling and brackets, fixing of supply and waste pipe, Rag Bolt Assy 3/8" complete all as specified and directed.
S & F in repairs Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device
S&F in repairs low level Flushing cistern 10 ltr capacity, PVC valveless syphonic action type, white with inlet, ball valve, float valve and handle, flush pipe, incl brackets and flushing pipe fixed in repairs complete all as specified and directed.
S&F in repair chromium plated brass wall mixer 2-in-1 fancy type with provison for both hand shower and overhead shower complete with wall flange without hand & over head Shower screwd down for 15mm GI bore pipe complete all as specifed and directed. Make : Jaquar Cat Part No CON-CHR-273KNUPR & techno communally equivalent tlid/ Marc, Plumber, Cera
S&F in repair chromium plated brass Central hole basinmixer without popup waste system complete screwd down for 15mm GI bore pipe complete all as specifed and directed.
S&F in repair chromium plated brass Sink mixer waste system complete screwd down for 15mm GI bore pipe complete all as specifed and directed.
S&F in repair 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified.
S&F in repairs kitchen plate rack with and including shelves and hanging arrangement for utensil for kitchen, made of stainless steel sheet 0.63mm thick size 30" x 36" x 10" complete all as specifed and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with all plugs, washers, fittings and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specifed and directed.
S&F in repair 15mm size PVC connections internally threaded with PVC washer, PTMT nuts of length 450mm complete all as specified and directed.
S&F Grating 100mm dia of CP with or without hole complete all as specified and directed.
S&F in repair 15mm dia bib tap cast copper alloy (fancy type), chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specifed and directed.
S&F in repair 125mm size Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specifed and directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long complete all as specifed and directed.
S & F in repairs Stop/ angle cock 15mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions,complete all as specifed and directed.
S & F in repairs two way Stop/ angle cock 15mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specifed and directed.
S&F in repairs Health Faucet ABS with Rubbit Cleaning System, 1.25 m Long PVC Flexible Tube & ABS Wall Hook. complete all as specifed and directed.
S & F in repairs aluminium alloy brackets and guard rail 5.5mm Glass Shelf of Size 12mm wide 60mm long complete all as specifed and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re fixing complete all as specifed and directed.
S&F, laying and testing for 15mm bore GI tubing medium grade galvanised steel tubing including all fittings such as union, reducer, sockets, reducing bends elbows tee, checknuts, caps, plugs etc fixed to wall and ceilling or laid in floors complete all as specifed and directed.
Taking up or down steel tubing and connections for bore of tube 20mm, complete all as specified and directed.
S&F GI tubing Medium grade galvanised with all fitting and fixed bore of tube 20mm, with necessary union, socket, nipleetc complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in CM(1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in Stone, concrete block or slab walls.
Taking down Old PVC or AC rainwater/waste/vent pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fix to wall l all as spcified.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fix to wall complete all as specifed and directed.
S&F PVC (SWR) Bends (any radius), diminishing pieces or tapers, bore of pipe 75mm, complete all as specifed and directed.
S&F PVC (SWR) Bends (any radius), diminishing pieces or tapers, bore of pipe 110mm, complete all as spcified.
S&F in repairs PVC (SWR) Branch pieces, double (double Y) equal or unequal of pipe 75mm bore complete all as specifed and directed.
S&F PVC (SWR) Branch pieces , double (double Y )equal or unequal of pipe 110mm bore complete all as spcified.
S&F PVC floor trap, with grating 75mm including jointing to wast pipe fixed in cement concrete type B1 (1:2:4), in repairs and including water leak proof treatment complete all as spcified.
Dismantling water tanks and removing to store exc 500 & n. exc 1000 litres capacity
S & F Rotational moulded polyethlene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I 1000 litres capacity., complete all as specifed and directed.
S&F in repair 20mm dia Ball valves, of PTMT high pressure, with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15 to 25mm to 142 - 455 gms), complete all as specifed and directed
S&F in repair 20mm dia Gun-metal, golbe or gate valves, with iron wheel head, screwd both ends or iron pipe and fixed, complete all as specifed and directed.
Taking down existing waterproofing treatment of tar felt of any description from roof surfaces and removing rubbilsh to a distance not exc 100mtres complete all as specified and directed
M&L for PCC 25mm thick (1:2:4) type Bo using 12mm graded stone aggregates mixed with integral waterproofing chemical PIDI PROOF-LW mixed in proportion of 200ML/50Kg cemet of DR fixit of pidilite industries Ltd or STP No.1 (Liquid) of STP Ltd in proportion 200ML/50Kg cement as in padding on roof surfaces for correcting/ making proper slope on roof/ chhaja and roof kerbs/ benching complete all as specified and directed.
M & L for Water proofing on roof/ parapet with the follwing steps including testing & 10 year gaurantee:- STEP-1. Firstly to clean the existing surface of the roof for preparation and making the surface dust free. STEP- II. Opening of crack in V groove more than 0.5mm and filling with epoxy mortar. STEP-III. Initial coat (mixed 1/2 litre of water in 1 litre of Roof seal of Asian paint/ PIDILITE/ STP/ FOSROC/ ACC/ L&T/ MARUIT. Dr. Fixit) as a primer (Area cover 1 litre = 9-10 sqmtr) STEP-IV. After six hours of primer, apply first coat (one coat) of Asian paint/ PIDILITE/ STP/ FOSROC/ ACC/ L&T/ MARUIT. Dr. Fixit roof seal in a particular direction without mixing of water. Now left it for six hours (Area cover 1 litre = 1.2 sqmtr). STEP-V. After again six hours of first coat and apply the second coat of Dr. Fixit Roof seal in a other direction without mixing of water (Area cover 1 litre = 1.2 sqmtr). Now left for 24 hours. all as specified and directed by engr-in Charge. Note :- The work of water proofing treatment shall be got executed through expert team of manufacturers of authorised applicator of manufacturer. Make Asian paint/ PIDILITE/ STP/ FOSROC/ ACC/ L&T/ MARUIT or equivalent approved complete all as specifed and directed.
M&L for 10mm thick screed bed on concrete surfaces in CM (1:3) finished even and smooth without using extra cement complete, complete all as specifed and directed.
M&L for Cement concrete type B-2 1:5:10, 40mm graded stone aggregate filling and mass-concrete in sunken floor complete all as specified and directed.
M&L for water proofing treatment to sunken surfaces of the slab in following sequences:- (for 10 Years Gaurantee)
Water proofing Application : Providing and applying acrylic cement two component water proof coating Dr. Fixit Hydrocem/ Dr. Fixit pidifin 2kin two coats @ 0.55-0.58 Sqm/Kg/2 coats having minimum elongation of 50% Allow the coating to application in a direction perpendicular to the first. Vertical portion coating should be applied up to a height of 1 Mtr.
Horizontal protection & slpoe : Providing & laying 50mm THK protective screed of Cement Concrete of 1:1.5:3 mix admixed with integral compound conforming to IS 2645:2003, Dr. Fixit Pidiproof LW+ @ 200ml per bag of cement or Brick Bat Coba in the sunk area, to provide slope to the horizontal surface towards drain outlet and also to protect the waterproofing, keeping the surface broomed, curing and testing for water tightness for 7 days etc. complete all as specifed and directed
Vertical protection : Apply a spatter dash bond coat which comprises of Cement: Dr. Fixit URP : Silica sand (1:1:1.5) over the cured waterproofing coating and apply the key coat of plaster as wet on wet application. The plaster should be placed approx. 12-15mm thick plaster in two coats over the prepared surface of cement sand mortar admixed with integral waterproofing compound Dr. Fixit Pidiproof LW+ forming to IS 2645:2003 @ 200 ml per bag of cement.
E/M WORK
Taking down carefullycopper/ aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc, and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
Taking down carefully copper/ aluminium sub-main wiring any type and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
Taking down carefully MCB DBs/ sheet metal earth plug socket any size and any type including MCBs any type and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
Taking down existing geyser any size in position and re-fixing the same after B/R work including painting of the same with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, with and including providing three core flexible copper cable for connection from ceiling rose/ connector complete all as specified and directed by Engr-in-Charge.
Taking down existing ceiling fans any size in position and re-fixing the same after B/R work including painting of the same with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, with and including providing three core flexible copper cable for connection from ceiling rose/ connector complete all as specified.
Point wiring with 1.5 Sqmm (nominal cross sectional area), single core, PVC insulated with multistranded PVC unsheathed FRLSH copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked complete, including one continuity earth wire of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area) FRLSH copper conductor connected to all fittings, common earth and connected to earth dolly including metal flush box, modular cover plate suitable size and cover frame of suitable size all fittings and accessories and making good disturbed surface of walls and floors etc. complete all as specified for the folowing:-
(a) One light/ fan/ bell point controlled by one/ two way switch complete all as specifie.
(b) One 5 Amps socket out let point controlled by one switch on SAME BOARD with other switches complete all as specified.
(c) One 5 Amps socket out let point on independent board controlled by one switch complete all as specified.
All as per item No.100 here in before but using pvc insulated FRLSH unsheathed 2.5 sqmm cross sectional area cable for phase/ neutral & for earth 2.5 Sqmm green PVC insulated cable for FRLSH 15 Amps socket point on independent board controlled by one switch complete all as specified.
Supply and fix in repairs Modular Switch flush type 6 Amps single pole, one way complete all as specified.
Supply and fix in repairs Modular Socket outlet, multi purpose, 5 Pin combined 6 Amps flush type complete all as specified.
Supply and fix in repairs Modular Bell push flush type, 6 Amps complete all as specified.
Supply and fix in repairs Modular Socket outlet, multi purpose, 2/3 pin combined 16 Amps universal socket complete all as specified.
Supply and fix in repairs Modular Switch 16 Amps single pole, one way complete all as specified.
Supply & fix in repairs modular fan regulator step type, 2 module type complete all as specified.
Supply and fix in repairs Bell, ding dong type, AC 230 Volts, single pole complete all as specified.
S&F in repairs ceiling rose surface bakelite three terminal complete all as directed.
S&F in repairs lamp holder insulated body with back plate for batten fittings complete all as specified.
Supply and fix LED bulb of 7 watt, Of base B-22, suitable for fixing in lamp holder complete all as specified.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient high transmissitivity diffuser, high lumen ouput 230 volts and intregrated electronic driver connector block etc. complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make :- Havells Cat Part No LHEXBLP7PN1W022 or equivalent approved.
S & F for LED 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. Make : Havells Cat Part No LHEXACP7IN1W010 or equivalent approved.
Supply & fix Surface/ Recessed mounted LED panel 15 w, slim, compact round LED panel of 15 W plastic body with premium diffuser to ensure glare free & even distribution of light complete all as specified
S & F for Decorative wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base and including fixing of LED bulb 10 watts complete all as specified and as directed. Make : Havells Cat Part No LHFOAJE1TZ1I060 or equivalent approved
Supply and fix in repairs double door SPN DBs eight ways of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din ral complete.
Supply and fix MCB SPN 6 to 32 Amps 10 KA, 'C' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed by Engr-in-Charge.
Supply and fix MCB SP 6 to 32 Amps 10 KA, 'B' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed by Engr-in-Charge.
M&L for single pole and neutral encolsure with a two pin and earth plug with socket 240 Volts, 50 Hz complete with one single pole MCB SP 20 Amps complete all as specified and directed.
S & F for Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 for Bldg security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make : Bajaj Cat Part No ENXT P 24L WH CR PC SD (Edge plus series) or equivalent approved.
Supply and Fix in repairs flush mounting factory made Vertical FP DB, IP-43 Protection -IK 09 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of space for 100-125 Amps MCCB as incomer and SPN/ TP MCBs as out going, 6 way (Optimum 1+18 Module) complete all as specified.
Supply and fixing 415V 10KA 'B' 63 Amps curve miniature circuit breaker (MCB) of TPN/ 4 poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply & fix plastic body exhaust fan, AC single phase 230/ 240 V of size 250mm sweep with louver, white in colour including cutting of wall and duly connection with copper wire from ceiling rose etc complete all as specified and directed. Make : Havells Model Ventil Air-DX White or equivalent approved in Crompton/ Almonard
S&F modular TV socket as following :- (a) TV socket 1 module Make : Havells Cat Part No AKOKTOW061 or equivalent approved - 01 No. (b) Modular with plate for TV socket - 01 No (c) Plastic flush boxes for 1 module jack
Taking down carefully serviceble KWH Electric Meter single phase any type and re fixing the same after completion of the work with wooden rectangular board making good the disturbed surface of walls and floors etc complete all as specified.
S & F Rigid non-metallic PVC 20mm dia conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipehooks etc complete all as specified.
M&L in repairs for Sub main wiring in repairs with two runs of single core PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia including one run of PVC insulated unsheathed 4 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, Innovative 20 W Led batten that works automatically through motion detection within 5 metre range & turn off within 30 seconds of non movement 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make : Havells Cat Part No LHEXARP7UN1W020 or equivalent approved.
M & L for earthing complete with galvanised steel earth plate 600 x 600 x 6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised Iron Wire of size 4 sqmm as earthing lead by means of bolts, nuts, cheek nut and washers of galvanised iron or steel besides at all joints as shown in Electrical Plate No-3 of SSR Part-I and including excavation and earth work GI pipe 20mm dia light grade protection pipe and including charcoal filling common salt, PCC 1:3:6 type CI using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 6mm and RCC cover 40mm thick (1:2:4) type B-1 using 20mm dia graded stone aggregate reinforced with 6mm dia round bars @ 75mm c/c both ways with MS handle 12mm dia, CI funnel and wire mesh 20mm dia GI pipe medium grade for watering and connected to earth Test point (Including testing complete all as specified and directed).
Jamna Constructions
GIRIRAJ CONSTRUCTION AND TRADERS
M/S Umashanker Mishra
JYOTI ENTERPRISES
J B CONSTRUCTION AND DEVLOPERS
RK CONSTRUCTION
sunway associates
BHATIA ASSOCIATES
SATHI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .