Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹30.6 L+₹5.2 L (20.5%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹34.8 L+₹9.4 L (36.9%)Rejected-Finance MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹35.2 L+₹9.8 L (38.7%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹25.5 L
EMD Value
₹51,000
Closing Date
22 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI JANAK RAJ EE GARRISON ENGINEER NW
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802.
8316/E8
2020_MES_397094_2
8316/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class D Category b i
8 documents required · 8 mandatory
₹500
Yes
GE NW VASCO
₹51,000
Yes
29 Dec 2020
7 Dec 2020
24 Dec 2020
7 Dec 2020
22 Dec 2020
8 Dec 2020
7 Dec 2020 - 8 Dec 2020
60 days
Amount
SPECIAL REPAIRS TO VHF/DF HUT BLDG. NO. P/10 AT INS HANSA (B/R-I Portion)
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L Rendering 15 mm thick cement plaster on concrete solid block walls in CM 1:4 finished to even & smooth w/o using extra cement.
M&L Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid seperately.
M&L Rendering 5 mm thick cement plaster on ceiling with 3% integral water proofing compound. Note :- Integral water proofing liquid will be measured and paid seperately.
M&L Preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling.
M&L Preparing new plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall
M&L Preparation of New/old plastered surface and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer
Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled as directed by Engr-in -charge.
M&L Providing 10mm thick plaster in CM (1:4) mixed with 3% integral water proofing compound over roof top surface finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid seperately
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the mother slab. Filling the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalant) on prepared concrete / plastered surface by diluting 2 parts of Primeseal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating (Dr. Fixit Newcoat / Waterseal Concentrate of M/s Krishna Conchem Products) without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completly. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions.
Supply only water proofing compound
Dismantling floor / wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises
Demolition of Stone slabs of any description or thickness in floors, aprons etc.
M&L Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M & L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of internal flooring/plinth protections, etc.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment
M&L 50 mm thick Sand filling under floors or in foundations including watering and consolidation
M&L screed bed or bedding layer of mortar 20 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles.
M&L Rendering 10mm thick in 1:6 CM on fair faces of block work or concrete surfaces to receive glazed tiles
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L Glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match
Taking down chowkat or frames n exc 1.5 sqm each (w/o taking of shutters from the frame).
Taking down chowkat or frames exc 1.5 sqm but n. exc 4 sqm each (w/o taking of shutters from the frame and removing to store)
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F butt hinges medium weight stainless steel 100mm size
S&F Extruded aluminium alloy handles, fabricated type, anodised 100 mm grip size .
S&F Aluminium anodised, barrel tower bolts of extruded section and fixed 150mm size
S&F Aluminium alloy, anodised, sliding door bolt 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F powder coated aluminium door and window shutter and frame any type (sliding or openable) and other similar work etc 60 micron powder coated section, fabricated by using the JINDAL / INDAL / HINDAL CO / CENTURIAN sections including all necessary roller wheels for window, cleats , handle, door stoper locking arrangement and arrangements to received glass/ prelaminated particle board with aluminium beading and stainless steel screw incl cost of rubber gasket beadings etc complete sealing between frame & wall with epoxy sealing compound. (The weight of rubber gasket beading will not be measured with the weight of aluminium shutters, glass and prelaminated particle board will be measured and paid seperately) All sections as approved by GE.
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and directed
S&F 4mm thick sheetglass ordinary quality exceeding 0.5 sqm each pane
Solar control film 50 micron reflective type mirror finish / mirror jet black type(gareware sun control or equivalent)
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .
All as per item No. 1.35 above but of 25 mm dia
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm.
All as per item No. 1.37 but of 25 mm dia
S&F in repair PVC Connections 15mm size with PTMT nuts of length 450mm
Dismantling of cast iron/AC drain pipes jointed in cement mortar
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S & F 75 mm bore PVC (SWR) bends of any radius
S&F in repairs Bib tap standard 15mm of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm-125gms).
S&F in repairs Stop valve 20mm dia of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms
S&F in repairs Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms) 15mm
S&F in repairs Wash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand and coupling but exclusive of fixing of supply and waste pipe but including waste fittings
M&L Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 75 mm dia
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white including seat cover (excluding fixing bolts, flushing cistern and flush pipe)
S&F in repair PVC valveless, syphonic action type flushing cistern, low level , white, with inlet ball valve, float and handle including brackets 10 litres capacity .
S&F for hand shower (Health faucet) dia 8mm 1 mtr long flexible tube and wall hook Cat No ALD 573 of Jaquar or equivalent in Parko/Kohler
S&F in repairs Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
S&F in repairs Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges .
S&F in repairs Soap dish, of material brass with glossy finish,Cat No. BA-45 of Prayag or equivalent.
Dismantling old damaged PVC/AC water tanks and removing to store exc 250 and not exc 500 ltrs capacity .
S&F in repairs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 Ltr capacity hoisted and fixed in position all as specified in SSR Part I .
S&F in repairs gun metal glove or gate valves with iron wheel head screwed both ends for union pipe and fixed 20mm dia pipe .
S&F ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass frame and 20mm bore .
SPECIAL REPAIRS TO VHF/DF HUT (P-10) - INS HANSA (E/M - I Portion)
Taking down old unserviceable / perishable sub main wiring of any size /core /type from the ceiling of hanger complete with PVC / steel conduit / PVC casing capping including earth continuty conductor, junction boxes etc and making good the disturbed surfaces all as directed by Engr-in-charge.
M & L for Street light bracket made out of GI tubing 40 mm dia, light grade bend to shape suitable for above mentioned security light fittings with necessary MS clamps with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers etc including taking out old unserviceable complete as specified.
Supply and fix in replacement of 60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen / Watt (Minimum lumen output of luminarie should be 6000 Lumens) The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. The manufactures LOGO must be embossed / Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge.
M & L Point wiring in replacement with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit 20 mm dia medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly including (PVC / Wooden box of suitable size with laminated sheet cover of 3 mm thick for mounting swiches,socket,regulator) complete.
a) for light , fan point controlled by one way switch
b) for 5 Amp Socket point on same board
c) All as per Srl item No 1.62 above but 5 Amp point on independent board
S & F ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body completed all as specified and directed.
S & F in repairs Modular switch 1 way 6A, 1 module all as directed.
S & F in repairs Modular switch 1 way 16A, 1 module all as directed.
S & F in repairs Socket, 6A - 2/3 pin combined 2 module, all as directed.
S & F in repairs Socket 6A/16A - 2/3 pin combined 2 module, all as directed.
S & F in repairs Fan step regulator, 120W - 2 module all as directed.
S & F in repairs White cover plate with frame, 2 module all as directed.
S & F in repairs White cover plate with frame, 2 module all as directed.
S & F White cover plate with frame, 6 module all as directed.
S & F White cover plate with frame, 8 module all as directed.
S & F Metal flush box 1/2 module all as directed.
S & F Metal flush box 3 module all as directed.
S & F Metal flush box 6 module all as directed.
S & F Metal flush box 8 module all as directed.
M&L for point wiring with FRLS cable size 2.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor in PVC concealed conduit for one 3 pin, 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engr-in-Charge.
M&L for Point wiring with FRLS cable size 4 Sqmm (nominal area) PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly for geyser/Ac point.
S & F 20/25 Amps motor starter switch with overload protection, ideal & safe for air conditioners cooler, water pumps, refrigerators Mixer and all type of appliances completer all as specified and directed by Engr-in-Charge.
S & F 20/25 Amps Power unit combo MCB protected socket with top, ideal & safe for air conditioners cooler, water pumps, refrigerators Mixer and all type of appliances completer all as specified and directed by Engr-in-Charge
S & F MCB TPN 63 Amps 415 volts all as specified and directed by Engr-in-charge.
S & F MCB SP 6 to 32 Amps 240 Volts all as specified and directed by Engr-in-charge.
S & F MCB SPN 6 to 32 Amps 240 Volts all as specified and directed by Engr-in-charge.
S & F RCCB 4 Pole 100 mA 63 Amps all as specified and directed by Engr-in-charge.
S & F vertical MCB DBs VTPN 4 Way sheet steel, phospetised, powder coated with 200 Amps rated bas bar double door, 415 Volt all as specified and directed by Engr-in-charge. .
S & F MCB DB SPN 8 ways sheet steel enclosure, phospetised, powder coated with double door, 415 Volt all as specified and directed by Engr-in-charge.
Supply and fix in repair Hanger obstruction light fitting Aviation yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories LED type suitable to 230 V AC protection weather proof IP66as per IS2147 sealed against water and dustscomplete all as specified and directed by Engr-in-charge.
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm alongwith one run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through PVC conduit as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area.
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through pvc conduit as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area.
Supply and lay cable XLPE insulated screended PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 3 core.
Supply and lay GI Pipe light grade 25 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed by Engr-in-charge.
S & F DB mounted MCB type indicating lamp single phase Red/Yellow/Blue.
S & F DB mounted MCB type indicating lamp Three phase Red+Yellow+Blue.
S & F LED batten for surface and pendant applications, anodized extruded aluminium housing, high transmissitivity diffuser and high lumen output 20 W 230 V
Supply and replacement of Earth continuity conductor or main earthing lead of 20X3 mm copper strip fixed to wall on insulators or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified.
Supply and replacement of air termination sigle pointed copper rod of 12mm dia 300mm length bolted to copper / aluminium strip 25x3mm including nuts, bolts and washers complete all as specified and directed the Engr in charge.
REPLACEMENT/MAINTENANCE OF GARDEN LIGHTS IN FRONT OF BUILDING P/250 (VIP ANNEXE) AT INS HANSA.
Supply and fix in repairs integral decorative LED 6 W bollard light with Die cast aluminium body opal white PC diffuser IP 54 protection including connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded from eletrical connection in junction boxes, complete mounting on PCC block/foundation including growting bolts and nuts making necessary complete all as specified and directed by Engr-in-charge.
Supply, laying, testing and commissioning LT Cable XLPE insulated, galvanised steel strip armoured,1100 volts grade, multistranded aluminium conductor cable of cross sectional area 10 sqmm; 04 core conforming to IS:7098 part-I with latest amendments upto date and making cable connections by providing suitable aluminium lugs with proper crimping and steel glands and laid in trenches / ducts / floors / roofs or through pipes with saddles and fixing screws etc complete all as specified and directed. Note :- 1. Excavation, Concrete cable protection cover and Clear Sand for cushioning will be measured and paid separately. (b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape) new nut, bolt and washers of required size/description are deemed to include in this rate.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated 3 core stranded copper conductor served with an inner sheathing of PVC tape PVC sheathed 4 sqmm nominal cross section in service connection / light connections in garden light from juction box to fittings, including taking out old unserviceable cable complete all as specified and directed by Engr-in-charge.
All as per item No.3.03 here in before but of size 3 core 2.5 sqmm
Supply and fix in repairs cable junction boxes IP 68 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for 3 way cable entry) of incl necessary suitable size new aluminium busbar single phase with neutral system under ground electrical cable protection suitable length and thickness, provn of aluminium cable lugs for incoming & out going LT cable connections with junction box complete all as specified and directed by Engr-in-charge.
Supply and fix MCB 4 pole 415 volts 63 Amps breaking capacity 10 KA in outdoor junction box sheet steel enclosure with in 2 mm thick CRCA sheet metal enclosure , powder coated, weather proof fixed on MS angle iron frame of suitable size duly painted and mounted above the floor level with necessary PCC foundation/platform in PCC 1:2:4 type B1 and including connecting of incomming and outgoing wire with suitable lugs, glands, nuts, bolts and washers all as specified and directed by Engr-in-charge.
Supply and fix or laying in trenches PVC pipe heavy duty for cable protection/fixing of garden lights etc, of the following sizes including necessary tee/elbow/junction box etc. provision for cable entry if reqd in garden lights complete including taking out old unserviceable pipe as required complete all as specified and directed by Engr-in-charge.
(a) 25 mm dia
(b) 20 mm dia
Supply and fix or laying in trenches /on wall / poles /structures as in repairs GI tubing light grade for road crossing/for cable protection/fixing of pigmi lights etc,of the following sizes including necessary provision for cable entry if reqd in pigmi lights pole, fixing screws complete as required complete all as specified and directed by Engr-in-charge.
(a) 40 mm dia
Excavation in trenches not exceeding 1.5 Mtr wide and n.exc 1.5 Mtr in depth in hard/dense soil getting out and levelling of bottom surface to required level for removing of old pipes or laying of pipeline all as specified.
Excavation in trenches not exceeding 1.5 Mtr wide and n.exc 1.5 Mtr in depth in soft / disintegrated rock getting out and levelling of bottom surface to required level for removing of old pipes/ laying of pipeline all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard/ dense soil all as specified.
Removing excavated material of any type of soil/soft rock from site to a distance not exceeding 50 Mtr away and depositing where directed not exceeding 1.5 Mtr above the starting point all as directed.
Supplying & Laying in trenches Clear Sand / m- Sand for cushioning under ground cable 8 cm below and 15 cm above complete all as specified and directed by Engr-in-charge. Note: Punned thickness only will be measured and paid.
Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete complete all as specified and directed by Engr-in-charge.
REPLACEMENT OF BER SUMMER APPLIANCES AT RAQAS
Supply, install, testing and commisioning of split type air conditioner 1.5 TR capacity of 3 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, outdoor mounting bracket made of mild steel duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height including initial filling of refrigerant gas including making round hole on existing wall for taking up refrigerant tubing, drain pipe and cables etc and making good the disturbed surface by matching with existing adjoining surfaces and fix factory fabricated mild steel stand suitable for installation of out door unit of split type air conditioner fixing arrangement with anchoring bolts on wall surface at suitable height as per site condition complete all as specified and directed .
Dismantling carefully the existing split / Window type AC (indoor & outdoor unit) 1.5/2.0 TR capacity from the position keep in safe custody and deposite to MES yard complete all as directed
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA
S&F single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one MCB SP 20 Amps, 10 KA 'C 'series, 240 Volts complete all as specified and directed.
M & L for FRLHS sub main wiring with two runs of single core PVC insulated unsheathed 1100V grade multistranded copper conductor cable 4 Sqmm size incl PVC casing capping in wall incl one run 4 Sqmm PVC insulated unsheathed copper conductor cable as earth wire complete all as specified.
S & F MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed .
PROVISION OF 3 X 1.5 TR AIR CONDITIONERS WITH STABLIZERS AT NCN SERVER ROOM INS HANSA
S & F DB TPN 4 way, 415 volts, double door, factory made sheet metal enclosure with 100 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCB TPN 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connections complete all as specified and directed.
S & F MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA
S & F MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA
PROVISION OF WIRING OF 20 KVA DG SET IN OPS BUILDING (P-645) AT INAS 303 AT INS HANSA
M & L for sub main wiring with two runs of single core 6 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & incl PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 6 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed.
S&F MCB DB SPN double door 4 way 240 volts all as specified and directed.
S&F MCB DB TPN double door 4 way 415 volts all as specified and directed.
S&F MCB type 4 pole two way centre OFF changeover switch 63 Amp complete all as specified and directed
S&F MCB TPN 'C' series 40 Amp, 415 volts, 50 Hz, 10 KA complete all as specified and directed
S&F in repairs MCB SPN 06 to 32 Amp, 230 volts, complete all as specified and directed.
S&F in repairs MCB SP 06 to 32 Amp, 230 volts, complete all as specified and directed.
PROVISION OF FLAME PROOF LIGHT (02 IN NO ) AND EXHAUST FAN (01 IN NO WITH DIA 18" OR MORE) IN PAINTING ROOM AT GE WORKSHOP
M&L for point FRLS/LS wiring with 1.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor in and including steel conduit on surface with all fittings and fixing materials and PVC insulated multistranded copper earth continuity conductor of size 1.5 Sq mm connecting all as specified and directed by Engr-in-charge :-
S & F flameproof on off switch 230 volt, 50 Hz .
S&F flameproof exhaust fan of size 457 mm , 4000 rpm, single phase consisting of not less than 0.33 HP motor complete all as specified and directed by Engr-in-Charge.
Fluorescent tube light fitting. 1 x36W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specifed and directed by Engr-in-Charge
PROVISION OF WATER TANK (5000 LTRS ) AND 2 HP MOTOR IN OPS BUILDING (P-645) AT INAS 303 AT INS HANSA
Supplying, installing ,testing and commissioning of monoblock pump sets of 2 HP capacity with CI impeller, gland packing sealing, C-40, 1 phase, 230 V , AC with suitable size TEFC induction motor, Sync speed 1500 rpm IP -44, B class with delivery and suction head 40X50 mm
Supply and fixing DOL starter suitable upto 2 HP monoblock pump set single phase 230 Volt, relay range from 10.5 -17.5 A including making connections complete all as specified and directed by Engineer-in-Charge.
Supply laying and testing of water tank tripple layer 100% FDA grade material, stylish design, computerised ribbed design for better strength and fully hygienic, of capacity 5000 Ltrs including making all necessary pipe line connection all as specified and directed by Engr-in-Charge
Supply & Laying XLPE insulated, screened, PVC Bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed.
Supply, laying, jointing & testing GI tubing medium grade of size 25 mm dia laid in trenches with all fittings complete all as specified.
Supply, laying, jointing & testing GI tubing medium grade of size 50 mm dia laid in trenches with all fittings complete all as specified.
Supply, laying, jointing & testing GI tubing medium grade of size 40 mm dia laid in trenches with all fittings complete all as specified.
Supply & fix gun metal gate valve with iron wheel head screwed both ends size 50 mm for iron pipes complete all as directed by Engr-in-charge.
Supply & fix gun metal gate valve with iron wheel head screwed both ends size 25 mm for iron pipes complete all as directed by Engr-in-charge.
Supply & fix Non return valve of size 25 mm made up brass complete all as directed by Engr-in-charge.
M & L for cutting / jointing for addn / altn for taking out of branch connection for GI tubings of size 25 mm dia bore complete
M&L PCC 1:3:6 type C1 for foundation kerb using 20 mm stone aggregate including forming work as reqd at site.
M&L PCC 1:2:4 type C1 for foundation kerb using 20 mm stone aggregate including forming work as reqd at site.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
Rendering / cement plastering 15mm thick on fair faces of brick work or concrete surfaces in Cement mortor 1:4 finished even and smooth without using extra cement
PROVN OF LIGHTENING PROTECTOR FOR BUILDING P-676 AT RAQAS (GOA) AT INS HANSA
M & L for Earth Continuity conductor as Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engr-in-charge.
S & F Galvanised iron strip 32 x 6mm with saddles and fixing screws etc. for roof conductors and down conductors above ground incl taking out old one complete all as specified and directed by Engr-in-charge.
M & L for Air termination, single pointed, Alluminium rod 12 mm dia and 300 mm long , mounted on alluminium base plate of size 100mm x100mmx 12mm rigid fixed on top roof height complete and insulated from base and taking out old unserviceable complete all as specified and directed by Engr-in-charge.
M & L for test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and scrwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw complete all as specified and directed by Engr-in-charge.
Supply and lay pipe galvanized, “ Light grade ”, including fittings 40 mm dia.
PROVISION OF CHAIN LINK FENCING WITH GATE AT SANKALP VARUNAPURI (B/R II Portion)
Excavation in hard/dense soil in post holes (or similar holes) eache n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing excavated material to low line area from MoD land.
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, wind ties, etc.; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as directed.
S&F GI flat of any size as in fillets for securing chain link fencing including cutting drilling holes etc
M&L Cement concrete type C1 1:3:6 (40mm graded agg) in foundations, filling and mass-concrete in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) all as directed by Engineer -in-charge.
Supply only chain link MS galvanised fencing, any size or type
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provn of binding wire complete all as specified and directed.
S&F round bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia.
M&L applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
S&F Fe 410 W (Gde E-250) quality B for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, all as directed by Engineer -in-charge.
PROVISION OF EWC IN VARIOUS QTRS (10 NOS) AT SMA VARUNAPURI UNDER AGE B/R-II OF GE (NW) VASCO
Taking down chowkat or frames n exc 1.5 sqm each and refixing in the same opening (w/o taking of shutters from the frame)
M&L rendering 10mm thick in cement plaster 1:4 on stone masonry surfaces or surfaces other than fair face of brick work to receive glazed tiles.
S&F Non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm floors etc set and jointed neat cement slurry and pointed in white or coloured cement to match.
S&F glazed ceramic tiles 300 x 200 x 7mm thick coloured on vertical surfaces such as dado skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Dismantling flush tank and refixing including all fixing arrangement all as directed.
Dismantling WC Indian style all as specified.
M&L CPVC pipes SDR 11 Class 1 laid in trenches/ walls outer dia 20mm dia including all fittings
Taking down steel tubing / CPVC Tubing & connections 15mm bore and removing from the site.
Plain cement concrete (1:3:6) of type C-2 using 40mm graded stone aggregates as in foundations and mass concrete complete all as specified and directed.
S&F PVC (SWR) floor trap plain with grating including jointing with solvent cement 75mm.
M&L UPVC pipe (SWR) 75mm bore single socketed in any length with rubber ring joints fixed in walls.
S&F UPVC (SWR) bends 75mm bore any radius dismantling pieces or tapers.
S&F vitreous china wash down water closet (Pedestal pattern) (EWC) white including fixing complete with 'P' or 'S' trap complete all as specified and as directed.
S&F plastic water closset seat cover for EWC, black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device.
S&F Health faucet with tube with min length of tube 1 m and holder or chromium plated.
Angle stop cock of PTMT any colour high pressure screwed for CPVC pipe and fixed
Forming jambs etc to openings incl cuttings toothings and bondings into old work incl facing and pointing to match existing work complete.
M&L for preparation of new plastered surface and applying two coats of distempering of wall with oil emulsion distemper over a coat of primer.
S&F SS butt hinges medium weight cold rolled 100mm size
S&F aluminium anodised barrel tower bolts of extruded section 100mm long.
NOTE :- SIMILAR ITEMS OF ALL WORKS HAS BEEN CLUBBED)
K M SUBHANAIAH
Super Construction
star freeze service
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .