GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
REPAIR / MAINTENANCE TO DG SETS, AMF PANELS WITH CONNECTED WORKS AT AFS BELAGAVI UNDER GE (AF) SAMBRA
2025_MES_705068_1
GE(AF)/SAM/TOK-01 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
GE AF Sambra
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE AF Sambra
₹60,000
Yes
13 Jun 2025
23 Apr 2025
23 May 2025
23 Apr 2025
21 May 2025
9 May 2025
Amount
Disconnecting electric connection from alternator and fuel connection for repair and servicing including dismantling diesel filter, fuel filter, air filter, rubber coupling, fan belts, hose pipes all as required at site by opening nuts & bolts including repair to wiring of alternator and control panel if required, of DG set capacity 160KVA and replacement of old defective spare parts with new spare parts as mentioned here-in-after, including any type of machine work required at site/ workshop to complete the repair including complete servicing the engine all as required at site, re-assembling the spares in existing position complete and testing on completion all as specified and as directed by Engineer-in-Charge. Note: (a) New spare parts for engine shall be measured and paid seperately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and and plants required for dismantling engine will deemed to be included in quoted rates.
Supply only following new spare parts required for repair of DG Set capacity 160 KVA :-
Fuel Filter
Oil Filter
Air Filter
Fan belt
Hose pipe set
Ball bearning of alternator.
Slip rings assembly of alternator.
Disconnecting electric connection from alternator and fuel connection for repair and servicing including dismantling diesel filter, fuel filter, air filter, rubber coupling, fan belts, hose pipes all as required at site by opening nuts & bolts including repair to wiring of alternator and control panel if required, of DG set capacity 100 KVA to 125 KVA and replacement of old defective spare parts with new spare parts as mentioned here-in-after, including any type of machine work required at site/ workshop to complete the repair including complete servicing the engine all as required at site, re-assembling the spares in existing position complete and testing on completion all as specified and as directed by Engineer-in-Charge. Note: (a) New spare parts for engine will be measured and paid seperately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and and plants required for dismantling engine will deemed to be included in quoted rates.
Supply only following new spare parts required for repair of DG Set capacity 100 KVA to 125 KVA :-
Fuel Filter
Oil Filter
Air Filter
Fan belt
Hose pipe set
Ball bearning of alternator.
Slip rings assembly of alternator.
Disconnecting electric connection from alternator and fuel connection for repair and servicing including dismantling diesel filter, fuel filter, air filter, rubber coupling, fan belts, hose pipes all as required at site by opening nuts & bolts including repair to wiring of alternator and control panel if required, of DG set capacity 62.5 KVA to 82.5 KVA and replacement of old defective spare parts with new spare parts as mentioned here-in-after, including any type of machine work required at site/ workshop to complete the repair including complete servicing the engine all as required at site, re-assembling the spares in existing position complete and testing on completion all as specified and as directed by Engineer-in-Charge. Note: (a) New spare parts for engine shall be measured and paid seperately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and and plants required for dismantling engine will deemed to be included in quoted rates.
Supply only following new spare parts required for repair of DG Set capacity 62.5 KVA to 82.5 KVA :-
Fuel Filter
Oil Filter
Air Filter
Fan belt
Hose pipe set
Ball bearning of alternator.
Slip rings assembly of alternator.
Disconnecting electric connection from alternator and fuel connection for repair and servicing including dismantling diesel filter, fuel filter, air filter, rubber coupling, fan belts, hose pipes all as required at site by opening nuts & bolts including repair to wiring of alternator and control panel if required, of DG set capacity 30 KVA to 50 KVA and replacement of old defective spare parts with new spare parts as mentioned here-in-after, including any type of machine work required at site/ workshop to complete the repair including complete servicing the engine all as required at site, re-assembling the spares in existing position complete and testing on completion all as specified and as directed by Engineer-in-Charge. Note: (a) New spare parts for engine shall be measured and paid seperately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and and plants required for dismantling engine will deemed to be included in quoted rates.
Supply only following new spare parts required for repair of DG Set capacity 30 KVA to 50 KVA :-
Fuel Filter
Oil Filter
Air Filter
Fan belt
Hose pipe set
Ball bearning of alternator.
Disconnecting electric connection from alternator and fuel connection for repair and servicing including dismantling diesel filter, fuel filter, air filter, rubber coupling, fan belts, hose pipes all as required at site by opening nuts & bolts including repair to wiring of alternator and control panel if required, of DG set capacity 7.5 KVA to 15 KVA and replacement of old defective spare parts with new spare parts as mentioned here-in-after, including any type of machine work required at site/ workshop to complete the repair including complete servicing the engine all as required at site, re-assembling the spares in existing position complete and testing on completion all as specified and as directed by Engineer-in-Charge. Note: (a) New spare parts for engine will be measured and paid seperately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and and plants required for dismantling engine will deemed to be included in quoted rates.
Supply only following new spare parts required for repair of DG Set capacity 7.5 KVA to 15 KVA :-
Fuel Filter
Oil Filter
Air Filter
Fan belt
Hose pipe set
Ball bearning of alternator.
Supply and filling engine oil/lubricant, 20 W 40 grade, suitable for diesel engine of DG set of any capacity and any make, complete all as specified and as directed. Note:-The contractor must submit the digital records/photographs while operating this item
S&F Battery 105 AH with initial charging and connecting up including taking down unserviceable lead acid battery complete all as specified and directed.
S&F Battery 130 AH with initial charging and connecting up including taking down unserviceable lead acid battery complete all as specified and directed.
S&F battery charger SMPS based suitable for 6 Amps, 12 volts batteries including taking out unserviceable battery charger any type complete all as specified and directed.
S&F Voltage Monitoring Relay (VMR) suitable for 3 phase, 40 to 160 KVA DG Set to AMF Panel and including taking out old VMR relay any type complete all as specified and directed.
Servicing of self starter after taking down from DG Set capacity upto 75 KVA, transporting to workshop, opening and replacing the defective parts / copper wire winding, reassembling, installing on original position, testing for smooth functioning complete all as specified and directed.
Servicing of self starter after taking down from DG Set capacity upto 100 to 160 KVA, transporting to workshop, opening and replacing the defective parts / copper wire winding, reassembling, installing on original position, testing for smooth functioning all as specified and directed.
S&F in repairs Battery Lead of size 35 Sqmm copper single core flexible wire FR PVC insulated with thimble complete all as specified and directed.
Supply & filling Coolant additive in 10 Ltrs pack complete all as specified and directed. Note:-The contractor must submit the digital records/photographs while operating this item
S&F in repairss armed hose flexible suitable for 10 to 160 KVA all as specified & directed
S&F change over off load switch 4 pole 63 Amp with sheet metal enclosure including necessary modification to accommodate the change over switch including with taking out old change over switch complete all as specified and as directed..
S&F in repairs single phase preventer in panel to prevent single phasing complete all as spcified and directed.
S&F Power contactor 4 pole 7.5 to 40 KVA, Type MCX 12 suitable for DG Set AMF panel, including necessary connections with PVC insulated suitable size wire including removing the unserviceable contactor complete all as specified and directed.
S&F Power contactor 4 pole 50 to 62.5 KVA, Type MCX 22 suitable for DG Set AMF panel including necessary connections with PVC insulated suitable size wire including removing the unserviceable contactor comlete all as specified and directed.
S&F Power contactor 4 pole 75 to 160 KVA Type MCX 33 suitable for DG Set AMF panel, including necessary connections with PVC insulated suitable size wire including removing the unserviceable contactor complete all as specified and directed.
Supply and filling distilled water for top up levelling of batteries complete all as specified and directed.
S&F Door Hinges (Left handle) for DG set of any capacity suitable for existing door including with taking out old unserviceable hinges complete all as specified and directed.
All as per Srl item No. 123 above but Door Hinges (Right handle)
S&F relay cord 12 Volt suitable for 3 phase, 40 to 160 KVA DG Set to AMF Panel and including taking out old relay cord any type complete all as specified and directed.
S&F Push Switch for AMF Panel of DG set any capacity as per existing including taking out old unserviceable switches complete all as specified and directed.
All as per Srl item No. 33 above but 2 channel.
All as per Srl item No. 33 above but 3 channel.
All as per Srl item No. 33 above but 4 channel.
S&F LLOP (Low Lub Oil Pressure) for Panel of DG set any capacity including taking out old unserviceable switches complete all as specified and directed.
S&F glass channel relay 12 Volt for Panel of DG set any capacity as per existing switch including taking out old unserviceable glass relay complete all as specified and directed.
S&F CT Coil cap 75/5 Amp for Panel of DG set any capacity as per existing including taking out unserviceable any type of CT coil complete all as specified and directed.
S&F LVM (Line Voltage Monitor) for Panel of DG set any capacity as per existing including taking out old unserviceable LVM complete all as specified and directed.
Cleaning the Radiator of DG Set of capapcity upto 75 KVA, cleaning and removing all scale and dirt, etc, arresting of leakages/blockages if any, complete all as specified and directed.
Cleaning the Radiator of DG Set of capapcity upto 100 KVA to 160 KVA, cleaning and removing all scale and dirt, etc, arresting of leakages/blockages if any, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not le. than 1.5 m below normal ground level connected to Galvanized Strip 32x6mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 15 mm dia light grade pipe for protection of earth electrode 20 mm dia funnel for watering all as specified and directed and tested on completion.. (AMF Panel 05 Nos X 02 Each and LT Panel - 05 Nos x 02 Each)
Supply, fixing and commissioning of CPRI Approved AMF panel of IP 65 rating for existing DG set of Capacity 62.5 KVA made from CRCA sheet 3.15.mm thick Outdoor pedestal type supported on MS iron channel 75 x 40mm, totally enclosed with front and rear opening, hinged doors with projected a raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, stickering of switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 copper bus bars with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A Capacity complete and Powder coating, necessary internal electric connection as required and provision of the following: -
S&F in repairs enclosure of MCCB suitable size for mounting of MCBB 100-400 Amps, 4 pole complete all as specified and directed.
S&F in replacement MCCB 4 pole 400Amps 415 Volts, Adjustable type with breaking capacity 36 KA including connecting up with suitable aluminum cable lugs etc.complete all as specified and directed
S&F in replacement MCCB 4 pole, 250Amps 415 Volts, Adjustable type with breaking capacity 25 KA including connecting up with suitable alumnium cable lugs etc. complete all as specified and directed
S&F in replacement MCCB 4 pole, 200Amps 415 Volts, Adjustable type with breaking capacity 25 KA including connecting up with suitable alumnium cable lugs etc. complete all as specified and directed.
S&F in replacement MCCB 4 pole, 100 Amps 415 Volts, Adjustable type with breaking capacity 16 KA including connecting up with suitable alumnium cable lugs etc. complete all as specified and directed
S&F in replacement MCCB 4 pole, 63Amps 415 Volts, Adjustable type with breaking capacity 16 KA including connecting up with suitable alumnium cable lugs etc. complete all as specified and directed
Supply, laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core, 120 Sqmm including taking down of old unserviceable cable complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core, 50 Sqmm including taking down of old unserviceable cable complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core, 35 Sqmm including taking down of old unserviceable cable complete all as specified and as directed.
Supply laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core, 25 Sqmm including taking down of old unserviceable cable complete all as specified and as directed.
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in hard/dense soil complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soil complete all specified and as directed.
Removing excavated materials /soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all specified and as directed.
S&F in replacement Double wall corrugated HDPE Pipe IS-16205, outer dia 40 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
S&F in replacement Double wall corrugated HDPE Pipe IS-16205, outer dia 50 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
S&F in replacement Double wall corrugated HDPE Pipe IS-16205, outer dia 100 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
S&F in replacement galvanised iron pipes 40mm bore, light grade, with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors complete all as specified & directed
S&F in replacement galvanised iron pipes 50mm bore, light grade, with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors complete all as specified & directed
M&L for cutting the tar macadam road / hard standings for laying cable and excavating not exe. 60cm wide and not exc 75cm depth and getting out all as directed including filing back, consolidating etc complete and finishing it with 200mm thick PCC 1:4:8, type D-2 complete all as specified and directed
M&L for HT/LT Cable route indicator with a welded/riveted disc of 100mm dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x 4 mm thick dug in ground with in and incl PCC 1:3:6 type C1 using 20mm graded aggregate at approx distance 30 mtr including necessary earth work complete all as specified and directed
DHAIRYASIL RAMAKANT DESAI (BID ID -3296250)
M/s. VIJAY ELECTRICALS (BID ID -3302169)
R. P. Suppliers and Construction Co. (BID ID -3302215)
Kedar Electricals (BID ID -3301936)
metro electrical services (BID ID -3296883)
M/S Bhagyawanticonstruction (BID ID -3299642)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .