Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹22.8 L+₹11,594.78 (0.51%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹23.3 L+₹59,905.28 (2.64%)Rejected-AOC 20 JAIN BAZAR JAMMU 180003 J K | JAMMU | JAMMU | J K | 180003 | L3 | Rejected-AOC OK | |
| 4 | L4₹26.7 L+₹4.1 L (18.0%)Rejected-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC OK | |
| 5 | L5₹27.5 L+₹4.8 L (21.2%)Rejected-AOC 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L5 | Rejected-AOC OK |
Tender Value
₹29.7 L
EMD Value
₹59,500
Closing Date
9 Apr 2024, 6:00 pmClosed
GE (Army) Dhar Road
GE (Army) Dhar Road
REPAIR AND MAINT OF LT PANELS AND CERTAIN WORKS AT DHAR ROAD UNDER GE ARMY DHAR ROAD
2024_MES_645217_1
8069/NIT-66/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (Army) Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (Army) Dhar Road
₹59,500
Yes
20 Sept 2024
6 Mar 2024
11 Apr 2024
7 Mar 2024
9 Apr 2024
3 Apr 2024
Amount
Excavation in trenches in any type of soil n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of poles,cable laying etc, including forming bottom surface to required level and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in any type of soil including spreading, leveling,watering & well ramming in layers not .exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches and punning down complete all as specified and directed by Engineer-in-Charge.
Material and labour cover to underground cable with one layer of bricks using sub class 'B' bricks laid flat acorss the cable complete all as specified and directed by Engineer-in-Charge.
Supply, Laying only in trenches / fixing in wall or pole etc as in repair of XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of following sizes /cross sectional area complete all as specified and directed by Engr-in-charge.
185 Sq mm 3.5 Core
95 Sq mm 3.5 Core
16 Sq mm 2 Core
10 Sq mm 2 Core
25 Sq mm 3.5 Core
16 Sq mm 4 Core
Taking down old UNSV LT Panel any type and shape and supply , installation, testing and commissioning new LT Panel(CPRI Approved ) in replacement, double door,outdoor type, of size (0.75 M highx0.6M widex0.35M deep) , factory made out of CRCA MS sheet not less than 3.0 mm thick, front & back openable including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 40X40X5 mm welded with & including 4 Nos legs not less 900mm high MS angle of size 40X40X5 mm ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements comprising of the following complete all as specified and as directed by Engr-in-Charge. :- (a) Aluminium busbar duly encased in & including colour coded FRP Sleeves of size 40mmX10mm mounted on SMC/DMC red insulatorsinsulators (b) MCCB 250 amp 25 kA, 4 Pole with with adjustable thermal setting (c) Aluminium Earth bus bar of size 40mm X5 mm terminating outside from both sides of LT Panel
All as per item 7 Above but of comprising of the following :- (a) Aluminium busbar of size Aluminium busbar duly encased in & including colour coded FRP Sleeves of size 50mmX5mm mounted on SMC/DMC red insulatorsinsulators (b) MCCB 160 amp 25 kA, 4 Pole with with adjustable thermal setting (c) Aluminium Earth bus bar of size 50mm X5 mm terminating outside from both sides of LT Panel
All as per item 7 Above but comprising of the following :- (a) Aluminium busbar of size Aluminium busbar duly encased in & including colour coded FRP Sleeves of size 40mmX5mm mounted on SMC/DMC red insulatorsinsulators (b) MCCB 125 amp 25 kA, 4 Pole (c) Aluminium Earth bus bar of size 40mm X5 mm terminating outside from both sides of LT Panel
Supply & fixing voltmeter flush mounted (0-500V) in replacement of old UNSV voltmeter complete all as specified and directed by Engr-incharge
Supply & fixing Amp meter flush mounted (0-500A) in replacement of old UNSV ampmeter complete all as specified and directed by Engr-incharge
supply and fixing in replacement MCCB of following ratings complete all as specified and directed by Engr-incharge
MCCB 63 Amps 4 pole, 415 V , breaking capacity 16 KA
MCCB 100 Amps 4 pole, 415 V , breaking capacity 16 KA
MCCB 125 Amps, 4 pole,415 V , breaking capacity 16 KA
MCCB 160 Amps, 4 Pole,415 V, breaking capacity 25/36 KA, adjustable type
MCCB 200 Amps, 4 Pole,415 V, breaking capacity 25/36 KA, adjustable type
MCCB 250 Amps, 4 Pole, 415 V, breaking capacity 35/36 KA, adjustable type
MCCB 350/400 Amps, 4 Pole, 415 V, breaking capacity 35/36 KA, adjustable type
MCCB 630 Amps, 4 Pole, 415 V, breaking capacity 50 KA ,adjustable type
M&L For repairing, dismantling defective LT Panel /Bus Bar Chamber , indoor/ outdoor after opening of all incoming & outgoing cable connections,uprooting from foundation , cutting & setting aside burnt cable ends, Opening of loop by excavating around near LT panel & refixing at suitable place but height not less than 900 mm from ground level by fixing MS angle iron legs on bric work/ PCC 1:3:6,cleaning bus bars, inseting new cable lugs in cut ends of cables & connecting to bus bars/ MCCBs,cleaning of whole panel & welding at places/ welding new hinges not less than 150 mm long at three places in each door complete including painting with one coat of synthetic enamel paint from outside after preparation of old surfaces complete all as specified and as directed by Engr-in-Charge.
Taking down old UNSV Bus bar Chamber any type and shape and supply , installation, testing and commissioning in replacement busbar chamber made out of CRCA steel sheet Minimum of 3 mm thick , outdoor type, double door of size (0.6Mx0.60M x 0.35M) factory made, front & back openable,including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 35X35X5 mm welded with & including 4 Nos legs not less 900mm high MS angle of size 35X35X5 mm ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including 5 Nos Aluminium Bus Bar ( 3 for phases+ 1 for neutral + 1 for earth) duly encased in & including colour coded FRP Sleeves of size 50mmX5mm mounted on SMC/DMC red insulators Insulator (RYBN)complete all as specified and as directed by Engr-in-Charge.
All as per item No 14 above but bus bar chamber of size 0.6 MX 0.4 M X 0.25 M & with & including 5 Nos Aluminium Bus Bar ( 3 for phases+ 1 for neutral + 1 for earth) duly encased in & including colour coded FRP Sleeves of size 40mmX5mm
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board made out of CRCA MS sheet of size 0.90 M X 0.9 M X 0.40 M not less than 3.0 mm thick, front & back openable (CPRI approved) including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 50 mm X50 mm X 6 mm welded with & including 4 Nos MS angle legs of size50 mm X50 mm X 6 mm not less 900mm high ,grouted in PCC 1:3:6 type C-1 factory made out of ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including Aluminium Bus Bar duly encased in & including colour coded FRP Sleeves of size 40mmX10mm mounted on SMC/DMC red insulators Insulator (RYBN) complete all as specified and as directed by Engr-in-Charge comprising of the following accessories :- (a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-250A, with & including CTs 400/5 type-01 Set. (c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 250 Amp FP 25KA MCCB with adjustable thermal setting -1NO (e) MCCB 4 Pole 100 Amp - 02 Nos (f) MCB SPN 63 Amp - 02 Nos (g) Space for provision of 4 pole MCCB 63 Amps 16 KA- 01Nos
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board made out of CRCA MS sheet of size 0.90 M X 0.75 M X 0.40 M not less than 3.0 mm thick, front & back openable (CPRI approved) including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 50 mm X50 mm X 6 mm welded with & including 4 Nos MS angle legs of size50 mm X50 mm X 6 mm not less 900mm high ,grouted in PCC 1:3:6 type C-1 factory made out of ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including Aluminium Bus Bar duly encased in & including colour coded FRP Sleeves of size 40mmX10mm mounted on SMC/DMC red insulators Insulator (RYBN) complete all as specified and as directed by Engr-in-Charge comprising of the following accessories :- (a) Voltmeter flush mounted 0-500 V type -01 No. (b) Ammeter flush mounted 0-250A, with & including CTs 400/5 type-01 Set. (c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 250 Amp FP 25KA with adjustable thermal setting -1NO (e) MCCB 125 Amp FP 16 KA with adjustable thermal setting -1NO (f ) MCB SPN 63 Amp - 03 Nos (g) Space for provision of 4 pole MCCB 63 Amps 16 KA- 01Nos
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board made out of CRCA MS sheet of size 0.90 M X 0.75 M X 0.40 M not less than 3.0 mm thick, front & back openable (CPRI approved) including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 50 mm X50 mm X 6 mm welded with & including 4 Nos MS angle legs of size50 mm X50 mm X 6 mm not less 900mm high ,grouted in PCC 1:3:6 type C-1 factory made out of ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including Aluminium Bus Bar duly encased in & including colour coded FRP Sleeves of size 40mmX10mm mounted on SMC/DMC red insulators Insulator (RYBN) complete all as specified and as directed by Engr-in-Charge comprising of the following accessories :- (a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-250A,with & including CTs 500/5 type-01 Nos. (c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 125 Amp 4 pole 10KA with adjustable thermal setting -1NO (e) MCB SPN 63 Amp - 12 Nos (f) Space for provision of 3 Phase Electric Meter- 02 Nos (g) Space for provision of 4 pole MCCB 63 Amps 16 KA- 01Nos
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board made out of CRCA MS sheet of size 1.0 M X 0.9 M X 0.45 M not less than 3.0 mm thick, front & back openable (CPRI approved) including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 50 mm X50 mm X 6 mm welded with & including 4 Nos MS angle legs of size 50 mm X50 mm X 6 mm not less 900mm high ,grouted in PCC 1:3:6 type C-1 factory made out of ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including Aluminium Bus Bar duly encased in & including colour coded FRP Sleeves of size 40mmX10mm mounted on SMC/DMC red insulators Insulator (RYBN) complete all as specified and as directed by Engr-in-Charge comprising of the following accessories :- (a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-500A, with & including CTs 400/5 typetype-01 Set. (c) MCCB 200 Amp,4 Pole 25 KA , with adjustable thermal setting -1NO (d) MCCB 63 Amp FP 25 with adjustable thermal setting -3 Nos (e) MCB SPN 63 Amp - 12 Nos (f) Space for provision of 4 pole MCCB 63 Amps 16 KA- 01Nos
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board made out of CRCA MS sheet of ize 1.2 M X 1.1 M X 0.5 M not less than 3.0 mm thick, front & back openable (CPRI approved) including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 50 mm X50 mm X 6 mm welded with & including 4 Nos MS angle legs of size50 mm X50 mm X 6 mm not less 900mm high ,grouted in PCC 1:3:6 type C-1 factory made out of ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including Aluminium Bus Bar duly encased in & including colour coded FRP Sleeves of size 50mmX20mm mounted on SMC/DMC red insulators Insulator (RYBN) complete all as specified and as directed by Engr-in-Charge comprising of the following accessories :- (a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-1000A, with & including CTs 1000/5 type-01 Set. (c) MCCB 630Amp,4 Pole 50 KA , with adjustable thermal setting -1NO (d) MCCB 315 Amp 4 pole 25/36 KA with adjustable thermal setting -2Nos (e) MCCB 200 Amp 4 pole 25/36 KA with adjustable thermal setting -1Nos (f) MCB SPN 63 Amp - 3 Nos (g) Space for provision of 4 pole MCCB 200 Amps 16 KA- 01Nos
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board made out of CRCA MS sheet of size 1.1 M X 0.9 M X 0.45 M not less than 3.0 mm thick, front & back openable (CPRI approved) including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 50 mm X50 mm X 6 mm welded with & including 4 Nos MS angle legs of size50 mm X50 mm X 6 mm not less 900mm high ,grouted in PCC 1:3:6 type C-1 factory made out of ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including Aluminium Bus Bar duly encased in & including colour coded FRP Sleeves of size 50mmX20mm mounted on SMC/DMC red insulators Insulator (RYBN) complete all as specified and as directed by Engr-in-Charge comprising of the following accessories :- (a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-500A, with & including CTs 500/5 type-01 Nos. (c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 400 Amp FP 25/35 KA with adjustable thermal setting -1NO (e) MCCB 200 Amp FP 25/35 KA with adjustable thermal setting - 2 NOs. (f) MCCB 125 Amp FP 16 KA with adjustable thermal setting - 02 NOs (g) SPN 63 Amp - 03 NOs (h) Space for provision of 4 pole MCCB 100Amps 16 KA- 01Nos
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board made out of CRCA MS sheet of size 0.90 M X 0.75 M X 0.40 M not less than 3.0 mm thick, front & back openable (CPRI approved) including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 50 mm X50 mm X 6 mm welded with & including 4 Nos MS angle legs of size50 mm X50 mm X 6 mm not less 900mm high ,grouted in PCC 1:3:6 type C-1 factory made out of ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including Aluminium Bus Bar duly encased in & including colour coded FRP Sleeves of size 40mmX10mm mounted on SMC/DMC red insulators Insulator (RYBN) complete all as specified and as directed by Engr-in-Charge comprising of the following accessories :- (a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-250A, CTs operated, square digital type-01 Nos. (c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 160 Amp FP 25 KA with adjustable thermal setting -1NO (e) MCCB 100 Amp FP 16 KA with adjustable thermal setting - 01 NOs. (f) MCCB 63 Amp FP 10 KA with adjustable thermal setting - 02NOs (g) SPN 63 Amp - 02 NOs (h) Space for provision of 4 pole MCCB 100 Amps 25 KA- 01Nos
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth galvanised iron strip 32×6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion complete all as specified and as directed, including dimentaling of old UNSV earthing complete.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion complete all as specified and as directed, including dimentaling of old UNSV earthing complete.
Supply,fixing,cutting ,threading,shearing,shaping,bending,drilling Aluminium bus bar of requried sizes as requried to be fixed on transfomer LT bushings or panel or distribution board as requried at site
M & L for finding cable fault with electronic cable fault detector in HT/LT UG cable of any type any size, complete including earthwork all as directed by Engineer-in-charge.
S & F Cable jointing kit for 1100 V grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25/35/50/70 Sqmm 3.5 core.
S & F Cable jointing kit for 1100 V grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 95/120/150/185 Sqmm 3.5 Core.
Deduct Schedule of Credit of Rs. (-) 196540.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
ALLIED AGENCIES
A K JAIN AND SONS
K S BUILDERS
M/S M P Construction Co
R C TRADERS
M/S GURU DEV BUILDERS
DAVINDER SINGH
CITY TOP ELECTRICAL WORKS
M/SHansrajbuilder
LUXMI ELECTRONIC WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .