Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹47.9 L+₹8.1 L (20.3%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹49.7 L+₹9.9 L (24.8%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹49.8 L+₹10.0 L (25.1%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹54.7 L+₹14.9 L (37.3%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹47.6 L
EMD Value
₹96,000
Closing Date
16 Dec 2024, 6:00 pmClosed
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT
SPL REPAIR REPLACEMENT OF LT XLPE UG CABLES LT PANELS AND STREET LIGHTS AT OFFRS MN ACCN CASSEL ROAD T 01 TO T 10 AND P 11 TO P 33 AND POLO ROAD P 17 TO P 25 AND CONNECTED ALLIED WORKS AREA OF AGE SLDC UNDER GE U ES DELHI CANTT 10
2024_MES_685126_1
GE ELECT/D-74/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹96,000
Yes
12 Feb 2025
22 Nov 2024
19 Dec 2024
22 Nov 2024
16 Dec 2024
9 Dec 2024
Amount
M&L for excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil for laying / taking up / taking down of cables and getting out and levelling of bottom surface to required level complete all as specified and directed by Engineer- in- Charge.
M&L for returning filling in, Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
M&L for removing excavated material (i.e. soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer- in- Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. Note : Measurement shall be taken after punning down.
S&F of sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 complete all as specified and directed by Engineer- in- Charge.
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engineer- in- Charge. Cables of the following sizes:- Note Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately.
16 Sqmm 4 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
95 Sq mm 3.5 core.
120 Sq mm 3.5 core.
185 Sq mm 3.5 core.
S&F of Junction box thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65 (weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands (IP-65) and/or grommets (IP-55). Size of enclosure: (205x255 x112) mm With suitable connecters for 2Ph/1Ph loop in loop out and branch out vibration proof connections complete all as specified and directed by Engineer- in- Charge.
S&F of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS: 694 of size 2.5 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge.
S&F of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS: 694 of size 06 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge.
S&F of LED Flood lights 50 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge.
S&F of LED Flood lights 120 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge.
S&F of 90 Watt LED street light fittings made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge. Make : Crompton Greaves Model No. LFLN-120-CDL/60-M or equivalent in Havells / Bajaj / Philips as approved by GE.
M&L for GI Tubes of size 50 mm dia light grade, galvanised, with all fitting, laid in trenches for protection of cable in road /drain crossing complete all as specified and directed by Engineer- in- Charge.
Supply & installation of steel tubular swaged poles type 410 SP-31 (9 mtr long) of apprx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and as directed by Engineer-in-charge. NOTE :- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil, PCC foundation 1:4:8 type D-2, PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 m long for fixing of street light fitings. The steel pole shall be painted by bituminous paint total length inside and up to planting depth outside.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology including 150 mm dia HDPE pipe suitable for 0.6 mpa working pressure. Note :- The quoted rate shall deemed to be included of taking permission from concerned authority like Army Signal and other utility authority and any damage done during execution of work and the same will be repaired/replaced by the Contractor.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by Engineer- in- Charge and shown in electrical plate number 3 of MES SSR part-I (1991).
S&F of 10 W twister IP 65 Rated LED Bollard with robust design and efficient light distribution (garden lights) and pole base cover aestetocally designed decorative pole base cover, enhancing the appearance of the pole complete all as specified and directed by Engineer- in- Charge. Note :- The cost of excavation and PCC 1:3:6, type C-1 for foundation of size (20x20x20cm) required for post top light pole is deemed to be included in the quoted rate.
S&F of 40 W led post top crown HLYT-08 IP 65 LED post top die cast aluminium with stainless steelpins and toggle. reflector high quality anodized aluminium diffuser cover & power led (garden lights) Make HI-LITE and pole base cover aestetocally designed decorative pole base cover, enhancing the apearance of the pole complete all as specified and directed by Engineer- in- Charge. Note :- The cost of excavation and PCC 1:3:6, type C-1 for foundation of size (20 x 20 x 20cm) required for post top light pole is deemed to be included in the quoted rate.
Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 200A, factory made, CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4, type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) MCCB 125 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (c) spreader Link- 01 set( 06 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating
UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent. 3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. 4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. 5.The quoted rate includes the excavation, earth work and required base for fixing the complete panel.
Supplying, fabrication, installation, testing and commissioning in replacement of Bus bar panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 200A, factory made, CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel and comprising the followings. Incoming :- (a) MCCB 160 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (C) spreader Link- 01 set (08 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating
Taking out old rusted unserviceable LT panel and Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley. Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) and comprising the followings. Incoming:- (a) Change over 400 Amps 4 Pole - 01 No (b) Rotary handle- 01 No (c) spreader Link- 01 set( 08 Pcs)
(d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) Set of CT of ratio - 400/05 Amps (g) Aluminium bus bar of rating 400 Amps, 4 pole, mounted on SMC insulator - set of four Outgoing :- (a) 400A FP 36 KA MCCB - 01 No (b) 250A FP 36 KA MCCB - 01 No (c)125A FP 36 KA MCCB - 01 No (d) Rotary handle - 03 Nos Platform for Panel :- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer.
All as per Item No 22 here-in-before but comprising of the followings :- Incoming:- (a) MCCB 400 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (c) spreader Link- 01 set( 08 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) Set of CT of ratio - 400/05 Amps (g) Aluminium bus bar of rating 630 Amps, 4 pole, mounted on SMC insulator - set of four Outgoing. (a) 100A FP 25 KA MCCB -2 No (b) 160A FP 36 KA MCCB -3 No (c)200A FP 36 KA MCCB -3 No (d) Rotary handle- 08 No
All as per Item No 22 here-in-before but comprising of the followings :- Incoming:- (a) MCCB 250 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (c) spreader Link- 01 set( 08 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) set of CT of ratio - 250/05 Amps (g) Aluminium bus bar of rating 400 Amps, 4 pole, mounted on SMC insulator - set of four Outgoing :- (a) 200A FP 36 KA MCCB -1 No (b) 160A FP 36 KA MCCB -2 No (c) Rotary handle- 03 No
All as per Item No 22 here-in-before but comprising of the followings :- Incoming:- (a) MCCB 250 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (C) spreader Link- 01 set( 08 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) set of CT of ratio - 250/05 Amps (g) Aluminium bus bar of rating 400 Amps, 4 pole, mounted on SMC insulator - set of four Outgoing. (a) 160A FP 36 KA MCCB -2 No (b) 100A FP 36 KA MCCB -2 No (c) Rotary handle- 04 No
(vi) Aluminium bus bar of rating 1600 Amp- set of four (b) Outgoing (i) MCCB 4 pole, 315 Amps, 50 Hz, 415 Volts, 36 KA with microprocessor release - 02 Nos (ii) MCCB 4 pole, 200 Amps, 50 Hz, 415 Volts, 36 KA with microprocessor release - 03 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer.
M&L for Standard cable route indicator 10 cm dia, CI plate 6 mm thick embossed with raised lettering LT cable 1100 volts painted with luminous paint and mounted on angle iron 25x25x3mm and 0.6 mtr long embedded in PCC block 1:2:4 (size 30 cm x 15 cm x 15 cm) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer- in- Charge.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge.
SHREE BALAJEE ENTERPRISES (BID ID -3190736)
M/s JAIMAA ASSOCIATES (BID ID -3190581)
Vijay Electricals (BID ID -3185679)
MV Engineers And Contractors (BID ID -3186480)
mayur enterprises (BID ID -3190197)
Rajindera Enterprises (BID ID -3189676)
Ridhi engineers and builders (BID ID -3190609)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .