| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.0 L+₹17,250 (0.67%)Rejected-AOC NEW DUDHNOI GOALPARA | BARPETA | ASSAM | 783101 | L2 | Rejected-AOC L2 | |
| 3 | L3₹29.3 L+₹3.5 L (13.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹29.3 L+₹3.5 L (13.6%)Rejected-AOC NEW DUDHNOI GOALPARA | BARPETA | ASSAM | 783101 | L4 | Rejected-AOC L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Technically disqualified. Refer to technical minutes |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
23 May 2023, 2:00 pmClosed
Director, AHVD
OFFICE OF THE DIRECTOR, ANIMAL HUSBANDRY and VETERINARY DEPARTMENT, ASSAM CHENIKUTHI, GUWAHATI -3
CONSTRUCTION OF BUFFALO DEMO UNIT WITH APPROACH ROAD and DRAINAGE SYSTEM AT KHANAPARA FARM CAMPUS IN KAMRUP DISTRICT
2023_AHVD_30646_1
RIDF-XXVII (S/)/Kamrup/22-23/38
Open Tender
Civil Works
Item Rate
180 days
KHANAPARA
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,200
₹69,000
Yes
O/o The Director, AHVD, Chenikuthi
23 Nov 2023
29 Apr 2023
24 May 2023
29 Apr 2023
23 May 2023
12 May 2023
8 May 2023
Amount
2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / B24m+A1anual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
11.1 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:6 (1cement : 6 coarse
4.1 Providing and laying in position cement concrete of specified grade A9excluding the cost of centering and shuttering - All work up to plinth level : 4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
5.9 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
5.9 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
13.10 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.
11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m²
12.4 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m²
11.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
6.3 Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : 6.3.1 With F.P.S.(non modular) bricks
9.49 Providing and fixing expanded metal 20x60 mm strands 3.25 mm wide and 1.6mm thick for windows etc. including 62 x19 mm beading of II nd class teak wood and priming coat with approved steel primer all complete.
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at .......... diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding
Providing and laying interlocking concrete block pavement (M40) having thickness 80 mm as per technical specification
1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. . Group B
1.14.1 Wiring for circuit / sub-main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
1.14.2 Wiring for circuit / sub-main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
1.24.1 Supplying and fixing following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 5 /6 Amp. Switch
1.24.3 Supplying and fixing following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.15 / 16 Amp. Socket outlet
1.24.4 Supplying and fixing following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 3-pin 5 /6 Amp. Socket outlet
1.24.5 Supplying and fixing following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 6 pin 15 / 16 A socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
1.26 Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required.
1.27.1 Supplying and fixing following size modules, G.I. box, along with modular base and cover plate for modular switches in recess etc. as required 1 or 2 module (75mm x 75 mm)
1.27.2 Supplying and fixing following size modules, G.I. box, along with modular base and cover plate for modular switches in recess etc. as required 3 module (100 mm x 75mm )
1.27.4 Supplying and fixing following size modules, G.I. box, along with modular base and cover plate for modular switches in recess etc. as required 6 module (200 mm x 75mm )
1.33 Supplying and fixing 3pin, 5 A ceiling rose on the existing junction box / wooden block including connections etc. as required.
1.38 Supplying and fixing call bel / buzzer suitable for single phase, 230 V complete as required.
1.39 Providing and fixing plain 16 / 0.20 mm (0.50 sq.mm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor / wall or side of the table / door etc. as required.
1.41 Installation, testing and commissioning of pre-wired fluorescent fitting / compact fluorescent fitting of all types complete with all accessories and tube lamp etc. directly on ceiling / wall including connections with 1.5sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required.
1.44 Installation, testing and commissioning of ceiling Fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor single core cable etc. as required.
1.58 Supplying and fixing PVC batten / angle holder including connections etc. as required.
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution Board, 240 v on surface / recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB / RCCB / Isolator)
2.10.1 Supplying and fixing 5 A to 32 A rating 240 / 415 V, 10KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.3 Supplying and fixing 5 A to 32 A rating 240 / 415 V, 10KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1 Supplying and fixing following rating, double pole, 240V Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
5.2 Earthing with G.I. earth pipe 4.50 m long, 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
5.19 Providing and fixing 4.00 mm dia copper wire on surface or recess for loop earthing along with existing surface / recessed conduit / sub-main wiring cable as required.
7.1.1 Laying of one No PVC insulated and PVC sheathed / XLPE power cable of 1.1 KW grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
A.N Supply of LED buld 12 watt of Crompton Greaves make as specified and directed by the Department.
A.N Supplying of LED batten 20 watt Trim line Crompton / Havells / Bajaj / Philips make as specified and directed by the Department.
A.N Supplying of A.C. ceiling FAN with complete accessories like down rod, canopy etc. of following sweep as specified and directed by the Department (With out regulator)
A.N Load Security for 3-phase sevice connection (As per APDCL Rate)
A.N Add for energy Meter single phase and estimate cost to be paid to APDCL (As per APDCL Rate)
Rajib Mohan Das
MONSOON ENTERPRISE
DIGANTA BORAH
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .