Executive Engineer ED JPDCL Reasi
Hall no 301, block II, DC office complex, Reasi
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 25KVA sub station along with HT Tapline and LT line at Bakkal Railway Station, KRCL on turnkey basis in jurisdiction of Electric Div JPDCL Reasi
2023_PDD_214440_1
eNIT 10 of 2023-24 DT 31.05.2023
Open Tender
Electrical Works
Turn-key
120 days
at bakaal in jurisdiction of Electric div Reasi
As per tender documents
2 documents required · 2 mandatory
₹1,000
Office of Executive Engineer ED JPDCL Reasi
₹18,000
Office of Executive Engineer ED JPDCL Reasi
4 Jul 2023
1 Jun 2023
22 Jun 2023
1 Jun 2023
21 Jun 2023
1 Jun 2023
1 Jun 2023 - 16 Jun 2023
16 Jun 2023
Laying of 11KV HT Line
ST Pole 9 mtr ST 410 SP33
GI V cross-arm with top Bracket including clamp and GI Channel X-arm including clamps and braces
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type
ACSR Weasel Conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip (25x3)mm.
Aluminium Paint of reputed make
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete.
Laying of LT Line
8 Mtr. Long Pole( ST-410 SP15)
ACSR Weasel conductor
GI M Clamp for shackle Insulator
16 KN Polymer Shackle Insulators
Galvanized Nuts and Bolts.
Danger Plates
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip (25x3)mm.
Aluminium Paint of reputed make
Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
LT Line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply, Fabrication,Erection, Testing and commissioning of 25KVA Distribution substation
11/0.433KV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors fully Efficient Energy Level-2 (i.e actual Efficient energy level 3 redesignated as Efficient Energy Level 2 as per amendment no.4 of relevant IS ) , (Aluminium wound) and with LV cable box having detachable Aluminium Gland plate
9 mtr long Pole ST-410, SP33
Gapless Surge Arrestor, 9kV, 10kA, LA with polymer housing, Station type
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type
11kV Horn Gap Fuse set 3-phase, 200 Amp
50sqmm cable 1.1kv grade, PVC insulated stranded conductor FRLS type
11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of different sizes including clamps
Galvanised Nuts & Bolts
Earthing of substation - Excavation of earthing pit of dia 650mm & depth 3000mm, installation ofEarthing pipe of 40mm nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm x 3mm for connection of transformer body, GO set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
LT distribution box for 25KVA DTR with MCCB for incomer & SFU's for outgoing circuits
Danger Plates with clamps
G.I Barbed Wire for anti climbing
3-Phase, 4 Wire Trivector Meter with CT (Prodigy Meter)
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/Pole
Painting of Poles Aluminium Paint of reputed make
U3 ENTERPRISES
VEENA CONSTRUCTION CO.
RAVINDER SINGH
udhay partap singh
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .